Local Asymmetric Gaussian Fitting Algorithm for Enhanced Peak Detection of Liquid Chromatography–High Resolution Mass Spectrometry Data
- 6 May 2025
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (20) , 10603-10610
Abstract
Feature detection is a crucial step in the data preprocessing workflow of liquid chromatography-mass spectrometry (LC-MS). However, many existing methods are hindered by intricate parameter adjustments and high false positive rates during extracted ion chromatogram (EIC) construction and peak detection, which challenges the identification of spurious and missing compounds. This study introduces a novel algorithm, local asymmetric Gaussian fitting (LAGF), for peak detection. LAGF integrates with the "data points bins" EIC extraction algorithm to enhance the feature detection efficiency. By using a 1 Da data points bin for EIC extraction, computational time is significantly reduced, making the method well-suited for batch metabolomics analysis. LAGF minimizes parameter numbers of generalized two-sided asymmetric Gaussian fitting by automatically determining the peak center (μ) and height (α) while accommodating two-sided standard deviations (σ1 and σ2) to self-adaptively model peak patterns. Features are filtered based on a goodness-of-fit threshold of 0.5. The performance of LAGF was validated using standard mixtures and serum samples at different concentrations in reversed-phase or hydrophilic interaction LC mode. In most cases, LAGF outperformed conventional tools in terms of determination coefficient (R2) and relative standard deviation for automatically detected peak areas. The LAGF algorithm is available as open-source Python code alongside an interactive interface, facilitating implementation in both nontargeted and targeted LC-MS analysis to enhance peak detection and compound identification.Keywords
This publication has 37 references indexed in Scilit:
- Influence of theoretical and semi-empirical peak models on the efficiency calculation in chiral chromatographyTalanta, 2024
- Suspect and nontarget screening of known and unknown organophosphate esters (OPEs) in soil samplesJournal of Hazardous Materials, 2022
- Overview of Experimental Methods and Study Design in Metabolomics, and Statistical and Pathway Considerations2020
- Metabolomics Data Processing Using OpenMS2020
- Automated optimization of XCMS parameters for improved peak picking of liquid chromatography–mass spectrometry data using the coefficient of variation and parameter sweeping for untargeted metabolomicsDrug Testing and Analysis, 2018
- Data Conversion with ProteoWizard msConvert2017
- Optimization of LC-Orbitrap-HRMS acquisition and MZmine 2 data processing for nontarget screening of environmental samples using design of experimentsAnalytical and Bioanalytical Chemistry, 2016
- LC‐MS Data Processing with MAVEN: A Metabolomic Analysis and Visualization EngineCurrent Protocols in Bioinformatics, 2012
- XCMS: Processing Mass Spectrometry Data for Metabolite Profiling Using Nonlinear Peak Alignment, Matching, and IdentificationAnalytical Chemistry, 2006
- Analysis of peak asymmetry in chromatographyJournal of Chromatography A, 2002