Sam Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sam Sharma has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Hisashi Hara
Weill Cornell Medicine, New York Presbyterian Hospital, 1300 York Ave, New York, NY, 10065, USA
3 shared publicationsJeffrey Milsom
Weill Cornell Medicine, New York Presbyterian Hospital, 1300 York Ave, New York, NY, 10065, USA
3 shared publicationsKota Momose
Weill Cornell Medicine, New York Presbyterian Hospital, Department of Gasteroenterology, Department of Surgery, 641 Lexington Ave, New York, NY, 10022, USA
3 shared publicationsJames East
Oxford Radcliffe Hospital, Oxford, OX3 9DU, UK
2 shared publicationsKazuki Sumiyama
Jikei University School of Medicine, Tokyo, Japan
2 shared publicationsKiyokazu Nakajima
Osaka University, Osaka, Japan
2 shared publications
Latest Publications
- Open Access
- 8 August 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-16
Thy1 marks a distinct population of slow-cycling stem cells in the mouse epidermis
The presence of distinct stem cells that maintain the interfollicular epidermis is highly debated. Here, we report a population of keratinocytes, marked by Thy1, in the basal layer of the interfollicular epidermis. We find that epidermal cells expressing differential levels of Thy1 display distinct transcriptional signatures. Thy1+ keratinocytes do not express T cell markers, express a unique transcriptional profile, cycle significantly slower than basal epidermal progenitors and display significant expansion potential in vitro. Multicolor lineage tracing analyses and mathematical modeling reveal that Thy1+ basal keratinocytes do not compete neutrally alike interfollicular progenitors and contribute long-term to both epidermal replenishment and wound repair. Importantly, ablation of Thy1+ cells strongly impairs these processes, thus indicating the non-redundant function of Thy1+ stem cells in the epidermis. Collectively, these results reveal a distinct stem cell population that plays a critical role in epidermal homeostasis and repair.
- 8 August 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-16
Open AccessThy1 marks a distinct population of slow-cycling stem cells in the mouse epidermis
The presence of distinct stem cells that maintain the interfollicular epidermis is highly debated. Here, we report a population of keratinocytes, marked by Thy1, in the basal layer of the interfollicular epidermis. We find that epidermal cells expressing differential levels of Thy1 display distinct transcriptional signatures. Thy1+ keratinocytes do not express T cell markers, express a unique transcriptional profile, cycle significantly slower than basal epidermal progenitors and display significant expansion potential in vitro. Multicolor lineage tracing analyses and mathematical modeling reveal that Thy1+ basal keratinocytes do not compete neutrally alike interfollicular progenitors and contribute long-term to both epidermal replenishment and wound repair. Importantly, ablation of Thy1+ cells strongly impairs these processes, thus indicating the non-redundant function of Thy1+ stem cells in the epidermis. Collectively, these results reveal a distinct stem cell population that plays a critical role in epidermal homeostasis and repair.
- 1 July 2019
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 67, 18-23
Endoscopic stabilization device evaluation using IDEAL framework: A quality improvement study
To determine whether clinical evaluation reporting using the IDEAL (Idea, Development, Exploration, Assessment and Long-term study) framework improves a novel double-balloon endoscopic stabilization technology. Observational registry 6 month study with no follow-up. Using the Prospective Development Study (PDS) format recommended by the IDEAL collaboration, we report on continued refinement and optimization of an endoscopic stabilization platform during a clinical study conducted by two clinicians from the first case onwards. Key outcomes (ability to reach cecum, inflation of balloons in the sigmoid and ascending colon, and complications) were prospectively reported for each patient sequentially. All changes to technique were highlighted, showing when they occurred and an explanation for the change. 30 colonoscopies were undertaken using the device from April to September 2017. Two patients were excluded from the analysis for protocol deviations. Cecum was reached in 89% of the per protocol population of patients in an average time of 13.5 ± 11 min. Therapeutic zone creation was successful in 89% of patients on the right side of the intestine and 100% in those that reached the sigmoid. There were five deliberate changes in technique that occurred during the study that enabled improved device technical performance. There were no serious complications and one polyp was removed successfully using the device. Clinicians reported endoscope stability and increased visibility of the intestinal mucosa increased when using the device. The IDEAL framework provided a structured reporting of the changes made to technique. Those changes facilitated a device that is safe, has achieved stability with improved performance.
- 1 July 2019
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 67, 18-23
Endoscopic stabilization device evaluation using IDEAL framework: A quality improvement study
To determine whether clinical evaluation reporting using the IDEAL (Idea, Development, Exploration, Assessment and Long-term study) framework improves a novel double-balloon endoscopic stabilization technology. Observational registry 6 month study with no follow-up. Using the Prospective Development Study (PDS) format recommended by the IDEAL collaboration, we report on continued refinement and optimization of an endoscopic stabilization platform during a clinical study conducted by two clinicians from the first case onwards. Key outcomes (ability to reach cecum, inflation of balloons in the sigmoid and ascending colon, and complications) were prospectively reported for each patient sequentially. All changes to technique were highlighted, showing when they occurred and an explanation for the change. 30 colonoscopies were undertaken using the device from April to September 2017. Two patients were excluded from the analysis for protocol deviations. Cecum was reached in 89% of the per protocol population of patients in an average time of 13.5 ± 11 min. Therapeutic zone creation was successful in 89% of patients on the right side of the intestine and 100% in those that reached the sigmoid. There were five deliberate changes in technique that occurred during the study that enabled improved device technical performance. There were no serious complications and one polyp was removed successfully using the device. Clinicians reported endoscope stability and increased visibility of the intestinal mucosa increased when using the device. The IDEAL framework provided a structured reporting of the changes made to technique. Those changes facilitated a device that is safe, has achieved stability with improved performance.
