Yiping Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yiping Du has a total of 237 co-authors. Here are the top co-authors by number of shared publications:
Ting Wu
28 shared publicationsYan Kang
School of Chemistry and Molecular Engineering & Shanghai Key Laboratory of Functional Materials Chemistry, and Research Centre of Analysis and Test
16 shared publications- Jibran Iqbal
College of Natural and Health Sciences, Zayed University, Abu Dhabi, 144534, United Arab Emirates
15 shared publications - Ting Wu
College of Food Science and Technology, Huazhong Agricultural University, Wuhan 430070, China
13 shared publications Han Zhang
School of Chemistry and Molecular Engineering and Shanghai Key Laboratory of Functional Materials Chemistry, and Research Centre of Analysis and Test, East China University of Science and Technology, Shanghai 200237, China
11 shared publicationsXuan Wang
East China University of Science and Technology
11 shared publications
Latest Publications
- 8 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (24) , 17697-17706
Interpretable CNN-Transformer Multimodal Hierarchical Fusion Network in Multivariate Calibration
This study proposed a novel multimodal hierarchical fusion framework integrating a convolutional neural network (CNN) and a transformer. The approach enhanced model performance by fusing spectral features with some auxiliary factors of the samples, such as the locality of growth (region), type of produce (cultivar), and sample temperature (temp). Spectral data were extracted using one-dimensional CNN to capture local spectral features, while auxiliary factors underwent sine-cosine or label encoding before being embedded into the same feature space as spectral data via a fully connected network. Ultimately, a transformer was employed to achieve global interaction and fusion between spectral features and auxiliary factors rather than merely concatenating different feature types. The fusion strategy was validated using the ultraviolet (UV)-visible (vis)-near-infrared (NIR) spectra of mango and tobacco data sets. Compared to single-modal models using spectra only, the multimodal model using spectra coupled with the auxiliary factors achieved improved prediction performance on both validation and test sets for the mango dry matter content (DMC). The RMSE decreased from 0.984 and 1.03 to 0.577 and 0.613, respectively. These results outperformed those of the other 11 machine learning models. SHAP analysis revealed that the CNN-transformer framework successfully captured the underlying relationships between auxiliary factors (region, temp, and cultivar) and spectral features near 960 nm (due to the O-H absorption signal) with DMC, with the former contributing more significantly to the model than the latter. Similar observations were obtained in the tobacco data set. The results demonstrated the advantages of the CNN-transformer multimodal model in overcoming the limitations of single-modal information, providing novel technical support for quantitative analysis.
- 8 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (24) , 17697-17706
Interpretable CNN-Transformer Multimodal Hierarchical Fusion Network in Multivariate Calibration
This study proposed a novel multimodal hierarchical fusion framework integrating a convolutional neural network (CNN) and a transformer. The approach enhanced model performance by fusing spectral features with some auxiliary factors of the samples, such as the locality of growth (region), type of produce (cultivar), and sample temperature (temp). Spectral data were extracted using one-dimensional CNN to capture local spectral features, while auxiliary factors underwent sine-cosine or label encoding before being embedded into the same feature space as spectral data via a fully connected network. Ultimately, a transformer was employed to achieve global interaction and fusion between spectral features and auxiliary factors rather than merely concatenating different feature types. The fusion strategy was validated using the ultraviolet (UV)-visible (vis)-near-infrared (NIR) spectra of mango and tobacco data sets. Compared to single-modal models using spectra only, the multimodal model using spectra coupled with the auxiliary factors achieved improved prediction performance on both validation and test sets for the mango dry matter content (DMC). The RMSE decreased from 0.984 and 1.03 to 0.577 and 0.613, respectively. These results outperformed those of the other 11 machine learning models. SHAP analysis revealed that the CNN-transformer framework successfully captured the underlying relationships between auxiliary factors (region, temp, and cultivar) and spectral features near 960 nm (due to the O-H absorption signal) with DMC, with the former contributing more significantly to the model than the latter. Similar observations were obtained in the tobacco data set. The results demonstrated the advantages of the CNN-transformer multimodal model in overcoming the limitations of single-modal information, providing novel technical support for quantitative analysis.
