Caiqiao Xiong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Caiqiao Xiong has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Zongxiu Nie
Ningxia University
26 shared publications Yuze Li
State Key Laboratory of High-efficiency Utilization of Coal and Green Chemical Engineering, College of Chemistry and Chemical Engineering, Ningxia University, Yinchuan 750021, China
11 shared publicationsHuihui Liu
Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
9 shared publicationsJunyu Chen
Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
5 shared publications- Lingpeng Zhan
Institute for Cell Analysis Shenzhen Bay Laboratory Shenzhen China
5 shared publications Xiao Wang
Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
5 shared publications
Latest Publications
- 16 March 2026
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 37 (4) , 1027-1031
A Miniature Ion Trap Particle Mass Spectrometer with an Integrated Optical and Charge Detection System
A miniature ion trap particle mass spectrometer with both optical and charge detection systems was constructed in this work. The instrument was initially constructed with an open architecture and mounted on a 600 × 450 mm optical bench. With further compact integration, the system can be accommodated within an aluminum enclosure with dimensions of 333 × 221 × 192 mm and a total mass of approximately 8 kg. In the optical detection mode, the stationary star pattern ion motion was observed by detecting the scattered light, and the m/Z value of the particle ion was calculated accurately. In the charge detection mode, the particle m/Z value, the charge number Z, and the particle mass were determined quickly. These two working modes can be switched freely. By using 3 μm polystyrene size standards and mice red blood cells as the sample, the feasibility of this instrument was demonstrated.
- 16 March 2026
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 37 (4) , 1027-1031
A Miniature Ion Trap Particle Mass Spectrometer with an Integrated Optical and Charge Detection System
A miniature ion trap particle mass spectrometer with both optical and charge detection systems was constructed in this work. The instrument was initially constructed with an open architecture and mounted on a 600 × 450 mm optical bench. With further compact integration, the system can be accommodated within an aluminum enclosure with dimensions of 333 × 221 × 192 mm and a total mass of approximately 8 kg. In the optical detection mode, the stationary star pattern ion motion was observed by detecting the scattered light, and the m/Z value of the particle ion was calculated accurately. In the charge detection mode, the particle m/Z value, the charge number Z, and the particle mass were determined quickly. These two working modes can be switched freely. By using 3 μm polystyrene size standards and mice red blood cells as the sample, the feasibility of this instrument was demonstrated.
- 2 May 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (19) , 7360-7366
Desorption Separation Ionization Mass Spectrometry (DSI-MS) for Rapid Analysis of COVID-19
During the coronavirus disease 2019 (COVID-19) pandemic, which has witnessed over 772 million confirmed cases and over 6 million deaths globally, the outbreak of COVID-19 has emerged as a significant medical challenge affecting both affluent and impoverished nations. Therefore, there is an urgent need to explore the disease mechanism and to implement rapid detection methods. To address this, we employed the desorption separation ionization (DSI) device in conjunction with a mass spectrometer for the efficient detection and screening of COVID-19 urine samples. The study encompassed patients with COVID-19, healthy controls (HC), and patients with other types of pneumonia (OP) to evaluate their urine metabolomic profiles. Subsequently, we identified the differentially expressed metabolites in the COVID-19 patients and recognized amino acid metabolism as the predominant metabolic pathway involved. Furthermore, multiple established machine learning algorithms validated the exceptional performance of the metabolites in discriminating the COVID-19 group from healthy subjects, with an area under the curve of 0.932 in the blind test set. This study collectively suggests that the small-molecule metabolites detected from urine using the DSI device allow for rapid screening of COVID-19, taking just three minutes per sample. This approach has the potential to expand our understanding of the pathophysiological mechanisms of COVID-19 and offers a way to rapidly screen patients with COVID-19 through the utilization of machine learning algorithms.
