WZWenxue Zhang

Wenxue Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wenxue Zhang has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental Study on Seismic Performance of Earthquake-Damaged RC Frames Strengthened by Steel Jacketing

    by Xinyu Feng, Ying Chen, Wenxue Zhang, Susu Yang

    This study investigates the performance of steel jacketing for strengthening earthquake-damaged reinforced concrete (RC) frames. A five-story single-bay earthquake-damaged RC frame specimen was strengthened with steel jacketing, and shaking table tests and ANSYS finite element simulations were conducted to systematically analyze the dynamic characteristics, acceleration responses, and displacement responses of the structure. Strengthened and unstrengthened damaged-frame models were established to comparatively evaluate the strengthening effectiveness, and the influence of steel angle thickness on the strengthening performance was further discussed. The results indicate that damage in the strengthened structure was mainly concentrated in the lower stories. Although the vibration response increased markedly with increasing earthquake intensity, the frame maintained satisfactory overall integrity without collapse. Steel jacketing significantly enhances the lateral stiffness and natural frequencies of the damaged RC frame, delays stiffness degradation, and reduces peak floor accelerations and floor displacements. Moreover, the strengthening effect becomes more pronounced with increasing earthquake intensity. In addition, increasing the thickness of the steel angles appropriately can further improve the seismic performance and structural safety of the damaged RC frames.

  • Experimental study on axial compression performance of mortise-and-tenon precast concrete beam–column joints

    by Cheng Zhang, Wenxue Zhang, Junwei Wang, Lijun Su

    Mortise-and-tenon precast concrete (MTPC) beam–column joints utilize a mortise–tenon structure with longitudinal prestressing to secure their connections. This approach offers advantages such as dry construction, easy assembly, a short construction period, and the possibility of disassembly. To meet the “strong joint” requirement, this study enhances the core areas of the joints through ultra-high–performance concrete (UHPC) reinforcement and rebar enhancement. First, the structure and assembly method for MTPC joints are introduced. Subsequently, five distinct specimens are fabricated for testing: two UHPC-reinforced models, one rebar-enhanced model, one standard MTPC joint model, and one cast-in-place joint model. All specimens are then subjected to monotonic axial compression tests. The results show that the optimized MTPC joints exhibit significantly improved axial compressive strength, reaching 90% to 100% of the capacity of the cast-in-place joint. With regard to the optimization methods, whereas increasing rebar ratios enhances axial strength, it does not fully achieve the “strong joint” criterion. By contrast, UHPC reinforcement significantly boosts axial compressive capacity, achieving the desired “strong joint” standard. After axial load is used to compact the assembly gaps in MTPC joints, the overall integrity is made strong, axial stiffness remains stable, and the load transfer path becomes clear. With UHPC reinforcement, force transmission through the MTPC joint components becomes more reliable, with the tenon bearing more axial load; however, the tenon should not be used as the main vertical force transmission section. Finally, it is found that the axial compressive load capacity calculation method recommended by the Chinese code can accurately and safely predict the axial compressive load capacities of MTPC joints.

  • Experimental Investigation and Calculation Method on Axial Compression Properties of Unbonded Prestressed Mortise–Tenon Precast Concrete Mid Joint

    by Cheng Zhang, Wenxue Zhang, Junwei Wang, Xiuli Du, Lijun Su

    This study examines the axial compression performance of unbonded prestressed mortise–tenon beam–column joints (MTPC). The MTPC joint employs a mortise–tenon configuration, achieving tight compression through unbonded prestressed steel strands at the column's center, enhancing prefabrication efficiency. Three axial compression test models were fabricated and subjected to axial monotonic loading, with experimental phenomena and results analyzed. The results show the optimized MTPC joint achieves approximately 90% of the column‐end axial capacity, while MTPC joints reinforced with ultra‐high‐performance concrete (UHPC) surpass the column‐end capacity, fulfilling the “strong joints, weak components” design principle. Minor gaps during assembly require axial pressure for tight component contact, but the assembled joint demonstrates excellent integrity, stable axial stiffness, and effective load transfer. A calculation method for the axial load‐bearing capacity of MTPC joints is proposed, along with a finite element model. Comparison with experimental results validates the model's accuracy. Theoretical calculations, experimental data, and finite element analysis collectively confirm the proposed method effectively predicts the axial compression capacity and mechanical behavior of MTPC joints under axial loading. This research highlights the MTPC joint's potential for enhancing construction efficiency and structural performance in prefabricated systems.

