Kenichi Shimizu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kenichi Shimizu has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Richard G. Compton
Department of Chemistry, Physical and Theoretical Chemistry Laboratory, Oxford University, South Parks Road, Oxford OX1 3QZ, Great Britain
7 shared publications I. Francis Cheng
Department of Chemistry, University of Idaho, Moscow, ID 83844-2343, USA
6 shared publicationsChien M. Wai
Department of Chemistry, University of Idaho, Moscow, ID 83844-2343, USA
5 shared publicationsJoanna S. Wang
Department of Chemistry, University of Idaho, Moscow, Idaho 83844
4 shared publicationsStanislav V. Sokolov
4 shared publications- Andrey Shchukarev
Department of Chemistry, Umeå University 9 , Umeå SE-901 87
3 shared publications
Latest Publications
- 7 March 2018
- Published by Science Trends
Detecting Ultra-Small Plastic Micro-Particles In Water
Small particulates that exist in the environment are produced either naturally within groundwater or through anthropogenic activities. Ultra-small
- 7 March 2018
- Published by Science Trends
Detecting Ultra-Small Plastic Micro-Particles In Water
Small particulates that exist in the environment are produced either naturally within groundwater or through anthropogenic activities. Ultra-small
- 1 December 2017
- Published by Elsevier in Bioelectrochemistry
- Vol. 118, 8-13
Aspects on mediated glucose oxidation at a supported cubic phase
- 1 December 2017
- Published by Elsevier in Bioelectrochemistry
- Vol. 118, 8-13
Aspects on mediated glucose oxidation at a supported cubic phase
- 22 June 2017
- Published by Wiley in Electroanalysis
- Vol. 29 (10) , 2200-2207
In situ Detection of Microplastics: Single Microparticle‐electrode Impacts
Particle‐impact electrochemistry is employed to study spherical polyethylene microparticles suspended in an aqueous solution. This electrochemical method detects polyethylene microparticles impacting on a carbon fiber electrode generating a transient current response or “spike”. We interpret the physio‐chemical origin of the spikes and accurately identify particle size distributions and concentrations for microparticles of sizes 1–10 μm.
- 22 June 2017
- Published by Wiley in Electroanalysis
- Vol. 29 (10) , 2200-2207
In situ Detection of Microplastics: Single Microparticle‐electrode Impacts
Particle‐impact electrochemistry is employed to study spherical polyethylene microparticles suspended in an aqueous solution. This electrochemical method detects polyethylene microparticles impacting on a carbon fiber electrode generating a transient current response or “spike”. We interpret the physio‐chemical origin of the spikes and accurately identify particle size distributions and concentrations for microparticles of sizes 1–10 μm.
- 16 January 2017
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 19 (5) , 3911-3921
Particle-impact analysis of the degree of cluster formation of rutile nanoparticles in aqueous solution
Cluster formation can profoundly influence the bioavailability and (bio)geochemical activity of nanoparticles in natural aquatic systems. While colloidal properties of nanoparticles are commonly investigated using light-scattering techniques, the requirement to dilute samples can affect the fundamental nature and extent of the cluster size. Hence, an alternative in situ approach that can cover a much higher and wider concentration range of particles is desirable. In this study, particle impact chronoamperometry is employed to probe the degree of cluster formation of Alizarin Red S modified rutile nanoparticles of diameter ca. 167 nm in conditions approximating those existing in the environment. Random collisions of individual clusters of the modified rutile particles with a stationary electrode result in transient current signals during a chronoamperometric measurement, indicative of the reduction of the adsorbed Alizarin Red S dye molecules. The results from the particle-impact analysis reveal that the nanoparticles are heavily clustered with an average 91 monomeric particles per cluster. As the spherical equivalent size of the clusters (ca. 754 nm in diameter) is considerably larger than that from nanoparticle tracking analysis (ca. 117 nm), the present work highlights the impact of the dilution on the fundamental nature of the colloidal suspension and introduces the electrochemical determination of the size distribution of inert mineral nanoparticles in highly concentrated media.