- 15 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (8) , 1618-1625
Monitoring production processes of pharmaceuticals and farm chemicals with near-infrared spectroscopy coupled with the interaction moving window partial least squares method
The novel iMWPLS algorithm optimally selects NIR spectral intervals, boosting PLS model accuracy for online process monitoring. It offers a robust, interpretable tool for NIR-based quality control in pharmaceuticals.
- 15 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (8) , 1618-1625
Monitoring production processes of pharmaceuticals and farm chemicals with near-infrared spectroscopy coupled with the interaction moving window partial least squares method
The novel iMWPLS algorithm optimally selects NIR spectral intervals, boosting PLS model accuracy for online process monitoring. It offers a robust, interpretable tool for NIR-based quality control in pharmaceuticals.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (30) , 6345-6353
Effect of cryopreservation conditions on transdermal permeation of skin by two-dimensional Raman spectroscopic imaging
Cross-validation using two-dimensional Raman imaging and HPLC.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (30) , 6345-6353
Effect of cryopreservation conditions on transdermal permeation of skin by two-dimensional Raman spectroscopic imaging
Cross-validation using two-dimensional Raman imaging and HPLC.
- 26 June 2025
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 113 (3) , 116980
Multiplexed MALDI fingerprints for rapid detection of spontaneous bacterial peritonitis
- 26 June 2025
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 113 (3) , 116980
Multiplexed MALDI fingerprints for rapid detection of spontaneous bacterial peritonitis
- 6 May 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (20) , 10603-10610
Local Asymmetric Gaussian Fitting Algorithm for Enhanced Peak Detection of Liquid Chromatography–High Resolution Mass Spectrometry Data
Feature detection is a crucial step in the data preprocessing workflow of liquid chromatography-mass spectrometry (LC-MS). However, many existing methods are hindered by intricate parameter adjustments and high false positive rates during extracted ion chromatogram (EIC) construction and peak detection, which challenges the identification of spurious and missing compounds. This study introduces a novel algorithm, local asymmetric Gaussian fitting (LAGF), for peak detection. LAGF integrates with the "data points bins" EIC extraction algorithm to enhance the feature detection efficiency. By using a 1 Da data points bin for EIC extraction, computational time is significantly reduced, making the method well-suited for batch metabolomics analysis. LAGF minimizes parameter numbers of generalized two-sided asymmetric Gaussian fitting by automatically determining the peak center (μ) and height (α) while accommodating two-sided standard deviations (σ1 and σ2) to self-adaptively model peak patterns. Features are filtered based on a goodness-of-fit threshold of 0.5. The performance of LAGF was validated using standard mixtures and serum samples at different concentrations in reversed-phase or hydrophilic interaction LC mode. In most cases, LAGF outperformed conventional tools in terms of determination coefficient (R2) and relative standard deviation for automatically detected peak areas. The LAGF algorithm is available as open-source Python code alongside an interactive interface, facilitating implementation in both nontargeted and targeted LC-MS analysis to enhance peak detection and compound identification.
- 6 May 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (20) , 10603-10610
Local Asymmetric Gaussian Fitting Algorithm for Enhanced Peak Detection of Liquid Chromatography–High Resolution Mass Spectrometry Data
Feature detection is a crucial step in the data preprocessing workflow of liquid chromatography-mass spectrometry (LC-MS). However, many existing methods are hindered by intricate parameter adjustments and high false positive rates during extracted ion chromatogram (EIC) construction and peak detection, which challenges the identification of spurious and missing compounds. This study introduces a novel algorithm, local asymmetric Gaussian fitting (LAGF), for peak detection. LAGF integrates with the "data points bins" EIC extraction algorithm to enhance the feature detection efficiency. By using a 1 Da data points bin for EIC extraction, computational time is significantly reduced, making the method well-suited for batch metabolomics analysis. LAGF minimizes parameter numbers of generalized two-sided asymmetric Gaussian fitting by automatically determining the peak center (μ) and height (α) while accommodating two-sided standard deviations (σ1 and σ2) to self-adaptively model peak patterns. Features are filtered based on a goodness-of-fit threshold of 0.5. The performance of LAGF was validated using standard mixtures and serum samples at different concentrations in reversed-phase or hydrophilic interaction LC mode. In most cases, LAGF outperformed conventional tools in terms of determination coefficient (R2) and relative standard deviation for automatically detected peak areas. The LAGF algorithm is available as open-source Python code alongside an interactive interface, facilitating implementation in both nontargeted and targeted LC-MS analysis to enhance peak detection and compound identification.
