Fillipe Matos de Vasconcelos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fillipe Matos de Vasconcelos has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Wellington Maycon Santos Bernardes
Laboratory of Alternative Energies and Power System Protection Faculty of Electrical Engineering Federal University of Uberlândia Uberlândia Minas Gerais Brazil
3 shared publications Ana P. Mazzini
Department of Electrical and Computer Engineering, São Carlos School of Engineering - USP São Carlos, Brazil
2 shared publications- Carolina Gonçalves Pardini
Department of Electrical Engineering, Federal University of Mato Grosso, Avenida Fernando Correa da Costa, 1367, Cuiaba 78060-900, Brazil
2 shared publications - Filipe Saraiva
Federal University of Para
2 shared publications - Leandro Tolomeu Marques
Departamento de Engenharia Elétrica, Universidade Federal de Mato Grosso, Cuiabá - MT
2 shared publications - Artur Felipe Da Silva Veloso
Department of Computing, Federal University of Piauí (UFPI), Teresina 64049-550, PI, Brazil
1 shared publication
Latest Publications
- Open Access
- 14 November 2025
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 16 (11) , 621
Impact Assessment of Electric Bus Charging on a Real-Life Distribution Feeder Using GIS-Integrated Power Utility Data: A Case Study in Brazil
The electrification of public transport with battery electric buses (BEBs) poses technical, regulatory, and environmental challenges. This paper analyzes the impact of BEB charging on a Brazilian urban medium-voltage (MV) feeder using a novel methodology to convert utility GIS data into OpenDSS simulation models. The study utilizes Geographic Database of the Distribution Company (BDGD) data from the Brazilian Electricity Regulatory Agency (ANEEL) and OpenDSS simulations. Motivated by Cuiabá’s proposal to electrify its public bus fleet, four realistic scenarios were simulated, incorporating distributed photovoltaic (PV) generation and vehicle-to-grid (V2G) operation. Results show that up to 118 BEBs can be charged simultaneously without voltage violations. However, thermal overload occurs beyond 56 units, requiring conductor upgrades or load redistribution. PV systems can supply up to 64% of the daily energy demand but introduce reverse power flows and overvoltages, indicating the need for dynamic control. V2G operation enables peak shaving but also leads to overvoltages when more than 33 buses inject power concurrently. The findings suggest that while the current infrastructure partially supports fleet electrification, future scalability depends on integrating smart grid features and reinforcing the system. Although focused on Cuiabá, the methodology offers a replicable approach for low-carbon urban mobility planning in similar developing regions.
- 14 November 2025
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 16 (11) , 621
Open AccessImpact Assessment of Electric Bus Charging on a Real-Life Distribution Feeder Using GIS-Integrated Power Utility Data: A Case Study in Brazil
The electrification of public transport with battery electric buses (BEBs) poses technical, regulatory, and environmental challenges. This paper analyzes the impact of BEB charging on a Brazilian urban medium-voltage (MV) feeder using a novel methodology to convert utility GIS data into OpenDSS simulation models. The study utilizes Geographic Database of the Distribution Company (BDGD) data from the Brazilian Electricity Regulatory Agency (ANEEL) and OpenDSS simulations. Motivated by Cuiabá’s proposal to electrify its public bus fleet, four realistic scenarios were simulated, incorporating distributed photovoltaic (PV) generation and vehicle-to-grid (V2G) operation. Results show that up to 118 BEBs can be charged simultaneously without voltage violations. However, thermal overload occurs beyond 56 units, requiring conductor upgrades or load redistribution. PV systems can supply up to 64% of the daily energy demand but introduce reverse power flows and overvoltages, indicating the need for dynamic control. V2G operation enables peak shaving but also leads to overvoltages when more than 33 buses inject power concurrently. The findings suggest that while the current infrastructure partially supports fleet electrification, future scalability depends on integrating smart grid features and reinforcing the system. Although focused on Cuiabá, the methodology offers a replicable approach for low-carbon urban mobility planning in similar developing regions.