- 16 January 2017
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 19 (5) , 3911-3921
Particle-impact analysis of the degree of cluster formation of rutile nanoparticles in aqueous solution
Cluster formation can profoundly influence the bioavailability and (bio)geochemical activity of nanoparticles in natural aquatic systems. While colloidal properties of nanoparticles are commonly investigated using light-scattering techniques, the requirement to dilute samples can affect the fundamental nature and extent of the cluster size. Hence, an alternative in situ approach that can cover a much higher and wider concentration range of particles is desirable. In this study, particle impact chronoamperometry is employed to probe the degree of cluster formation of Alizarin Red S modified rutile nanoparticles of diameter ca. 167 nm in conditions approximating those existing in the environment. Random collisions of individual clusters of the modified rutile particles with a stationary electrode result in transient current signals during a chronoamperometric measurement, indicative of the reduction of the adsorbed Alizarin Red S dye molecules. The results from the particle-impact analysis reveal that the nanoparticles are heavily clustered with an average 91 monomeric particles per cluster. As the spherical equivalent size of the clusters (ca. 754 nm in diameter) is considerably larger than that from nanoparticle tracking analysis (ca. 117 nm), the present work highlights the impact of the dilution on the fundamental nature of the colloidal suspension and introduces the electrochemical determination of the size distribution of inert mineral nanoparticles in highly concentrated media.
- 1 November 2016
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 482, 212-220
Investigation of metal ion interaction with a lipid cubic phase using electrochemical impedance spectroscopy
- 1 November 2016
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 482, 212-220
Investigation of metal ion interaction with a lipid cubic phase using electrochemical impedance spectroscopy
- 6 July 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (19) , 5563-5570
Cysteine determination via adsorptive stripping voltammetry using a bare glassy carbon electrode
The electrochemical determination of cysteine is investigated by adsorptive stripping voltammetric detection of a copper–cysteine complex compound using a bare glassy carbon electrode. In acidic 0.1 M KNO3 solution (pH 4), the electrochemical oxidation of this complex compound generates a characteristic anodic peak ca. −0.17 V vs. a standard mercury/mercurous sulphate reference electrode. The voltammetric response is highly reproducible within 2.1% error (n = 3). A linear dynamic range is obtained for a cysteine concentration of 1.0 μM to 10.0 μM. The sensitivity of 0.18 ± 0.006 μA μM−1 and the limit of detection of 0.03 μM (n = 3) make our methodology highly applicable for practical applications. Successful determination of cysteine concentration in the presence of glutathione has also been demonstrated by the sequential determination of the concentrations of total thiol and the tripeptide alone.
- 6 July 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (19) , 5563-5570
Cysteine determination via adsorptive stripping voltammetry using a bare glassy carbon electrode
The electrochemical determination of cysteine is investigated by adsorptive stripping voltammetric detection of a copper–cysteine complex compound using a bare glassy carbon electrode. In acidic 0.1 M KNO3 solution (pH 4), the electrochemical oxidation of this complex compound generates a characteristic anodic peak ca. −0.17 V vs. a standard mercury/mercurous sulphate reference electrode. The voltammetric response is highly reproducible within 2.1% error (n = 3). A linear dynamic range is obtained for a cysteine concentration of 1.0 μM to 10.0 μM. The sensitivity of 0.18 ± 0.006 μA μM−1 and the limit of detection of 0.03 μM (n = 3) make our methodology highly applicable for practical applications. Successful determination of cysteine concentration in the presence of glutathione has also been demonstrated by the sequential determination of the concentrations of total thiol and the tripeptide alone.
- Open Access
- 1 July 2016
- Published by Elsevier in Colloid and Interface Science Communications
- Vol. 13, 19-22
Agglomeration equilibria of hematite nanoparticles
- 1 July 2016
- Published by Elsevier in Colloid and Interface Science Communications
- Vol. 13, 19-22
Open AccessAgglomeration equilibria of hematite nanoparticles
- 1 April 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (10) , 2904-2910
Voltammetric detection of glutathione: an adsorptive stripping voltammetry approach
A simple, sensitive, and rapid detection of glutathione by cyclic voltammetry using a bare glassy carbon electrode is reported in which glutathione forms a 1 : 1 complex compound with copper(II) ions. This complex compound is adsorbed onto the electrode surface and undergoes electrochemical oxidation at a characteristic oxidation potential of ca. −0.20 V vs. the standard mercury/mercurous sulphate reference electrode, which is used to detect the glutathione concentration. The linear dynamic range is obtained for a glutathione concentration from 1 μM to 12.5 μM, and the sensitivity is found to be 0.1 ± 0.002 μA μM−1. A low limit of detection (n = 3) of 0.14 μM and a precision of 1.8% are achieved using a simple, unmodified electrode. The robustness of the present methodology is demonstrated by the successful quantitative analysis of glutathione in the presence of cysteine.
