Swetadri Vasan Setlur Nagesh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Swetadri Vasan Setlur Nagesh has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Ciprian Nicolae Ionita
Department of Biomedical Engineering University at Buffalo Buffalo USA
9 shared publications - Daniel R. Bednarek
Canon Stroke and Vascular Research Ctr., Univ. at Buffalo (United States)
6 shared publications - Stephen Rudin
Canon Stroke and Vascular Research Ctr., Univ. at Buffalo (United States)
6 shared publications S. Rudin
Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY
5 shared publications- Adnan H. Siddiqui
Department of Neurosurgery, State University of New York at Buffalo, Buffalo, New York, USA
4 shared publications D. R. Bednarek
Toshiba Stroke and Vascular Research Ctr. (United States)
4 shared publications
Latest Publications
- 26 November 2025
- Published by SAGE Publications in Interventional Neuroradiology
Correction of foreshortening and tube potential bias for improved quantitative angiographic assessment of intracranial aneurysms
Background: Quantitative angiography (QA) can extract hemodynamic information during neurointerventional procedures by leveraging contrast flow biomarkers. However, clinical adoption of two-dimensional (2D) QA remains limited compared with three-dimensional (3D) methods such as CT perfusion due to view-dependent biases when projecting 3D flow onto 2D images. Variations in tube potential (kVp) further modulate iodine attenuation, introducing intensity inconsistencies that confound QA measurements. This study evaluates a path-length correction (PLC) method designed to reduce orientation- and acquisition-related biases in 2D digital subtraction angiography (DSA). Materials and methods: Three cerebrovascular cases containing rotational and 2D DSAs were retrospectively analyzed. 3D volumes were reconstructed using cone-beam algorithms, and synthesized projections were spatially aligned with 2D DSA images using affine and non-linear transformations. Frame intensities were normalized for kVp using an iodine mass attenuation lookup. Path-length maps derived from aligned 3D volumes were then used to normalize DSA intensities, generating PLC images. QA parameters—peak height and area under the curve—were computed from pixel-wise time-density curves (TDCs) at matched regions of interest within aneurysm and parent vessels. PLC performance was evaluated by comparing root mean squared errors (RMSEs) between frontal and lateral TDCs and discrepancies in QA parameters before and after correction. Results: Across three cases, PLC improved cross-view consistency by reducing TDC RMSE from 0.23 ± 0.04 to 0.14 ± 0.04, peak height RMSE from of 0.42 ± 0.16 to 0.15 ± 0.11, and area under the curve RMSE from 0.43 ± 0.13 to 0.14 ± 0.13. Conclusions: The PLC method reduces foreshortening bias in 2D DSA and improves consistency of QA metrics, enhancing reliability in cerebrovascular assessment and treatment evaluation using clinical DSA.
- 26 November 2025
- Published by SAGE Publications in Interventional Neuroradiology
Correction of foreshortening and tube potential bias for improved quantitative angiographic assessment of intracranial aneurysms
Background: Quantitative angiography (QA) can extract hemodynamic information during neurointerventional procedures by leveraging contrast flow biomarkers. However, clinical adoption of two-dimensional (2D) QA remains limited compared with three-dimensional (3D) methods such as CT perfusion due to view-dependent biases when projecting 3D flow onto 2D images. Variations in tube potential (kVp) further modulate iodine attenuation, introducing intensity inconsistencies that confound QA measurements. This study evaluates a path-length correction (PLC) method designed to reduce orientation- and acquisition-related biases in 2D digital subtraction angiography (DSA). Materials and methods: Three cerebrovascular cases containing rotational and 2D DSAs were retrospectively analyzed. 3D volumes were reconstructed using cone-beam algorithms, and synthesized projections were spatially aligned with 2D DSA images using affine and non-linear transformations. Frame intensities were normalized for kVp using an iodine mass attenuation lookup. Path-length maps derived from aligned 3D volumes were then used to normalize DSA intensities, generating PLC images. QA parameters—peak height and area under the curve—were computed from pixel-wise time-density curves (TDCs) at matched regions of interest within aneurysm and parent vessels. PLC performance was evaluated by comparing root mean squared errors (RMSEs) between frontal and lateral TDCs and discrepancies in QA parameters before and after correction. Results: Across three cases, PLC improved cross-view consistency by reducing TDC RMSE from 0.23 ± 0.04 to 0.14 ± 0.04, peak height RMSE from of 0.42 ± 0.16 to 0.15 ± 0.11, and area under the curve RMSE from 0.43 ± 0.13 to 0.14 ± 0.13. Conclusions: The PLC method reduces foreshortening bias in 2D DSA and improves consistency of QA metrics, enhancing reliability in cerebrovascular assessment and treatment evaluation using clinical DSA.