- Open Access
- 18 August 2025
- Published by Universidade Federal de Mato Grosso in E&S Engineering and Science
- Vol. 14 (2) , 1-16
Análise comparativa da viabilidade técnica e econômica entre SIGFI e a rede de distribuição aérea para atendimento de regiões remotas em Barão de Melgaço – Mato Grosso
O acesso à energia elétrica é essencial para o bem-estar e o desenvolvimento social. No entanto, diversas comunidades do Pantanal Mato-grossense ainda vivem em áreas remotas e de difícil acesso, marcadas por cheias e secas sazonais que dificultam a expansão e manutenção da rede elétrica convencional. Este artigo realiza uma análise comparativa da viabilidade técnica e econômica entre a instalação de Sistemas Individuais de Geração de Energia Elétrica com Fonte Intermitente (SIGFI) e a extensão da rede elétrica para atendimento a essas localidades, com foco na região de Barão de Melgaço, no estado de Mato Grosso. Os resultados deste estudo demonstram que o SIGFI apresenta vantagens significativas para comunidades remotas do Pantanal mato-grossense. A análise econômica revela que o sistema fotovoltaico isolado pode ser até 44% mais econômico que a extensão da rede aérea, considerando custos totais de implantação e manutenção em um horizonte de 10 anos. Além disso, o SIGFI mostrou maior confiabilidade, com Duração Equivalente de Interrupção por Unidade Consumidora (DEC) próximo a zero, contra 94 horas da rede convencional no alimentador analisado. Do ponto de vista ambiental, a solução descentralizada evitou a emissão estimada de 12 toneladas de CO₂eq/ano para os 61 consumidores estudados, contribuindo para a sustentabilidade local. Conclui-se que, para regiões com características similares às de Barão de Melgaço marcadas por dificuldades de acesso, sazonalidade de cheias e baixa densidade populacional, o SIGFI representa a solução mais viável técnica e economicamente. Os achados reforçam a importância de políticas públicas adaptadas às realidades regionais e sugerem que a combinação de sistemas fotovoltaicos individuais com microrredes comunitárias pode ser o caminho mais eficiente para a universalização energética em áreas remotas do Brasil.
- 18 August 2025
- Published by Universidade Federal de Mato Grosso in E&S Engineering and Science
- Vol. 14 (2) , 1-16
Open AccessAnálise comparativa da viabilidade técnica e econômica entre SIGFI e a rede de distribuição aérea para atendimento de regiões remotas em Barão de Melgaço – Mato Grosso
O acesso à energia elétrica é essencial para o bem-estar e o desenvolvimento social. No entanto, diversas comunidades do Pantanal Mato-grossense ainda vivem em áreas remotas e de difícil acesso, marcadas por cheias e secas sazonais que dificultam a expansão e manutenção da rede elétrica convencional. Este artigo realiza uma análise comparativa da viabilidade técnica e econômica entre a instalação de Sistemas Individuais de Geração de Energia Elétrica com Fonte Intermitente (SIGFI) e a extensão da rede elétrica para atendimento a essas localidades, com foco na região de Barão de Melgaço, no estado de Mato Grosso. Os resultados deste estudo demonstram que o SIGFI apresenta vantagens significativas para comunidades remotas do Pantanal mato-grossense. A análise econômica revela que o sistema fotovoltaico isolado pode ser até 44% mais econômico que a extensão da rede aérea, considerando custos totais de implantação e manutenção em um horizonte de 10 anos. Além disso, o SIGFI mostrou maior confiabilidade, com Duração Equivalente de Interrupção por Unidade Consumidora (DEC) próximo a zero, contra 94 horas da rede convencional no alimentador analisado. Do ponto de vista ambiental, a solução descentralizada evitou a emissão estimada de 12 toneladas de CO₂eq/ano para os 61 consumidores estudados, contribuindo para a sustentabilidade local. Conclui-se que, para regiões com características similares às de Barão de Melgaço marcadas por dificuldades de acesso, sazonalidade de cheias e baixa densidade populacional, o SIGFI representa a solução mais viável técnica e economicamente. Os achados reforçam a importância de políticas públicas adaptadas às realidades regionais e sugerem que a combinação de sistemas fotovoltaicos individuais com microrredes comunitárias pode ser o caminho mais eficiente para a universalização energética em áreas remotas do Brasil.
