  • Design and Evaluation of a 2.5D-Assembled High-Density Detection Module for the Ultrahigh Resolution Brain PET Scanner

    by Jonathan Bouchard, Arnaud Samson, Romain Espagnet, Caroline Paulin, Nicolas Viscogliosi, Jean-François Beaudoin, Louis Arpin, Charles Bourcier-Guérette, Roger Lecomte, Réjean Fontaine

    The LabPET II modular technology was identified as a promising platform for a new generation of Ultra-High Resolution (UHR) brain PET scanners. Scaling up from preclinical systems to achieve a human brain field-of-view introduces significant challenges that require high-density, low-noise detection modules capable of dissipating over 1.1 kW of heat within a confined volume. To address these constraints, a new UHR detection module, referred to as the UHR-DM, was developed based on a 2.5D stacked PCB architecture. This design embeds two readout ASICs between two circuit boards to enhance thermal management, mechanical alignment, and electrical performance, while preserving full backward compatibility with the existing LabPET II platform. This paper presents a detailed comparison between the UHR-DM and the original LabPET II detection module (LP2-DM). Key improvements include improved heat extraction through direct conduction, reduced parasitic capacitance via shorter and more uniform trace routing, and enhanced noise immunity enabled by embedded shielding. A dedicated testbench was used to evaluate thermal performance, baseline stability, noise characteristics, intrinsic and full-system coincidence time resolution (CTR), and time-over-threshold (ToT) energy resolution. Results show that the UHR-DM design reduces ASIC operating temperature by up to 43%, lowers noise by 60% when using high electronic gains, and improves channel-to-channel noise uniformity. It also achieves more consistent CTR and energy resolution without compromising any performance aspect of the original design. These enhancements will facilitate the upcoming integration all 129 024 individual channels required by the UHR brain PET scanner to achieve a spatial resolution of 1.25 mm at the center of the field of view.

  • Fully-Flexible Multifunctional Polydimethylsiloxane (PDMS) Neural Probe With a U-Turn Polyester Microchannel

    by Mohammad Makhdoumi Akram, Amir Aghajani, Jonathan Lévesque, Réjean Fontaine, Frédéric Nabki, Wei Shi, Benoit Gosselin

    Objective: This study aims to develop a flexible, implantable neural probe with tunable stiffness and multifunctionality for electrophysiology, drug delivery, and optogenetics, while minimizing immune response. Methods: The probe was fabricated from polydimethylsiloxane (PDMS) with a U-turn polyester-filled microchannel (30 μm × 30 μm, 14.7 mm length). Polyester provides rigidity at room temperature and softens near body temperature for tissue compatibility. Mechanical simulations optimized probe dimensions (60 μm × 300 μm × 7 mm), ensuring insertion forces above 1.5 mN. A microfluidic mixer (90 μm × 30 μm, 7 mm) was integrated for controlled drug delivery. Heat transfer and fluid simulations assessed thermal stability and laminar flow. The device also included four gold electrodes, a bio-amplifier, and a blue μ-LED. Results: Experiments confirmed stable channel performance with no leaks or bubbles, effective heat management at 37°C, and a 60° tip angle as optimal for insertion. The probe consumed ∼46.6 mW and enabled reliable electrophysiological recordings and fluorescence activation in vitro. Biocompatibility testing validated its suitability for long-term implantation. Conclusion: The PDMS–polyester probe achieves thermally controlled stiffness, precise drug delivery, and integrated optogenetic stimulation while maintaining stable electrophysiological recording performance. Significance: This work introduces a multifunctional neural probe that addresses limitations of rigid implants by combining flexibility, drug delivery, and optogenetics. The platform has strong potential for advancing long-term neuroengineering applications, reducing tissue response, and enabling multimodal brain interfacing.