- 2 May 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (19) , 7360-7366
Desorption Separation Ionization Mass Spectrometry (DSI-MS) for Rapid Analysis of COVID-19
During the coronavirus disease 2019 (COVID-19) pandemic, which has witnessed over 772 million confirmed cases and over 6 million deaths globally, the outbreak of COVID-19 has emerged as a significant medical challenge affecting both affluent and impoverished nations. Therefore, there is an urgent need to explore the disease mechanism and to implement rapid detection methods. To address this, we employed the desorption separation ionization (DSI) device in conjunction with a mass spectrometer for the efficient detection and screening of COVID-19 urine samples. The study encompassed patients with COVID-19, healthy controls (HC), and patients with other types of pneumonia (OP) to evaluate their urine metabolomic profiles. Subsequently, we identified the differentially expressed metabolites in the COVID-19 patients and recognized amino acid metabolism as the predominant metabolic pathway involved. Furthermore, multiple established machine learning algorithms validated the exceptional performance of the metabolites in discriminating the COVID-19 group from healthy subjects, with an area under the curve of 0.932 in the blind test set. This study collectively suggests that the small-molecule metabolites detected from urine using the DSI device allow for rapid screening of COVID-19, taking just three minutes per sample. This approach has the potential to expand our understanding of the pathophysiological mechanisms of COVID-19 and offers a way to rapidly screen patients with COVID-19 through the utilization of machine learning algorithms.
- 18 April 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (17) , 6511-6516
Accurate and High-Resolution Particle Mass Measurement Using a Peak Filtering Algorithm
Charge detection quadrupole ion trap mass spectrometry (CD-QIT MS) is an effective way of achieving the mass analysis of microparticles with ultrahigh mass. However, its mass accuracy and resolution are still poor. To enhance the performance of CD-QIT MS, the resolution Rpeak of each peak in the mass spectra resulting from an individual particle was assessed, and a peak filtering algorithm that can filter out particle adducts and clusters with a lower Rpeak was proposed. By using this strategy, more accurate mass information about the analyzed particles could be obtained, and the mass resolution of CD-QIT MS was improved by nearly 2-fold, which was demonstrated by using the polystyrene (PS) particle size standards and red blood cells (RBCs). Benefiting from these advantages of the peak filtering algorithm, the baseline separation and relative quantification of 3 and 4 μm PS particles were achieved. To prove the application value of this algorithm in a biological system, the mass of yeast cells harvested at different times was measured, and it was found that the mixed unbudded and budded yeast cells, which otherwise would not be differentiable, were distinguished and quantified with the algorithm.
- 18 April 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (17) , 6511-6516
Accurate and High-Resolution Particle Mass Measurement Using a Peak Filtering Algorithm
Charge detection quadrupole ion trap mass spectrometry (CD-QIT MS) is an effective way of achieving the mass analysis of microparticles with ultrahigh mass. However, its mass accuracy and resolution are still poor. To enhance the performance of CD-QIT MS, the resolution Rpeak of each peak in the mass spectra resulting from an individual particle was assessed, and a peak filtering algorithm that can filter out particle adducts and clusters with a lower Rpeak was proposed. By using this strategy, more accurate mass information about the analyzed particles could be obtained, and the mass resolution of CD-QIT MS was improved by nearly 2-fold, which was demonstrated by using the polystyrene (PS) particle size standards and red blood cells (RBCs). Benefiting from these advantages of the peak filtering algorithm, the baseline separation and relative quantification of 3 and 4 μm PS particles were achieved. To prove the application value of this algorithm in a biological system, the mass of yeast cells harvested at different times was measured, and it was found that the mixed unbudded and budded yeast cells, which otherwise would not be differentiable, were distinguished and quantified with the algorithm.
- 22 July 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 59 (65) , 9852-9855
Urine and serum metabolic profiling combined with machine learning for autoimmune disease discrimination and classification
MALDI-MS metabolic patterns of urine and serum combined with machine learning achieved the rapid discrimination and classification of autoimmune diseases, and the metabolic disorders caused by the diseases were also investigated.
- 22 July 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 59 (65) , 9852-9855
Urine and serum metabolic profiling combined with machine learning for autoimmune disease discrimination and classification
MALDI-MS metabolic patterns of urine and serum combined with machine learning achieved the rapid discrimination and classification of autoimmune diseases, and the metabolic disorders caused by the diseases were also investigated.