- 1 May 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (03) , 033502-14
Angiographic velocimetry analysis using contrast dilution gradient method with a 1000 frames per second photon-counting detector
PurposeContrast dilution gradient (CDG) analysis is a quantitative method allowing blood velocity estimation using angiographic acquisitions. Currently, CDG is restricted to peripheral vasculature due to the suboptimal temporal resolution of current imaging systems. We investigate extension of CDG methods to the flow conditions of proximal vasculature using 1000 frames per second (fps) high-speed angiographic (HSA) imaging.ApproachWe performed in-vitro HSA acquisitions using the XC-Actaeon detector and 3D-printed patient-specific phantoms. The CDG approach was used for blood velocity estimation expressed as the ratio of temporal and spatial contrast gradients. The gradients were extracted from 2D contrast intensity maps synthesized by plotting intensity profiles along the arterial centerline at each frame. In-vitro results obtained at various frame rates via temporal binning of 1000 fps data were retrospectively compared to computational fluid dynamics (CFD) velocimetry. Full-vessel velocity distributions were estimated at 1000 fps via parallel line expansion of the arterial centerline analysis.ResultsUsing HSA, the CDG method displayed agreement with CFD at or above 250 fps [mean-absolute error (MAE): 2.6 ± 6.3 cm / s, p = 0.05]. Relative velocity distributions correlated well with CFD at 1000 fps with universal underapproximation due to effects of pulsatile contrast injection (MAE: 4.3 cm/s).ConclusionsUsing 1000 fps HSA, CDG-based extraction of velocities across large arteries is possible. The method is sensitive to noise; however, image processing techniques and a contrast injection, which adequately fills the vessel assist algorithm accuracy. The CDG method provides high resolution quantitative information for rapidly transient flow patterns observed in arterial circulation.
- 1 May 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (03) , 033502-14
Angiographic velocimetry analysis using contrast dilution gradient method with a 1000 frames per second photon-counting detector
PurposeContrast dilution gradient (CDG) analysis is a quantitative method allowing blood velocity estimation using angiographic acquisitions. Currently, CDG is restricted to peripheral vasculature due to the suboptimal temporal resolution of current imaging systems. We investigate extension of CDG methods to the flow conditions of proximal vasculature using 1000 frames per second (fps) high-speed angiographic (HSA) imaging.ApproachWe performed in-vitro HSA acquisitions using the XC-Actaeon detector and 3D-printed patient-specific phantoms. The CDG approach was used for blood velocity estimation expressed as the ratio of temporal and spatial contrast gradients. The gradients were extracted from 2D contrast intensity maps synthesized by plotting intensity profiles along the arterial centerline at each frame. In-vitro results obtained at various frame rates via temporal binning of 1000 fps data were retrospectively compared to computational fluid dynamics (CFD) velocimetry. Full-vessel velocity distributions were estimated at 1000 fps via parallel line expansion of the arterial centerline analysis.ResultsUsing HSA, the CDG method displayed agreement with CFD at or above 250 fps [mean-absolute error (MAE): 2.6 ± 6.3 cm / s, p = 0.05]. Relative velocity distributions correlated well with CFD at 1000 fps with universal underapproximation due to effects of pulsatile contrast injection (MAE: 4.3 cm/s).ConclusionsUsing 1000 fps HSA, CDG-based extraction of velocities across large arteries is possible. The method is sensitive to noise; however, image processing techniques and a contrast injection, which adequately fills the vessel assist algorithm accuracy. The CDG method provides high resolution quantitative information for rapidly transient flow patterns observed in arterial circulation.
