Shailendra Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shailendra Kumar has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
- Bhim Singh
Indian Institute of Technology Delhi
36 shared publications Dulichand Jaraniya
Shakti Pumps (India) Ltd., Indore, India
7 shared publicationsShashank Kurm
Electrical Engineering Department, Indian, Institute of Technology Bhilai, Chhattisgarh, India
7 shared publications- Ahmed Al-Durra
Khalifa University
6 shared publications - Dulichand Jaraniya
Shakti Pumps (India) Limited, Dhar, India
4 shared publications - Tanu Prasad
Electrical Engineering Department, Indian, Institute of Technology Bhilai, Chhattisgarh, India
4 shared publications
Latest Publications
- 2 August 2026
- Published by Springer Nature
- p. 85-98
Solar Photovoltaic Power Generation System for Grid Integration Using Sparse Adoption Control Algorithm
- 2 August 2026
- Published by Springer Nature
- p. 85-98
Solar Photovoltaic Power Generation System for Grid Integration Using Sparse Adoption Control Algorithm
- 9 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-12
Electrolyser-PV-Battery System for Hybrid EV Charging Stations With Grid Integration and Islanding Control by Using DHOQ Based PLL
This paper proposes a Modified Versoria Zero Attraction-based Least Mean Square (MVZA-LMS) control strategy for a grid-supportive PV battery system designed for hydrogen production and uninterrupted power supply in hybrid EV charging stations. The system ensures seamless operation in grid-connected and islanded modes, maintaining power delivery during grid outages. In grid-connected mode, current control extracts reference currents, suppresses harmonics, and supports accurate parameter estimation under distorted conditions. In islanded mode, voltage control ensures a stable power supply to the electrolyzer and local loads. A Dual Higher-Order Generalized Integrator Quasi-Type 2 (DHOQ)-based PLL ensures synchronization across modes. A PV feed-forward loop enhances power extraction and grid integration. Simulation and OPAL-RT-based real-time experiments validate the system's smooth mode transitions, compliance with IEEE-519-2022 THD standards, and robust performance across diverse conditions. The proposed strategy enhances system stability, bridging simulation, and practical deployment and offers a reliable solution for hydrogen generation and EV charging in grid-connected and off-grid settings.
- 9 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-12
Electrolyser-PV-Battery System for Hybrid EV Charging Stations With Grid Integration and Islanding Control by Using DHOQ Based PLL
This paper proposes a Modified Versoria Zero Attraction-based Least Mean Square (MVZA-LMS) control strategy for a grid-supportive PV battery system designed for hydrogen production and uninterrupted power supply in hybrid EV charging stations. The system ensures seamless operation in grid-connected and islanded modes, maintaining power delivery during grid outages. In grid-connected mode, current control extracts reference currents, suppresses harmonics, and supports accurate parameter estimation under distorted conditions. In islanded mode, voltage control ensures a stable power supply to the electrolyzer and local loads. A Dual Higher-Order Generalized Integrator Quasi-Type 2 (DHOQ)-based PLL ensures synchronization across modes. A PV feed-forward loop enhances power extraction and grid integration. Simulation and OPAL-RT-based real-time experiments validate the system's smooth mode transitions, compliance with IEEE-519-2022 THD standards, and robust performance across diverse conditions. The proposed strategy enhances system stability, bridging simulation, and practical deployment and offers a reliable solution for hydrogen generation and EV charging in grid-connected and off-grid settings.