- 11 April 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (16) , 9042-9048
Equivalent and Complementary Variables Screening for the Optimization of Wavelengths in Spectral Multivariate Calibration
Equivalent variables (EVs) were defined on the basis of a finding that replacing a selected variable with its neighbor variable provided a similar model performance. These are a group of variables having nearly equal modeling effects and can be efficient alternative to each other. Complementary variables (CVs) were defined as different variables screened from different variable selection algorithms that can further improve multivariate calibration by combining CVs with the original selected variables. Three variable selection algorithms, stability competitive adaptive reweighted sampling (SCARS), competitive adaptive reweighted sampling (CARS), and Monte Carlo and uninformative variable elimination (MC-UVE), were used for screening EVs and CVs and verifying the replaceability of EVs and model improvability with CVs. The developed strategy of variable selection based on EVs and CVs was investigated using NIR, MIR, and UV-vis spectra datasets. Seventeen basic variables (BVs) and 54 EVs were screened from the corn NIR spectra by SCARS. The selected EVs and BVs were comparable to one another in terms of modeling, and all models built with replaced variables showed close prediction errors with a RMSEP deviation <0.003. Furthermore, 15 CVs of SCARS were screened from EVs of CARS and MC-UVE. The combination of CVs and BVs of SCARS can significantly improve model performance; RMSEC and RMSEP decreased from 0.0207 and 0.0290 to 0.0109 and 0.0136, respectively. Similar results were obtained for other datasets. Results revealed that screening CVs from EVs of other algorithms and combining BVs could effectively optimize variable selection and improve model performance.
- 11 April 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (16) , 9042-9048
Equivalent and Complementary Variables Screening for the Optimization of Wavelengths in Spectral Multivariate Calibration
Equivalent variables (EVs) were defined on the basis of a finding that replacing a selected variable with its neighbor variable provided a similar model performance. These are a group of variables having nearly equal modeling effects and can be efficient alternative to each other. Complementary variables (CVs) were defined as different variables screened from different variable selection algorithms that can further improve multivariate calibration by combining CVs with the original selected variables. Three variable selection algorithms, stability competitive adaptive reweighted sampling (SCARS), competitive adaptive reweighted sampling (CARS), and Monte Carlo and uninformative variable elimination (MC-UVE), were used for screening EVs and CVs and verifying the replaceability of EVs and model improvability with CVs. The developed strategy of variable selection based on EVs and CVs was investigated using NIR, MIR, and UV-vis spectra datasets. Seventeen basic variables (BVs) and 54 EVs were screened from the corn NIR spectra by SCARS. The selected EVs and BVs were comparable to one another in terms of modeling, and all models built with replaced variables showed close prediction errors with a RMSEP deviation <0.003. Furthermore, 15 CVs of SCARS were screened from EVs of CARS and MC-UVE. The combination of CVs and BVs of SCARS can significantly improve model performance; RMSEC and RMSEP decreased from 0.0207 and 0.0290 to 0.0109 and 0.0136, respectively. Similar results were obtained for other datasets. Results revealed that screening CVs from EVs of other algorithms and combining BVs could effectively optimize variable selection and improve model performance.
- 15 November 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (1) , 184-192
Integration of a Raman spectroscopic platform based on online sampling to monitor chemical reaction processes
During the pharmaceutical synthesis process, it is essential to control the reaction time to avoid by-product formation and the reduction of yield. In this study, a Raman spectroscopic platform based on online sampling was integrated to collect Raman spectra in real time and realize process monitoring. Considering its attractive features of strong light transmittance and resistance to acids, alkalis and high temperatures, polyfluoroalkoxy (PFA) tubes rather than cuvette-type flow cells or similar devices were used to transfer solutions and as a flow cell for collecting Raman spectra, therefore not requiring an in situ Raman probe, and significantly reducing the cost of equipment. The peristaltic pump is controlled by the sampling software to realize automatic sampling, and it automatically pushes the reaction solution back into the reaction vessel after the spectra are collected. Taking the aspirin synthesis reaction as an example, the platform was employed to monitor the chemical reaction in real-time. The internal standard method was adopted to minimize the interference of spectral oscillation and baseline drift during online monitoring. The characteristic peak of the PFA tube at 731 cm−1 was selected as the internal standard peak, which formed the relative intensity ratio R with the characteristic peak of the product acetylsalicylic acid at 1606 cm−1. The endpoint of the reaction was identified based on the trend of the relative intensity ratio with the reaction time. The results indicate that the method is feasible for monitoring the aspirin synthesis reaction and provides a research basis for real-time monitoring of other pharmaceutical processes.
