This study examines the axial compression performance of unbonded prestressed mortise–tenon beam–column joints (MTPC). The MTPC joint employs a mortise–tenon configuration, achieving tight compression through unbonded prestressed steel strands at the column's center, enhancing prefabrication efficiency. Three axial compression test models were fabricated and subjected to axial monotonic loading, with experimental phenomena and results analyzed. The results show the optimized MTPC joint achieves approximately 90% of the column‐end axial capacity, while MTPC joints reinforced with ultra‐high‐performance concrete (UHPC) surpass the column‐end capacity, fulfilling the “strong joints, weak components” design principle. Minor gaps during assembly require axial pressure for tight component contact, but the assembled joint demonstrates excellent integrity, stable axial stiffness, and effective load transfer. A calculation method for the axial load‐bearing capacity of MTPC joints is proposed, along with a finite element model. Comparison with experimental results validates the model's accuracy. Theoretical calculations, experimental data, and finite element analysis collectively confirm the proposed method effectively predicts the axial compression capacity and mechanical behavior of MTPC joints under axial loading. This research highlights the MTPC joint's potential for enhancing construction efficiency and structural performance in prefabricated systems.Keywords
Funding Information
- National Natural Science Foundation of China (52478112)
This publication has 31 references indexed in Scilit:
- Recent trends in ultra-high performance concrete (UHPC): Current status, challenges, and future prospectsConstruction and Building Materials, 2022
- Precast prestressed concrete frames for seismically retrofitting existing RC framesEngineering Structures, 2019
- Seismic performance of precast concrete column-to-column lap-splice connectionsEngineering Structures, 2018
- Seismic behavior of beam-column joints strengthened with ultra-high performance fiber reinforced concreteComposite Structures, 2018
- Numerical study on a fully-prefabricated damage-tolerant beam to column connection for an earthquake-resilient frameEngineering Structures, 2018
- Experimental and numerical study of the flexural behaviour of ultra-high performance fibre reinforced concrete beamsConstruction and Building Materials, 2017
- Pseudodynamic tests on a full-scale 3-storey precast concrete building: Global responseEngineering Structures, 2013
- Pseudodynamic tests on a full-scale 3-storey precast concrete building: Behavior of the mechanical connections and floor diaphragmsEngineering Structures, 2013
- The principle of Saint-Venant in linear and non-linear plane elasticityArchive for Rational Mechanics and Analysis, 1967