JWJianqing Wang

Jianqing Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jianqing Wang has a total of 305 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analysis of Grounding Structure Effects on Automotive Ethernet Using Unshielded Twisted Pair: Experimental and Simulation Study Under Bulk Current Injection Testing

    by Teppei Ikeda, Yusuke Yano, Koji Ichikawa, Osami Wada, Jianqing Wang

    In bulk current injection (BCI) testing for an automotive Ethernet system, two electronic control units (ECUs), one as the device under test (DUT) and the other as the link partner (LP), are connected with an unshielded twisted-pair (UTP) cable, and the DUT’s immunity performance is affected by the LP’s grounding condition and system geometry. In this article, experimental evaluations are conducted by altering the enclosure-to-ground-plane grounding of the LP while keeping the DUT constant. The results indicate that differences in common-mode termination (CMT) can cause communication failures, shift failure-frequency ranges, and significantly modify the common-mode current characteristics at the connector. To interpret these phenomena, a “structure-based equivalent circuit model (SB-ECM)” that can reproduce ECUs with variable grounding conditions is developed by discretizing the ECU configuration, achieving qualitative agreement with measurements up to $\bm{\text{200}\,\text{MHz}}$. Then, a “simplified SB-ECM” is derived to identify dominant elements affecting common-mode impedance ($\mathbf {Z}_{\text{com}}$) of the CMT and to analyze the influence of the relative magnitude of $\mathbf {Z}_{\text{com}}$ levels between the DUT and LP, resonance, and antiresonance on immunity. The findings demonstrate that the grounding conditions and system geometry of both the DUT and the LP can substantially alter the injected current through the combined effects of cable-length resonance resulting from the CMT conditions. These results provide practical guidance for ECU grounding design, emphasizing the need to consider both DUT and LP conditions, accounting for parasitic capacitance and inductance in the early design stage.


  • MMSE Pre-Emphasis and Transmit Diversity for Wideband Implant Communication With Varying Antenna Orientations

    by Lijia Liu, Kota Miyazaki, Jingjing Shi, Yusuke Yano, Jianqing Wang, Yang Hao

    The 10–60 MHz human body communication (HBC) band offers high data rates and low signal attenuation for wireless implantable biomedical communications. However, implant communication faces two key challenges: limited bandwidth from antenna miniaturization and performance degradation due to directivity mismatch under varying in-body antenna orientations. To address these issues, we propose an implant communication system that combines minimum mean-square-error (MMSE) based pre-emphasis with wideband spatial transmit diversity. MMSE-based pre-emphasis mitigates inter-symbol interference (ISI) and increases bandwidth, while preserving signal-to-noise ratio (SNR) by simultaneously minimizing mean square error and power loss. Transmit diversity compensates for the difficulty in controlling implant antenna directivity, enhancing robustness through maximum ratio combining (MRC) of wideband signals. Together, the proposed techniques achieve a favorable trade-off between bandwidth and SNR, resulting in significant improvements in bit error rate (BER) performance. We validate the proposed system through simulations with an anatomical human model and experiments using a tissue-equivalent phantom. Results demonstrate reliable communication at 20 Mbps up to approximately 10 cm of implant depth, across antenna orientations from 0° to 180°, confirming its feasibility for practical implant applications.

  • Wearable AMC-Based Multimodal Antenna Sensor With GA-BP Network for Plantar Health Monitoring

    by Haoran Ma, Hanwen Miao, Jingjing Shi, Jianqing Wang

    Continuous monitoring of multiple physiological parameters provides more comprehensive diagnostic information for diabetic foot ulcer (DFU) prevention than single-parameter detection. This work proposes a wearable multimodal antenna sensor capable of simultaneous pressure and humidity sensing and designed to be compatible with wireless interrogation architectures. The antenna sensor is fabricated on a flexible polyimide (PI) substrate and integrated with a 3×3 artificial magnetic conductor (AMC) array to improve impedance matching and reduce specific absorption rate (SAR) during on-body operation. The sensing mechanism is based on resonant frequency shifts of the antenna: pressure alters the antenna-AMC spacing, while humidity modulates the dielectric constant of the PI substrate, both inducing resonance shifts. However, the shared resonant response introduces cross-sensitivity and complicates independent quantification. To address this issue, a genetic algorithm backpropagation (GA-BP) neural network is employed to enhance multi-parameter decoupling and improve prediction accuracy. Experimental characterization of the proposed antenna sensor prototype demonstrates a pressure sensitivity of 11.09 MHz/kPa and a humidity sensitivity of 1.30 MHz/RH% within the range of 40%RH-90%RH, which corresponds to DFU-risk-related moisture accumulation in the in-shoe plantar microclimate. The neural network achieves high accuracy in reconstructing independent pressure and humidity values, establishing a robust solution for coupled sensing environments. This study proposes, for the first time, a novel pressure-humidity dual-mode antenna sensor integrated with intelligent decoupling algorithms, demonstrated as a proof-of-concept prototype paving the way for advanced wearable platforms in multi-parameter continuous diabetic foot health monitoring.


