Christian Eberhardt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christian Eberhardt has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Moritz Christoph Wurnig
Institute of Diagnostic and Interventional Radiology, University Hospital Zürich, Switzerland
5 shared publications - Andreas Boss
Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
4 shared publications - Cristina Rossi
Institute of Diagnostic and Interventional Radiology, University Hospital Zürich, Switzerland
4 shared publications - Mickael Lesurtel
Department of HPB Surgery and Liver Transplantation, APHP-Beaujon Hospital, Université Paris Cité, Paris, France
4 shared publications - Daniel Eberli
Department of Urology, University Hospital of Zürich, Zürich, Switzerland
2 shared publications Markus Klarhoefer
Siemens Healthcare AG, Zürich, Switzerland
2 shared publications
Latest Publications
- 9 August 2019
- Published by Wiley in NMR in Biomedicine
- Vol. 32 (11) , e4159
Diffusion tensor imaging of the abdominal organs: Influence of oriented intravoxel flow compartments
Water flow in partially oriented intravoxel compartments mimics an anisotropic fast‐diffusion regime, which contributes to the signal attenuation in diffusion‐weighted images. In the abdominal organs, this flow may reflect physiological fluid movements (eg, tubular urine flow in kidneys, or bile flow through the liver) and have a clinical relevance. This study investigated the influence of anisotropic intravoxel water flow on diffusion tensor imaging (DTI) of the abdominal organs.Diffusion‐weighted images were acquired in five healthy volunteers using an EPI sequence with diffusion preparation (TR/TE: 1000 ms/71 ms; b‐values: 0, 10, 20, 40, 70, 120, 250, 450, 700, 1000 s/mm2; 12 noncollinear diffusion‐encoding directions). DTI of liver and kidneys was performed assuming (i) monoexponential decay of the diffusion‐weighted signal, and (ii) accounting for potential anisotropy of the fast‐diffusion compartments using a tensorial generalization of the IVIM model. Additionally, potential dependency of the metrics of the tensors from the anatomical location was evaluated.Significant differences in the metrics of the diffusion tensor (DT) were found in both liver and kidneys when comparing the two models. In both organs, the trace and the fractional anisotropy of the DT were significantly higher in the monoexponential model than when accounting for perfusion. The comparison of areas of the liver proximal to the hilum with distal regions and of renal cortex with the medulla also proved a location dependency of the size of the fast‐diffusion compartments.Pseudo‐diffusion correction in DTI enables the assessment of the solid parenchyma regardless of the organ perfusion or other pseudo‐diffusive fluid movements. This may have a clinical relevance in the assessment of parenchymal pathologies (eg, liver fibrosis). The fast pseudo‐diffusion components present a detectable anisotropy, which may reflect the hepatic microcirculation or other sources of mesoscopic fluid movement in the abdominal organs.
- 9 August 2019
- Published by Wiley in NMR in Biomedicine
- Vol. 32 (11) , e4159
Diffusion tensor imaging of the abdominal organs: Influence of oriented intravoxel flow compartments
Water flow in partially oriented intravoxel compartments mimics an anisotropic fast‐diffusion regime, which contributes to the signal attenuation in diffusion‐weighted images. In the abdominal organs, this flow may reflect physiological fluid movements (eg, tubular urine flow in kidneys, or bile flow through the liver) and have a clinical relevance. This study investigated the influence of anisotropic intravoxel water flow on diffusion tensor imaging (DTI) of the abdominal organs.Diffusion‐weighted images were acquired in five healthy volunteers using an EPI sequence with diffusion preparation (TR/TE: 1000 ms/71 ms; b‐values: 0, 10, 20, 40, 70, 120, 250, 450, 700, 1000 s/mm2; 12 noncollinear diffusion‐encoding directions). DTI of liver and kidneys was performed assuming (i) monoexponential decay of the diffusion‐weighted signal, and (ii) accounting for potential anisotropy of the fast‐diffusion compartments using a tensorial generalization of the IVIM model. Additionally, potential dependency of the metrics of the tensors from the anatomical location was evaluated.Significant differences in the metrics of the diffusion tensor (DT) were found in both liver and kidneys when comparing the two models. In both organs, the trace and the fractional anisotropy of the DT were significantly higher in the monoexponential model than when accounting for perfusion. The comparison of areas of the liver proximal to the hilum with distal regions and of renal cortex with the medulla also proved a location dependency of the size of the fast‐diffusion compartments.Pseudo‐diffusion correction in DTI enables the assessment of the solid parenchyma regardless of the organ perfusion or other pseudo‐diffusive fluid movements. This may have a clinical relevance in the assessment of parenchymal pathologies (eg, liver fibrosis). The fast pseudo‐diffusion components present a detectable anisotropy, which may reflect the hepatic microcirculation or other sources of mesoscopic fluid movement in the abdominal organs.
