Talada Appala Naidu
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Talada Appala Naidu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Sabha Raj Arya
Department of Electrical Engineering, Sardar Vallabhbhai National Institute of Technology, Surat, India
8 shared publications - Rakesh Maurya
Department of Electrical Engineering, Sardar Vallabhbhai National Institute of Technology, Surat, India
4 shared publications Rakesh Maurya
Department of Electrical Engineering Sardar Vallabhbhai National Institute of Technology Surat 395007 India
3 shared publications- Sajan K. Sadanandan
R&D Center - Smart Grid Integration, Dubai Electricity and Water Authority (DEWA), Dubai, UAE
2 shared publications - Sanjeevikumar Padmanaban
Department of Electrical Engineering, IT and Cybernetics, University of South-Eastern Norway, Porsgrunn, Norway
2 shared publications - Tareg Ghaoud
R&D Center - Smart Grid Integration, Dubai Electricity and Water Authority (DEWA), Dubai, UAE
2 shared publications
Latest Publications
- 24 November 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (1) , 25
Assessment of capacitor banks and active harmonic filter on power quality improvement for commercial applications
- 24 November 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (1) , 25
Assessment of capacitor banks and active harmonic filter on power quality improvement for commercial applications
- Open Access
A Study on Various Conditions Impacting the Harmonics at Point of Common Coupling in On-Grid Solar Photovoltaic Systems
Renewable penetration, particularly the increasing deployment of PV by residential customers, organizations, and utilities, is leading to the rapid evolution of the power grid. However, the power system’s architectural changes affect the quality of supply and give rise to power quality issues such as harmonics, fluctuations, disturbances, etc., at the point of common coupling (PCC). Therefore, in this work, a power network was modeled to study the impact of PV systems on PCC. At first, a detailed review is presented for on-grid PV systems with different inverter topologies, control techniques, sources of harmonic generation, and their mitigation strategies. After that, several use cases considering various sources of harmonics in a network with on-grid PV are modeled and simulated using MATLAB/Simulink. In-depth research was performed in this work to examine the many variables that affect harmonics, such as solar radiation levels, controller tuning, and load changes. Results with a real-time simulation platform (OPAL-RT) are presented in this paper for several use cases. Lastly, comprehensive discussions are presented from the acquired offline and real-time simulation results.
Open AccessA Study on Various Conditions Impacting the Harmonics at Point of Common Coupling in On-Grid Solar Photovoltaic Systems
Renewable penetration, particularly the increasing deployment of PV by residential customers, organizations, and utilities, is leading to the rapid evolution of the power grid. However, the power system’s architectural changes affect the quality of supply and give rise to power quality issues such as harmonics, fluctuations, disturbances, etc., at the point of common coupling (PCC). Therefore, in this work, a power network was modeled to study the impact of PV systems on PCC. At first, a detailed review is presented for on-grid PV systems with different inverter topologies, control techniques, sources of harmonic generation, and their mitigation strategies. After that, several use cases considering various sources of harmonics in a network with on-grid PV are modeled and simulated using MATLAB/Simulink. In-depth research was performed in this work to examine the many variables that affect harmonics, such as solar radiation levels, controller tuning, and load changes. Results with a real-time simulation platform (OPAL-RT) are presented in this paper for several use cases. Lastly, comprehensive discussions are presented from the acquired offline and real-time simulation results.