- Open Access
- 4 May 2025
- Published by Universidade Federal de Mato Grosso in E&S Engineering and Science
- Vol. 14 (1) , 20-34
Avaliação da Estabilidade de Tensão Utilizando o Índice |D’| e Redes Neurais Artificiais sob Contingências
Approaches using Artificial Neural Networks (ANNs) have aimed to enhance the accuracy and reliability of voltage stability index calculations to ensure the secure operation of Power Systems (PS), especially under conditions of imminent voltage collapse. Furthermore, complementary research has incorporated the dynamic modeling of transformers and renewable energy sources, while also leveraging real-time phasor measurements to enhance these methodologies. Despite significant advancements, there is still a need to improve the accuracy and computational efficiency of existing indices, particularly in multiple contingency scenarios. This paper proposes the use of the |D’| index, derived from the Power Flow Jacobian matrix, to enhance the precision of voltage stability assessment. The proposed method is evaluated through simulations considering three types of contingencies: stepwise increase in active and reactive power at loads, continuation power flow analysis, and transmission line outages. Performance tests of the |D’| index, using ANNs, demonstrate high accuracy and strong generalization, with low mean absolute errors and standard deviation values, enabling the efficient identification of the most critical buses in the system with low computational cost. The proposed method proved to be effective in reducing errors and variance during testing and validation, particularly under operating conditions close to voltage collapse, highlighting its robustness and efficiency in real-time stability analysis.
- 4 May 2025
- Published by Universidade Federal de Mato Grosso in E&S Engineering and Science
- Vol. 14 (1) , 20-34
Open AccessAvaliação da Estabilidade de Tensão Utilizando o Índice |D’| e Redes Neurais Artificiais sob Contingências
Approaches using Artificial Neural Networks (ANNs) have aimed to enhance the accuracy and reliability of voltage stability index calculations to ensure the secure operation of Power Systems (PS), especially under conditions of imminent voltage collapse. Furthermore, complementary research has incorporated the dynamic modeling of transformers and renewable energy sources, while also leveraging real-time phasor measurements to enhance these methodologies. Despite significant advancements, there is still a need to improve the accuracy and computational efficiency of existing indices, particularly in multiple contingency scenarios. This paper proposes the use of the |D’| index, derived from the Power Flow Jacobian matrix, to enhance the precision of voltage stability assessment. The proposed method is evaluated through simulations considering three types of contingencies: stepwise increase in active and reactive power at loads, continuation power flow analysis, and transmission line outages. Performance tests of the |D’| index, using ANNs, demonstrate high accuracy and strong generalization, with low mean absolute errors and standard deviation values, enabling the efficient identification of the most critical buses in the system with low computational cost. The proposed method proved to be effective in reducing errors and variance during testing and validation, particularly under operating conditions close to voltage collapse, highlighting its robustness and efficiency in real-time stability analysis.
