Tomer Noyhouzer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tomer Noyhouzer has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Mandler
Singapore‐HUJ Alliance for Research and Enterprise (SHARE) Smart Grippers for Soft Robotics (SGSR) Campus for Research Excellence and Technological Enterprise Singapore Singapore
5 shared publications - Janine Mauzeroll
McGill University
5 shared publications - Isabelle Beaulieu
Department of Chemistry, McGill University, Montréal, Canada
2 shared publications - Nicholas Austin Payne
Laboratory for Electrochemical Reactive Imaging and Detection of Biological Systems, McGill University, Montreal, QC H3A 0B8, Canada
2 shared publications Andy Vicente-Luis
Department of Chemistry, Université de Montréal, Montréal, QC H3T 1J4, Canada
1 shared publicationChloé L’hOmme
Laboratoire de Méthodologie et Synthèse de Produits Naturels, Université du Québec à Montréal , C.P. 8888, Succ. Centre-Ville, Montréal, H3C 3P8, Québec, Canada
1 shared publication
Latest Publications
- 28 January 2021
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 7 (3) , 622-629
Portable and sustainable activated carbon-based device for electro-assisted water purification
Schematic representation of a carbon-based portable electrochemical filtration device designed to remove toxic amounts of lead and arsenic found in drinking water.
- 28 January 2021
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 7 (3) , 622-629
Portable and sustainable activated carbon-based device for electro-assisted water purification
Schematic representation of a carbon-based portable electrochemical filtration device designed to remove toxic amounts of lead and arsenic found in drinking water.
- 26 February 2018
- Published by Springer Nature in Electrocatalysis
- Vol. 9 (4) , 531-538
Unfolding the Hidden Reactions in Galvanic Cells
- 26 February 2018
- Published by Springer Nature in Electrocatalysis
- Vol. 9 (4) , 531-538
Unfolding the Hidden Reactions in Galvanic Cells
- 13 January 2018
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165 (2) , H10-H15
The Best of Both Worlds: Combining Ultramicroelectrode and Flow Cell Technologies
A new type of an electrochemical flow cell designed for exchangeable ultramicroelectrodes (UMEs) is presented. The cell could be used with up to 8 different UMEs allowing one to use this cell for UME array measurements. The cell was characterized using both empirical data and finite element modeling. Au and Pt UMEs were used to detect catechol simultaneously, demonstrating the ability of this cell to be used as a sensory platform. The electroanalytical response of flow system was validated by direct measurements of H2O2 concentrations. Finally, stochastic nanoparticle measurements were successfully performed using the flow system, highlighting the future possibilities of this system for environmental monitoring.
- 13 January 2018
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165 (2) , H10-H15
The Best of Both Worlds: Combining Ultramicroelectrode and Flow Cell Technologies
A new type of an electrochemical flow cell designed for exchangeable ultramicroelectrodes (UMEs) is presented. The cell could be used with up to 8 different UMEs allowing one to use this cell for UME array measurements. The cell was characterized using both empirical data and finite element modeling. Au and Pt UMEs were used to detect catechol simultaneously, demonstrating the ability of this cell to be used as a sensory platform. The electroanalytical response of flow system was validated by direct measurements of H2O2 concentrations. Finally, stochastic nanoparticle measurements were successfully performed using the flow system, highlighting the future possibilities of this system for environmental monitoring.
- 28 April 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (10) , 5246-5253
Modular Flow-Through Platform for Spectroelectrochemical Analysis
A new type of flow platform for electrochemical and spectroelectrochemical measurements is presented. Finite element method simulations confirm that the hydrodynamic profile within the device is not turbulent and provides an analytical platform for the investigation of homogeneous kinetics, radical lifetimes, and reaction mechanisms. The modular “plug and play” configuration of the platform allows one to carry out electrochemistry and spectroscopy individually or simultaneously. Specific demonstrations of electroanalytical measurements using the flow system platform includes voltammetric analysis of organometallic compounds and quantitative analysis of ascorbic acid in commercial orange juice samples. Combined spectroelectrochemical demonstrations include electrochemical luminescence of ruthenium compounds and ligand exchange reactions of iron complexes using UV–vis spectroscopy.