- 4 April 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12031, 998-1008
Simultaneous biplane high speed 1000 fps x-ray angiography (HSAngio)
High-speed 1000-fps x-ray Angiography (HSAngio) images can be used to visualize blood-flow patterns and derive flow velocities during neurointerventional procedures. In this work, we present for the very first-time, orthogonal views of contrast injection in an aneurysm model acquired simultaneously using biplane HSAngio imaging. 3-D printed in-vitro models A and B of two different internal carotid-artery aneurysms were connected to a flow loop (circulation fluid: 60% water, 40% glycerol solution, circulation flow rate: 8 L/s). An automatic programmable injector (KD Scientific Legato 110) injected iodine contrast agent at a rate of 88 mL/min for a duration of 3 sec. With an RQA5 spectrum, 1000 fps HSAngio sequences of the contrast injection were acquired simultaneously on the frontal plane using the Actaeon detector (Direct Conversion, Stockholm) and on the lateral plane using the Aries (Direct Conversion, Stockholm) detector. The start of contrast injection and simultaneous biplane x-ray exposures and detector image acquisitions were manually synchronized to capture the initial inflow of contrast into the aneurysm region. For model A the frontal plane images gave a better visualization of the flow streamlines in the parent artery in the inflow (average velocity 28 cm/s) and outflow (average velocity 24 cm/s) region of the aneurysm. The vortices within the aneurysm region especially within the aneurysm dome were better visualized in the lateral plane images (average velocity 27 cm/s). Biplane HSAngio imaging techniques can give more accurate representations of 3-D blood flow within the complex vascular pathology of the human brain, compared to single-plane imaging.
- 4 April 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12031, 998-1008
Simultaneous biplane high speed 1000 fps x-ray angiography (HSAngio)
High-speed 1000-fps x-ray Angiography (HSAngio) images can be used to visualize blood-flow patterns and derive flow velocities during neurointerventional procedures. In this work, we present for the very first-time, orthogonal views of contrast injection in an aneurysm model acquired simultaneously using biplane HSAngio imaging. 3-D printed in-vitro models A and B of two different internal carotid-artery aneurysms were connected to a flow loop (circulation fluid: 60% water, 40% glycerol solution, circulation flow rate: 8 L/s). An automatic programmable injector (KD Scientific Legato 110) injected iodine contrast agent at a rate of 88 mL/min for a duration of 3 sec. With an RQA5 spectrum, 1000 fps HSAngio sequences of the contrast injection were acquired simultaneously on the frontal plane using the Actaeon detector (Direct Conversion, Stockholm) and on the lateral plane using the Aries (Direct Conversion, Stockholm) detector. The start of contrast injection and simultaneous biplane x-ray exposures and detector image acquisitions were manually synchronized to capture the initial inflow of contrast into the aneurysm region. For model A the frontal plane images gave a better visualization of the flow streamlines in the parent artery in the inflow (average velocity 28 cm/s) and outflow (average velocity 24 cm/s) region of the aneurysm. The vortices within the aneurysm region especially within the aneurysm dome were better visualized in the lateral plane images (average velocity 27 cm/s). Biplane HSAngio imaging techniques can give more accurate representations of 3-D blood flow within the complex vascular pathology of the human brain, compared to single-plane imaging.
