Werner Baumann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Werner Baumann has a total of 125 co-authors. Here are the top co-authors by number of shared publications:
- Jan Gimsa
Department of Biophysics, University of Rostock, Gertrudenstr. 11A, 18057 Rostock, Germany
14 shared publications Ralf Ehret
Bionas GmbH, Friedrich-Barnewitz-Str. 3, 18119 Rostock, Germany
12 shared publicationsMartin Brischwein
11 shared publicationsBernhard Wolf
10 shared publicationsMirko Lehmann
Micronas GmbH, Hans-Bunte-Str. 19, 79108 Freiburg, Germany
9 shared publicationsMichael Kraus
7 shared publications
Latest Publications
- Open Access
- 1 July 2017
- Published by Elsevier in Biochemistry and Biophysics Reports
- Vol. 10, 17-25
Increased osteoblast viability at alkaline pH in vitro provides a new perspective on bone regeneration
- 1 July 2017
- Published by Elsevier in Biochemistry and Biophysics Reports
- Vol. 10, 17-25
Open AccessIncreased osteoblast viability at alkaline pH in vitro provides a new perspective on bone regeneration
- Open Access
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 547-551
Enhancing the regeneration of bone defects by alkalizing the peri-implant zone – anin vitroapproach
The effects of alkaline pH on the initial adhesion of osteoblasts to titanium surfaces was analyzed by single cell force microscopy (SCFM). In the SCFM measurements, the same cells were used to compare their unspecific adhesion to uncoated titanium with their specific adhesion to collagen coated titanium. When the maximum detachment forces (MDFs) were compared at pH 7.4 and 8.0, only slight differences were found on pure titanium, while the MDFs were significantly increased at collagen coated surfaces at pH 8.0. Effects on the subsequent proliferation and gene expression were investigated in anin vitromodel system consisting of an alkalizing polyvinyl alcohol (PVA) matrix and a perforated titanium disc. The sodium hydroxide releasing matrix maintained the medium pH between pH 7.6 and pH 8.4 during the entire experiment. Under these conditions, cell counts were significantly increased with respect to the control system after 7 days in culture. These results were supported by gene expression analyses, which showed an upregulation of proliferation-controlling genes of the EGFR1 and PI3K/AKT pathways after 14 days in culture. The SCFM data were complemented by findings of an intensive regulation of genes known to be associated with focal adhesion such as Itga8 and Tnn.
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 547-551
Open AccessEnhancing the regeneration of bone defects by alkalizing the peri-implant zone – anin vitroapproach
The effects of alkaline pH on the initial adhesion of osteoblasts to titanium surfaces was analyzed by single cell force microscopy (SCFM). In the SCFM measurements, the same cells were used to compare their unspecific adhesion to uncoated titanium with their specific adhesion to collagen coated titanium. When the maximum detachment forces (MDFs) were compared at pH 7.4 and 8.0, only slight differences were found on pure titanium, while the MDFs were significantly increased at collagen coated surfaces at pH 8.0. Effects on the subsequent proliferation and gene expression were investigated in anin vitromodel system consisting of an alkalizing polyvinyl alcohol (PVA) matrix and a perforated titanium disc. The sodium hydroxide releasing matrix maintained the medium pH between pH 7.6 and pH 8.4 during the entire experiment. Under these conditions, cell counts were significantly increased with respect to the control system after 7 days in culture. These results were supported by gene expression analyses, which showed an upregulation of proliferation-controlling genes of the EGFR1 and PI3K/AKT pathways after 14 days in culture. The SCFM data were complemented by findings of an intensive regulation of genes known to be associated with focal adhesion such as Itga8 and Tnn.
- Open Access
- 24 June 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (7) , 106
Cell Monitoring and Manipulation Systems (CMMSs) based on Glass Cell-Culture Chips (GC3s)
We developed different types of glass cell-culture chips (GC3s) for culturing cells for microscopic observation in open media-containing troughs or in microfluidic structures. Platinum sensor and manipulation structures were used to monitor physiological parameters and to allocate and permeabilize cells. Electro-thermal micro pumps distributed chemical compounds in the microfluidic systems. The integrated temperature sensors showed a linear, Pt1000-like behavior. Cell adhesion and proliferation were monitored using interdigitated electrode structures (IDESs). The cell-doubling times of primary murine embryonic neuronal cells (PNCs) were determined based on the IDES capacitance-peak shifts. The electrical activity of PNC networks was detected using multi-electrode arrays (MEAs). During seeding, the cells were dielectrophoretically allocated to individual MEAs to improve network structures. MEA pads with diameters of 15, 20, 25, and 35 µm were tested. After 3 weeks, the magnitudes of the determined action potentials were highest for pads of 25 µm in diameter and did not differ when the inter-pad distances were 100 or 170 µm. Using 25-µm diameter circular oxygen electrodes, the signal currents in the cell-culture media were found to range from approximately −0.08 nA (0% O2) to −2.35 nA (21% O2). It was observed that 60-nm thick silicon nitride-sensor layers were stable potentiometric pH sensors under cell-culture conditions for periods of days. Their sensitivity between pH 5 and 9 was as high as 45 mV per pH step. We concluded that sensorized GC3s are potential animal replacement systems for purposes such as toxicity pre-screening. For example, the effect of mefloquine, a medication used to treat malaria, on the electrical activity of neuronal cells was determined in this study using a GC3 system.