- Open Access
- 24 January 2019
- Published by Springer Nature in Surgical Endoscopy
- Vol. 33 (3) , 992
Correction to: Facilitating endoscopic submucosal dissection: double balloon endolumenal platform significantly improves dissection time compared with conventional technique (with video)
Gerd Silberhumer’s name was misspelled in the original publication; it is correct as displayed here.
- 24 January 2019
- Published by Springer Nature in Surgical Endoscopy
- Vol. 33 (3) , 992
Open AccessCorrection to: Facilitating endoscopic submucosal dissection: double balloon endolumenal platform significantly improves dissection time compared with conventional technique (with video)
Gerd Silberhumer’s name was misspelled in the original publication; it is correct as displayed here.
- Open Access
- 16 July 2018
- Published by Springer Nature in Surgical Endoscopy
- Vol. 33 (1) , 315-321
Facilitating endoscopic submucosal dissection: double balloon endolumenal platform significantly improves dissection time compared with conventional technique (with video)
Background Flexible endoscopes ability to manipulate the intestinal environment is limited. As a result, complex endolumenal procedures are often technically demanding and result in long procedure times, impacting institutional resources. Single- and double-balloon add-on endoscopic devices have been employed throughout the GI tract to facilitate tissue control e.g., small bowel enteroscopy, with recent reports suggesting a possible colonic utility for complex procedures e.g., ESD. Our objective was to objectively analyze the efficacy of a new double-balloon device in performing ESD. Methods Ex vivo—12 simulated colonic lesions were created in porcine rectum using a standard 40 mm diameter template. Two categories were evaluated, standard cap technique ESD and double-balloon assisted ESD with retraction (ESD-R). Cases were performed sequentially. In vivo—Six, 40 mm lesion ESD-R’s were performed in a porcine model. The primary outcomes of this study were total procedure and dissection times. Results In ex vivo studies, the median total procedure time with the double-balloon platform was significantly shorter than the traditional ESD technique (29 ± 18 vs. 57 ± 21 min, p = 0.03). In the in vivo studies, lesions were successfully removed in a mean time of 48 min, with a dissection time of 20 min with no significant complications. Balloon-clip retraction and specimen retrieval capabilities were used in all double-balloon assisted cases. After 6 cases, times were significantly shorter (ex vivo 47 vs. 17 min; in vivo 57 vs. 27 min). Conclusions We have demonstrated the development of a unique technical ESD method facilitated by a new double-balloon device. Ex and in vivo investigation demonstrated superiority of ESD-R over the conventional ex vivo method. The DB device provided increased stability, improved visualization and tissue traction, which significantly reduced dissection time. Such an approach may increase safety, improve patient outcomes, and may prevent unnecessary surgeries for benign conditions.
- 16 July 2018
- Published by Springer Nature in Surgical Endoscopy
- Vol. 33 (1) , 315-321
Open AccessFacilitating endoscopic submucosal dissection: double balloon endolumenal platform significantly improves dissection time compared with conventional technique (with video)
Background Flexible endoscopes ability to manipulate the intestinal environment is limited. As a result, complex endolumenal procedures are often technically demanding and result in long procedure times, impacting institutional resources. Single- and double-balloon add-on endoscopic devices have been employed throughout the GI tract to facilitate tissue control e.g., small bowel enteroscopy, with recent reports suggesting a possible colonic utility for complex procedures e.g., ESD. Our objective was to objectively analyze the efficacy of a new double-balloon device in performing ESD. Methods Ex vivo—12 simulated colonic lesions were created in porcine rectum using a standard 40 mm diameter template. Two categories were evaluated, standard cap technique ESD and double-balloon assisted ESD with retraction (ESD-R). Cases were performed sequentially. In vivo—Six, 40 mm lesion ESD-R’s were performed in a porcine model. The primary outcomes of this study were total procedure and dissection times. Results In ex vivo studies, the median total procedure time with the double-balloon platform was significantly shorter than the traditional ESD technique (29 ± 18 vs. 57 ± 21 min, p = 0.03). In the in vivo studies, lesions were successfully removed in a mean time of 48 min, with a dissection time of 20 min with no significant complications. Balloon-clip retraction and specimen retrieval capabilities were used in all double-balloon assisted cases. After 6 cases, times were significantly shorter (ex vivo 47 vs. 17 min; in vivo 57 vs. 27 min). Conclusions We have demonstrated the development of a unique technical ESD method facilitated by a new double-balloon device. Ex and in vivo investigation demonstrated superiority of ESD-R over the conventional ex vivo method. The DB device provided increased stability, improved visualization and tissue traction, which significantly reduced dissection time. Such an approach may increase safety, improve patient outcomes, and may prevent unnecessary surgeries for benign conditions.
- 1 May 2017
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 85 (5) , AB515
Mo2000 Double Balloon Assisted Colonic Esd: Straight Versus Right-Sided Outcomes
- 1 May 2017
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 85 (5) , AB515
Mo2000 Double Balloon Assisted Colonic Esd: Straight Versus Right-Sided Outcomes
- 1 January 2015
- Published by Springer Nature
- p. 49-59
Teaching Basic Laparoscopic Skills
- 27 November 2013
- Published by Taylor & Francis in Colorectal Cancer
- Vol. 2 (6) , 479-482
Can endoscopy and laparoscopy be combined to remove complex polyps?
- 27 November 2013
- Published by Taylor & Francis in Colorectal Cancer
- Vol. 2 (6) , 479-482
Can endoscopy and laparoscopy be combined to remove complex polyps?