Pavel Leinveber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pavel Leinveber has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Karol Curila
Cardiocenter, Third Faculty of Medicine Charles University and University Hospital Kralovske Vinohrady Prague Czechia
4 shared publications - Radovan Smisek
Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic
4 shared publications - Filip Plesinger
Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic
3 shared publications - Ivo Viscor
Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic
3 shared publications - Josef Halamek
Institute of Scientific Instruments, Czech Academy of Sciences Brno Czech Republic
2 shared publications - Pavel Jurak
Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic
2 shared publications
Latest Publications
- Open Access
- 2 September 2026
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 6 (5)
Optimal depolarization sequence for cardiac resynchronization therapy patients
Aims: Electrical ventricular dyssynchrony is a hallmark of intraventricular conduction disease in heart failure with reduced ejection fraction. Although cardiac resynchronization therapy (CRT) is effective, a proportion of patients with electrical dyssynchrony evidenced by an electrocardiogram (ECG) remain non-responders. Besides the QRS duration, visualization and quantification of the depolarization sequence could contribute to improving CRT response. The study aimed to evaluate the CineECG-derived mean temporo-spatial isochrone trajectory of depolarization in CRT patients. Methods and results: Among the adult cohort of 121 patients who underwent CRT implantation, there were 93 (33% female) responders and 28 (7% female) non-responders. ECGs recorded before and immediately after CRT implantation were collected and analysed using the CineECG modality with a generic heart/torso model. The CineECG-derived path directions were computed for the QRS on anteroposterior, interventricular, and apicobasal axes within the cardiac anatomy. Spatial depolarization characteristics were tested for the association with left ventricle reverse-remodelling at 6-month follow-up. The pre-implantation depolarization sequence was predominantly from the right to the left ventricle, and after the CRT implant, it has been transformed into an apicobasal direction. In multivariate logistic regression, the pre-implant QRS duration, apicobasal depolarization gradient, and CRT-induced QRS shortening independently predicted CRT response. The Akaike information criterion indicated that combining all three yielded the strongest predictive model. Conclusion: CineECG-derived depolarization gradients, which reflect ventricular activation sequence, changed significantly after CRT, and the pre-implantation apicobasal gradient independently predicted echocardiographic outcome, with a less pronounced gradient associated with better haemodynamic response.
- 2 September 2026
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 6 (5)
Open AccessOptimal depolarization sequence for cardiac resynchronization therapy patients
Aims: Electrical ventricular dyssynchrony is a hallmark of intraventricular conduction disease in heart failure with reduced ejection fraction. Although cardiac resynchronization therapy (CRT) is effective, a proportion of patients with electrical dyssynchrony evidenced by an electrocardiogram (ECG) remain non-responders. Besides the QRS duration, visualization and quantification of the depolarization sequence could contribute to improving CRT response. The study aimed to evaluate the CineECG-derived mean temporo-spatial isochrone trajectory of depolarization in CRT patients. Methods and results: Among the adult cohort of 121 patients who underwent CRT implantation, there were 93 (33% female) responders and 28 (7% female) non-responders. ECGs recorded before and immediately after CRT implantation were collected and analysed using the CineECG modality with a generic heart/torso model. The CineECG-derived path directions were computed for the QRS on anteroposterior, interventricular, and apicobasal axes within the cardiac anatomy. Spatial depolarization characteristics were tested for the association with left ventricle reverse-remodelling at 6-month follow-up. The pre-implantation depolarization sequence was predominantly from the right to the left ventricle, and after the CRT implant, it has been transformed into an apicobasal direction. In multivariate logistic regression, the pre-implant QRS duration, apicobasal depolarization gradient, and CRT-induced QRS shortening independently predicted CRT response. The Akaike information criterion indicated that combining all three yielded the strongest predictive model. Conclusion: CineECG-derived depolarization gradients, which reflect ventricular activation sequence, changed significantly after CRT, and the pre-implantation apicobasal gradient independently predicted echocardiographic outcome, with a less pronounced gradient associated with better haemodynamic response.
- 18 June 2026
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 12 (10) , 2544-2554
UHF-ECG Outperforms QRS Duration and Morphology in Predicting Responders to Biventricular Cardiac Resynchronization Therapy
- 18 June 2026
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 12 (10) , 2544-2554
UHF-ECG Outperforms QRS Duration and Morphology in Predicting Responders to Biventricular Cardiac Resynchronization Therapy
- Open Access
- 1 November 2022
- Published by Wiley in Software: Practice and Experience
- Vol. 53 (2) , 455-464
DeepPlayer: An open‐source SignalPlant plugin for deep learning inference
- 1 November 2022
- Published by Wiley in Software: Practice and Experience
- Vol. 53 (2) , 455-464
Open AccessDeepPlayer: An open‐source SignalPlant plugin for deep learning inference
- Open Access
- 23 February 2022
- Published by Wiley in Clinical Cardiology
- Vol. 45 (4) , 386-390
Obstructive sleep apnea in patients with acute aortic dissection
Background: Obstructive sleep apnea (OSA) imposes an afterload burden on the left ventricle and increases the pressure gradient across the aortic wall. Thus, OSA may increase the risk for aortic dissection (AD).Methods: This study enrolled 40 subjects with acute AD from four institutions; 37 completed the modified Berlin Questionnaire and 31 underwent attended overnight polysomnography. Aortic diameter was measured on a computed tomography scan at seven locations from the sinotubular junction to the diaphragm.Results: Twenty‐seven subjects had type A dissection; 13 had type B. In those who had polysomnography apnea–hypopnea index (AHI) ranged from 0.7 to 89. Prevalence of OSA (AHI ≥ 5) was 61%. Nocturnal presentation (10 p.m.–7 a.m.) did not differ by presence/absence of OSA. The modified Berlin Questionnaire was not predictive of the presence of OSA. Among type A subjects with polysomnography (n = 23), aortic diameters at all locations were greater in the OSA group though differences were not statistically significant. Summating aortic diameters at the seven locations also yielded a numerically larger mean value in the OSA group versus the non‐OSA group.Conclusions: In this sample of patients with acute dissection, OSA was prevalent but was not associated with a nocturnal presentation. The presence of underlying OSA may be associated with larger aortic diameters at the time of dissection compared to patients without OSA. Though differences did not meet statistical significance the current series is limited by small numbers.