- 9 February 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (4) , 2637-2652
Optimized PI gains for dynamic voltage restorer control using admittance estimation strategy
- 9 February 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (4) , 2637-2652
Optimized PI gains for dynamic voltage restorer control using admittance estimation strategy
- 22 July 2021
- Published by Walter de Gruyter GmbH in International Journal of Emerging Electric Power Systems
- Vol. 23 (3) , 359-379
Coordinated control and parameters optimization for PSS, POD and SVC to enhance the transient stability with the integration of DFIG based wind power systems
This paper presents stability enhancement of a test system that is connected with a Wind Farm (WF) by using Power System Stabilizer (PSS) for Synchronous Generator (SG) and Power Oscillation Damper (POD) for Static Var Compensator (SVC). This paper also proposes a coordination mechanism for the controller to effectively damp out the oscillations and make the power system more stable by considering the uncertainties. The uncertainty is considered as wind speed variation and wind power penetration and different locations. The Particle Swarm Optimization (PSO) is used to overcome the controller parameter tuning drawbacks and controller coordination. The SG rotor speed deviation is selected as an objective function with various constraints for PSO. The transient stability analysis is carried out by considering large disturbance that is a three-phase fault. The nonlinear dynamic simulation results are obtained by integrating WF and SG replacement with the same rating WF. Evaluation and analysis are performed for various cases and different combination of without and with controllers. From the simulation results, it is noticed that oscillations in the system are minimized, and stability is enhanced at the maximum level. It also observed that the capability of SG and DFIG under three-phase fault is intensified by using PSO for optimized coordinated controller parameters. The robustness and effectiveness of the proposed approaches are evaluated on the IEEE-11 bus test system.
- 22 July 2021
- Published by Walter de Gruyter GmbH in International Journal of Emerging Electric Power Systems
- Vol. 23 (3) , 359-379
Coordinated control and parameters optimization for PSS, POD and SVC to enhance the transient stability with the integration of DFIG based wind power systems
This paper presents stability enhancement of a test system that is connected with a Wind Farm (WF) by using Power System Stabilizer (PSS) for Synchronous Generator (SG) and Power Oscillation Damper (POD) for Static Var Compensator (SVC). This paper also proposes a coordination mechanism for the controller to effectively damp out the oscillations and make the power system more stable by considering the uncertainties. The uncertainty is considered as wind speed variation and wind power penetration and different locations. The Particle Swarm Optimization (PSO) is used to overcome the controller parameter tuning drawbacks and controller coordination. The SG rotor speed deviation is selected as an objective function with various constraints for PSO. The transient stability analysis is carried out by considering large disturbance that is a three-phase fault. The nonlinear dynamic simulation results are obtained by integrating WF and SG replacement with the same rating WF. Evaluation and analysis are performed for various cases and different combination of without and with controllers. From the simulation results, it is noticed that oscillations in the system are minimized, and stability is enhanced at the maximum level. It also observed that the capability of SG and DFIG under three-phase fault is intensified by using PSO for optimized coordinated controller parameters. The robustness and effectiveness of the proposed approaches are evaluated on the IEEE-11 bus test system.
- 14 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 2 (2) , 155-163
Performance of DVR Using Optimized PI Controller Based Gradient Adaptive Variable Step LMS Control Algorithm
A custom power device known as dynamic voltage restorer (DVR) has been investigated to operate a distribution system at its desired performance. The distribution system with voltage-related power quality issues in the supply side has been addressed through this article using DVR. Four different grid disturbances, such as voltage sag, swell, unbalances, and distortions, have been taken into account while testing the DVR capability. DVR has been controlled using optimized proportional and integral (PI) gains integrated with gradient adaptive variable learning rate least mean square control algorithm. Adaptiveness of variable step-size in LMS makes the control robust in case of dynamics in the system, which assures better performance. Also, the other major contribution of this article is the implementation of optimization-based self-tuning PI gains in the proposed control. The evaluation of optimizer in estimating the PI gains is presented in terms of the response of dc-link voltage DVR. The simulation work of proposed control algorithms on DVR has been done and satisfactory results are found. For the experimental validation, d-SPACE made Micro Lab Box is used as control processor, and both dynamic and steady-state results are discussed for its effectiveness.
