High-Definition Zoom Mode, a High-Resolution X-Ray Microscope for Neurointerventional Treatment Procedures: A Blinded-Rater Clinical-Utility Study
Open Access
- 27 December 2018
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (2) , 302-308
Abstract
BACKGROUND AND PURPOSE: Quality of visualization of treatment devices during critical stages of endovascular interventions, can directly impact their safety and efficacy. Our aim was to compare the visualization of neurointerventional procedures and treatment devices using a 194-μm pixel flat panel detector mode and a 76-μm pixel complementary metal oxide semiconductor detector mode (high definition) of a new-generation x-ray detector system using a blinded-rater study. MATERIALS AND METHODS: Deployment of flow-diversion devices for the treatment of internal carotid artery aneurysms was performed under flat panel detector and high-definition-mode image guidance in a neurointerventional phantom simulating patient cranium and tissue attenuation, embedded with 3D-printed intracranial vascular models, each with an aneurysm in the ICA segment. Image-sequence pairs of device deployments for each detector mode, under similar exposure and FOV conditions, were evaluated by 2 blinded experienced neurointerventionalists who independently selected their preferred image on the basis of visualization of anatomic features, image noise, and treatment device. They rated their selection as either similar, better, much better, or substantially better than the other choice. Inter- and intrarater agreement was calculated and categorized as poor, moderate, and good. RESULTS: Both raters demonstrating good inter- and intrarater agreement selected high-definition-mode images with a frequency of at least 95% each and, on average, rated the high-definition images as much better than flat panel detector images with a frequency of 73% from a total of 60 image pairs. CONCLUSIONS: Due to their higher resolution, high-definition-mode images are sharper and visually preferred compared with the flat panel detector images. The improved imaging provided by the high-definition mode can potentially provide an advantage during neurointerventional procedures.Keywords
Funding Information
- National Institutes of Health (R01EB2873)
- Canon Medical Systems Corporation
This publication has 20 references indexed in Scilit:
- The Pipeline embolization device for treatment of intracranial aneurysmsExpert Review of Medical Devices, 2013
- Variable Porosity of the Pipeline Embolization Device in Straight and Curved Vessels: A Guide for Optimal Deployment StrategyAmerican Journal of Neuroradiology, 2013
- Validity of wax and acrylic as soft-tissue simulation materials used inin vitroradiographic studiesDentomaxillofacial Radiology, 2012
- Endovascular coil embolization of a very small ruptured aneurysm using a novel microangiographic technique: technical noteJournal of NeuroInterventional Surgery, 2012
- Use of the Microangiographic Fluoroscope for Coiling of Intracranial AneurysmsNeurosurgery, 2011
- A theoretical and experimental evaluation of the microangiographic fluoroscope: A high‐resolution region‐of‐interest x‐ray imagerMedical Physics, 2011
- AAPM/RSNA Physics Tutorial for Residents: Physics of Flat-Panel Fluoroscopy SystemsRadioGraphics, 2011
- Operating microscopes: past, present, and futureNeurosurgical Focus, 2009
- Selenium-based digital radiography versus conventional film-screen radiography of the hands and feet: a subjective comparison.American Journal of Roentgenology, 1999
- Screen-film versus computed radiography imaging of the hand: a direct comparison.American Journal of Roentgenology, 1997