- Open Access
- 20 May 2024
- Published by Association for Computing Machinery (ACM)
- p. 1-8
Deep Clustering Algorithm for Load Profile Business Intelligence Dashboard for Consumer and Utility Management
Context: The implementation and optimization of a Smart Grid (SG), incorporating Smart Meters (SMs) for the collection of energy consumption data, generation and grouping of Load Profiles (LPs), and the use of Business Intelligence (BI) tools for data analysis and visualization, offer significant opportunities for energy efficiency and the management of energy consumption. However, challenges related to non-data-driven decision-making are still prevalent. Problem: Difficulties in efficient energy management and uninformed decision-making are identified, impacting on the efficiency and quality of the electricity supply, as well as the costs for the end consumer. Proposed Solution: This work focused on the implementation of BI dashboards for both the utility and end consumers. It used detailed data and LPs grouped by deep clustering algorithms based on time series, with a view to strategic data analysis and visualization. IS Theory: Integrating SMs, LP analysis, and BI tools strategically informs energy management and decision-making for both the supply company and consumers.Method: Time series techniques were used to generate LPs and clustering algorithms to group them. BI dashboards were implemented, providing detailed views for consumers and the EPC. Results: The results showed empowerment for informed and integrated decision-making, cost savings, environmental contributions and a significant increase in energy efficiency. Contributions and Impact on IS: This work has contributed to efficient energy management, the integration of advanced data analysis techniques and the development of customized BI dashboards. The study demonstrated a positive impact on energy sustainability, offering a basis for the effective integration of SMs, LP analysis and BI tools in energy management.
- 20 May 2024
- Published by Association for Computing Machinery (ACM)
- p. 1-8
Open AccessDeep Clustering Algorithm for Load Profile Business Intelligence Dashboard for Consumer and Utility Management
Context: The implementation and optimization of a Smart Grid (SG), incorporating Smart Meters (SMs) for the collection of energy consumption data, generation and grouping of Load Profiles (LPs), and the use of Business Intelligence (BI) tools for data analysis and visualization, offer significant opportunities for energy efficiency and the management of energy consumption. However, challenges related to non-data-driven decision-making are still prevalent. Problem: Difficulties in efficient energy management and uninformed decision-making are identified, impacting on the efficiency and quality of the electricity supply, as well as the costs for the end consumer. Proposed Solution: This work focused on the implementation of BI dashboards for both the utility and end consumers. It used detailed data and LPs grouped by deep clustering algorithms based on time series, with a view to strategic data analysis and visualization. IS Theory: Integrating SMs, LP analysis, and BI tools strategically informs energy management and decision-making for both the supply company and consumers.Method: Time series techniques were used to generate LPs and clustering algorithms to group them. BI dashboards were implemented, providing detailed views for consumers and the EPC. Results: The results showed empowerment for informed and integrated decision-making, cost savings, environmental contributions and a significant increase in energy efficiency. Contributions and Impact on IS: This work has contributed to efficient energy management, the integration of advanced data analysis techniques and the development of customized BI dashboards. The study demonstrated a positive impact on energy sustainability, offering a basis for the effective integration of SMs, LP analysis and BI tools in energy management.
- Open Access
- 18 October 2023
- Published by SWGE Sistemas Ltda in Anais Do Vi Simpósio Brasileiro de Sistemas Elétricos
- Vol. 1 (2)
Uma Avaliação em Série-Temporal Quase-Estática da Capacidade de Hospedagem de Geração FV em Redes de Distribuição
The increasing penetration of photovoltaic (PV) generation in Brazilian distribution networks has brought a set of operational, safety, and compliance challenges. In this scenario, maximum hosting capacity (MHC) assessment studies are necessary to evaluate the impacts of these systems on the operational states of electrical networks. Currently, there is a growing interest in this topic in the scientific literature, however, given the complexities and intermittencies involved, the subject still lacks lessons learned and definitions of best practices. This article aims to evaluate MHC in distribution networks through quasi-static time-series simulations and heuristic methods, so that the Volt/VAr control parameterizations for each hosting condition can be readjusted. A concept of PV generation center (PVGC) is adopted. A realistic case study is carried out on a 70-bus system, evaluating the network state at 10-minute intervals throughout a day, in two distinct scenarios: (i) with a PVGC closer to the primary substation, and (ii) with a PVGC farther away. The results show that there is a more pronounced increase in voltages and ohmic losses when the generation center is closer to the primary substation. Additionally, it was observed that MHC may be restricted more by branch loading limits than voltage limits, being 45% lower when the PVGC is close to the substation and 60% lower when it is far away.