- 2 March 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (10) , 4612-4618
Pocket-Size Wireless Nanoelectrospray Ionization Mass Spectrometry for Metabolic Analysis of Salty Biofluids and Single Cells
Analysis of volume-limited biological samples such as single cells and biofluids not only benefits clinical purposes but also promotes fundamental research in life sciences. Detection of these samples, however, imposes strict requirements on measurement performance because of the minimal volume and concentrated salts of the samples. Herein, we developed a self-cleaning nanoelectrospray ionization device powered by a pocket-size "MasSpec Pointer" (MSP-nanoESI) for metabolic analysis of salty biological samples with limited volume. The self-cleaning effect induced by Maxwell-Wagner electric stress helps with keeping the borosilicate glass capillary tip free from clogging and thus increasing salt tolerance. This device possesses a high sample economy (about 0.1 μL per test) due to its pulsed high voltage supply, sampling method (dipping the nanoESI tip into analyte solution), and contact-free electrospray ionization (ESI) (the electrode does not touch the analyte solution during ESI). High repeatable results could be acquired by the device with a relative standard deviation (RSD) of 1.02% for voltage output and 12.94% for MS signals of caffeine standard. Single MCF-7 cells were metabolically analyzed directly from phosphate buffered saline, and two types of untreated cerebrospinal fluid from hydrocephalus patients were distinguished with 84% accuracy. MSP-nanoESI gets rid of the bulky apparatus and could be held in hand or put into one's pocket for transportation, and it could operate for more than 4 h without recharge. We believe this device will boost scientific research and clinical usage of volume-limited biological samples with high-concentration salts in a low-cost, convenient, and rapid manner.
- 2 March 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (10) , 4612-4618
Pocket-Size Wireless Nanoelectrospray Ionization Mass Spectrometry for Metabolic Analysis of Salty Biofluids and Single Cells
Analysis of volume-limited biological samples such as single cells and biofluids not only benefits clinical purposes but also promotes fundamental research in life sciences. Detection of these samples, however, imposes strict requirements on measurement performance because of the minimal volume and concentrated salts of the samples. Herein, we developed a self-cleaning nanoelectrospray ionization device powered by a pocket-size "MasSpec Pointer" (MSP-nanoESI) for metabolic analysis of salty biological samples with limited volume. The self-cleaning effect induced by Maxwell-Wagner electric stress helps with keeping the borosilicate glass capillary tip free from clogging and thus increasing salt tolerance. This device possesses a high sample economy (about 0.1 μL per test) due to its pulsed high voltage supply, sampling method (dipping the nanoESI tip into analyte solution), and contact-free electrospray ionization (ESI) (the electrode does not touch the analyte solution during ESI). High repeatable results could be acquired by the device with a relative standard deviation (RSD) of 1.02% for voltage output and 12.94% for MS signals of caffeine standard. Single MCF-7 cells were metabolically analyzed directly from phosphate buffered saline, and two types of untreated cerebrospinal fluid from hydrocephalus patients were distinguished with 84% accuracy. MSP-nanoESI gets rid of the bulky apparatus and could be held in hand or put into one's pocket for transportation, and it could operate for more than 4 h without recharge. We believe this device will boost scientific research and clinical usage of volume-limited biological samples with high-concentration salts in a low-cost, convenient, and rapid manner.
- 20 February 2023
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 17 (5) , 4463-4473
Revealing the In Situ Behavior of Aggregation-Induced Emission Nanoparticles and Their Biometabolic Effects via Mass Spectrometry Imaging
Simultaneous imaging of exogenous nanomaterials and endogenous metabolites in situ remains challenging and is beneficial for a systemic understanding of the biological behavior of nanomaterials at the molecular level. Here, combined with label-free mass spectrometry imaging, visualization and quantification of the aggregation-induced emission nanoparticles (NPs) in tissue were realized as well as related endogenous spatial metabolic changes simultaneously. Our approach enables us to identify the heterogeneous deposition and clearance behavior of nanoparticles in organs. The accumulation of nanoparticles in normal tissues results in distinct endogenous metabolic changes such as oxidative stress as indicated by glutathione depletion. The low passive delivery efficiency of nanoparticles to tumor foci suggested that the enrichment of NPs in tumors did not benefit from the abundant tumor vessels. Moreover, spatial-selective metabolic changes upon NPs mediated photodynamic therapy was identified, which enables understanding of the NPs induced apoptosis in the process of cancer therapy. This strategy allows us to simultaneously detect exogenous nanomaterials and endogenous metabolites in situ, hence to decipher spatial selective metabolic changes in drug delivery and cancer therapy processes.