- 14 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 2 (2) , 155-163
Performance of DVR Using Optimized PI Controller Based Gradient Adaptive Variable Step LMS Control Algorithm
A custom power device known as dynamic voltage restorer (DVR) has been investigated to operate a distribution system at its desired performance. The distribution system with voltage-related power quality issues in the supply side has been addressed through this article using DVR. Four different grid disturbances, such as voltage sag, swell, unbalances, and distortions, have been taken into account while testing the DVR capability. DVR has been controlled using optimized proportional and integral (PI) gains integrated with gradient adaptive variable learning rate least mean square control algorithm. Adaptiveness of variable step-size in LMS makes the control robust in case of dynamics in the system, which assures better performance. Also, the other major contribution of this article is the implementation of optimization-based self-tuning PI gains in the proposed control. The evaluation of optimizer in estimating the PI gains is presented in terms of the response of dc-link voltage DVR. The simulation work of proposed control algorithms on DVR has been done and satisfactory results are found. For the experimental validation, d-SPACE made Micro Lab Box is used as control processor, and both dynamic and steady-state results are discussed for its effectiveness.
- Open Access
- 30 December 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 14 (4) , 821-833
Variable fractional power‐least mean square based control algorithm with optimized PI gains for the operation of dynamic voltage restorer
The operation of Dynamic Voltage Restorer has been studied for the mitigation of supply voltage disturbances like sag, swell, distortions, and unbalances. A Dynamic Voltage Restorer with three single‐phase Voltage Source Converters has been implemented for this purpose. Dynamic Voltage Restorer's compensation capability has been evaluated while introducing the above‐said voltage related disturbances in the supply by different means. A control algorithm named Variable Fractional Power‐Least Mean Square has been proposed for generating the load reference voltage for Dynamic Voltage Restorer. Variable Fractional Power‐Least Mean Square extracts the fundamental active and reactive component out of non‐ideal supply voltage and is thus, used in generating reference load voltage. This algorithm is more robust with respect to disturbance due to variable step size and is computationally less expensive. In addition, an optimization‐based approach has been proposed to estimate the approximate values of PI control gains. For this reason, a population‐based optimization method known as Sine Cosine Optimization has been used. The added feature of the optimization method is the reduction of computational time as compared to conventional PI controller tuning. A model of Dynamic Voltage Restorer using Variable Fractional Power‐Least Mean Square control algorithm with Sine Cosine Optimization tuned PI gains has been built in MATLAB Simulink as well as a reduced scale experimental prototype and their results have been presented with discussion.
- 30 December 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 14 (4) , 821-833
Open AccessVariable fractional power‐least mean square based control algorithm with optimized PI gains for the operation of dynamic voltage restorer
The operation of Dynamic Voltage Restorer has been studied for the mitigation of supply voltage disturbances like sag, swell, distortions, and unbalances. A Dynamic Voltage Restorer with three single‐phase Voltage Source Converters has been implemented for this purpose. Dynamic Voltage Restorer's compensation capability has been evaluated while introducing the above‐said voltage related disturbances in the supply by different means. A control algorithm named Variable Fractional Power‐Least Mean Square has been proposed for generating the load reference voltage for Dynamic Voltage Restorer. Variable Fractional Power‐Least Mean Square extracts the fundamental active and reactive component out of non‐ideal supply voltage and is thus, used in generating reference load voltage. This algorithm is more robust with respect to disturbance due to variable step size and is computationally less expensive. In addition, an optimization‐based approach has been proposed to estimate the approximate values of PI control gains. For this reason, a population‐based optimization method known as Sine Cosine Optimization has been used. The added feature of the optimization method is the reduction of computational time as compared to conventional PI controller tuning. A model of Dynamic Voltage Restorer using Variable Fractional Power‐Least Mean Square control algorithm with Sine Cosine Optimization tuned PI gains has been built in MATLAB Simulink as well as a reduced scale experimental prototype and their results have been presented with discussion.