  • An Ultra-Compact and Fully Integrated Tunable IR-UWB Transmitter in 28-nm CMOS for High-Density Neural Implants

    by Esmaeil Ranjbar Koleibi, Reza Bostani, Konin Koua, William Lemaire, Benoit Gosselin, Sébastien Roy, Frédéric Nabki, Réjean Fontaine

    This paper presents a fully-CMOS, tunable impulse radio ultra-wideband (IR-UWB) transmitter for high-density implantable neural recording systems. Fabricated in 28 nm CMOS technology, the transmitter features an ultra-compact edge-combining architecture based on a digitally tunable impulse response filter (IRF) occupying only $0.0027~ {\mathrm {\text {m}\text {m} ^{2}}}$ . The measured output exhibits a central frequency of $4.5~ {\mathrm {\text {G}\text {Hz} }}$ with a 10-dB bandwidth of $3.6~ {\mathrm {\text {G}\text {Hz} }}$ , providing robust spectral performance. It achieves $1~ {\mathrm {\text {G}\text {Hz} }}$ frequency tunability by adjusting pulse widths from $650~ {\mathrm {\text {p}\text {s} }}$ to $800~ {\mathrm {\text {p}\text {s} }}$ , ensuring compliance with FCC spectral masks. A current-starved ring VCO (CSRVCO), with a compact $150~ {\mathrm {\mu \text {m} ^{2}}}$ layout, serves as the clock source, offering wide frequency tuning, low power consumption, and enhanced output power. The transmitter employs On-Off Keying (OOK) modulation and delivers a peak output amplitude of $660~ {\mathrm {\text {m}\text {V} }}$ with up to 5.1% energy efficiency. At a $20~ {\mathrm {\text {M}\text {Hz} }}$ pulse repetition rate, the transmitter consumes only $78~ {\mathrm {\mu \text {W} }}$ while producing -24.5dBm of output power. Measurement results confirm compliance with FCC regulations and suitability for deep implantation in biomedical applications. The design achieves a competitive Figure-of-Merit (FoM) of $0.017~({\mathrm {\text {m}\text {m} ^{2}}} \cdot {\mathrm {\text {p}\text {J} }}) / (\text {b} \cdot {\mathrm {\text {V}}})$ , demonstrating its scalability and efficiency compared to prior state-of-the-art solutions.

  • A 1.6-fJ/Spike Subthreshold Analog Spiking Neuron in 28 nm CMOS

    by Marwan Besrour, Takwa Omrani, Jacob Lavoie, Samuel Bouchard, Gabriel Martin-Hardy, Esmaeil Koleibi, Jeremy Menard, Konin Koua, Philippe Marcoux, Mounir Boukadoum, et al.

  • Readout Techniques and Offset Compensation Strategies for Biomedical Resistive MEMS Sensors: A Comprehensive Review

    by Reza Bostani, Esmaeil Ranjbar Koleibi, Gabriel Gagnon-Turcotte, Réjean Fontaine, Sharmistha Bhadra, Benoit Gosselin

    Resistive MEMS sensors have become increasingly significant in biomedical and bioenvironmental monitoring due to their compact dimensions, low energy demand, and high sensitivity. Despite structural simplicity and integration benefits, these sensors face performance constraints arising from intrinsic nonidealities such as nonlinearity, thermal drift, parasitic interactions, and process mismatches. These limitations intensify at micro and nanoscale dimensions and generate substantial DC offset in the output. This review presents a systematic analysis of resistive sensor architectures, including single resistor, half bridge, and full bridge configurations, and evaluates their susceptibility to distortion and noise through analytical modeling. Comparative assessment reveals tradeoffs in sensitivity, linearity, noise resilience, and thermal stability. The paper also examines advanced readout methodologies designed for precision measurement, low power operation, and compact integration, including voltage to voltage, voltage to frequency, resistance to digital, and RC delay based interfaces. Particular emphasis is placed on DC offset compensation strategies that address sensor nonidealities, such as resistive, current driven, and capacitive DAC techniques, implemented across different stages of the signal chain. These approaches are critically appraised for their effectiveness in extending dynamic range, reducing energy consumption, and preserving signal fidelity in implantable and wearable platforms. The survey synthesizes recent designs and proposes a classification framework to guide the selection of interface and compensation strategies designed to sensor topology and application constraints. By integrating theoretical insights with practical design considerations, this work provides a comprehensive reference for developing robust, precise, and energy efficient resistive sensor interfaces.


