CBChristine Brophy

Christine Brophy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christine Brophy has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Preparation and certification of novel high-protein food certified reference materials

    by Kelly L. LeBlanc, Kenny Nadeau, Lu Yang, Christine Brophy, Indumathi Pihillagawa Gedara, Calvin Palmer, Juris Meija, Zoltán Mester, Patricia Grinberg

    In response to the growing market for alternative high-protein foods, the National Research Council of Canada (NRC) has produced a series of five new certified reference materials (CRMs) including insect-based (black soldier fly larvae, cricket flour, and mealworm powder; BFLY-1, KRIK-1, and VORM-1) and plant-based proteins (canola meal and seaweed powder; CAME-1 and GSEA-1), in addition to the newest iteration of the fish protein CRM, DORM-5. Data for the mass fractions of up to 33 trace and essential elements were obtained for each material, along with speciation data for arsenic and selenium. Values for each analyte are presented on the materials’ Certificates of Analysis, on a dry mass basis, and include estimates of their expanded uncertainties corresponding to 95% confidence (k = 2). Herein, we describe the methods involved in the characterization campaigns for these materials, including the steps taken to overcome associated analytical challenges. We also describe a new approach to consensus value determination, via bias correction of measured results based on the quality control measurement of several similar-matrix CRMs, followed by the use of the Laplace random effects model for data combination. Graphical abstract

  • Open Access

    Production and certification of ORMS-6, a certified reference material for mercury in water

    by Kelly L. LeBlanc, Kenny Nadeau, Indumathi Pihillagawa Gedara, Calvin Palmer, Christine Brophy, Lu Yang, Patricia Grinberg

    Mercury is recognized by the World Health Organization as one of the “top ten chemicals of major public health concern.” To support global efforts in monitoring mercury contamination in drinking and environmental waters, analytical methods have continuously improved to achieve greater accuracy and lower detection limits. Critical tools in support of this endeavor are fit-for-purpose Certified Reference Materials (CRMs) with well-characterized mercury content present at trace or ultra-trace levels. The National Research Council of Canada (NRC) has produced and maintained such CRMs for several decades. This study presents the production and certification of the latest iteration, ORMS-6, mercury in water. This process involved rigorous cleaning protocols to mitigate background mercury contamination and real-time monitoring during ampouling to ensure that the material’s mercury content remained stable throughout the day-long process. The final consensus value for mercury content in ORMS-6 was determined by a combination of two independent methods: isotope dilution cold-vapor inductively coupled mass spectrometry and cold-vapor atomic fluorescence spectrometry.

  • UV photochemical generation of volatile cadmium species

    by Joaquim A. Nóbrega, Ralph E. Sturgeon, Patricia Grinberg, Graeme J. Gardner, Christine S. Brophy, Edivaldo E. Garcia

    Photochemical generation of a volatile molecular Cd species from an acetic acid medium was accomplished using a thin film generator comprising a 20 W low pressure UV source. Argon gas was used to sweep the product vapor to a quartz tube atomizer heated to 900 °C. No signal was generated below about 770 °C and optimum atomization conditions required addition of 10% hydrogen to the Ar transfer gas, indicative of a thermochemical atomization process similar to that undergone for metal hydrides. UV generation efficiency exceeded 90% but the transfer of the analyte to the detector was problematic and precision of measurement was near 30% RSD. Despite such conditions, an estimated limit of detection was 2 μg l−1.


  • Versatile Thin-Film Reactor for Photochemical Vapor Generation

    by Chengbin Zheng, Ralph E. Sturgeon, Christine Brophy, Xiandeng Hou

    A novel thin-film reactor is described and evaluated for its analytical performance with photochemical vapor generation (TF-PVG). The device, comprising both the generator and a gas−liquid separator, utilizes a vertical central quartz rod onto which the sample is pumped to yield a thin liquid film conducive to the rapid escape of generated hydrophobic species. The rod is housed within a concentric quartz tube through which a flow of argon carrier/stripping gas is passed to remove and transport the generated species to a detector, which in this study is an inductively coupled argon plasma optical emission spectrometer (ICP-OES). The concentric quartz tube is itself surrounded by a 78-turn 0.5 m long quartz coil low-pressure mercury discharge lamp operating at 20 W. The performance of this thin-film photoreactor was evaluated through comparison of analytical figures of merit for detection of a number of elements undergoing PVG in the presence of formic or acetic acid with those arising from conventional solution nebulization under optimized conditions. The TF-PVG reactor provided sensitivity enhancements, of 110-, 120-, 130-, 250-, 120-, 230-, 78-, 1.3-, 16-, and 32-fold for As, Sb, Bi, Se, Te, Hg, Ni, Co, Fe, and I, respectively, and detection limit enhancements of 110-, 140-, 170-, 270-, 200-, 300-, 160-, 2.7-, 50-, and 44-fold for these same elements. Vapor generation efficiencies ranged from 20−100% for this suite of analytes. The utility of this technique was demonstrated by the determination of Fe and Ni in Certified Reference Materials DORM-3 (fish protein) and DOLT-4 (dogfish liver tissue).


  • High-Yield UV-Photochemical Vapor Generation of Iron for Sample Introduction with Inductively Coupled Plasma Optical Emission Spectrometry

    by Chengbin Zheng, Ralph E. Sturgeon, Christine S. Brophy, Shaopan He, Xiandeng Hou

    A novel approach to the generation of volatile iron compounds (likely the pentacarbonyl) with high efficiency is described, wherein solutions containing either Fe2+ or Fe3+ and low molecular weight organic acids such as formic, acetic or propionic are exposed to a UV source. An optimum generation efficiency of 60 ± 2% was achieved in 50% formic acid at pH 2.5 with an irradiation time of 250 s by use of a 17 W low-pressure mercury grid lamp. Compared to conventional solution nebulization, sensitivity and limit of detection were improved 80- and 100-fold, respectively, at the 238.204 nm Fe II emission line. A precision of 0.75% RSD was achieved at a concentration of 100 ng/mL. Photochemical vapor generation sample introduction was used for the determination of trace iron in several environmental Certified Reference Materials, including National Research Council Canada DORM-3 fish muscle tissue, DOLT-3 and DOLT-4 fish liver tissues, and SLRS-5 river water, providing analytical results in excellent agreement with certified values based on a simple external calibration.