- 24 June 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (7) , 106
Open AccessCell Monitoring and Manipulation Systems (CMMSs) based on Glass Cell-Culture Chips (GC3s)
We developed different types of glass cell-culture chips (GC3s) for culturing cells for microscopic observation in open media-containing troughs or in microfluidic structures. Platinum sensor and manipulation structures were used to monitor physiological parameters and to allocate and permeabilize cells. Electro-thermal micro pumps distributed chemical compounds in the microfluidic systems. The integrated temperature sensors showed a linear, Pt1000-like behavior. Cell adhesion and proliferation were monitored using interdigitated electrode structures (IDESs). The cell-doubling times of primary murine embryonic neuronal cells (PNCs) were determined based on the IDES capacitance-peak shifts. The electrical activity of PNC networks was detected using multi-electrode arrays (MEAs). During seeding, the cells were dielectrophoretically allocated to individual MEAs to improve network structures. MEA pads with diameters of 15, 20, 25, and 35 µm were tested. After 3 weeks, the magnitudes of the determined action potentials were highest for pads of 25 µm in diameter and did not differ when the inter-pad distances were 100 or 170 µm. Using 25-µm diameter circular oxygen electrodes, the signal currents in the cell-culture media were found to range from approximately −0.08 nA (0% O2) to −2.35 nA (21% O2). It was observed that 60-nm thick silicon nitride-sensor layers were stable potentiometric pH sensors under cell-culture conditions for periods of days. Their sensitivity between pH 5 and 9 was as high as 45 mV per pH step. We concluded that sensorized GC3s are potential animal replacement systems for purposes such as toxicity pre-screening. For example, the effect of mefloquine, a medication used to treat malaria, on the electrical activity of neuronal cells was determined in this study using a GC3 system.
- Open Access
- 30 July 2015
- Published by MDPI AG in Biosensors
- Vol. 5 (3) , 513-536
Design and Characterization of a Sensorized Microfluidic Cell-Culture System with Electro-Thermal Micro-Pumps and Sensors for Cell Adhesion, Oxygen, and pH on a Glass Chip
We combined a multi-sensor glass-chip with a microfluidic channel grid for the characterization of cellular behavior. The grid was imprinted in poly-dimethyl-siloxane. Mouse-embryonal/fetal calvaria fibroblasts (MC3T3-E1) were used as a model system. Thin-film platinum (Pt) sensors for respiration (amperometric oxygen electrode), acidification (potentiometric pH electrodes) and cell adhesion (interdigitated-electrodes structures, IDES) allowed us to monitor cell-physiological parameters as well as the cell-spreading behavior. Two on-chip electro-thermal micro-pumps (ETμPs) permitted the induction of medium flow in the system, e.g., for medium mixing and drug delivery. The glass-wafer technology ensured the microscopic observability of the on-chip cell culture. Connecting Pt structures were passivated by a 1.2 μm layer of silicon nitride (Si3N4). Thin Si3N4 layers (20 nm or 60 nm) were used as the sensitive material of the pH electrodes. These electrodes showed a linear behavior in the pH range from 4 to 9, with a sensitivity of up to 39 mV per pH step. The oxygen sensors were circular Pt electrodes with a sensor area of 78.5 μm2. Their sensitivity was 100 pA per 1% oxygen increase in the range from 0% to 21% oxygen (air saturated). Two different IDES geometries with 30- and 50-μm finger spacings showed comparable sensitivities in detecting the proliferation rate of MC3T3 cells. These cells were cultured for 11 days in vitro to test the biocompatibility, microfluidics and electric sensors of our system under standard laboratory conditions.