- 13 May 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (5) , 281
PV array-integrated power quality conditioner with JLHCF robust sparse adaptive control algorithm for grid stability
- 13 May 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (5) , 281
PV array-integrated power quality conditioner with JLHCF robust sparse adaptive control algorithm for grid stability
- 3 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 7 (3) , 1089-1098
Power Quality Enhancement Using Dynamic Voltage Restorer With Echo State Network and Type-2 Fuzzy Logic Control
This research proposes an Echo-State Network (ESN) driven strategy to improve Power Quality (PQ) in utility grids through Dynamic Voltage Restorer (DVR) implementation. With the growing integration of nonlinear or critical loads, PQ degradation has become a pressing concern. The ESN-based algorithm efficiently estimates fundamental voltage quantities from a disturbed grid and supports PQ improvement. The proposed approach integrates an Echo State Network (ESN) for real-time estimation of fundamental voltage components and an adaptive Interval Type-2 Fuzzy Logic (IT2 FLC) controller for DC link voltage stabilization. This dynamic controller mitigates voltage stress and maintains a robust DC voltage level, crucial for generating the reference load voltage. The controller gains are optimized using the bio-inspired Gorilla Troops Algorithm (GTA), which enables a low computational burden and enhanced adaptability to grid disturbances. Additionally, it is noteworthy that the proposed technique reduces the values of settle and rise time (0.15s, 0.19s), overshoot and undershoot (3.28%, 3.56%), and recovery time to 0.421s. These statistics indicate that it outperforms the traditional SRF-PI and LSM-IT1 FLC strategies. The hybrid ESN and GTA IT2 FLC framework allows online gain tuning, ensuring sinusoidal load voltage and a significant reduction in total harmonic distortion from 12.19% to 2.74%. The proposed method delivers superior performance even in disturbed grid conditions, offering fast rise time, minimal overshoot, and less steady-state errors compared to conventional SRF-PI and LMS-Fuzzy Logic Controller (LMS-FLC). The findings obtained from a scaled-down prototype of DVR highlight the approach's effectiveness.
- 3 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 7 (3) , 1089-1098
Power Quality Enhancement Using Dynamic Voltage Restorer With Echo State Network and Type-2 Fuzzy Logic Control
This research proposes an Echo-State Network (ESN) driven strategy to improve Power Quality (PQ) in utility grids through Dynamic Voltage Restorer (DVR) implementation. With the growing integration of nonlinear or critical loads, PQ degradation has become a pressing concern. The ESN-based algorithm efficiently estimates fundamental voltage quantities from a disturbed grid and supports PQ improvement. The proposed approach integrates an Echo State Network (ESN) for real-time estimation of fundamental voltage components and an adaptive Interval Type-2 Fuzzy Logic (IT2 FLC) controller for DC link voltage stabilization. This dynamic controller mitigates voltage stress and maintains a robust DC voltage level, crucial for generating the reference load voltage. The controller gains are optimized using the bio-inspired Gorilla Troops Algorithm (GTA), which enables a low computational burden and enhanced adaptability to grid disturbances. Additionally, it is noteworthy that the proposed technique reduces the values of settle and rise time (0.15s, 0.19s), overshoot and undershoot (3.28%, 3.56%), and recovery time to 0.421s. These statistics indicate that it outperforms the traditional SRF-PI and LSM-IT1 FLC strategies. The hybrid ESN and GTA IT2 FLC framework allows online gain tuning, ensuring sinusoidal load voltage and a significant reduction in total harmonic distortion from 12.19% to 2.74%. The proposed method delivers superior performance even in disturbed grid conditions, offering fast rise time, minimal overshoot, and less steady-state errors compared to conventional SRF-PI and LMS-Fuzzy Logic Controller (LMS-FLC). The findings obtained from a scaled-down prototype of DVR highlight the approach's effectiveness.
- 20 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-10
Advanced Control and Integration of Fuel Cell With Doubly Fed Induction Generators for Sustainable Power Generation
This paper introduces an advanced control mechanism for integration of a doubly fed induction generator (DFIG) based wind energy conversion system with a fuel cell and battery energy storage (BES) to the grid. The integration to grid has been achieved using the Modified Arc Tangent Logarithmic Hyperbolic Cosine Adaptive Filter (M-ATLHCAF). The control mechanism handles circumstances where load demand exceeds the rated capacity of the DFIG. The required power support comes from the BES and fuel cell to maintain stability and reliability. The efficacy of M-ATLHCAF is evaluated by comparing its performance with different adaptive filters such as conventional ATLHCAF, Joint LHCAF (JLHCAF), Reweighted Zero Attraction LHCAF (RZALHCAF), Traditional LHCAF, Least Mean Square (LMS) and $d$-$q$-based control methodologies. The simulation results and real-time analysis indicate that the proposed M-ATLHCAF achieves good dynamic response, enhanced power quality, and improved harmonic suppression. Furthermore, M-ATLHCAF maintains a total harmonic distortion of the grid current as low as $\bf{(0.88\%)}$, outperforming traditional methods. In addition, the M-ATLHCAF-based controller stabilises transients within 30 ms in simulation and 38 ms in real-time OPAL-RT validation, confirming rapid dynamic recovery alongside low harmonic content.