  • Open Access

    Study of dose reduction in computed tomography using a time-of-flight scatter rejection mechanism in a 3D voxelized phantom

    by G Bélanger, J Rossignol, Y Bérubé-Lauzière, R Fontaine

    Objective . Scattered photons are the main source of contrast degradation in x-ray imaging when not filtered out appropriately. Measuring the time-of-flight (ToF) of x-ray photons has recently been revisited as an innovative way to discriminate between primary and scattered photons without significant loss in sensitivity in order to improve the contrast-to-noise ratio (CNR) in radiography and computed tomography (CT). The technique could allow for the removal of the anti-scatter grid (ASG) while still producing a CNR comparable to that of a fan-beam CT, allowing for potential dose reduction and more uniform axial spatial resolution when used in a cone-beam configuration. Approach . This work presents an evaluation study of the potential reduction in absorbed radiation dose in the body during a CT image acquisition when using time-correlated single photon counting CT in a cone-beam geometry. A comparative study is carried out using Monte Carlo simulations in GEANT4 Application for Tomographic Emission of a voxelized body of an adult female for a multi-slice fan beam CT scanner and a cone beam system using ToF measurements with various timing jitters or ASGs. Main results . For CNR equivalent torso images, simulation data in the high contrast region for ToF of 10, 50, 100, 200 ps full width at half maximum (FWHM) timing jitters show a dose reduction of 35%, 28%, 15%, 5% respectively compared to cone-beam CT with an ASG. Compared to a fan-beam setup without an ASG, the cone-beam ToF CT achieved a dose reduction of 13% and 4% for 10 and 50 ps FWHM timing jitter respectively, and an increase of 13% and 26% at 100 and 200 ps timing jitter. In the low contrast region, 10 ps ToF led to a reduction in dose of 15% and 50 ps led to an increase of 5%. Resolutions above 100 ps failed to accurately reject scattered photons and led to a considerable increase in dose. Significance . ToF scatter rejection shows potential for reducing radiation dose while preserving image quality when the timing resolution is 50 ps FWHM or better, but better ToF-based scatter rejection algorithms are required to enable this method for worse timing resolutions and low contrast regions.

  • A Multifunctional and Flexible Implantable Electrooptic Neural Probe With Embedded Micropump and Precise Flowmeter

    by Mohammad Makhdoumi Akram, Amir Aghajani, Réjean Fontaine, Frédéric Nabki, Wei Shi, Benoit Gosselin

    In this study, we introduce a multifunctional and flexible neural probe that includes a microlight-emitting diode ( $\mu $ -LED) for fluorescence excitation and optogenetics sensing, a micropump for drug delivery, and microelectrodes for electrophysiological recording. The microprobe has dimensions of 0.7 mm (W), 0.1 mm (H), and 10 mm (L). It integrates a polydimethylsiloxane (PDMS)-based micropump that operates through an electrolysis reaction at room temperature, a precise flowmeter for drug delivery, a $\mu $ -LED for neural stimulation, and four electrodes for recording action potentials. In addition, the probe includes a flexible printed circuit board (Flex-PCB) equipped with a bio-amplifier, LED driver, RF transceiver, and a microcontroller (MCU) to control the LED, capture and digitize brain activity, and to transmit neural data to a computer nearby. The MCU includes a proportional–integral–derivative (PID) controller and an analog-to-digital converter (ADC) for recording electrophysiological signals and measuring flow rate during experiments. The PDMS-based micropump contains a potassium hydroxide (KOH) reservoir for water electrolysis, a flexible membrane, a drug reservoir, and microfluidic channels for drug delivery, each with a capacity of $20~\mu $ L. This capacity allows for a duration of 1 h of continuous flow at the highest rate of 250 nL/min. Parallel gold-plated electrodes are integrated to function as a capacitance-based flowmeter, accurately measuring flow rates from 30 to 250 nL/min with an error margin of about 5% and a resolution of 20 pF per 100 pL/min. The PID controller maintains the desired flow rate by adjusting the pulsewidth modulation (PWM) duty cycle of the micropump driver. The probe also features four gold-plated square electrodes ( $125~\mu $ m in diameter) for capturing electrophysiological signals and a blue $\mu $ -LED for optogenetic stimulation or fluorescence excitation. It was tested in vitro to evaluate its performance in realistic experimental conditions. The probe, weighing just 1.5 g, is suitable for various neuroscience applications.