- 30 July 2015
- Published by MDPI AG in Biosensors
- Vol. 5 (3) , 513-536
Open AccessDesign and Characterization of a Sensorized Microfluidic Cell-Culture System with Electro-Thermal Micro-Pumps and Sensors for Cell Adhesion, Oxygen, and pH on a Glass Chip
We combined a multi-sensor glass-chip with a microfluidic channel grid for the characterization of cellular behavior. The grid was imprinted in poly-dimethyl-siloxane. Mouse-embryonal/fetal calvaria fibroblasts (MC3T3-E1) were used as a model system. Thin-film platinum (Pt) sensors for respiration (amperometric oxygen electrode), acidification (potentiometric pH electrodes) and cell adhesion (interdigitated-electrodes structures, IDES) allowed us to monitor cell-physiological parameters as well as the cell-spreading behavior. Two on-chip electro-thermal micro-pumps (ETμPs) permitted the induction of medium flow in the system, e.g., for medium mixing and drug delivery. The glass-wafer technology ensured the microscopic observability of the on-chip cell culture. Connecting Pt structures were passivated by a 1.2 μm layer of silicon nitride (Si3N4). Thin Si3N4 layers (20 nm or 60 nm) were used as the sensitive material of the pH electrodes. These electrodes showed a linear behavior in the pH range from 4 to 9, with a sensitivity of up to 39 mV per pH step. The oxygen sensors were circular Pt electrodes with a sensor area of 78.5 μm2. Their sensitivity was 100 pA per 1% oxygen increase in the range from 0% to 21% oxygen (air saturated). Two different IDES geometries with 30- and 50-μm finger spacings showed comparable sensitivities in detecting the proliferation rate of MC3T3 cells. These cells were cultured for 11 days in vitro to test the biocompatibility, microfluidics and electric sensors of our system under standard laboratory conditions.
- Open Access
- 23 March 2015
- Published by MDPI AG in Micromachines
- Vol. 6 (3) , 364-374
Fast Prototyping of Sensorized Cell Culture Chips and Microfluidic Systems with Ultrashort Laser Pulses
We developed a confined microfluidic cell culture system with a bottom plate made of a microscopic slide with planar platinum sensors for the measurement of acidification, oxygen consumption, and cell adhesion. The slides were commercial slides with indium tin oxide (ITO) plating or were prepared from platinum sputtering (100 nm) onto a 10-nm titanium adhesion layer. Direct processing of the sensor structures (approximately three minutes per chip) by an ultrashort pulse laser facilitated the production of the prototypes. pH-sensitive areas were produced by the sputtering of 60-nm Si3N4 through a simple mask made from a circuit board material. The system body and polydimethylsiloxane (PDMS) molding forms for the microfluidic structures were manufactured by micromilling using a printed circuit board (PCB) milling machine for circuit boards. The microfluidic structure was finally imprinted in PDMS. Our approach avoided the use of photolithographic techniques and enabled fast and cost-efficient prototyping of the systems. Alternatively, the direct production of metallic, ceramic or polymeric molding tools was tested. The use of ultrashort pulse lasers improved the precision of the structures and avoided any contact of the final structures with toxic chemicals and possible adverse effects for the cell culture in lab-on-a-chip systems.
- 23 March 2015
- Published by MDPI AG in Micromachines
- Vol. 6 (3) , 364-374
Open AccessFast Prototyping of Sensorized Cell Culture Chips and Microfluidic Systems with Ultrashort Laser Pulses
We developed a confined microfluidic cell culture system with a bottom plate made of a microscopic slide with planar platinum sensors for the measurement of acidification, oxygen consumption, and cell adhesion. The slides were commercial slides with indium tin oxide (ITO) plating or were prepared from platinum sputtering (100 nm) onto a 10-nm titanium adhesion layer. Direct processing of the sensor structures (approximately three minutes per chip) by an ultrashort pulse laser facilitated the production of the prototypes. pH-sensitive areas were produced by the sputtering of 60-nm Si3N4 through a simple mask made from a circuit board material. The system body and polydimethylsiloxane (PDMS) molding forms for the microfluidic structures were manufactured by micromilling using a printed circuit board (PCB) milling machine for circuit boards. The microfluidic structure was finally imprinted in PDMS. Our approach avoided the use of photolithographic techniques and enabled fast and cost-efficient prototyping of the systems. Alternatively, the direct production of metallic, ceramic or polymeric molding tools was tested. The use of ultrashort pulse lasers improved the precision of the structures and avoided any contact of the final structures with toxic chemicals and possible adverse effects for the cell culture in lab-on-a-chip systems.
- 1 January 2012
- Published by Elsevier in Biophysical Journal
- Vol. 102 (3) , 583a-583A
Poregenic - Patch on Chip System for Adherent Cellular Networks
- 1 January 2012
- Published by Elsevier in Biophysical Journal
- Vol. 102 (3) , 583a-583A
Poregenic - Patch on Chip System for Adherent Cellular Networks
- Open Access
FIB Preparation and SEM Investigations for Three‐Dimensional Analysis of Cell Cultures on Microneedle Arrays
Summary: We report the investigation of the interfaces between microneedle arrays and cell cultures in patch‐on‐chip systems by using Focused Ion Beam (FIB) preparation and Scanning Electron Microscopy (SEM). First, FIB preparations of micro chips are made to determine the size and shape of the designed microneedles. In this essay, we investigate the cell‐substrate interaction, especially the cell adhesion, and the microneedle's potential cell penetration. For this purpose, cross‐sectional preparation of these hard/soft hybrid structures is performed by the FIB technology. By applying the FIB technology followed by high‐resolution imaging with SEM, new insights into the cell‐substrate interface can be received. One can clearly distinguish between cells that are only in contact with microneedles and cells that are penetrated by microneedles. A stack of slice images is collected by the application of the slice‐and‐view setup during FIB preparation and is used for threedimensional reconstruction of cells and micro‐needles. SCANNING 34: 221‐229, 2012.