- 20 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-10
Advanced Control and Integration of Fuel Cell With Doubly Fed Induction Generators for Sustainable Power Generation
This paper introduces an advanced control mechanism for integration of a doubly fed induction generator (DFIG) based wind energy conversion system with a fuel cell and battery energy storage (BES) to the grid. The integration to grid has been achieved using the Modified Arc Tangent Logarithmic Hyperbolic Cosine Adaptive Filter (M-ATLHCAF). The control mechanism handles circumstances where load demand exceeds the rated capacity of the DFIG. The required power support comes from the BES and fuel cell to maintain stability and reliability. The efficacy of M-ATLHCAF is evaluated by comparing its performance with different adaptive filters such as conventional ATLHCAF, Joint LHCAF (JLHCAF), Reweighted Zero Attraction LHCAF (RZALHCAF), Traditional LHCAF, Least Mean Square (LMS) and $d$-$q$-based control methodologies. The simulation results and real-time analysis indicate that the proposed M-ATLHCAF achieves good dynamic response, enhanced power quality, and improved harmonic suppression. Furthermore, M-ATLHCAF maintains a total harmonic distortion of the grid current as low as $\bf{(0.88\%)}$, outperforming traditional methods. In addition, the M-ATLHCAF-based controller stabilises transients within 30 ms in simulation and 38 ms in real-time OPAL-RT validation, confirming rapid dynamic recovery alongside low harmonic content.
- 31 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-13
Robust Control Strategy for a PV-Battery-Electrolyser Based Hybrid EV Charging Infrastructure With Hydrogen Production and Seamless Grid Transitions
This paper presents a robust nonlinear active function-based filtered cross-recursive least squares (NLAFFxRLS) control strategy for a grid-supportive (PV)-battery-electrolyser-based hybrid (EV) charging infrastructure with hydrogen production. The primary objective of the charging infrastructure is to ensure continuous hydrogen production and uninterrupted power supply to local loads, even during grid outages. Charging infrastructure operates effectively in grid-connected and islanded modes, providing seamless transitions between them. This work also uses a modified notch filter second-order generalized integrator (MNF-SOGI)-based phase locked loop (PLL), categorized as a type-3 SOGI PLL, to enhance synchronization performance. In addition to its reconfigurability, system integrates maximum extracted PV power into utility grid through a PV feed-forward loop while suppressing harmonic currents generated by nonlinear loads connected to charging infrastructure. A bidirectional converter is integrated with battery, enabling energy flow in both directions, i.e., charging the battery during surplus power conditions and discharging it during power deficits. The electrolyser requires a stable and adjustable DC voltage for hydrogen production to optimize electrolysis. This is achieved using a full-bridge isolated buck converter, which steps down the input voltage to the desired level and maintains the operation's safety. The control method provides load balancing, harmonic elimination, reactive power compensation, and power factor correction. The presented test and simulated results are deemed satisfactory under different conditions. Total harmonic distortion (THD) of the grid parameters satisfies the IEEE 519-2022 requirements. The proposed approach demonstrates strong potential for practical deployment in hydrogen-based electric vehicle infrastructures, enabling reliable grid-to-island transitions with improved system stability.
- 31 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-13
Robust Control Strategy for a PV-Battery-Electrolyser Based Hybrid EV Charging Infrastructure With Hydrogen Production and Seamless Grid Transitions
This paper presents a robust nonlinear active function-based filtered cross-recursive least squares (NLAFFxRLS) control strategy for a grid-supportive (PV)-battery-electrolyser-based hybrid (EV) charging infrastructure with hydrogen production. The primary objective of the charging infrastructure is to ensure continuous hydrogen production and uninterrupted power supply to local loads, even during grid outages. Charging infrastructure operates effectively in grid-connected and islanded modes, providing seamless transitions between them. This work also uses a modified notch filter second-order generalized integrator (MNF-SOGI)-based phase locked loop (PLL), categorized as a type-3 SOGI PLL, to enhance synchronization performance. In addition to its reconfigurability, system integrates maximum extracted PV power into utility grid through a PV feed-forward loop while suppressing harmonic currents generated by nonlinear loads connected to charging infrastructure. A bidirectional converter is integrated with battery, enabling energy flow in both directions, i.e., charging the battery during surplus power conditions and discharging it during power deficits. The electrolyser requires a stable and adjustable DC voltage for hydrogen production to optimize electrolysis. This is achieved using a full-bridge isolated buck converter, which steps down the input voltage to the desired level and maintains the operation's safety. The control method provides load balancing, harmonic elimination, reactive power compensation, and power factor correction. The presented test and simulated results are deemed satisfactory under different conditions. Total harmonic distortion (THD) of the grid parameters satisfies the IEEE 519-2022 requirements. The proposed approach demonstrates strong potential for practical deployment in hydrogen-based electric vehicle infrastructures, enabling reliable grid-to-island transitions with improved system stability.