- 20 February 2023
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 17 (5) , 4463-4473
Revealing the In Situ Behavior of Aggregation-Induced Emission Nanoparticles and Their Biometabolic Effects via Mass Spectrometry Imaging
Simultaneous imaging of exogenous nanomaterials and endogenous metabolites in situ remains challenging and is beneficial for a systemic understanding of the biological behavior of nanomaterials at the molecular level. Here, combined with label-free mass spectrometry imaging, visualization and quantification of the aggregation-induced emission nanoparticles (NPs) in tissue were realized as well as related endogenous spatial metabolic changes simultaneously. Our approach enables us to identify the heterogeneous deposition and clearance behavior of nanoparticles in organs. The accumulation of nanoparticles in normal tissues results in distinct endogenous metabolic changes such as oxidative stress as indicated by glutathione depletion. The low passive delivery efficiency of nanoparticles to tumor foci suggested that the enrichment of NPs in tumors did not benefit from the abundant tumor vessels. Moreover, spatial-selective metabolic changes upon NPs mediated photodynamic therapy was identified, which enables understanding of the NPs induced apoptosis in the process of cancer therapy. This strategy allows us to simultaneously detect exogenous nanomaterials and endogenous metabolites in situ, hence to decipher spatial selective metabolic changes in drug delivery and cancer therapy processes.
- 15 July 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (29) , 10367-10374
Biofluids Metabolic Profiling Based on PS@Fe3O4–NH2 Magnetic Beads-Assisted LDI-MS for Liver Cancer Screening
Liver cancer (LC) is the third frequent cause of death worldwide, so early diagnosis of liver cancer patients is crucial for disease management. Herein, we applied NH2-coated polystyrene@Fe3O4 magnetic beads (PS@Fe3O4-NH2 MBs) as a matrix material in laser desorption/ionization mass spectrometry (LDI-MS). Rapid, sensitive, and selective metabolic profiling of the native biofluids was achieved without any inconvenient enrichment or purification. Then, based on the selected m/z features, LC patients were discriminated from healthy controls (HCs) by machine learning, with the high area under the curve (AUC) values for urine and serum assessments (0.962 and 0.935). Moreover, initial-diagnosed and subsequent-visited LC patients were also differentiated, which indicates potential applications of this method in early diagnosis. Furthermore, among these identified compounds by FT-ICR MS, the expression level of some metabolites changed from HCs to LCs, including 29 and 12 characteristic metabolites in human urine and serum samples, respectively. These results suggest that PS@Fe3O4-NH2 MBs-assisted LDI-MS coupled with machine learning is feasible for LC clinical diagnosis.
- 15 July 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (29) , 10367-10374
Biofluids Metabolic Profiling Based on PS@Fe3O4–NH2 Magnetic Beads-Assisted LDI-MS for Liver Cancer Screening
Liver cancer (LC) is the third frequent cause of death worldwide, so early diagnosis of liver cancer patients is crucial for disease management. Herein, we applied NH2-coated polystyrene@Fe3O4 magnetic beads (PS@Fe3O4-NH2 MBs) as a matrix material in laser desorption/ionization mass spectrometry (LDI-MS). Rapid, sensitive, and selective metabolic profiling of the native biofluids was achieved without any inconvenient enrichment or purification. Then, based on the selected m/z features, LC patients were discriminated from healthy controls (HCs) by machine learning, with the high area under the curve (AUC) values for urine and serum assessments (0.962 and 0.935). Moreover, initial-diagnosed and subsequent-visited LC patients were also differentiated, which indicates potential applications of this method in early diagnosis. Furthermore, among these identified compounds by FT-ICR MS, the expression level of some metabolites changed from HCs to LCs, including 29 and 12 characteristic metabolites in human urine and serum samples, respectively. These results suggest that PS@Fe3O4-NH2 MBs-assisted LDI-MS coupled with machine learning is feasible for LC clinical diagnosis.