- Open Access
- 15 February 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11595, 1159538-170
Investigation of the need for an x-ray scatter-reduction grid during neurointerventional procedures
X-ray guided neurointerventions are catheter-based treatments for cerebrovascular diseases such as strokes and aneurysms. During such procedures visualization of treatment devices is the primary imaging task. In this work we investigate the necessity of x-ray scatter-reduction grids in performing those tasks. Various endovascular treatment devices such as stents, coils and catheters along with a low contrast blood vessel phantom were placed on a head-equivalent phantom. Images of the objects were acquired with and without a grid (15:1 grid ratio, 80 lines/cm and Al interspace). The x-ray field was set to the full 8 x 8 inch FOV to allow for realistic scatter generation. The detector was positioned close to the phantom to investigate maximal scatter conditions. Contrast and Contrast to Noise (CNR) ratios of the catheter tip and the blood vessel phantom were measured and compared for images obtained with and without the grid. The x-ray technique parameters were kept constant for all acquisitions. For the catheter tip there was a 43% reduction in contrast with the removal of the grid due to increased scatter reaching the detector. However, due to increased primary there was a 18% increase in CNR. For the blood vessel phantom, there was a 33% reduction in contrast, whereas a 17% increase in CNR. All the devices and the blood vessels in the phantom were still visible even with the increased scatter without the grid. The results of the study indicate the use of grids during neurointervention procedures might not be necessary to perform the intervention.
- 15 February 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11595, 1159538-170
Open AccessInvestigation of the need for an x-ray scatter-reduction grid during neurointerventional procedures
X-ray guided neurointerventions are catheter-based treatments for cerebrovascular diseases such as strokes and aneurysms. During such procedures visualization of treatment devices is the primary imaging task. In this work we investigate the necessity of x-ray scatter-reduction grids in performing those tasks. Various endovascular treatment devices such as stents, coils and catheters along with a low contrast blood vessel phantom were placed on a head-equivalent phantom. Images of the objects were acquired with and without a grid (15:1 grid ratio, 80 lines/cm and Al interspace). The x-ray field was set to the full 8 x 8 inch FOV to allow for realistic scatter generation. The detector was positioned close to the phantom to investigate maximal scatter conditions. Contrast and Contrast to Noise (CNR) ratios of the catheter tip and the blood vessel phantom were measured and compared for images obtained with and without the grid. The x-ray technique parameters were kept constant for all acquisitions. For the catheter tip there was a 43% reduction in contrast with the removal of the grid due to increased scatter reaching the detector. However, due to increased primary there was a 18% increase in CNR. For the blood vessel phantom, there was a 33% reduction in contrast, whereas a 17% increase in CNR. All the devices and the blood vessels in the phantom were still visible even with the increased scatter without the grid. The results of the study indicate the use of grids during neurointervention procedures might not be necessary to perform the intervention.
- 6 June 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (7) , 1197-1200
Flow-Pattern Details in an Aneurysm Model Using High-Speed 1000-Frames-per-Second Angiography
SUMMARY: Traditional digital subtraction angiography provides rather limited evaluation of contrast flow dynamics when studying and treating intracranial brain aneurysms. A 1000-frames-per-second photon-counting x-ray detector was used to image detailed iodine-contrast flow patterns in an internal carotid artery aneurysm of a 3D-printed vascular phantom. High-speed imaging revealed differences in vortex and inflow patterns with and without a Pipeline Embolization Device flow diverter in more detail and clarity than could be seen in standard pulsed angiography. Improved temporal imaging has the potential to impact the outcomes of endovascular interventions by allowing clinicians to better understand and act on flow dynamics in real-time.
- 6 June 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (7) , 1197-1200
Flow-Pattern Details in an Aneurysm Model Using High-Speed 1000-Frames-per-Second Angiography
SUMMARY: Traditional digital subtraction angiography provides rather limited evaluation of contrast flow dynamics when studying and treating intracranial brain aneurysms. A 1000-frames-per-second photon-counting x-ray detector was used to image detailed iodine-contrast flow patterns in an internal carotid artery aneurysm of a 3D-printed vascular phantom. High-speed imaging revealed differences in vortex and inflow patterns with and without a Pipeline Embolization Device flow diverter in more detail and clarity than could be seen in standard pulsed angiography. Improved temporal imaging has the potential to impact the outcomes of endovascular interventions by allowing clinicians to better understand and act on flow dynamics in real-time.