- 16 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (4) , 6513-6528
A Novel Sensor-Less Vector Controlled PMaSyRM Drive for Light Electric Vehicle Applications
This paper proposes a solar photovoltaic and battery-integrated drive system for light electric vehicles using a sensor-less vector-controlled permanent magnet-assisted synchronous reluctance motor (PMaSyRM). A bidirectional DC-DC converter supports regenerative braking and stabilizes the DC link voltage. Motor control is achieved through a lookup table-based vector control strategy that adapts to inverter constraints. Rotor position is estimated using a hybrid approach combining a hyperbolic function-based super-twisting sliding mode observer, a hybrid second-third-order generalized integrator, and a pseudo-linear enhanced phase-locked loop. Simulation and experimental results show that the proposed method reduces chattering, eliminates DC offsets, and ensures accurate rotor position detection across varying back EMF levels, enhancing the drive system's efficiency and performance.
- 16 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (4) , 6513-6528
A Novel Sensor-Less Vector Controlled PMaSyRM Drive for Light Electric Vehicle Applications
This paper proposes a solar photovoltaic and battery-integrated drive system for light electric vehicles using a sensor-less vector-controlled permanent magnet-assisted synchronous reluctance motor (PMaSyRM). A bidirectional DC-DC converter supports regenerative braking and stabilizes the DC link voltage. Motor control is achieved through a lookup table-based vector control strategy that adapts to inverter constraints. Rotor position is estimated using a hybrid approach combining a hyperbolic function-based super-twisting sliding mode observer, a hybrid second-third-order generalized integrator, and a pseudo-linear enhanced phase-locked loop. Simulation and experimental results show that the proposed method reduces chattering, eliminates DC offsets, and ensures accurate rotor position detection across varying back EMF levels, enhancing the drive system's efficiency and performance.
- 13 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A SASNPA Algorithm based Robust Controller for 3-Phase Grid PV System
This paper presents a robust controller based on the sparse Andrew sin norms prompting adaptive (SASNPA) algorithm for 3-Phase grid-photo-voltaic (GPV) system. To limit the large error of voltage and current, an Andrew sin function (ASF) is used, along with a reweighted zero attracting (RZA) technique for reduction of number of equations. The complete controller is modeled in MATLAB-SIMULINK and applied on a 3-Phase grid connected solar photovoltaic (SPV) system for efficient transfer of available SPV power to the grid. Further, a comparative analysis of the proposed SASNPA algorithm based system and other existing controllers, is presented to demonstrate superiority of this controller. A scaled down laboratory hardware setup is also presented for validation of proposed concepts.
- 13 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A SASNPA Algorithm based Robust Controller for 3-Phase Grid PV System
This paper presents a robust controller based on the sparse Andrew sin norms prompting adaptive (SASNPA) algorithm for 3-Phase grid-photo-voltaic (GPV) system. To limit the large error of voltage and current, an Andrew sin function (ASF) is used, along with a reweighted zero attracting (RZA) technique for reduction of number of equations. The complete controller is modeled in MATLAB-SIMULINK and applied on a 3-Phase grid connected solar photovoltaic (SPV) system for efficient transfer of available SPV power to the grid. Further, a comparative analysis of the proposed SASNPA algorithm based system and other existing controllers, is presented to demonstrate superiority of this controller. A scaled down laboratory hardware setup is also presented for validation of proposed concepts.