- 28 June 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (27) , 9894-9902
Profiling of Urine Carbonyl Metabolic Fingerprints in Bladder Cancer Based on Ambient Ionization Mass Spectrometry
The diagnosis of bladder cancer (BC) is currently based on cystoscopy, which is invasive and expensive. Here, we describe a noninvasive profiling method for carbonyl metabolic fingerprints in BC, which is based on a desorption, separation, and ionization mass spectrometry (DSI-MS) platform with N,N-dimethylethylenediamine (DMED) as a differential labeling reagent. The DSI-MS platform avoids the interferences from intra- and/or intersamples. Additionally, the DMED derivatization increases detection sensitivity and distinguishes carboxyl, aldehyde, and ketone groups in untreated urine samples. Carbonyl metabolic fingerprints of urine from 41 BC patients and 41 controls were portrayed and 9 potential biomarkers were identified. The mechanisms of the regulations of these biomarkers have been tentatively discussed. A logistic regression (LR) machine learning algorithm was applied to discriminate BC from controls, and an accuracy of 85% was achieved. We believe that the method proposed here may pave the way toward the point-of-care diagnosis of BC in a patient-friendly manner.
- 28 June 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (27) , 9894-9902
Profiling of Urine Carbonyl Metabolic Fingerprints in Bladder Cancer Based on Ambient Ionization Mass Spectrometry
The diagnosis of bladder cancer (BC) is currently based on cystoscopy, which is invasive and expensive. Here, we describe a noninvasive profiling method for carbonyl metabolic fingerprints in BC, which is based on a desorption, separation, and ionization mass spectrometry (DSI-MS) platform with N,N-dimethylethylenediamine (DMED) as a differential labeling reagent. The DSI-MS platform avoids the interferences from intra- and/or intersamples. Additionally, the DMED derivatization increases detection sensitivity and distinguishes carboxyl, aldehyde, and ketone groups in untreated urine samples. Carbonyl metabolic fingerprints of urine from 41 BC patients and 41 controls were portrayed and 9 potential biomarkers were identified. The mechanisms of the regulations of these biomarkers have been tentatively discussed. A logistic regression (LR) machine learning algorithm was applied to discriminate BC from controls, and an accuracy of 85% was achieved. We believe that the method proposed here may pave the way toward the point-of-care diagnosis of BC in a patient-friendly manner.
- 3 February 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (6) , 2686-2692
High Speed Mass Measurement of a Single Metal–Organic Framework Nanocrystal in a Paul Trap
Mass spectrometry (MS) has emerged as an excellent tool for the characterization of metal–organic frameworks (MOFs) based on the characteristic metal ions and organic ligands. Mass measurement of intact MOF nanocrystals, however, remains a challenge for MS technology. Here, we reported the development of a probe particles based charge detection-quadrupole ion trap mass spectrometry (probe CD-QIT MS) method, where charge detection and mass measurement of a single MOF nanocrystal were achieved under the assistance of probe particles of micrometer size. As a validation of the method, the masses of a series of polystyrene (PS) size standards from 493 nm to 1.6 μm were measured with 3 μm PS particles as probes, and the measured masses were found to match well with their certified masses. Then, charge detections and mass analysis of single ZIF-8 and [email protected] with a size around 600 nm were achieved successfully. The method presented here demonstrates simplicity, high speed, and accuracy. Notably, it allows quantitative measurement of the amount of immobilized GOx enzyme by using the mass difference between ZIF-8 and [email protected] In addition, based on the determined mass, the size analysis of these MOF particles with irregular shape was carried out and demonstrated to be complementary to transmission electron microscopy (TEM).