- 1 April 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (10) , 2904-2910
Voltammetric detection of glutathione: an adsorptive stripping voltammetry approach
A simple, sensitive, and rapid detection of glutathione by cyclic voltammetry using a bare glassy carbon electrode is reported in which glutathione forms a 1 : 1 complex compound with copper(II) ions. This complex compound is adsorbed onto the electrode surface and undergoes electrochemical oxidation at a characteristic oxidation potential of ca. −0.20 V vs. the standard mercury/mercurous sulphate reference electrode, which is used to detect the glutathione concentration. The linear dynamic range is obtained for a glutathione concentration from 1 μM to 12.5 μM, and the sensitivity is found to be 0.1 ± 0.002 μA μM−1. A low limit of detection (n = 3) of 0.14 μM and a precision of 1.8% are achieved using a simple, unmodified electrode. The robustness of the present methodology is demonstrated by the successful quantitative analysis of glutathione in the presence of cysteine.
- 1 March 2016
- Published by Elsevier in Analytica Chimica Acta
- Vol. 914, 1-6
Detection of methotrexate in a flow system using electrochemical impedance spectroscopy and multivariate data analysis
- 1 March 2016
- Published by Elsevier in Analytica Chimica Acta
- Vol. 914, 1-6
Detection of methotrexate in a flow system using electrochemical impedance spectroscopy and multivariate data analysis
- 19 February 2016
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 45 (22) , 9045-9050
Bifluoride ([HF 2 ] − ) formation at the fluoridated aluminium hydroxide/water interface
This study uncovers bifluoride-type (difluorohydrogenate(I); [HF2]−) species formed at mineral/water interfaces. Bifluoride forms at Al–F surface sites resulting from the partial fluoridation of gibbsite (γ-Al(OH3)) and bayerite (α-Al(OH3)) particles exposed to aqueous solutions of 50 mM NaF. Fluoride removal from these solutions is proton-promoted and results in a strongly self-buffered suspensions at circumneutral pH, proceeds at a F : H consumption ratio of 2 : 1, and with recorded losses of up to 17 mM fluoride (58 F nm−2). These loadings exceed crystallographic site densities by a factor of 3–4, yet the reactions have no resolvable impact on particle size, shape and mineralogy. X-ray photoelectron spectroscopy (XPS) of frozen (−155 °C) wet mineral pastes revealed coexisting surface F− and HF0 species. Electron energy loss features pointed to multilayer distribution of these species at the mineral/water interface. XPS also uncovered a distinct form of Na+ involved in binding fluoride-bearing species. XPS and solid state magic angle spinning 19F nuclear magnetic resonance measurements showed that these fluoride species were highly comparable to a sodium-bifluoride (NaHF2) reference. First layer surface species are represented as Al–F–H–F–Al and Al–F–Na–F–Al, and may form multi-layered species into the mineral/water interface. These results consequently point to a potentially overlooked inorganic fluorine species in a technologically relevant mineral/water interfacial systems.
- 19 February 2016
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 45 (22) , 9045-9050
Bifluoride ([HF 2 ] − ) formation at the fluoridated aluminium hydroxide/water interface
This study uncovers bifluoride-type (difluorohydrogenate(I); [HF2]−) species formed at mineral/water interfaces. Bifluoride forms at Al–F surface sites resulting from the partial fluoridation of gibbsite (γ-Al(OH3)) and bayerite (α-Al(OH3)) particles exposed to aqueous solutions of 50 mM NaF. Fluoride removal from these solutions is proton-promoted and results in a strongly self-buffered suspensions at circumneutral pH, proceeds at a F : H consumption ratio of 2 : 1, and with recorded losses of up to 17 mM fluoride (58 F nm−2). These loadings exceed crystallographic site densities by a factor of 3–4, yet the reactions have no resolvable impact on particle size, shape and mineralogy. X-ray photoelectron spectroscopy (XPS) of frozen (−155 °C) wet mineral pastes revealed coexisting surface F− and HF0 species. Electron energy loss features pointed to multilayer distribution of these species at the mineral/water interface. XPS also uncovered a distinct form of Na+ involved in binding fluoride-bearing species. XPS and solid state magic angle spinning 19F nuclear magnetic resonance measurements showed that these fluoride species were highly comparable to a sodium-bifluoride (NaHF2) reference. First layer surface species are represented as Al–F–H–F–Al and Al–F–Na–F–Al, and may form multi-layered species into the mineral/water interface. These results consequently point to a potentially overlooked inorganic fluorine species in a technologically relevant mineral/water interfacial systems.