- Open Access
- 27 December 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (2) , 302-308
High-Definition Zoom Mode, a High-Resolution X-Ray Microscope for Neurointerventional Treatment Procedures: A Blinded-Rater Clinical-Utility Study
BACKGROUND AND PURPOSE: Quality of visualization of treatment devices during critical stages of endovascular interventions, can directly impact their safety and efficacy. Our aim was to compare the visualization of neurointerventional procedures and treatment devices using a 194-μm pixel flat panel detector mode and a 76-μm pixel complementary metal oxide semiconductor detector mode (high definition) of a new-generation x-ray detector system using a blinded-rater study. MATERIALS AND METHODS: Deployment of flow-diversion devices for the treatment of internal carotid artery aneurysms was performed under flat panel detector and high-definition-mode image guidance in a neurointerventional phantom simulating patient cranium and tissue attenuation, embedded with 3D-printed intracranial vascular models, each with an aneurysm in the ICA segment. Image-sequence pairs of device deployments for each detector mode, under similar exposure and FOV conditions, were evaluated by 2 blinded experienced neurointerventionalists who independently selected their preferred image on the basis of visualization of anatomic features, image noise, and treatment device. They rated their selection as either similar, better, much better, or substantially better than the other choice. Inter- and intrarater agreement was calculated and categorized as poor, moderate, and good. RESULTS: Both raters demonstrating good inter- and intrarater agreement selected high-definition-mode images with a frequency of at least 95% each and, on average, rated the high-definition images as much better than flat panel detector images with a frequency of 73% from a total of 60 image pairs. CONCLUSIONS: Due to their higher resolution, high-definition-mode images are sharper and visually preferred compared with the flat panel detector images. The improved imaging provided by the high-definition mode can potentially provide an advantage during neurointerventional procedures.
- 27 December 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (2) , 302-308
Open AccessHigh-Definition Zoom Mode, a High-Resolution X-Ray Microscope for Neurointerventional Treatment Procedures: A Blinded-Rater Clinical-Utility Study
BACKGROUND AND PURPOSE: Quality of visualization of treatment devices during critical stages of endovascular interventions, can directly impact their safety and efficacy. Our aim was to compare the visualization of neurointerventional procedures and treatment devices using a 194-μm pixel flat panel detector mode and a 76-μm pixel complementary metal oxide semiconductor detector mode (high definition) of a new-generation x-ray detector system using a blinded-rater study. MATERIALS AND METHODS: Deployment of flow-diversion devices for the treatment of internal carotid artery aneurysms was performed under flat panel detector and high-definition-mode image guidance in a neurointerventional phantom simulating patient cranium and tissue attenuation, embedded with 3D-printed intracranial vascular models, each with an aneurysm in the ICA segment. Image-sequence pairs of device deployments for each detector mode, under similar exposure and FOV conditions, were evaluated by 2 blinded experienced neurointerventionalists who independently selected their preferred image on the basis of visualization of anatomic features, image noise, and treatment device. They rated their selection as either similar, better, much better, or substantially better than the other choice. Inter- and intrarater agreement was calculated and categorized as poor, moderate, and good. RESULTS: Both raters demonstrating good inter- and intrarater agreement selected high-definition-mode images with a frequency of at least 95% each and, on average, rated the high-definition images as much better than flat panel detector images with a frequency of 73% from a total of 60 image pairs. CONCLUSIONS: Due to their higher resolution, high-definition-mode images are sharper and visually preferred compared with the flat panel detector images. The improved imaging provided by the high-definition mode can potentially provide an advantage during neurointerventional procedures.
