Wellington Maycon Santos Bernardes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wellington Maycon Santos Bernardes has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Nobuhiro Asada
University of São Paulo
7 shared publications - Filipe Saraiva
Federal University of Para
3 shared publications - Fillipe Matos de Vasconcelos
Department of Electrical Engineering, Federal University of Mato Grosso, Avenida Fernando Correa da Costa, 1367, Cuiaba 78060-900, Brazil
3 shared publications Ana P. Mazzini
Department of Electrical and Computer Engineering, São Carlos School of Engineering - USP São Carlos, Brazil
2 shared publications- Antonio Eduardo Ceolin Momesso
Electrical Engineering Department, Faculty of Architecture, Engineering and Technology, Federal University of Mato Grosso, Cuiabá 78060-900, Brazil
2 shared publications - Arthur Gomes de Souza
Laboratory of Alternative Energies and Power System Protection Faculty of Electrical Engineering Federal University of Uberlândia Uberlândia Minas Gerais Brazil
2 shared publications
Latest Publications
- Open Access
- 8 October 2026
- Published by Institution of Engineering and Technology (IET) in Vector: The Journal of Engineering
- Vol. 2027 (1)
Penalty‐Based Discrete Particle Swarm Optimization for Coordinating Relays in a Brazilian 138 kV Real Power System
In this paper, an original approach to deal with the coordination of instantaneous and time‐overcurrent directional protection is proposed. Such problem is mathematically modelled as a nonlinear programming problem with continuous and discrete variables, whose proposed resolution approach is based on the minimization of the relays' operation time by using penalty‐based discrete particle swarm optimization. In this new technique, discrete variables are treated as continuous by using sinusoidal, quadratic or polynomial functions and inequality constraints are transformed into equality constraints. The effectiveness of the model and the robustness of this approach for coordinating directional overcurrent relays were verified with a Brazilian 138 kV real power system, considering both electromechanical and digital relays, mutual impedances and network contingencies. The method has shown success in handling discrete variables and inequality constraints, which results in the decreasing of the protection engineer's workload.
- 8 October 2026
- Published by Institution of Engineering and Technology (IET) in Vector: The Journal of Engineering
- Vol. 2027 (1)
Open AccessPenalty‐Based Discrete Particle Swarm Optimization for Coordinating Relays in a Brazilian 138 kV Real Power System
In this paper, an original approach to deal with the coordination of instantaneous and time‐overcurrent directional protection is proposed. Such problem is mathematically modelled as a nonlinear programming problem with continuous and discrete variables, whose proposed resolution approach is based on the minimization of the relays' operation time by using penalty‐based discrete particle swarm optimization. In this new technique, discrete variables are treated as continuous by using sinusoidal, quadratic or polynomial functions and inequality constraints are transformed into equality constraints. The effectiveness of the model and the robustness of this approach for coordinating directional overcurrent relays were verified with a Brazilian 138 kV real power system, considering both electromechanical and digital relays, mutual impedances and network contingencies. The method has shown success in handling discrete variables and inequality constraints, which results in the decreasing of the protection engineer's workload.
- Open Access
- 7 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 2377-2391
Attribution of Responsibility for Short-Duration Voltage Variations in Power Distribution Systems via QGIS, OpenDSS, and Python Language
Short-Duration Voltage Variations (SDVVs) are phenomena that significantly impact power quality. Although they typically last no longer than three minutes, such events can disrupt load operations and cause substantial production losses. This study presents an enhanced methodology for determining whether an SDVV event originates upstream or downstream of the point of common coupling between two agents interconnected through a transformer. Building upon the work of Ferreira et al., whose original approach was applied to a circuit using MATLAB/Simulink, this research advances the methodology by applying it to both real and benchmark distribution systems using open-source tools, namely QGIS, OpenDSS, and Python™. The well-known IEEE 34-Bus Test System has been used to verify the methodology’s generalizability. The method was also further validated through tests conducted on two actual Brazilian distribution feeders in Uberlândia, Minas Gerais: one supplying large industrial consumers such as a rice mill and a carbonated beverages factory, and the other serving a municipal wastewater treatment plant and a large photovoltaic plant. By using real, detailed and georeferenced data, the approach ensures an accurate representation of both the network topology and the installed equipment. The results confirm that the proposed methodology reliably identifies the origin of SDVV events. A key contribution of this study is that the attribution of responsibility remains robust regardless of variations in transformer winding configurations, fault resistance, circuit topology, load characteristics, or the presence of distributed generation. These findings demonstrate the accessibility, robustness and practical applicability, offering a valuable tool for utilities and researchers aiming to enhance power quality and accountability in distribution networks.