- 1 October 2018
- Published by Elsevier in The American Journal of Surgery
- Vol. 216 (4) , 658-665
Transient steatosis assessed by magnetic resonance imaging predicts outcome after extended hepatectomy in mice
- 1 October 2018
- Published by Elsevier in The American Journal of Surgery
- Vol. 216 (4) , 658-665
Transient steatosis assessed by magnetic resonance imaging predicts outcome after extended hepatectomy in mice
- Open Access
- 14 February 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (2) , e0192847
Prediction of small for size syndrome after extended hepatectomy: Tissue characterization by relaxometry, diffusion weighted magnetic resonance imaging and magnetization transfer
This study aimed to monitor the course of liver regeneration by multiparametric magnetic-resonance imaging (MRI) after partial liver resection characterizing Small-for-Size Syndrome (SFSS), which frequently leads to fatal post-hepatectomy liver failure (PLF). Twenty-two C57BL/6 mice underwent either conventional 70% partial hepatectomy (cPH), extended 86% partial hepatectomy (ePH) or SHAM operation. Subsequent MRI scans on days 0, 1, 2, 3, 5 and 7 in a 4.7T MR Scanner quantified longitudinal and transverse relaxation times, apparent diffusion coefficient (ADC) and the magnetization-transfer ratio (MTR) of the regenerating liver parenchyma. Histological examination was performed by hematoxylin-eosin staining. After hepatectomy, an increase of T1 time was detected being larger for ePH on day 1: 18% for cPH vs. 40% for ePH and on day 2: 24% for cPH vs. 49% for ePH. An increase in T2 time, again greater in ePH was most pronounced on day 5: 21% for cPH vs. 41% for ePH. ADC and MTR showed a decrease on day 1: 21% for ePH vs. 13% for cPH for ADC, 15% for ePH vs. 11% for cPH for MTR. Subsequently, all MR parameters converged towards initial values in surviving animals. Dying PLF animals exhibited the strongest increase of T1 relaxation time and most prominent decreases of ADC and MTR. The retrieved MRI biomarkers indicate SFSS and potentially developing PLF at an early stage, likely reflecting cellular hypertrophy with extended water content and concomitantly diluted cellular components as features of liver regeneration, appearing more intense in ePH as compared to cPH.
- 14 February 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (2) , e0192847
Open AccessPrediction of small for size syndrome after extended hepatectomy: Tissue characterization by relaxometry, diffusion weighted magnetic resonance imaging and magnetization transfer
This study aimed to monitor the course of liver regeneration by multiparametric magnetic-resonance imaging (MRI) after partial liver resection characterizing Small-for-Size Syndrome (SFSS), which frequently leads to fatal post-hepatectomy liver failure (PLF). Twenty-two C57BL/6 mice underwent either conventional 70% partial hepatectomy (cPH), extended 86% partial hepatectomy (ePH) or SHAM operation. Subsequent MRI scans on days 0, 1, 2, 3, 5 and 7 in a 4.7T MR Scanner quantified longitudinal and transverse relaxation times, apparent diffusion coefficient (ADC) and the magnetization-transfer ratio (MTR) of the regenerating liver parenchyma. Histological examination was performed by hematoxylin-eosin staining. After hepatectomy, an increase of T1 time was detected being larger for ePH on day 1: 18% for cPH vs. 40% for ePH and on day 2: 24% for cPH vs. 49% for ePH. An increase in T2 time, again greater in ePH was most pronounced on day 5: 21% for cPH vs. 41% for ePH. ADC and MTR showed a decrease on day 1: 21% for ePH vs. 13% for cPH for ADC, 15% for ePH vs. 11% for cPH for MTR. Subsequently, all MR parameters converged towards initial values in surviving animals. Dying PLF animals exhibited the strongest increase of T1 relaxation time and most prominent decreases of ADC and MTR. The retrieved MRI biomarkers indicate SFSS and potentially developing PLF at an early stage, likely reflecting cellular hypertrophy with extended water content and concomitantly diluted cellular components as features of liver regeneration, appearing more intense in ePH as compared to cPH.