  • Open Access

    The International Collaborative Animal Study of the carcinogenicity and genotoxicity of mobile phone radiofrequency radiation: the Korean study

    by Hye Sun Kim, Kang-Hyun Han, Yong-Bum Kim, Sang Bong Jeon, Ae-Kyoung Lee, Jung-Ick Moon, Hyung Do Choi, Katsumi Imaida, Masanao Yokohira, Mayumi Kawabe, et al.

    A chronic bioassay investigating radiofrequency (RF) carcinogenicity, intentionally designed to be conducted simultaneously in Korea and Japan, using the same research protocol and experimental environment. The study aimed to assess the potential carcinogenicity of Code Division Multiple Access (CDMA)-modulated 900 MHz RF signals at a whole-body specific absorption rate (SAR) of 4 W/kg, which is the reference level of the international human safety guideline, and to verify the key findings from the National Toxicology Program (NTP) study at that SAR level. Two reverberation chamber systems were used for RF exposures, and the same study protocols were followed. Male Harlan Sprague–Dawley (Hsd:Sprague Dawley SD) rats were randomly assigned to cage-control, sham-exposed, or RF-exposed groups. The exposure started on gestational day 5 and lasted for 18 h and 20 min each day, with 10-min on/off cycles. The project included a 28-d toxicity study, a 2-yr carcinogenicity study, and a 14-wk genotoxicity test. Histopathological evaluations were conducted in a partially blinded manner. The results were independently analyzed and submitted separately based on each country’s research findings. In the Korean study, no statistically significant changes in tumor incidence or survival rates were observed. No significant RF-related effects were detected in the heart, brain, or adrenal glands. No changes in body temperature. Genotoxicity tests showed no evidence of DNA damage or mutation. In conclusion, the Korean part found that long-term exposure to CDMA-modulated 900 MHz RF was neither carcinogenic nor genotoxic at a SAR of 4 W/kg in male rats. An international animal study was jointly conducted as a chronic bioassay in Japan and Korea to evaluate the carcinogenicity of mobile phone RF signals and to verify key findings from the NTP study using identical protocols and exposure systems.


  • Open Access

    The International Collaborative Animal Study of mobile phone radiofrequency radiation carcinogenicity and genotoxicity: the Japanese study

    by Katsumi Imaida, Mayumi Kawabe, Jianqing Wang, Masanao Yokohira, Norio Imai, Kang-Hyun Han, Yong-Bum Kim, Sang Bong Jeon, Hye Sun Kim, Young Hwan Ahn

    The potential carcinogenic and genotoxic effects of radiofrequency electromagnetic fields, particularly those emitted by mobile communication systems, have raised public health concerns. A previous study by the U.S. National Toxicology Program suggested increased incidences of gliomas and cardiac schwannomas in rats exposed to high levels of RF radiation. To evaluate these findings, an international collaborative study was initiated between Japan and Korea. Male Hsd:Sprague Dawley SD rats were exposed to 900 MHz CDMA-modulated RF-EMFs at a whole-body specific absorption rate of 4 W/kg for 18 h and 20 min daily over 2 yr. The study included a 28-d preliminary toxicity study, genotoxicity assays (alkaline comet and micronucleus tests), and a 2-yr carcinogenicity assessment. All procedures followed OECD guidelines and Good Laboratory Practice. No statistically significant increases in the incidences of neoplastic or non-neoplastic lesions were found in any major organ, including the brain, heart, and adrenal glands. Genotoxicity assays revealed no evidence of DNA damage or chromosomal aberrations in RF-exposed rats. A higher survival rate in the RF-exposed group, likely due to lower body weight and food consumption, was observed. This study, performed in Japan, jointly planned and executed by Japan and Korea, provides strong evidence that long-term exposure to 900 MHz RF-EMFs did not produce reproducible carcinogenic or genotoxic effects in male rats. Combined with data from the Korean counterpart study, these results are expected to contribute to future international assessments of the carcinogenic potential of electromagnetic radiation.