Open AccessFIB Preparation and SEM Investigations for Three‐Dimensional Analysis of Cell Cultures on Microneedle Arrays
Summary: We report the investigation of the interfaces between microneedle arrays and cell cultures in patch‐on‐chip systems by using Focused Ion Beam (FIB) preparation and Scanning Electron Microscopy (SEM). First, FIB preparations of micro chips are made to determine the size and shape of the designed microneedles. In this essay, we investigate the cell‐substrate interaction, especially the cell adhesion, and the microneedle's potential cell penetration. For this purpose, cross‐sectional preparation of these hard/soft hybrid structures is performed by the FIB technology. By applying the FIB technology followed by high‐resolution imaging with SEM, new insights into the cell‐substrate interface can be received. One can clearly distinguish between cells that are only in contact with microneedles and cells that are penetrated by microneedles. A stack of slice images is collected by the application of the slice‐and‐view setup during FIB preparation and is used for threedimensional reconstruction of cells and micro‐needles. SCANNING 34: 221‐229, 2012.
- 1 December 2010
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 26 (4) , 1731-1735
Recording electric potentials from single adherent cells with 3D microelectrode arrays after local electroporation
- 1 December 2010
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 26 (4) , 1731-1735
Recording electric potentials from single adherent cells with 3D microelectrode arrays after local electroporation
- 31 March 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (12) , 1579-1586
Modular glass chip system measuring the electric activity and adhesion of neuronal cells—application and drug testing with sodium valproic acid
We developed a modular neurochip system by combining a small (16 × 16 mm2) glass neurochip (GNC) with a homemade head stage and commercial data acquisition hardware and software. The system is designed for the detection of the electric activity of cultivated nerve or muscle cells by a 52-microelectrode array (MEA). In parallel, cell adhesion can be registered from the electric impedance of an interdigitated electrode structure (IDES). The GNC was tested with various cell lines and primary cells. It is fully autoclavable and re-useable. Murine embryonic primary cells were used as a model system to correlate the electric activity and adhesion of neuronal networks in a drug test with sodium valproic acid. The test showed the advantage of the parallel IDES and MEA measurements, i.e. the parallel detection of cytotoxic and neurotoxic effects. Toxic exposure of the cells during neuronal network formation allows for the characterization of developmental neurotoxic effects even at drug concentrations below the EC50-value for acute neurotoxic effects. At high drug concentrations, the degree of cytotoxic damage can still be assessed from the IDES data in the event that no electric activity develops. The GNC provides optimal cell culture conditions for up to months in combination with full microscopic observability. The 4″ glass wafer technology allows for a high precision of the GNC structures and an economic production of our new system that can be applied in general and developmental toxicity tests as well as in the search for neuro-active compounds.
- 31 March 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (12) , 1579-1586
Modular glass chip system measuring the electric activity and adhesion of neuronal cells—application and drug testing with sodium valproic acid
We developed a modular neurochip system by combining a small (16 × 16 mm2) glass neurochip (GNC) with a homemade head stage and commercial data acquisition hardware and software. The system is designed for the detection of the electric activity of cultivated nerve or muscle cells by a 52-microelectrode array (MEA). In parallel, cell adhesion can be registered from the electric impedance of an interdigitated electrode structure (IDES). The GNC was tested with various cell lines and primary cells. It is fully autoclavable and re-useable. Murine embryonic primary cells were used as a model system to correlate the electric activity and adhesion of neuronal networks in a drug test with sodium valproic acid. The test showed the advantage of the parallel IDES and MEA measurements, i.e. the parallel detection of cytotoxic and neurotoxic effects. Toxic exposure of the cells during neuronal network formation allows for the characterization of developmental neurotoxic effects even at drug concentrations below the EC50-value for acute neurotoxic effects. At high drug concentrations, the degree of cytotoxic damage can still be assessed from the IDES data in the event that no electric activity develops. The GNC provides optimal cell culture conditions for up to months in combination with full microscopic observability. The 4″ glass wafer technology allows for a high precision of the GNC structures and an economic production of our new system that can be applied in general and developmental toxicity tests as well as in the search for neuro-active compounds.