- Open Access
- 1 May 2017
- Published by Elsevier in NeuroImage
- Vol. 152, 340-347
The IVIM signal in the healthy cerebral gray matter: A play of spherical and non-spherical components
- 1 May 2017
- Published by Elsevier in NeuroImage
- Vol. 152, 340-347
Open AccessThe IVIM signal in the healthy cerebral gray matter: A play of spherical and non-spherical components
- 1 April 2017
- Published by Elsevier in Gastroenterology
- Vol. 152 (5) , S1048
Early Mri-Based Liver Fat Quantificationpredicts Outcome After Extended Hepatectomy in Mice
- 1 April 2017
- Published by Elsevier in Gastroenterology
- Vol. 152 (5) , S1048
Early Mri-Based Liver Fat Quantificationpredicts Outcome After Extended Hepatectomy in Mice
- Open Access
- 23 January 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (1) , e0170285
Proteomic Analysis of Kveim Reagent Identifies Targets of Cellular Immunity in Sarcoidosis
Kveim-reagent (Kv) skin testing was a historical method of diagnosing sarcoidosis. Intradermal injection of treated sarcoidosis spleen tissue resulted in a granuloma response at injection site by 4–6 weeks. Previous work indicates proteins as the possible trigger of this reaction. We aimed to identify Kv-specific proteins and characterise the ex vivo response of Peripheral Blood Mononuclear Cells (PBMCs) from sarcoidosis, tuberculosis and healthy control patients when stimulated with both Kv and selected Kv-specific proteins. Kv extracts were separated by 1D-SDS-PAGE and 2D-DIGE and then underwent mass spectrometric analysis for protein identification. Sarcoidosis and control PBMCs were first stimulated with Kv and then with three selected recombinant protein candidates which were identified from the proteomic analysis. PBMC secreted cytokines were subsequently measured by Multiplex Cytokine Assay. We observed significantly increased IFN-γ and TNF-α secretion from Kv-stimulated PBMCs of sarcoidosis patients vs. PBMCs from healthy volunteers (IFN-γ: 207.2 pg/mL vs. 3.86 pg/mL, p = 0.0018; TNF-α: 2375 pg/mL vs. 42.82 pg/mL, p = 0.0003). Through proteomic approaches we then identified 74 sarcoidosis tissue-specific proteins. Of these, 3 proteins (vimentin, tubulin and alpha-actinin-4) were identified using both 1D-SDS-PAGE and 2D-DIGE. Data are available via ProteomeXchange with identifier PXD005150. Increased cytokine secretion was subsequently observed with vimentin stimulation of sarcoidosis PBMCs vs. tuberculosis PBMCs (IFN-γ: 396.6 pg/mL vs 0.1 pg/mL, p = 0.0009; TNF-α: 1139 pg/mL vs 0.1 pg/mL, pp = 0.014; TNF-α: 1139 pg/mL vs 42.29 pg/mL, p = 0.027). No difference was found in cytokine secretion between sarcoidosis and control PBMCs when stimulated with either tubulin or alpha-actinin-4. Stimulation with both Kveim reagent and vimentin induces a specific pro-inflammatory cytokine secretion from sarcoidosis PBMCs. Further investigation of cellular immune responses to Kveim-specific proteins may identify novel biomarkers to assist the diagnosis of sarcoidosis.
