Frameless Deep Brain Stimulation Surgery: A Single-Center Experience and Retrospective Analysis of Placement Accuracy of 220 Electrodes in a Series of 110 Patients
- 1 January 2019
- journal article
- research article
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 97 (5-6) , 337-346
Abstract
Background: Proper lead placement is considered one of the key factors in achieving a good clinical outcome in deep brain stimulation (DBS), but there is still considerable controversy surrounding the accuracy of the frameless in comparison to the frame-based technique. Objective: We report our single-center experience with DBS electrode placement to evaluate the accuracy of the frameless stereotactic system. Methods: We prospectively analyzed the data of 110 patients who underwent DBS surgery for Parkinson disease, dystonia, essential tremor, or refractory epilepsy. The final targets (FTs) of the 220 leads were: subthalamic nucleus, globus pallidus pars interna, ventralis intermedius nucleus, and anterior nuclei of thalamus in thalamus. A bilateral stereotactic approach using a combined identification of target based on preoperative images (MRI and CT scan fusion) and intra-operative micro-electrode recording (MER) were done. We collected and compared the coordinates of planned target (PT), the definitive expected target (ET) during MER, and the effective final location (FT) of the lead using the postoperative CT. Accuracy was assessed by both vector error (VE) and deviation from the PT. Results: The mean and SD from PTs was 0.78 ± 0.43 mm in the x direction, 0.68 ± 0.41 mm in the y direction, and 0.76 ± 0.41 mm in the z direction. Global VE was 1.43 ± 0.37. Conclusion: Frameless systems appear to be a reliable and accurate technique.Keywords
This publication has 36 references indexed in Scilit:
- Deep brain stimulation: Subthalamic nucleus electrophysiological activity in awake and anesthetized patientsClinical Neurophysiology, 2012
- Analysis of Stereotactic Accuracy of the Cosman-Robert-Wells Frame and Nexframe Frameless Systems in Deep Brain Stimulation SurgeryStereotactic and Functional Neurosurgery, 2010
- Nexframe Frameless Stereotaxy with Multitract Microrecording: Accuracy Evaluated by Frame-Based Stereotactic X-RayStereotactic and Functional Neurosurgery, 2010
- Electrical stimulation of the anterior nucleus of thalamus for treatment of refractory epilepsyEpilepsia, 2010
- Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracyJournal of Neurosurgery, 2010
- Accuracy and Distortion of Deep Brain Stimulation Electrodes on Postoperative MRI and CTCentral European Neurosurgery, 2008
- Assessment of Contact Location in Subthalamic Stimulation for Parkinson’s Disease by Co-Registration of Computed Tomography ImagesStereotactic and Functional Neurosurgery, 2008
- Achieving Optimal Accuracy in Frameless Functional Neurosurgical ProceduresStereotactic and Functional Neurosurgery, 2008
- Bilateral Deep-Brain Stimulation of the Globus Pallidus in Primary Generalized DystoniaNew England Journal of Medicine, 2005
- Accuracy in Frame-Based and Frameless StereotaxyStereotactic and Functional Neurosurgery, 1993