- 28 April 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (10) , 5246-5253
Modular Flow-Through Platform for Spectroelectrochemical Analysis
A new type of flow platform for electrochemical and spectroelectrochemical measurements is presented. Finite element method simulations confirm that the hydrodynamic profile within the device is not turbulent and provides an analytical platform for the investigation of homogeneous kinetics, radical lifetimes, and reaction mechanisms. The modular “plug and play” configuration of the platform allows one to carry out electrochemistry and spectroscopy individually or simultaneously. Specific demonstrations of electroanalytical measurements using the flow system platform includes voltammetric analysis of organometallic compounds and quantitative analysis of ascorbic acid in commercial orange juice samples. Combined spectroelectrochemical demonstrations include electrochemical luminescence of ruthenium compounds and ligand exchange reactions of iron complexes using UV–vis spectroscopy.
- 21 April 2016
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 32 (17) , 4169-4178
Ferrocene-Modified Phospholipid: An Innovative Precursor for Redox-Triggered Drug Delivery Vesicles Selective to Cancer Cells
Controlled payload release is one of the key elements in the creation of a reliable drug delivery system. We report the discovery of a drug delivery vessel able to transport chemotherapeutic agents to target cancer cells and selectively trigger their release using the electrochemical activity of a ferrocene modified phospholipid. Supported by in vitro assays, the competitive advantages of this discovery are; i) the simple one step scalability of the synthetic process, ii) the stable encapsulation of toxic drugs (doxorubicin) during transport and iii) the selective redox triggering of the liposomes to harness their cytotoxic payload at the cancer site. Specifically the redox modified giant unilamellar vesicle and liposomes were characterized using advanced methods such as Scanning Electrochemical Microscopy (SECM), Transmission Electron Microscopy (TEM), Dynamic Light Scattering (DLS) and fluorescent imaging.
- 21 April 2016
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 32 (17) , 4169-4178
Ferrocene-Modified Phospholipid: An Innovative Precursor for Redox-Triggered Drug Delivery Vesicles Selective to Cancer Cells
Controlled payload release is one of the key elements in the creation of a reliable drug delivery system. We report the discovery of a drug delivery vessel able to transport chemotherapeutic agents to target cancer cells and selectively trigger their release using the electrochemical activity of a ferrocene modified phospholipid. Supported by in vitro assays, the competitive advantages of this discovery are; i) the simple one step scalability of the synthetic process, ii) the stable encapsulation of toxic drugs (doxorubicin) during transport and iii) the selective redox triggering of the liposomes to harness their cytotoxic payload at the cancer site. Specifically the redox modified giant unilamellar vesicle and liposomes were characterized using advanced methods such as Scanning Electrochemical Microscopy (SECM), Transmission Electron Microscopy (TEM), Dynamic Light Scattering (DLS) and fluorescent imaging.
- 19 July 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (17) , 8347-8353
Enhanced Potentiometry by Metallic Nanoparticles
Measuring the oxidation–reduction potential (Eh) requires an interface that is not selective toward specific species but exchanges electrons with all redox couples in the solution. Sluggish electron transfer (ET) kinetics with the species will not reflect the “true” Eh of the solution. Here, we present a novel approach by which adsorbed metal nanoparticles (NPs) are used for enhancing ET exchange rates between redox species and electrode surface and therefore affect significantly the measurement of the open circuit potential (OCP) and cyclic voltammetry (CV). The OCP and CV of various organic and inorganic species such as l-dopa, dopac, iron(II), and iodide are measured by bare stainless steel and by stainless steel modified by either Pt or Au NPs. We study the effect of the surface coverage of the stainless steel surface by NPs on the electrochemical response. Moreover, the stainless steel electrode was modified simultaneously by Au and Pt nanoparticles. This improved concurrently the stainless steel response (CV and potentiometry) toward two different species; l-dopa, which shows fast electron transfer on Pt, and catechol, which exhibits fast electron transfer on Au. We believe that this approach could be a first step toward developing a superior electrode for measuring the “true” Eh of complex aquatic systems.