- 23 January 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (1) , e0170285
Open AccessProteomic Analysis of Kveim Reagent Identifies Targets of Cellular Immunity in Sarcoidosis
Kveim-reagent (Kv) skin testing was a historical method of diagnosing sarcoidosis. Intradermal injection of treated sarcoidosis spleen tissue resulted in a granuloma response at injection site by 4–6 weeks. Previous work indicates proteins as the possible trigger of this reaction. We aimed to identify Kv-specific proteins and characterise the ex vivo response of Peripheral Blood Mononuclear Cells (PBMCs) from sarcoidosis, tuberculosis and healthy control patients when stimulated with both Kv and selected Kv-specific proteins. Kv extracts were separated by 1D-SDS-PAGE and 2D-DIGE and then underwent mass spectrometric analysis for protein identification. Sarcoidosis and control PBMCs were first stimulated with Kv and then with three selected recombinant protein candidates which were identified from the proteomic analysis. PBMC secreted cytokines were subsequently measured by Multiplex Cytokine Assay. We observed significantly increased IFN-γ and TNF-α secretion from Kv-stimulated PBMCs of sarcoidosis patients vs. PBMCs from healthy volunteers (IFN-γ: 207.2 pg/mL vs. 3.86 pg/mL, p = 0.0018; TNF-α: 2375 pg/mL vs. 42.82 pg/mL, p = 0.0003). Through proteomic approaches we then identified 74 sarcoidosis tissue-specific proteins. Of these, 3 proteins (vimentin, tubulin and alpha-actinin-4) were identified using both 1D-SDS-PAGE and 2D-DIGE. Data are available via ProteomeXchange with identifier PXD005150. Increased cytokine secretion was subsequently observed with vimentin stimulation of sarcoidosis PBMCs vs. tuberculosis PBMCs (IFN-γ: 396.6 pg/mL vs 0.1 pg/mL, p = 0.0009; TNF-α: 1139 pg/mL vs 0.1 pg/mL, pp = 0.014; TNF-α: 1139 pg/mL vs 42.29 pg/mL, p = 0.027). No difference was found in cytokine secretion between sarcoidosis and control PBMCs when stimulated with either tubulin or alpha-actinin-4. Stimulation with both Kveim reagent and vimentin induces a specific pro-inflammatory cytokine secretion from sarcoidosis PBMCs. Further investigation of cellular immune responses to Kveim-specific proteins may identify novel biomarkers to assist the diagnosis of sarcoidosis.
- 26 April 2016
- Published by Wiley in NMR in Biomedicine
- Vol. 29 (7) , 866-872
Separation of collagen-bound and porous bone water transverse relaxation in mice: proposal of a multi-step approach
The separation and quantification of collagen-bound water (CBW) and pore water (PW) components of the cortical bone signal are important because of their different contribution to bone mechanical properties. Ultrashort TE (UTE) imaging can be used to exploit the transverse relaxation from CBW and PW, allowing their quantification. We tested, for the first time, the feasibility of UTE measurements in mice for the separation and quantification of the transverse relaxation of CBW and PW in vivo using three different approaches for T2* determination. UTE sequences were acquired at 4.7 T in six mice with 10 different TEs (50–5000 μs). The transverse relaxation time T2* of CBW (T2*cbw) and PW (T2*pw) and the CBW fraction (bwf) were computed using a mono-exponential (i), a standard bi-exponential (ii) and a new multi-step bi-exponential (iii) approach. Regions of interest were drawn at multiple levels of the femur and vertebral body cortical bone for each mouse. The sum of the normalized squared residuals (Res) and the homogeneity of variance were tested to compare the different methods. In the femur, approach (i) yielded mean T2* ± standard deviation (SD) of 657 ± 234 μs. With approach (ii), T2*cbw, T2*pw and bwf were 464 ± 153 μs, 15 777 ± 10 864 μs and 57.6 ± 9.9%, respectively. For approach (iii), T2*cbw, T2*pw and bwf were 387 ± 108 μs, 7534 ± 2765 μs and 42.5 ± 6.2%, respectively. Similar values were obtained from vertebral bodies. Res with approach (ii) was lower than with the two other approaches (p < 0.007), but T2*pw and bwf variance was lower with approach (iii) than with approach (ii) (p < 0.048). We demonstrated that the separation and quantification of cortical bone water components with UTE sequences is feasible in vivo in mouse models. The direct bi-exponential approach exhibited the best approximation to the measured signal curve with the lowest residuals; however, the newly proposed multi-step algorithm resulted in substantially lower variability of the computed parameters. Copyright © 2016 John Wiley & Sons, Ltd.