- 3 February 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (6) , 2686-2692
High Speed Mass Measurement of a Single Metal–Organic Framework Nanocrystal in a Paul Trap
Mass spectrometry (MS) has emerged as an excellent tool for the characterization of metal–organic frameworks (MOFs) based on the characteristic metal ions and organic ligands. Mass measurement of intact MOF nanocrystals, however, remains a challenge for MS technology. Here, we reported the development of a probe particles based charge detection-quadrupole ion trap mass spectrometry (probe CD-QIT MS) method, where charge detection and mass measurement of a single MOF nanocrystal were achieved under the assistance of probe particles of micrometer size. As a validation of the method, the masses of a series of polystyrene (PS) size standards from 493 nm to 1.6 μm were measured with 3 μm PS particles as probes, and the measured masses were found to match well with their certified masses. Then, charge detections and mass analysis of single ZIF-8 and [email protected] with a size around 600 nm were achieved successfully. The method presented here demonstrates simplicity, high speed, and accuracy. Notably, it allows quantitative measurement of the amount of immobilized GOx enzyme by using the mass difference between ZIF-8 and [email protected] In addition, based on the determined mass, the size analysis of these MOF particles with irregular shape was carried out and demonstrated to be complementary to transmission electron microscopy (TEM).
- 26 September 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (39) , 13326-13333
Pocket-Size “MasSpec Pointer” for Ambient Ionization Mass Spectrometry
Current ambient ionization sources for mass spectrometry (MS) are typically connected to gas cylinders, high-voltage supply, injection pump, and other accessory equipment, which hinder the popularization of MS in the field of on-site detection. Here, we developed a wireless pocket-size “MasSpec Pointer” (weights 65 g) based on arc discharge powered by a 3.7 V polymer Li battery for ambient ionization MS. A high voltage of 5600 V and 20 kHz was generated from the boost coil to penetrate air and form a plasma. The relative standard deviation (RSD) of the high-voltage pulses is 3.8%, leading to a stable discharge and a good quantification performance. A mini diaphragm pump was used to cool the plasma from ∼600 to ∼40 °C and to blow the plasma into a jet, which facilitates sampling. MasSpec Pointer can work well at both positive- and negative-ion modes without any modification and can quickly test gaseous, liquid, or solid samples. The limit of detection of this device for atrazine (an agrochemical) is lower than 0.1 ng/mL. MasSpec Pointer has shown its ability to pinpoint the double-bond location of fatty acid isomers without derivatization reagents or light illumination. Agrochemicals from the surface of an apple and daily chemicals from the surface of a finger were detected successfully using MasSpec Pointer coupled with a miniature mass spectrometer. We believe the “point-and-shoot” device coupled with mini-MS brings the hope for an age of detecting chemicals on-site by nonprofessionals.
- 26 September 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (39) , 13326-13333
Pocket-Size “MasSpec Pointer” for Ambient Ionization Mass Spectrometry
Current ambient ionization sources for mass spectrometry (MS) are typically connected to gas cylinders, high-voltage supply, injection pump, and other accessory equipment, which hinder the popularization of MS in the field of on-site detection. Here, we developed a wireless pocket-size “MasSpec Pointer” (weights 65 g) based on arc discharge powered by a 3.7 V polymer Li battery for ambient ionization MS. A high voltage of 5600 V and 20 kHz was generated from the boost coil to penetrate air and form a plasma. The relative standard deviation (RSD) of the high-voltage pulses is 3.8%, leading to a stable discharge and a good quantification performance. A mini diaphragm pump was used to cool the plasma from ∼600 to ∼40 °C and to blow the plasma into a jet, which facilitates sampling. MasSpec Pointer can work well at both positive- and negative-ion modes without any modification and can quickly test gaseous, liquid, or solid samples. The limit of detection of this device for atrazine (an agrochemical) is lower than 0.1 ng/mL. MasSpec Pointer has shown its ability to pinpoint the double-bond location of fatty acid isomers without derivatization reagents or light illumination. Agrochemicals from the surface of an apple and daily chemicals from the surface of a finger were detected successfully using MasSpec Pointer coupled with a miniature mass spectrometer. We believe the “point-and-shoot” device coupled with mini-MS brings the hope for an age of detecting chemicals on-site by nonprofessionals.