- Open Access
- 12 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10578, 105780N-22
A simulation platform using 3D printed neurovascular phantoms for clinical utility evaluation of new imaging technologies
Modern 3D printing technology allows rapid prototyping of vascular phantoms based on an actual human patient with a high degree of precision. Using this technology, we present a platform to accurately simulate clinical views of neuro-endovascular interventions and devices. The neuro-endovascular interventional phantom has a 3D printed cerebrovasculature model derived from a patient CT angiogram and embedded inside a human skull providing bone attenuation. Acrylic layers were placed underneath and on top of the skull, simulating entrance and exit tissue attenuation and also simulating forward scatter. The 3D model was connected to a pulsatile flow loop for simulating interventions using clinical devices such as catheters and stents. To validate the x-ray attenuation and establish clinical accuracy, the automatic exposure selection by a clinical c-arm system for the phantom was compared with that for a commercial anthropomorphic head phantom (SK-150, Phantom Labs). The percentage difference between automatic exposure selection for the neuro-intervention phantom and the SK-150 phantom was under 10%. By changing 3D printed models, various patient diseased anatomies can be simulated accurately with the necessary x-ray attenuation. Using this platform various interventional procedures were performed using new imaging technologies such as a high-resolution x-ray fluoroscope and a dose-reduced region-of-interest attenuator and differential temporally filtered display for enhanced interventional imaging. Simulated clinical views from such phantom-based procedures were used to evaluate the potential clinical performance of such new technologies.
- 12 March 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10578, 105780N-22
Open AccessA simulation platform using 3D printed neurovascular phantoms for clinical utility evaluation of new imaging technologies
Modern 3D printing technology allows rapid prototyping of vascular phantoms based on an actual human patient with a high degree of precision. Using this technology, we present a platform to accurately simulate clinical views of neuro-endovascular interventions and devices. The neuro-endovascular interventional phantom has a 3D printed cerebrovasculature model derived from a patient CT angiogram and embedded inside a human skull providing bone attenuation. Acrylic layers were placed underneath and on top of the skull, simulating entrance and exit tissue attenuation and also simulating forward scatter. The 3D model was connected to a pulsatile flow loop for simulating interventions using clinical devices such as catheters and stents. To validate the x-ray attenuation and establish clinical accuracy, the automatic exposure selection by a clinical c-arm system for the phantom was compared with that for a commercial anthropomorphic head phantom (SK-150, Phantom Labs). The percentage difference between automatic exposure selection for the neuro-intervention phantom and the SK-150 phantom was under 10%. By changing 3D printed models, various patient diseased anatomies can be simulated accurately with the necessary x-ray attenuation. Using this platform various interventional procedures were performed using new imaging technologies such as a high-resolution x-ray fluoroscope and a dose-reduced region-of-interest attenuator and differential temporally filtered display for enhanced interventional imaging. Simulated clinical views from such phantom-based procedures were used to evaluate the potential clinical performance of such new technologies.
- Open Access
- 15 February 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (4) , 734-741
A Patient Dose-Reduction Technique for Neuroendovascular Image-Guided Interventions: Image-Quality Comparison Study
BACKGROUND AND PURPOSE: The ROI–dose-reduced intervention technique represents an extension of ROI fluoroscopy combining x-ray entrance skin dose reduction with spatially different recursive temporal filtering to reduce excessive image noise in the dose-reduced periphery in real-time. The aim of our study was to compare the image quality of simulated neurointerventions with regular and reduced radiation doses using a standard flat panel detector system. MATERIALS AND METHODS: Ten 3D-printed intracranial aneurysm models were generated on the basis of a single patient vasculature derived from intracranial DSA and CTA. The incident dose to each model was reduced using a 0.7-mm-thick copper attenuator with a circular ROI hole (10-mm diameter) in the middle mounted inside the Infinix C-arm. Each model was treated twice with a primary coiling intervention using ROI-dose-reduced intervention and regular-dose intervention protocols. Eighty images acquired at various intervention stages were shown twice to 2 neurointerventionalists who independently scored imaging qualities (visibility of aneurysm-parent vessel morphology, associated vessels, and/or devices used). Dose-reduction measurements were performed using an ionization chamber. RESULTS: A total integral dose reduction of 62% per frame was achieved. The mean scores for regular-dose intervention and ROI dose-reduced intervention images did not differ significantly, suggesting similar image quality. Overall intrarater agreement for all scored criteria was substantial (Kendall τ = 0.62887; P < .001). Overall interrater agreement for all criteria was fair (κ = 0.2816; 95% CI, 0.2060–0.3571). CONCLUSIONS: Substantial dose reduction (62%) with a live peripheral image was achieved without compromising feature visibility during neuroendovascular interventions.