- 18 October 2023
- Published by SWGE Sistemas Ltda in Anais Do Vi Simpósio Brasileiro de Sistemas Elétricos
- Vol. 1 (2)
Open AccessUma Avaliação em Série-Temporal Quase-Estática da Capacidade de Hospedagem de Geração FV em Redes de Distribuição
The increasing penetration of photovoltaic (PV) generation in Brazilian distribution networks has brought a set of operational, safety, and compliance challenges. In this scenario, maximum hosting capacity (MHC) assessment studies are necessary to evaluate the impacts of these systems on the operational states of electrical networks. Currently, there is a growing interest in this topic in the scientific literature, however, given the complexities and intermittencies involved, the subject still lacks lessons learned and definitions of best practices. This article aims to evaluate MHC in distribution networks through quasi-static time-series simulations and heuristic methods, so that the Volt/VAr control parameterizations for each hosting condition can be readjusted. A concept of PV generation center (PVGC) is adopted. A realistic case study is carried out on a 70-bus system, evaluating the network state at 10-minute intervals throughout a day, in two distinct scenarios: (i) with a PVGC closer to the primary substation, and (ii) with a PVGC farther away. The results show that there is a more pronounced increase in voltages and ohmic losses when the generation center is closer to the primary substation. Additionally, it was observed that MHC may be restricted more by branch loading limits than voltage limits, being 45% lower when the PVGC is close to the substation and 60% lower when it is far away.
- Open Access
- 1 January 2019
- Published by Galoa Events Proceedings
Forecasting Electric Power Generation of Grid-Connected Solar Photovoltaic Systems by Using Artificial Neural Networks
- 1 January 2019
- Published by Galoa Events Proceedings
Open AccessForecasting Electric Power Generation of Grid-Connected Solar Photovoltaic Systems by Using Artificial Neural Networks
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Application of artificial neural networks for discrimination of nonlinear loads
Smart Grids requires a complex infrastructure. It is associated with the advanced metering system which is responsible for data acquisition and processing. Taking into account this new paradigm, this paper proposes the application of Artificial Neural Networks for classification of nonlinear loads that are connected to the electrical system by using signals processed for each sample. For this purpose, multilayer perceptron and radial basis functions neural network have been used for training and validation. The results have shown good results such as the performance above 90% of accuracy in the correct classification.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Application of artificial neural networks for discrimination of nonlinear loads
Smart Grids requires a complex infrastructure. It is associated with the advanced metering system which is responsible for data acquisition and processing. Taking into account this new paradigm, this paper proposes the application of Artificial Neural Networks for classification of nonlinear loads that are connected to the electrical system by using signals processed for each sample. For this purpose, multilayer perceptron and radial basis functions neural network have been used for training and validation. The results have shown good results such as the performance above 90% of accuracy in the correct classification.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Artificial neural network applied to prediction of electricity generated by Grid connected photovoltaic systems
This paper applies Artificial Neural Network to predict the amount of energy generated by a Grid Connected Photovoltaic System installed at the Institute of Electrotechnic and Energy of University of São Paulo (IEE/USP). Irradiance, back cell temperature and power data were collected during the period of one year. This methodology allows performing an analysis of the production of Grid Connected Photovoltaic Systems and the commercialization of the energy generated. Finally, the methodology was validated comparing relative error between measured data and estimated data.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Artificial neural network applied to prediction of electricity generated by Grid connected photovoltaic systems
This paper applies Artificial Neural Network to predict the amount of energy generated by a Grid Connected Photovoltaic System installed at the Institute of Electrotechnic and Energy of University of São Paulo (IEE/USP). Irradiance, back cell temperature and power data were collected during the period of one year. This methodology allows performing an analysis of the production of Grid Connected Photovoltaic Systems and the commercialization of the energy generated. Finally, the methodology was validated comparing relative error between measured data and estimated data.