    Study of dose reduction in computed tomography using a time-of-flight scatter rejection mechanism in a 3D voxelized phantom

    by G Bélanger, J Rossignol, Y Bérubé-Lauzière, R Fontaine

    Objective . Scattered photons are the main source of contrast degradation in x-ray imaging when not filtered out appropriately. Measuring the time-of-flight (ToF) of x-ray photons has recently been revisited as an innovative way to discriminate between primary and scattered photons without significant loss in sensitivity in order to improve the contrast-to-noise ratio (CNR) in radiography and computed tomography (CT). The technique could allow for the removal of the anti-scatter grid (ASG) while still producing a CNR comparable to that of a fan-beam CT, allowing for potential dose reduction and more uniform axial spatial resolution when used in a cone-beam configuration. Approach . This work presents an evaluation study of the potential reduction in absorbed radiation dose in the body during a CT image acquisition when using time-correlated single photon counting CT in a cone-beam geometry. A comparative study is carried out using Monte Carlo simulations in GEANT4 Application for Tomographic Emission of a voxelized body of an adult female for a multi-slice fan beam CT scanner and a cone beam system using ToF measurements with various timing jitters or ASGs. Main results . For CNR equivalent torso images, simulation data in the high contrast region for ToF of 10, 50, 100, 200 ps full width at half maximum (FWHM) timing jitters show a dose reduction of 35%, 28%, 15%, 5% respectively compared to cone-beam CT with an ASG. Compared to a fan-beam setup without an ASG, the cone-beam ToF CT achieved a dose reduction of 13% and 4% for 10 and 50 ps FWHM timing jitter respectively, and an increase of 13% and 26% at 100 and 200 ps timing jitter. In the low contrast region, 10 ps ToF led to a reduction in dose of 15% and 50 ps led to an increase of 5%. Resolutions above 100 ps failed to accurately reject scattered photons and led to a considerable increase in dose. Significance . ToF scatter rejection shows potential for reducing radiation dose while preserving image quality when the timing resolution is 50 ps FWHM or better, but better ToF-based scatter rejection algorithms are required to enable this method for worse timing resolutions and low contrast regions.

  • Open Access

    Study of the TOFPET2c ASIC in time-of-flight detection of x-rays for scatter rejection in medical imaging applications

    by L-D Gaulin, V Nadig, K Herweg, G Lemaire, F Gagnon, J Bouchard, J Rossignol, V Schulz, R Fontaine, S Gundacker

    Objective. Integrating time-of-flight (ToF) measurements in radiography and computed tomography (CT) enables an approach for scatter rejection in imaging systems that eliminates the need for anti-scatter grids, potentially increasing system sensitivity and image quality. However, present hardware dedicated to the time-correlated measurement of x-rays is limited to a single pixel physically too large for the desired spatial resolution. A switch to highly integrated electronics and detectors is needed to progress towards detector arrays capable of acquiring images, while offering a timing resolution below 300 ps FWHM to achieve scatter rejection comparable to current anti-scatter grids. Approach. Using off-the-shelf scintillators, photodetectors and readouts designed for ToF positron emission tomography (PET) provides a preliminary evaluation of available highly integrated readout systems supporting detector arrays for ToF scatter rejection. The TOFPET2c ASIC from PETSys offers an established development platform necessary for fast and reliable results, with no known limitation regarding time-correlated detection of medical imaging x-rays (20–140 keV). Main results. Reliable photon detection down to 31 keV was achieved, reaching energy resolutions from 23% to 92% FWHM throughout the desired energy range. Optimal detector timing resolution (DTR) from 250 ps FWHM at 130 keV to 678 ps FWHM at 30 keV was reached. Strong time walk effects were observed, showing a time shift of 642 ps up to 1740 ps between events spanning the energies used in x-ray medical imaging. Significance. The TOFPET2c ASIC has shown its potential for ToF scatter rejection, but meets the time resolution requirement of 300 ps FWHM only for limited energies (110–140 keV). This significant timing degradation observed at lower energies limits the use of the TOFPET2c ASIC for ToF scatter rejection, but offers significant advancements regarding the understanding of the phenomenon arising from the time-correlated detection of medical imaging x-rays.