- 12 November 2020
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 31 (10)
Comparative performance of dynamic voltage restorer using adaptive control algorithms with optimized error regulator gains
- 12 November 2020
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 31 (10)
Comparative performance of dynamic voltage restorer using adaptive control algorithms with optimized error regulator gains
- Open Access
- 20 May 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (14) , 2656-2665
Compensation of voltage‐based power quality problems using sliding mode observer with optimised PI controller gains
This study discusses a control algorithm for dynamic voltage restorer (DVR) based on sliding mode observer (SMO) with an optimisation‐based proportional integrator (PI) tuning to compensate the voltage related power quality problems. In this work, a three‐phase VSC‐based topology of DVR is selected with a self‐supported capacitor. This DVR configuration using the proposed control algorithm has been used for mitigation of unbalance, sag, and swells in the supply voltage. The estimation of grid parameters in undesirable situations based on the exosystemic model are the advantages proposed control. New nature‐inspired optimisation algorithm named as Harris hawks optimiser (HHO) has been applied to obtain the PI gains in the control algorithm to eliminate the time required for the tuning process. The main advantage of HHO is the avoidance of local minima and exploration and exploitation features of the algorithm. DVR system with a combination of SMO‐based control algorithm along with HHO optimised PI controllers have been developed in MATLAB/Simulink and tested for above said voltage‐based disturbances mitigation in the supply voltage.
- 20 May 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (14) , 2656-2665
Open AccessCompensation of voltage‐based power quality problems using sliding mode observer with optimised PI controller gains
This study discusses a control algorithm for dynamic voltage restorer (DVR) based on sliding mode observer (SMO) with an optimisation‐based proportional integrator (PI) tuning to compensate the voltage related power quality problems. In this work, a three‐phase VSC‐based topology of DVR is selected with a self‐supported capacitor. This DVR configuration using the proposed control algorithm has been used for mitigation of unbalance, sag, and swells in the supply voltage. The estimation of grid parameters in undesirable situations based on the exosystemic model are the advantages proposed control. New nature‐inspired optimisation algorithm named as Harris hawks optimiser (HHO) has been applied to obtain the PI gains in the control algorithm to eliminate the time required for the tuning process. The main advantage of HHO is the avoidance of local minima and exploration and exploitation features of the algorithm. DVR system with a combination of SMO‐based control algorithm along with HHO optimised PI controllers have been developed in MATLAB/Simulink and tested for above said voltage‐based disturbances mitigation in the supply voltage.
- 16 March 2019
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 47 (4-5) , 329-344
Phase Locked Loop Based on Third Order SSI for Compensation of Voltage-Related Power Quality Issues Using DVR
Application of dynamic voltage restorer (DVR) is extended to the compensation of distortions and imbalances in the grid voltage by applying phase locked loop based on the sinusoidal signal integrator of third order. For dealing the distortions and imbalances in voltage, a fundamental positive sequence component is required. The conventional PLLs fail to track grid voltage in case of distortions and imbalances in supply system. Under distorted or unbalanced grid voltage condition, the fundamental positive sequence components are to be extracted from third order sinusoidal signal integrator phase locked loop (TOSSI-PLL). This kind of extraction of grid angle from the distorted/unbalanced grid helps to improve the dynamic performance. The performance of DVR with TOSSI-based PLL under sag, swell, distortions and an imbalance has been demonstrated using MATLAB/Simulink and validated in real time through OP-5142 using FPGA-based XC3S5000 series processor.
- 16 March 2019
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 47 (4-5) , 329-344
Phase Locked Loop Based on Third Order SSI for Compensation of Voltage-Related Power Quality Issues Using DVR
Application of dynamic voltage restorer (DVR) is extended to the compensation of distortions and imbalances in the grid voltage by applying phase locked loop based on the sinusoidal signal integrator of third order. For dealing the distortions and imbalances in voltage, a fundamental positive sequence component is required. The conventional PLLs fail to track grid voltage in case of distortions and imbalances in supply system. Under distorted or unbalanced grid voltage condition, the fundamental positive sequence components are to be extracted from third order sinusoidal signal integrator phase locked loop (TOSSI-PLL). This kind of extraction of grid angle from the distorted/unbalanced grid helps to improve the dynamic performance. The performance of DVR with TOSSI-based PLL under sag, swell, distortions and an imbalance has been demonstrated using MATLAB/Simulink and validated in real time through OP-5142 using FPGA-based XC3S5000 series processor.