- 19 July 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (17) , 8347-8353
Enhanced Potentiometry by Metallic Nanoparticles
Measuring the oxidation–reduction potential (Eh) requires an interface that is not selective toward specific species but exchanges electrons with all redox couples in the solution. Sluggish electron transfer (ET) kinetics with the species will not reflect the “true” Eh of the solution. Here, we present a novel approach by which adsorbed metal nanoparticles (NPs) are used for enhancing ET exchange rates between redox species and electrode surface and therefore affect significantly the measurement of the open circuit potential (OCP) and cyclic voltammetry (CV). The OCP and CV of various organic and inorganic species such as l-dopa, dopac, iron(II), and iodide are measured by bare stainless steel and by stainless steel modified by either Pt or Au NPs. We study the effect of the surface coverage of the stainless steel surface by NPs on the electrochemical response. Moreover, the stainless steel electrode was modified simultaneously by Au and Pt nanoparticles. This improved concurrently the stainless steel response (CV and potentiometry) toward two different species; l-dopa, which shows fast electron transfer on Pt, and catechol, which exhibits fast electron transfer on Au. We believe that this approach could be a first step toward developing a superior electrode for measuring the “true” Eh of complex aquatic systems.
- 16 October 2012
- Published by Wiley in Electroanalysis
- Vol. 25 (1) , 109-115
A New Electrochemical Flow Cell for the Remote Sensing of Heavy Metals
- 16 October 2012
- Published by Wiley in Electroanalysis
- Vol. 25 (1) , 109-115
A New Electrochemical Flow Cell for the Remote Sensing of Heavy Metals
- 1 January 2011
- Published by Elsevier in Analytica Chimica Acta
- Vol. 684 (1-2) , 1-7
Determination of low levels of cadmium ions by the under potential deposition on a self-assembled monolayer on gold electrode
- 1 January 2011
- Published by Elsevier in Analytica Chimica Acta
- Vol. 684 (1-2) , 1-7
Determination of low levels of cadmium ions by the under potential deposition on a self-assembled monolayer on gold electrode
- 7 September 2009
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 1 (2) , 93-99
A new approach for measuring the redox state and redox capacity in milk
Milk is one of the most fundamental ingredients in our diet. It is a complex biological fluid, which contains numerous substances, ranging from metal ions to enzymes. There is a constant search for an improved way of monitoring its quality and freshness. These are highly affected by the redox state of milk, which is governed by different species. In this study, we investigated the redox state and capacity of milk. Specifically, milk was potentiometrically titrated using different redox mediators, which enabled facilitation of electron transfer between different oxidizable species and the electrode. We found that the iodine/iodide redox couple was superior for measuring the redox capacity of milk. These measurements revealed that milk is not a well-poised system due to the presence of at least two different oxidizable species, one of which is hydrophobic while the other is hydrophilic and therefore could be separated by phase separation of milk.
- 7 September 2009
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 1 (2) , 93-99
A new approach for measuring the redox state and redox capacity in milk
Milk is one of the most fundamental ingredients in our diet. It is a complex biological fluid, which contains numerous substances, ranging from metal ions to enzymes. There is a constant search for an improved way of monitoring its quality and freshness. These are highly affected by the redox state of milk, which is governed by different species. In this study, we investigated the redox state and capacity of milk. Specifically, milk was potentiometrically titrated using different redox mediators, which enabled facilitation of electron transfer between different oxidizable species and the electrode. We found that the iodine/iodide redox couple was superior for measuring the redox capacity of milk. These measurements revealed that milk is not a well-poised system due to the presence of at least two different oxidizable species, one of which is hydrophobic while the other is hydrophilic and therefore could be separated by phase separation of milk.