Stanislao D'AUria
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stanislao D'AUria has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Massimo Mondani
Neurosurgery Unit, S. Maria della Misericordia University Hospital, Udine, Italy
5 shared publicationsRoberto Eleopra
Unità Operativa di Neurologia, Neurofisiopatologia, A.O. S. Maria della Misericordia, Udine, Italy
4 shared publicationsSara Rinaldo
Unità Operativa di Neurologia, Neurofisiopatologia, A.O. S. Maria della Misericordia, Udine, Italy
4 shared publicationsMiran Skrap
Unità Operativa di Neurochirurgia, A.O. S. Maria della Misericordia, Udine, Italy
3 shared publications- Barbara Tomasino
Scientific Institute, IRCCS E. Medea, Dipartimento/Unità Operativa Pasian di Prato, Italy
2 shared publications - Christian Lettieri
Neurology Unit, 'S. Maria della Misericordia' University Hospital, Udine, Italy
2 shared publications
Latest Publications
- Open Access
- 31 October 2024
- Published by The Korean Movement Disorder Society in Journal of Movement Disorders
- Vol. 17 (4) , 442-446
Monitoring Cognitive Functions During Deep Brain Stimulation Interventions by Real Time Neuropsychological Testing
Objective We monitored cognition in 14 Parkinson’s disease (PD) patients during deep brain stimulation (DBS) surgery when the electrode was positioned at the target subthalamic nucleus (STN) (i.e., the STN motor area).Methods We present the DBS-real-time neuropsychological testing (DBS-RTNT) protocol and our preliminary experience with it; we also compared the intraoperative patient performance with the baseline data.Results Compared with the baseline data, patients undergoing DBS-RTNT in the target area demonstrated a significantly decreased performance on some tasks belonging to the memory and executive function domains. Patients undergoing right hemisphere DBS-RTNT had significantly lower short-term memory and sequencing scores than did patients undergoing left hemisphere DBS-RTNT.Conclusion PD patient cognitive performance should be monitored during DBS surgery, as STN-DBS may induce changes. These preliminary data contribute to improving our understanding of the anatomo-functional topography of the STN during DBS surgery, which will enable the identification of the best site for producing positive motor effects without causing negative cognitive and/or emotional changes in individual patients in the future. In principle, medications (i.e., patients who underwent surgery in a levodopa-off state) could have influenced our results; therefore, future studies are needed to address the possible confounding effects of levodopa use.
- 31 October 2024
- Published by The Korean Movement Disorder Society in Journal of Movement Disorders
- Vol. 17 (4) , 442-446
Open AccessMonitoring Cognitive Functions During Deep Brain Stimulation Interventions by Real Time Neuropsychological Testing
Objective We monitored cognition in 14 Parkinson’s disease (PD) patients during deep brain stimulation (DBS) surgery when the electrode was positioned at the target subthalamic nucleus (STN) (i.e., the STN motor area).Methods We present the DBS-real-time neuropsychological testing (DBS-RTNT) protocol and our preliminary experience with it; we also compared the intraoperative patient performance with the baseline data.Results Compared with the baseline data, patients undergoing DBS-RTNT in the target area demonstrated a significantly decreased performance on some tasks belonging to the memory and executive function domains. Patients undergoing right hemisphere DBS-RTNT had significantly lower short-term memory and sequencing scores than did patients undergoing left hemisphere DBS-RTNT.Conclusion PD patient cognitive performance should be monitored during DBS surgery, as STN-DBS may induce changes. These preliminary data contribute to improving our understanding of the anatomo-functional topography of the STN during DBS surgery, which will enable the identification of the best site for producing positive motor effects without causing negative cognitive and/or emotional changes in individual patients in the future. In principle, medications (i.e., patients who underwent surgery in a levodopa-off state) could have influenced our results; therefore, future studies are needed to address the possible confounding effects of levodopa use.
- 1 January 2019
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 97 (5-6) , 337-346
Frameless Deep Brain Stimulation Surgery: A Single-Center Experience and Retrospective Analysis of Placement Accuracy of 220 Electrodes in a Series of 110 Patients
Background: Proper lead placement is considered one of the key factors in achieving a good clinical outcome in deep brain stimulation (DBS), but there is still considerable controversy surrounding the accuracy of the frameless in comparison to the frame-based technique. Objective: We report our single-center experience with DBS electrode placement to evaluate the accuracy of the frameless stereotactic system. Methods: We prospectively analyzed the data of 110 patients who underwent DBS surgery for Parkinson disease, dystonia, essential tremor, or refractory epilepsy. The final targets (FTs) of the 220 leads were: subthalamic nucleus, globus pallidus pars interna, ventralis intermedius nucleus, and anterior nuclei of thalamus in thalamus. A bilateral stereotactic approach using a combined identification of target based on preoperative images (MRI and CT scan fusion) and intra-operative micro-electrode recording (MER) were done. We collected and compared the coordinates of planned target (PT), the definitive expected target (ET) during MER, and the effective final location (FT) of the lead using the postoperative CT. Accuracy was assessed by both vector error (VE) and deviation from the PT. Results: The mean and SD from PTs was 0.78 ± 0.43 mm in the x direction, 0.68 ± 0.41 mm in the y direction, and 0.76 ± 0.41 mm in the z direction. Global VE was 1.43 ± 0.37. Conclusion: Frameless systems appear to be a reliable and accurate technique.