  • An HMM Generator With Low Load Dependency for Alternative TLP-HMM

    by Masahiro Yoshida, Yusuke Yano, Takeshi Ishida, Jianqing Wang

    Various types of transmission line pulse-human metal models (TLP-HMM) have been proposed as alternatives to electrostatic discharge (ESD) generators for immunity testing of devices because TLP-HMM generates more stable discharge current waveforms than ESD generators. The output impedance of TLP-HMM differs from that of ESD generators due to their distinct discharge mechanisms. Therefore, we focused on an HMM generator via a coaxial cable that generates discharges using RC circuits, similar to ESD generators. However, ESD generators and the HMM generator differ in terms of their output structure and calibration target. This may cause the discharge current waveforms to vary when used on a device under test (DUT). In this study, the problems caused by the differences in the output structure and calibration target were identified through equivalent circuit modeling of the HMM generator corresponding to the discharge waveform measurement of two loads in simulating DUT. Subsequently, a low load dependency-human metal model (LLD-HMM) is proposed by addressing the problems to generate same-shaped discharge current waveforms for arbitrary resistive and certain capacitive loads with arbitrary cable lengths. The effectiveness of the LLD-HMM was verified through simulations and experiments.

  • Measurement Method for Mixed-Mode S-Parameters of Termination Structure in Differential Communication Line

    by Masahiro Yoshida, Yusuke Yano, Jianqing Wang

    Bulk current injection (BCI) tests are considered an important method of evaluating the immunity of a differential communication system. Malfunctions during BCI tests are partly caused by common-mode reflection and mode conversion of electronic control units (ECUs). Their characteristics are determined by termination structures (such as connector, enclosure, and ground wiring) and components on a printed circuit board (PCB) housed in ECUs. Conventional measurement methods using current probes cannot separate the characteristics of the termination structures for ECUs on one side because the measurement results include the effects of cable length resonances and reflections at the ECUs. Furthermore, the methods cannot measure mode conversions between the differential and common modes because currently, the current probe measures only the common mode. Thus, we cannot obtain an accurate model of the ECU on one side in the differential communication system. This study proposes a method to measure mixed-mode S-parameters of the termination structures for the ECU on one side using a current probe. We designed the load simulator on the other side to suppress the reflection and mode conversion using matched termination and balanced circuit. Consequently, we measured only the equipment under test (EUT) characteristics without cable length resonances. In addition, we placed two ports on the PCB instead of an IC to measure transmission through the EUT. Subsequently, we measured the characteristics including mode conversions. Furthermore, the effectiveness of this method was verified by SPICE simulation and experiment. In the experiment, experimental and theoretical results were compared considering measurement errors.


  • Novel Multiband Antenna Design and Performance Evaluation for Wireless Electronic Capsule Systems

    by Hailian Liu, Jingjing Shi, Le Song, Lijia Liu, Yukang Wang, Tonglei Cheng, Jianqing Wang

    In this work, a novel miniaturized multi-resonant conformal antenna system has been proposed for wireless electronic capsule applications. It consists of a swallowable in-body antenna and two kinds of spiral/meandering on-body antennas with a simple structure and a low profile. The in-body transmitting antenna has a hollow cylinder-like structure with a size of $\pi \times 8^{2} \times$ 26 mm $^{3}$ , which is a combination of a helical spiral conformed on a flexible substrate and a planar spiral on a high dielectric substrate, to generate multi-resonant frequencies. It operates in three bands, Medical Implanted Communication Service (MICS) band (402 $-$ 405 MHz), Wireless Medical Telemetry Service (WMTS) band (1427 $-$ 1432 MHz), and the Industrial, Scientific, and Medical (ISM) band (2.4 $-$ 2.4835 GHz). The on-body receiving antennas have a planar spiral structure with a size of 20 × 6.8 × 27 mm $^{3}$ and a planar meandered structure with a size of 42 × 10 × 1.6 mm $^{3}$ , respectively, which are suitable for wearable terminals. The performance of the proposed antenna system is analyzed and validated using a muscle-equivalent model, a multi-layer tissue model, a numerical human model in simulations, and a liquid phantom in experiments. Simulation and experimental results show the good potential of the antenna system for intra-body communication scenarios such as wireless electronic capsules.