  • Experimental and theoretical studies on the mechanical performances of a novel self-centering friction damper

    by Yongrui Zheng, Wenxue Zhang, Yuguang Fu, Cheng Zhang, Miren Rong, Jizhe Shi

  • Open Access

    Prediction of Bridge Structural Response Based on Nonstationary Transformer

    by Qing Li, Zhixiang He, Wenxue Zhang, Zhuo Qiu

    Accurate prediction of bridge structural responses is crucial for infrastructure safety and maintenance. This study introduces the Nonstationary Transformer (NSFormer), a novel model designed to address the challenges posed by nonstationary data in bridge monitoring, characterized by trends, periodicity, and random fluctuations. Unlike traditional models such as LSTM and Transformer, NSFormer leverages a de‐stationary attention mechanism that dynamically adapts to changing temporal patterns, enabling robust long‐term prediction. Experimental results show that NSFormer consistently outperforms the traditional models across multiple datasets and prediction horizons. Specifically, at a 24‐step prediction horizon, NSFormer reduces mean absolute error by at least 22.88% for Deflection dataset and 66.67% for Strain‐All dataset. While predictive accuracy decreases with longer horizons, NSFormer maintains superior performance compared to alternatives. Furthermore, prediction accuracy remains stable across varying input horizons, demonstrating the model’s ability to effectively capture temporal dependencies despite data variability. These findings imply that NSFormer can significantly enhance the reliability of structural health monitoring systems by providing more accurate and stable prediction under complex, variable conditions, thereby supporting timely maintenance decisions and improving bridge safety management.


  • Open Access

    Equivalent Fatigue Constitutive Model Based on Fatigue Damage Evolution of Concrete

    by Huating Chen, Zhenyu Sun, Xianwei Zhang, Wenxue Zhang

    Concrete structures such as bridge decks and road pavements are subjected to repetitive loading and are susceptible to fatigue failure. A simplified stress–strain analysis method that can simulate concrete behavior with a sound physical basis, acceptable prediction precision, and reasonable computation cost is urgently needed to address the critical issue of high-cycle fatigue in structural engineering. An equivalent fatigue constitutive model at discrete loading cycles incorporated into the concrete damaged plasticity model (CDPM) in Abaqus is proposed based on fatigue damage evolution. A damage variable is constructed from maximum fatigue strains, and fatigue damage evolution is described by a general equation whose parameters’ physical meaning and value range are identified. With the descending branch of the monotonic stress–strain curve as the envelope of fatigue residual strength and fatigue damage evolution equation as shape function, fatigue residual strength, residual stiffness, and residual strain are calculated. The equivalent fatigue constitutive model is validated through comparison with experimental data, where satisfactory simulation results were obtained for axial compression and flexural tension fatigue. The model’s novelty lies in integrating the fatigue damage evolution equation with CDPM, explicitly explaining performance degradation caused by fatigue damage. The proposed model could accommodate various forms of concrete constitution and fatigue stress states and has a broad application prospect for fatigue analysis of concrete structures.


  • Open Access

    Seismic Performance Analysis of the Internal Joint in the New Demountable Fabricated Concrete Frame with Prestressed Mortise–Tenon Connections

    by Junwei Wang, Cheng Zhang, Wenxue Zhang

    This paper proposed a novel demountable fabricated joint in frame, which is connected by the prestressed and mortise–tenon connection. The prefabricated components of the demountable structures are designed to be reused, and the joint presented in this paper will promote the sustainable application of prefabricated components in future. The damage process and damage pattern of the internal joints under the horizontal load were analyzed using the refined numerical analysis model based on ABAQUS 6.14. Parametric analyses were conducted simultaneously for five parameters: axial compression ratio, the area and effective initial stress of unbonded prestressed strands (UPSs), the local reinforcement ratio in the core zone of the demountable joint, and the friction coefficient between the interface of concrete. The results showed that the demountable joint exhibits excellent energy dissipation potential under horizontal loads, but the damage was concentrated in the core zone. The deformation of the joint mainly consisted of the self-deformation of the prefabricated components, including bending, bearing and shear, as well as the relative slip deformation between the prefabricated components. The axial compression ratio has a more significant effect on the hysteresis performance compared to the areas of the UPSs and the reinforcement ratio. The initial effective stress of the UPS and the friction coefficient have relatively minor influence on the hysteretic performance of the joint. Finally, this paper recommends the design parameter values (axial compression ratio should not exceed 0.4, area of unbonded prestressed reinforcement should be not lower than Asn=0.02 and not higher than Asn=0.1, the initial stress of the UPS takes the value of 0.75fpu) and outlines optimization measures.