- 1 January 2019
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 97 (5-6) , 337-346
Frameless Deep Brain Stimulation Surgery: A Single-Center Experience and Retrospective Analysis of Placement Accuracy of 220 Electrodes in a Series of 110 Patients
Background: Proper lead placement is considered one of the key factors in achieving a good clinical outcome in deep brain stimulation (DBS), but there is still considerable controversy surrounding the accuracy of the frameless in comparison to the frame-based technique. Objective: We report our single-center experience with DBS electrode placement to evaluate the accuracy of the frameless stereotactic system. Methods: We prospectively analyzed the data of 110 patients who underwent DBS surgery for Parkinson disease, dystonia, essential tremor, or refractory epilepsy. The final targets (FTs) of the 220 leads were: subthalamic nucleus, globus pallidus pars interna, ventralis intermedius nucleus, and anterior nuclei of thalamus in thalamus. A bilateral stereotactic approach using a combined identification of target based on preoperative images (MRI and CT scan fusion) and intra-operative micro-electrode recording (MER) were done. We collected and compared the coordinates of planned target (PT), the definitive expected target (ET) during MER, and the effective final location (FT) of the lead using the postoperative CT. Accuracy was assessed by both vector error (VE) and deviation from the PT. Results: The mean and SD from PTs was 0.78 ± 0.43 mm in the x direction, 0.68 ± 0.41 mm in the y direction, and 0.76 ± 0.41 mm in the z direction. Global VE was 1.43 ± 0.37. Conclusion: Frameless systems appear to be a reliable and accurate technique.
- 10 July 2014
- Published by Wiley in European Journal of Neurology
- Vol. 22 (6) , 919-926
Clinical outcome of deep brain stimulation for dystonia: constant‐current or constant‐voltage stimulation? A non‐randomized study
Background and purpose: Bilateral globus pallidus deep brain stimulation (GPi‐DBS) represents an effective and relatively safe therapy for different forms of refractory dystonia. The aim of this study was to assess, retrospectively, the effect of two different stimulation settings during GPi‐DBS in 22 patients affected by primary generalized or multi‐segmental dystonia.Methods: Thirteen patients were stimulated using a voltage‐controlled setting whilst in the other nine patients a current‐controlled setting was used. Clinical features were evaluated for each patient at baseline, 6 months and 12 months after surgery by means of the Burke−Fahn−Marsden Dystonia Rating Scale.Results: Globus pallidus deep brain stimulation was effective in all patients. However, comparing constant‐current and constant‐voltage stimulation, a better outcome was found in the current‐controlled group during the last 6 months of follow‐up.Conclusions: Current‐controlled stimulation is effective during GPi‐DBS for primary dystonia and it could be a better choice than voltage‐controlled stimulation over long‐term follow‐up.
- 10 July 2014
- Published by Wiley in European Journal of Neurology
- Vol. 22 (6) , 919-926
Clinical outcome of deep brain stimulation for dystonia: constant‐current or constant‐voltage stimulation? A non‐randomized study
Background and purpose: Bilateral globus pallidus deep brain stimulation (GPi‐DBS) represents an effective and relatively safe therapy for different forms of refractory dystonia. The aim of this study was to assess, retrospectively, the effect of two different stimulation settings during GPi‐DBS in 22 patients affected by primary generalized or multi‐segmental dystonia.Methods: Thirteen patients were stimulated using a voltage‐controlled setting whilst in the other nine patients a current‐controlled setting was used. Clinical features were evaluated for each patient at baseline, 6 months and 12 months after surgery by means of the Burke−Fahn−Marsden Dystonia Rating Scale.Results: Globus pallidus deep brain stimulation was effective in all patients. However, comparing constant‐current and constant‐voltage stimulation, a better outcome was found in the current‐controlled group during the last 6 months of follow‐up.Conclusions: Current‐controlled stimulation is effective during GPi‐DBS for primary dystonia and it could be a better choice than voltage‐controlled stimulation over long‐term follow‐up.
- 1 July 2014
- Published by Elsevier in Brain Research
- Vol. 1574, 14-25
To move or not to move: Subthalamic deep brain stimulation effects on implicit motor simulation
- 1 July 2014
- Published by Elsevier in Brain Research
- Vol. 1574, 14-25
To move or not to move: Subthalamic deep brain stimulation effects on implicit motor simulation
- 1 June 2014
- Published by Elsevier in Sleep Medicine
- Vol. 15 (6) , 637-641
Microsubthalamotomy improves sleep in patients affected by advanced Parkinson’s disease
- 1 June 2014
- Published by Elsevier in Sleep Medicine
- Vol. 15 (6) , 637-641
Microsubthalamotomy improves sleep in patients affected by advanced Parkinson’s disease
- 1 December 2012
- Published by Elsevier in Clinical Neurophysiology
- Vol. 123 (12) , 2406-2413
Deep brain stimulation: Subthalamic nucleus electrophysiological activity in awake and anesthetized patients
- 1 December 2012
- Published by Elsevier in Clinical Neurophysiology
- Vol. 123 (12) , 2406-2413
Deep brain stimulation: Subthalamic nucleus electrophysiological activity in awake and anesthetized patients