- 26 April 2016
- Published by Wiley in NMR in Biomedicine
- Vol. 29 (7) , 866-872
Separation of collagen-bound and porous bone water transverse relaxation in mice: proposal of a multi-step approach
The separation and quantification of collagen-bound water (CBW) and pore water (PW) components of the cortical bone signal are important because of their different contribution to bone mechanical properties. Ultrashort TE (UTE) imaging can be used to exploit the transverse relaxation from CBW and PW, allowing their quantification. We tested, for the first time, the feasibility of UTE measurements in mice for the separation and quantification of the transverse relaxation of CBW and PW in vivo using three different approaches for T2* determination. UTE sequences were acquired at 4.7 T in six mice with 10 different TEs (50–5000 μs). The transverse relaxation time T2* of CBW (T2*cbw) and PW (T2*pw) and the CBW fraction (bwf) were computed using a mono-exponential (i), a standard bi-exponential (ii) and a new multi-step bi-exponential (iii) approach. Regions of interest were drawn at multiple levels of the femur and vertebral body cortical bone for each mouse. The sum of the normalized squared residuals (Res) and the homogeneity of variance were tested to compare the different methods. In the femur, approach (i) yielded mean T2* ± standard deviation (SD) of 657 ± 234 μs. With approach (ii), T2*cbw, T2*pw and bwf were 464 ± 153 μs, 15 777 ± 10 864 μs and 57.6 ± 9.9%, respectively. For approach (iii), T2*cbw, T2*pw and bwf were 387 ± 108 μs, 7534 ± 2765 μs and 42.5 ± 6.2%, respectively. Similar values were obtained from vertebral bodies. Res with approach (ii) was lower than with the two other approaches (p < 0.007), but T2*pw and bwf variance was lower with approach (iii) than with approach (ii) (p < 0.048). We demonstrated that the separation and quantification of cortical bone water components with UTE sequences is feasible in vivo in mouse models. The direct bi-exponential approach exhibited the best approximation to the measured signal curve with the lowest residuals; however, the newly proposed multi-step algorithm resulted in substantially lower variability of the computed parameters. Copyright © 2016 John Wiley & Sons, Ltd.
- 19 April 2016
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 29 (5) , 751-763
Intravoxel incoherent motion analysis of abdominal organs: computation of reference parameters in a large cohort of C57Bl/6 mice and correlation to microvessel density
Objective Diffusion-weighted magnetic resonance imaging (DW-MRI) combined with intravoxel incoherent motion (IVIM) analysis may be applied for assessment of organ lesions, diffuse parenchymal pathologies, and therapy monitoring. The aim of this study was to determine IVIM reference parameters of abdominal organs for translational research in a large cohort of C57Bl/6 laboratory mice. Materials and methods Anesthetized mice (n = 29) were measured in a 4.7 T small-animal MR scanner with a diffusion-weighted echo-planar imaging sequence at the \(b\)-values 0, 13, 24, 55, 107, 260, 514, 767, 1020 s/mm2. IVIM analysis was conducted on the liver, spleen, renal medulla and cortex, pancreas, and small bowel with computation of the true tissue diffusion coefficient \(D_{\text{t}}\), the perfusion fraction \(f_{\text{p}}\), and the pseudodiffusion coefficient \(D_{\text{p}}\). Microvessel density (MVD) was assessed by