- 7 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 2377-2391
Open AccessAttribution of Responsibility for Short-Duration Voltage Variations in Power Distribution Systems via QGIS, OpenDSS, and Python Language
Short-Duration Voltage Variations (SDVVs) are phenomena that significantly impact power quality. Although they typically last no longer than three minutes, such events can disrupt load operations and cause substantial production losses. This study presents an enhanced methodology for determining whether an SDVV event originates upstream or downstream of the point of common coupling between two agents interconnected through a transformer. Building upon the work of Ferreira et al., whose original approach was applied to a circuit using MATLAB/Simulink, this research advances the methodology by applying it to both real and benchmark distribution systems using open-source tools, namely QGIS, OpenDSS, and Python™. The well-known IEEE 34-Bus Test System has been used to verify the methodology’s generalizability. The method was also further validated through tests conducted on two actual Brazilian distribution feeders in Uberlândia, Minas Gerais: one supplying large industrial consumers such as a rice mill and a carbonated beverages factory, and the other serving a municipal wastewater treatment plant and a large photovoltaic plant. By using real, detailed and georeferenced data, the approach ensures an accurate representation of both the network topology and the installed equipment. The results confirm that the proposed methodology reliably identifies the origin of SDVV events. A key contribution of this study is that the attribution of responsibility remains robust regardless of variations in transformer winding configurations, fault resistance, circuit topology, load characteristics, or the presence of distributed generation. These findings demonstrate the accessibility, robustness and practical applicability, offering a valuable tool for utilities and researchers aiming to enhance power quality and accountability in distribution networks.
- Open Access
- 1 January 2019
- Published by Galoa Events Proceedings
Forecasting Electric Power Generation of Grid-Connected Solar Photovoltaic Systems by Using Artificial Neural Networks
- 1 January 2019
- Published by Galoa Events Proceedings
Open AccessForecasting Electric Power Generation of Grid-Connected Solar Photovoltaic Systems by Using Artificial Neural Networks
- 12 December 2018
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 51 (28) , 315-320
Fuzzy-based Non-communicating Adaptive Overcurrent Relay
- 12 December 2018
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 51 (28) , 315-320
Fuzzy-based Non-communicating Adaptive Overcurrent Relay
- 1 February 2017
- Published by Elsevier in Electric Power Systems Research
- Vol. 143, 400-408
Setting directional overcurrent protection parameters using hybrid GA optimizer
- 1 February 2017
- Published by Elsevier in Electric Power Systems Research
- Vol. 143, 400-408
Setting directional overcurrent protection parameters using hybrid GA optimizer
- 1 December 2015
- Published by Elsevier in Neurocomputing
- Vol. 170, 328-338
A framework for classification of non-linear loads in smart grids using Artificial Neural Networks and Multi-Agent Systems
- 1 December 2015
- Published by Elsevier in Neurocomputing
- Vol. 170, 328-338
A framework for classification of non-linear loads in smart grids using Artificial Neural Networks and Multi-Agent Systems
- 19 November 2015
- Published by Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais
Algoritmo enxame de partículas discreto para coordenação de relés direcionais de sobrecorrente em sistemas elétricos de potência
Este trabalho propõe uma metodologia baseada em técnicas inteligentes capaz de fornecer uma coordenação otimizada de relés direcionais de sobrecorrente instalados em sistemas de energia elétrica. O problema...
- 19 November 2015
- Published by Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais
Algoritmo enxame de partículas discreto para coordenação de relés direcionais de sobrecorrente em sistemas elétricos de potência
Este trabalho propõe uma metodologia baseada em técnicas inteligentes capaz de fornecer uma coordenação otimizada de relés direcionais de sobrecorrente instalados em sistemas de energia elétrica. O problema...
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Topological processing of mutually coupled circuits for directional overcurrent protection
Well planned and adjusted protection devices increase the reliability of the system against fault events. The directional overcurrent relays, for example, play an important role in the protection of meshed transmission systems. They are usually employed as backup protection of distance relays. However, even as backup protection, the correct coordination can be set to speed up the fault mitigation and to minimize the affected areas. The requirement for setting the directional overcurrent relays is the knowledge of the short circuit currents under specific conditions. The presence of mutually coupled lines may cause significant impact on the short circuit calculation, thus affecting the currents for which the protection devices have been adjusted to. In many cases, the coupled lines are formed by sections and only some parts of the transmission lines are under direct influence of those effects. Even so, it is important to perform a topological processing to identify the real extension of the lines for the correct calculation of the currents related to mutual impedance. This paper shows the effect of the mutual coupling on the calculation of currents for different operating conditions and the the topological processing to provide the correct results.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Topological processing of mutually coupled circuits for directional overcurrent protection
Well planned and adjusted protection devices increase the reliability of the system against fault events. The directional overcurrent relays, for example, play an important role in the protection of meshed transmission systems. They are usually employed as backup protection of distance relays. However, even as backup protection, the correct coordination can be set to speed up the fault mitigation and to minimize the affected areas. The requirement for setting the directional overcurrent relays is the knowledge of the short circuit currents under specific conditions. The presence of mutually coupled lines may cause significant impact on the short circuit calculation, thus affecting the currents for which the protection devices have been adjusted to. In many cases, the coupled lines are formed by sections and only some parts of the transmission lines are under direct influence of those effects. Even so, it is important to perform a topological processing to identify the real extension of the lines for the correct calculation of the currents related to mutual impedance. This paper shows the effect of the mutual coupling on the calculation of currents for different operating conditions and the the topological processing to provide the correct results.