  • Energy-efficient spiking neural network implementation for a retinal prosthesis

    by Marwan Besrour, Jacob Lavoie, Takwa Omrani, Jérémy Ménard, Esmaeil Ranjbar-Koleibi, Gabriel Martin-Hardy, Konin Koua, Mounir Boukadoum, Réjean Fontaine

    The quest for visual rehabilitation via retinal implant technology remains a complex, multi-dimensional endeavor. Retinal implants are biomedical devices surgically introduced into the ocular region. ...

  • Open Access

    Shivering, but not adipose tissue thermogenesis, increases as a function of mean skin temperature in cold-exposed men and women

    by Lauralyne Dumont, Gabriel Richard, Romain Espagnet, Frédérique Frisch, Mélanie Fortin, Arnaud Samson, Jonathan Bouchard, Réjean Fontaine, Etienne Croteau, Serge Phoenix, et al.

    SUMMARY: Skin cooling results in the activation of heat generating mechanisms to counteract heat lost to the environment. Here, we aim to understand the extent that variations in cold-stimulated heat production may be driven by differences in the contribution of shivering and non-shivering thermogenesis (NST) and the interaction with biological sex. Using a novel mean skin temperature clamping technique in healthy men and women, our data shows that cold-stimulated heat production rises with increasing shivering and myocardial oxidative metabolism in a skin temperature-dependent fashion. Shivering and myocardial thermogenesis were also moderately associated. In contrast, adipose tissue NST did not increase in a linear manner to reductions in skin temperature. Men and women displayed similar thermoregulatory responses, although women presented more pronounced shivering through a greater recruitment of lower-body muscles and greater number of motor units recruited. Thus, shivering contributes proportionally to cold-induced thermogenesis whereas adipose tissue thermogenesis displays an all-or-none response.

  • Open Access

    Study of the TOFPET2c ASIC in time-of-flight detection of x-rays for scatter rejection in medical imaging applications

    by L-D Gaulin, V Nadig, K Herweg, G Lemaire, F Gagnon, J Bouchard, J Rossignol, V Schulz, R Fontaine, S Gundacker

    Objective. Integrating time-of-flight (ToF) measurements in radiography and computed tomography (CT) enables an approach for scatter rejection in imaging systems that eliminates the need for anti-scatter grids, potentially increasing system sensitivity and image quality. However, present hardware dedicated to the time-correlated measurement of x-rays is limited to a single pixel physically too large for the desired spatial resolution. A switch to highly integrated electronics and detectors is needed to progress towards detector arrays capable of acquiring images, while offering a timing resolution below 300 ps FWHM to achieve scatter rejection comparable to current anti-scatter grids. Approach. Using off-the-shelf scintillators, photodetectors and readouts designed for ToF positron emission tomography (PET) provides a preliminary evaluation of available highly integrated readout systems supporting detector arrays for ToF scatter rejection. The TOFPET2c ASIC from PETSys offers an established development platform necessary for fast and reliable results, with no known limitation regarding time-correlated detection of medical imaging x-rays (20–140 keV). Main results. Reliable photon detection down to 31 keV was achieved, reaching energy resolutions from 23% to 92% FWHM throughout the desired energy range. Optimal detector timing resolution (DTR) from 250 ps FWHM at 130 keV to 678 ps FWHM at 30 keV was reached. Strong time walk effects were observed, showing a time shift of 642 ps up to 1740 ps between events spanning the energies used in x-ray medical imaging. Significance. The TOFPET2c ASIC has shown its potential for ToF scatter rejection, but meets the time resolution requirement of 300 ps FWHM only for limited energies (110–140 keV). This significant timing degradation observed at lower energies limits the use of the TOFPET2c ASIC for ToF scatter rejection, but offers significant advancements regarding the understanding of the phenomenon arising from the time-correlated detection of medical imaging x-rays.