immunohistochemistry (IHC) against panendothelial cell antigen CD31. Results Mean values of the different organs [\(D_{\text{t}}\) (10−3 mm2/s); \(f_{\text{p}}\) (%); \(D_{\text{p}}\) (10−3 mm2/s); MVD (MV/mm2)]: liver 1.15 ± 0.14; 14.77 ± 6.15; 50.28 ± 33.21, 2008.48 ± 419.43, spleen 0.55 ± 0.12; 9.89 ± 5.69; 24.46 ± 17.31; n.d., renal medulla 1.50 ± 0.20; 14.63 ± 4.07; 35.50 ± 18.01; 1231.88 ± 290.61, renal cortex 1.34 ± 0.18; 10.83 ± 3.70; 16.74 ± 6.74; 810.09 ± 193.50, pancreas 1.23 ± 0.22; 20.12 ± 7.46; 29.35 ± 17.82, 591.15 ± 86.25 and small bowel 1.06 ± 0.13; 16.48 ± 3.63; 15.31 ± 7.00; 420.50 ± 168.42. Unlike \(D_{\text{t}}\) and \(f_{\text{p}}\), \(D_{\text{p}}\) correlates significantly with MVD (r = 0.90, p = 0.037). Conclusion This systematic evaluation of murine abdominal organs with IVIM and MVD analysis allowed to establish reference parameters for future DW-MRI translational research studies on small-animal disease models.- 19 April 2016
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 29 (5) , 751-763
Intravoxel incoherent motion analysis of abdominal organs: computation of reference parameters in a large cohort of C57Bl/6 mice and correlation to microvessel density
Objective Diffusion-weighted magnetic resonance imaging (DW-MRI) combined with intravoxel incoherent motion (IVIM) analysis may be applied for assessment of organ lesions, diffuse parenchymal pathologies, and therapy monitoring. The aim of this study was to determine IVIM reference parameters of abdominal organs for translational research in a large cohort of C57Bl/6 laboratory mice. Materials and methods Anesthetized mice (n = 29) were measured in a 4.7 T small-animal MR scanner with a diffusion-weighted echo-planar imaging sequence at the \(b\)-values 0, 13, 24, 55, 107, 260, 514, 767, 1020 s/mm2. IVIM analysis was conducted on the liver, spleen, renal medulla and cortex, pancreas, and small bowel with computation of the true tissue diffusion coefficient \(D_{\text{t}}\), the perfusion fraction \(f_{\text{p}}\), and the pseudodiffusion coefficient \(D_{\text{p}}\). Microvessel density (MVD) was assessed by immunohistochemistry (IHC) against panendothelial cell antigen CD31. Results Mean values of the different organs [\(D_{\text{t}}\) (10−3 mm2/s); \(f_{\text{p}}\) (%); \(D_{\text{p}}\) (10−3 mm2/s); MVD (MV/mm2)]: liver 1.15 ± 0.14; 14.77 ± 6.15; 50.28 ± 33.21, 2008.48 ± 419.43, spleen 0.55 ± 0.12; 9.89 ± 5.69; 24.46 ± 17.31; n.d., renal medulla 1.50 ± 0.20; 14.63 ± 4.07; 35.50 ± 18.01; 1231.88 ± 290.61, renal cortex 1.34 ± 0.18; 10.83 ± 3.70; 16.74 ± 6.74; 810.09 ± 193.50, pancreas 1.23 ± 0.22; 20.12 ± 7.46; 29.35 ± 17.82, 591.15 ± 86.25 and small bowel 1.06 ± 0.13; 16.48 ± 3.63; 15.31 ± 7.00; 420.50 ± 168.42. Unlike \(D_{\text{t}}\) and \(f_{\text{p}}\), \(D_{\text{p}}\) correlates significantly with MVD (r = 0.90, p = 0.037). Conclusion This systematic evaluation of murine abdominal organs with IVIM and MVD analysis allowed to establish reference parameters for future DW-MRI translational research studies on small-animal disease models.- Open Access
- 1 March 2016
- Published by Elsevier in Journal of Bone Oncology
- Vol. 5 (1) , 1-4
Ibandronate: The loading dose concept in the treatment of metastatic bone pain
- 1 March 2016
- Published by Elsevier in Journal of Bone Oncology
- Vol. 5 (1) , 1-4
Open AccessIbandronate: The loading dose concept in the treatment of metastatic bone pain