- 15 November 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (1) , 184-192
Integration of a Raman spectroscopic platform based on online sampling to monitor chemical reaction processes
During the pharmaceutical synthesis process, it is essential to control the reaction time to avoid by-product formation and the reduction of yield. In this study, a Raman spectroscopic platform based on online sampling was integrated to collect Raman spectra in real time and realize process monitoring. Considering its attractive features of strong light transmittance and resistance to acids, alkalis and high temperatures, polyfluoroalkoxy (PFA) tubes rather than cuvette-type flow cells or similar devices were used to transfer solutions and as a flow cell for collecting Raman spectra, therefore not requiring an in situ Raman probe, and significantly reducing the cost of equipment. The peristaltic pump is controlled by the sampling software to realize automatic sampling, and it automatically pushes the reaction solution back into the reaction vessel after the spectra are collected. Taking the aspirin synthesis reaction as an example, the platform was employed to monitor the chemical reaction in real-time. The internal standard method was adopted to minimize the interference of spectral oscillation and baseline drift during online monitoring. The characteristic peak of the PFA tube at 731 cm−1 was selected as the internal standard peak, which formed the relative intensity ratio R with the characteristic peak of the product acetylsalicylic acid at 1606 cm−1. The endpoint of the reaction was identified based on the trend of the relative intensity ratio with the reaction time. The results indicate that the method is feasible for monitoring the aspirin synthesis reaction and provides a research basis for real-time monitoring of other pharmaceutical processes.
- 7 November 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (1) , 37-44
Deamidation analysis of therapeutic drugs using matrix-assisted laser desorption ionization mass spectrometry and a novel algorithm QuanDA
A robust deamidation quantification method, called QuanDA, was developed to quantify the spontaneous nonenzymatic deamidation of peptides based on the isotopic distribution change of peptides in matrix-assisted laser desorption ionization (MALDI) mass spectra and non-negative least squares calculation. The predictive model of QuanDA using theoretical spectra of pure un-deamidated and deamidated peptides for a series of simulated partial deamidated peptides is satisfying, with a coefficient of determination (R2) and root mean squared error (RMSE) of 0.9914 and 0.03356, respectively. It was applicable in cases where there is a lack of reference standards of un-deamidated and deamidated peptides. The only requirements were the chemical formulae of un-deamidated and deamidated peptides for isotopic pattern calculation. QuanDA provided a rapid, low-cost and easily accessible method for deamidation analysis in therapeutic drugs.
- 7 November 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (1) , 37-44
Deamidation analysis of therapeutic drugs using matrix-assisted laser desorption ionization mass spectrometry and a novel algorithm QuanDA
A robust deamidation quantification method, called QuanDA, was developed to quantify the spontaneous nonenzymatic deamidation of peptides based on the isotopic distribution change of peptides in matrix-assisted laser desorption ionization (MALDI) mass spectra and non-negative least squares calculation. The predictive model of QuanDA using theoretical spectra of pure un-deamidated and deamidated peptides for a series of simulated partial deamidated peptides is satisfying, with a coefficient of determination (R2) and root mean squared error (RMSE) of 0.9914 and 0.03356, respectively. It was applicable in cases where there is a lack of reference standards of un-deamidated and deamidated peptides. The only requirements were the chemical formulae of un-deamidated and deamidated peptides for isotopic pattern calculation. QuanDA provided a rapid, low-cost and easily accessible method for deamidation analysis in therapeutic drugs.
- 6 November 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 327, 125396
Continuous solid-phase extraction spectroscopy and its quantification method for trace analysis
- 6 November 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 327, 125396
Continuous solid-phase extraction spectroscopy and its quantification method for trace analysis