- 15 February 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (4) , 734-741
Open AccessA Patient Dose-Reduction Technique for Neuroendovascular Image-Guided Interventions: Image-Quality Comparison Study
BACKGROUND AND PURPOSE: The ROI–dose-reduced intervention technique represents an extension of ROI fluoroscopy combining x-ray entrance skin dose reduction with spatially different recursive temporal filtering to reduce excessive image noise in the dose-reduced periphery in real-time. The aim of our study was to compare the image quality of simulated neurointerventions with regular and reduced radiation doses using a standard flat panel detector system. MATERIALS AND METHODS: Ten 3D-printed intracranial aneurysm models were generated on the basis of a single patient vasculature derived from intracranial DSA and CTA. The incident dose to each model was reduced using a 0.7-mm-thick copper attenuator with a circular ROI hole (10-mm diameter) in the middle mounted inside the Infinix C-arm. Each model was treated twice with a primary coiling intervention using ROI-dose-reduced intervention and regular-dose intervention protocols. Eighty images acquired at various intervention stages were shown twice to 2 neurointerventionalists who independently scored imaging qualities (visibility of aneurysm-parent vessel morphology, associated vessels, and/or devices used). Dose-reduction measurements were performed using an ionization chamber. RESULTS: A total integral dose reduction of 62% per frame was achieved. The mean scores for regular-dose intervention and ROI dose-reduced intervention images did not differ significantly, suggesting similar image quality. Overall intrarater agreement for all scored criteria was substantial (Kendall τ = 0.62887; P < .001). Overall interrater agreement for all criteria was fair (κ = 0.2816; 95% CI, 0.2060–0.3571). CONCLUSIONS: Substantial dose reduction (62%) with a live peripheral image was achieved without compromising feature visibility during neuroendovascular interventions.
- 31 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9783, 97833R
Focal spot deblurring for high resolution direct conversion x-ray detectors
Small pixel high resolution direct x-ray detectors have the advantage of higher spatial sampling and decreased blurring characteristic. The limiting factors for such systems becomes the degradation due to the focal spot size. One solution is a smaller focal spot; however, this can limit the output of the x-ray tube. Here a software solution of deconvolving with an estimated focal spot blur is presented. To simulate images from a direct detector affected with focal-spot blur, first a set of high-resolution stent images (FRED from Microvention, Inc., Tustin, CA) were acquired using a 75μm pixel size Dexela-Perkin-Elmer detector and frame averaged to reduce quantum noise. Then the averaged image was blurred with a known Gaussian blur. To add noise to the blurred image a flat-field image was multiplied with the blurred image. Both the ideal and the noisy-blurred images were then deconvolved with the known Gaussian function using either threshold-based inverse filtering or Weiner deconvolution. The blur in the ideal image was removed and the details were recovered successfully. However, the inverse filtering deconvolution process is extremely susceptible to noise. The Weiner deconvolution process was able to recover more of the details of the stent from the noisy-blurred image, but for noisier images, stent details are still lost in the recovery process.