- 23 February 2022
- Published by Wiley in Clinical Cardiology
- Vol. 45 (4) , 386-390
Open AccessObstructive sleep apnea in patients with acute aortic dissection
Background: Obstructive sleep apnea (OSA) imposes an afterload burden on the left ventricle and increases the pressure gradient across the aortic wall. Thus, OSA may increase the risk for aortic dissection (AD).Methods: This study enrolled 40 subjects with acute AD from four institutions; 37 completed the modified Berlin Questionnaire and 31 underwent attended overnight polysomnography. Aortic diameter was measured on a computed tomography scan at seven locations from the sinotubular junction to the diaphragm.Results: Twenty‐seven subjects had type A dissection; 13 had type B. In those who had polysomnography apnea–hypopnea index (AHI) ranged from 0.7 to 89. Prevalence of OSA (AHI ≥ 5) was 61%. Nocturnal presentation (10 p.m.–7 a.m.) did not differ by presence/absence of OSA. The modified Berlin Questionnaire was not predictive of the presence of OSA. Among type A subjects with polysomnography (n = 23), aortic diameters at all locations were greater in the OSA group though differences were not statistically significant. Summating aortic diameters at the seven locations also yielded a numerically larger mean value in the OSA group versus the non‐OSA group.Conclusions: In this sample of patients with acute dissection, OSA was prevalent but was not associated with a nocturnal presentation. The presence of underlying OSA may be associated with larger aortic diameters at the time of dissection compared to patients without OSA. Though differences did not meet statistical significance the current series is limited by small numbers.
- 11 May 2021
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 32 (5)
Cover Image, Volume 32, Issue 5
- 11 May 2021
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 32 (5)
Cover Image, Volume 32, Issue 5
- 27 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (10) , 2721-2734
Real-Time Quality Assessment of Long-Term ECG Signals Recorded by Wearables in Free-Living Conditions
Nowadays, methods for ECG quality assessment are mostly designed to binary distinguish between good/bad quality of the whole signal. Such classification is not suitable to long-term data collected by wearable devices. In this paper, a novel approach to estimate long-term ECG signal quality is proposed. The real-time quality estimation is performed in a local time window by calculation of continuous signal-to-noise ratio (SNR) curve. The layout of the data quality segments is determined by analysis of SNR waveform. It is distinguished between three levels of ECG signal quality: signal suitable for full wave ECG analysis, signal suitable only for QRS detection, and signal unsuitable for further processing. The SNR limits for reliable QRS detection and full ECG waveform analysis are 5 and 18 dB respectively. The method was developed and tested using synthetic data and validated on real data from wearable device. The proposed solution is a robust, accurate and computationally efficient algorithm for annotation of ECG signal quality that will facilitate the subsequent tailored analysis of ECG signals recorded in free-living conditions. The field of long-term ECG signals self-monitoring by wearable devices is swiftly developing. The analysis of massive amount of collected data is time consuming. It is advantageous to characterize data quality in advance and thereby limit consequent analysis to useable signals.
- 27 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (10) , 2721-2734
Real-Time Quality Assessment of Long-Term ECG Signals Recorded by Wearables in Free-Living Conditions
Nowadays, methods for ECG quality assessment are mostly designed to binary distinguish between good/bad quality of the whole signal. Such classification is not suitable to long-term data collected by wearable devices. In this paper, a novel approach to estimate long-term ECG signal quality is proposed. The real-time quality estimation is performed in a local time window by calculation of continuous signal-to-noise ratio (SNR) curve. The layout of the data quality segments is determined by analysis of SNR waveform. It is distinguished between three levels of ECG signal quality: signal suitable for full wave ECG analysis, signal suitable only for QRS detection, and signal unsuitable for further processing. The SNR limits for reliable QRS detection and full ECG waveform analysis are 5 and 18 dB respectively. The method was developed and tested using synthetic data and validated on real data from wearable device. The proposed solution is a robust, accurate and computationally efficient algorithm for annotation of ECG signal quality that will facilitate the subsequent tailored analysis of ECG signals recorded in free-living conditions. The field of long-term ECG signals self-monitoring by wearable devices is swiftly developing. The analysis of massive amount of collected data is time consuming. It is advantageous to characterize data quality in advance and thereby limit consequent analysis to useable signals.
- 30 May 2018
- Published by Springer Nature
- p. 435-439
Automatic Detection of Strict Left Bundle Branch Block
- 30 May 2018
- Published by Springer Nature
- p. 435-439
Automatic Detection of Strict Left Bundle Branch Block