  • Open Access

    Scatter estimation and correction using time-of-flight and deconvolution in x-ray medical imaging

    by Julien Rossignol, Gabriel Bélanger, Maëlle Fromont, Audrey Corbeil Therrien, Réjean Fontaine, Yves Bérubé-Lauzière

    Objective. Time-of-flight (TOF) scatter rejection requires a total timing jitter, including the detector timing jitter and the x-ray source’s pulses width, of 50 ps or less to mitigate most of the effects of scattered photons in radiography and CT imaging. However, since the total contribution of the source and detector to the timing jitter can be retrieved during an acquisition with nothing between the source and detector, it can be demonstrated that this contribution may be partially removed to improve the image quality. Approach. A scatter correction method using iterative deconvolution of the measured time point-spread function estimates the number of scattered photons detected in each pixel. To evaluate the quality of the estimation, GATE was used to simulate the radiography of a water cylinder with bone inserts, and a head and torso in a system with total timing jitters from 100 ps up to 500 ps full-width-at-half-maximum (FWHM). Main results. With a total timing jitter of 200 ps FWHM, 89% of the contrast degradation caused by scattered photons was recovered in a head and torso radiography, compared to 28% with a simple time threshold method. Corrected images using the estimation have a percent root-mean square error between 2% and 14% in both phantoms with timing jitters from 100 to 500 ps FWHM which is lower than the error achieved with scatter rejection alone at 100 ps FWHM. Significance. TOF x-ray imaging has the potential to mitigate the effects of the scattering contribution and offers an alternative to anti-scatter grids that avoids loss of primary photons. Compare to simple TOF scatter rejection using only a threshold, the deconvolution estimation approach has lower requirements on both the source and detector. These requirements are now within reach of state-of-the-art systems.


  • Comparative Study of Image Quality in Time-Correlated Single-Photon Counting Computed Tomography

    by David Gaudreault, Julien Rossignol, Yves Berube-Lauziere, Rejean Fontaine

    Computed tomography (CT) is widely used in medical imaging to reconstruct a three-dimensional image of a patient. To limit the radiation dose applied to patients, researches focuses on reducing the statistical noise or increasing the contrast in the image. Recently, time-correlated single photon counting (TCSPC) CT -also known as time-of-flight CT -has been proposed to reduce scatter contribution to images and its negative effects on image quality. This technique uses the time-of-flight information of X-ray photons to sort out scattered and ballistic photons without energy measurement. This paper compares simulated images quality obtained from different CT scanner implementations (fan-beam, cone-beam with and without anti-scatter grids, and TCSPC). The contrast-to-noise ratio (CNR), the scattered-to-primary ratio (SPR), the inaccuracy of the computed attenuation value and the cup artifact magnitude are used as comparison metrics to study the overall sensitivity of the different scanner implementations to scatter contribution. Using timing jitters of 200 ps, 100 ps and 50 ps, the simulations demonstrate that the TCSPC implementation improves the CNR, accuracy and cup artifact levels of the reconstructed images, when compared to a cone-beam CT, by reducing its scatter contribution. A 10 ps timing jitter on the measured time of flight leads to an image quality similar to fan-beam CT.


  • Time-of-flight computed tomography - proof of principle

    by Julien Rossignol, Rosana Martinez Turtos, Stefan Gundacker, David Gaudreault, Etiennette Auffray, Paul Lecoq, Yves Berube-Lauziere, Réjean Fontaine

    Computed tomography has greatly improved over the last decade, especially through x-ray dose exposure reduction while maintaining image quality. Herein, a new concept is proposed to improve the contrast-to-noise ratio (CNR) by including the time-of-flight (TOF) information of individual photons to obtain further insight on the photon’s trajectory and to reject scatter contribution. The proof of the concept relies on both simulation and experimental measurements in a cone-beam computed tomography arrangement. Results show a statistical difference between the TOF of scattered and primary photons exploitable in TOF computed tomography. For a large volume of the size of a human abdomen, a scatter reduction from 296% to 4% is achieved in our simulation setup with perfect timing measurements which yields a 110% better CNR, or a dose reduction by a factor of four. Cup artifacts are also reduced from 24.7% to 0.8%, and attenuation inaccuracies are improved from −26.3% to −0.8%. With 100 ps and 10 ps FWHM timing jitters, respectively 75% and 95% of the scatter contribution can be removed with marginal gains below 10 ps. Experimental measurements confirm the feasibility of measuring statistical differences between the TOF of scattered and primary photons.