- 31 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9783, 97833R
Focal spot deblurring for high resolution direct conversion x-ray detectors
Small pixel high resolution direct x-ray detectors have the advantage of higher spatial sampling and decreased blurring characteristic. The limiting factors for such systems becomes the degradation due to the focal spot size. One solution is a smaller focal spot; however, this can limit the output of the x-ray tube. Here a software solution of deconvolving with an estimated focal spot blur is presented. To simulate images from a direct detector affected with focal-spot blur, first a set of high-resolution stent images (FRED from Microvention, Inc., Tustin, CA) were acquired using a 75μm pixel size Dexela-Perkin-Elmer detector and frame averaged to reduce quantum noise. Then the averaged image was blurred with a known Gaussian blur. To add noise to the blurred image a flat-field image was multiplied with the blurred image. Both the ideal and the noisy-blurred images were then deconvolved with the known Gaussian function using either threshold-based inverse filtering or Weiner deconvolution. The blur in the ideal image was removed and the details were recovered successfully. However, the inverse filtering deconvolution process is extremely susceptible to noise. The Weiner deconvolution process was able to recover more of the details of the stent from the noisy-blurred image, but for noisier images, stent details are still lost in the recovery process.
- 6 March 2013
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 8668, 86680J
Quantitative analysis of an enlarged area solid state x-ray image intensifier (SSXII) detector based on electron multiplying charge coupled device (EMCCD) technology
Present day treatment for neurovascular pathological conditions involves the use of devices with very small features such as stents, coils, and balloons; hence, these interventional procedures demand high resolution xray imaging under fluoroscopic conditions to provide the capability to guide the deployment of these fine endovascular devices. To address this issue, a high resolution x-ray detector based on EMCCD technology is being developed. The EMCCD field-of-view is enlarged using a fiber-optic taper so that the detector features an effective pixel size of 37 μm giving it a Nyquist frequency of 13.5 lp/mm, which is significantly higher than that of the state of the art Flat Panel Detectors (FPD). Quantitative analysis of the detector, including gain calibration, instrumentation noise equivalent exposure (INEE) and modulation transfer function (MTF) determination, are presented in this work. The gain of the detector is a function of the detector temperature; with the detector cooled to 50 C, the highest relative gain that could be achieved was calculated to be 116 times. At this gain setting, the lowest INEE was measured to be 0.6 μR/frame. The MTF, measured using the edge method, was over 2% up to 7 cycles/ mm. To evaluate the performance of the detector under clinical conditions, an aneurysm model was placed over an anthropomorphic head phantom and a coil was guided into the aneurysm under fluoroscopic guidance using the detector. Image sequences from the procedure are presented demonstrating the high resolution of this SSXII.
- 6 March 2013
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 8668, 86680J
Quantitative analysis of an enlarged area solid state x-ray image intensifier (SSXII) detector based on electron multiplying charge coupled device (EMCCD) technology
Present day treatment for neurovascular pathological conditions involves the use of devices with very small features such as stents, coils, and balloons; hence, these interventional procedures demand high resolution xray imaging under fluoroscopic conditions to provide the capability to guide the deployment of these fine endovascular devices. To address this issue, a high resolution x-ray detector based on EMCCD technology is being developed. The EMCCD field-of-view is enlarged using a fiber-optic taper so that the detector features an effective pixel size of 37 μm giving it a Nyquist frequency of 13.5 lp/mm, which is significantly higher than that of the state of the art Flat Panel Detectors (FPD). Quantitative analysis of the detector, including gain calibration, instrumentation noise equivalent exposure (INEE) and modulation transfer function (MTF) determination, are presented in this work. The gain of the detector is a function of the detector temperature; with the detector cooled to 50 C, the highest relative gain that could be achieved was calculated to be 116 times. At this gain setting, the lowest INEE was measured to be 0.6 μR/frame. The MTF, measured using the edge method, was over 2% up to 7 cycles/ mm. To evaluate the performance of the detector under clinical conditions, an aneurysm model was placed over an anthropomorphic head phantom and a coil was guided into the aneurysm under fluoroscopic guidance using the detector. Image sequences from the procedure are presented demonstrating the high resolution of this SSXII.