Dulichand Jaraniya
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dulichand Jaraniya has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Shailendra Kumar
Department of Electrical Engineering, Indian Institute of Technology, Bhilai, India
4 shared publications - Bhim Singh
Indian Institute of Technology Delhi
2 shared publications - Gaurav Modi
Department of Electrical Engineering, Indian Institute of Technology, New Delhi, India
1 shared publication - Mukesh Kumar Kirar
Department of Electrical and Electronic Engineering, Maulana Azad National Institute of Technology, Bhopal, India
1 shared publication Shailendra Kumar
Maulana Azad National Institute of Technology
1 shared publication
Latest Publications
- 27 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (1) , 535-544
LMSTDE Control for Hybrid Charging Station With Ancillary Services Powered by Variable Speed Wind and PV Array Based Renewable Energy Resources
A hybrid wind/photovoltaic array based grid-tied charging station (CS) is presented in this article. The vector control scheme is used to control the turbine side converter. The grid side converter is controlled through an improved variable step-size (VSS) least mean square time difference estimation algorithm. In the presence of correlated Gaussian noise and a low signal-to-noise ratio, this technique performs good as compared to the conventional techniques. It consists of a VSS with an arctangent function of the correlated value of mean square error. Moreover, it involves a fourth-order cumulant, which improves the performance of the CS. The performance of MGCS is further improved due to its updated weights as it provides the facility of VSS. Moreover, cascaded control is incorporated to control the charging/discharging (C/D) operation of the electric vehicle battery and dc-link voltage regulation. This CS is capable to perform under dynamic conditions, such as variable wind speed, the presence or absence of wind and PV generation, load sudden change, reduced and absence of insolation, and change in C/D. These controls overall enhance the performance and reduce harmonic in the grid current which improves the power quality. The MGCS is validated by using OPAL-RT (OP5600) based experimental laboratory setup.
- 27 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (1) , 535-544
LMSTDE Control for Hybrid Charging Station With Ancillary Services Powered by Variable Speed Wind and PV Array Based Renewable Energy Resources
A hybrid wind/photovoltaic array based grid-tied charging station (CS) is presented in this article. The vector control scheme is used to control the turbine side converter. The grid side converter is controlled through an improved variable step-size (VSS) least mean square time difference estimation algorithm. In the presence of correlated Gaussian noise and a low signal-to-noise ratio, this technique performs good as compared to the conventional techniques. It consists of a VSS with an arctangent function of the correlated value of mean square error. Moreover, it involves a fourth-order cumulant, which improves the performance of the CS. The performance of MGCS is further improved due to its updated weights as it provides the facility of VSS. Moreover, cascaded control is incorporated to control the charging/discharging (C/D) operation of the electric vehicle battery and dc-link voltage regulation. This CS is capable to perform under dynamic conditions, such as variable wind speed, the presence or absence of wind and PV generation, load sudden change, reduced and absence of insolation, and change in C/D. These controls overall enhance the performance and reduce harmonic in the grid current which improves the power quality. The MGCS is validated by using OPAL-RT (OP5600) based experimental laboratory setup.
- 25 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. 60 (6) , 8494-8503
Meta-Heuristic Optimization and Variable Sparsity Combination of Two LMS Framework Based Charging Solutions for Electric Transportation
A grid tied hybrid charging station is developed to provide fast-charging. It is designed with incorporation of two framework adaptive filters, aiming to enhance power quality and detect variable sparsity in a multifunctional charging station. To regulate DC link voltage to desired level, a cascaded proportional-integral controller is utilized in conjunction with a bidirectional converter. Proportional-integral controller's parameters are optimized through a meta-heuristic swarm-based technique, with integral time square error as optimization criterion. This optimization ensures that proportional-integral controller delivers desired response. The efficacy of this proposed control is validated through both simulated and experimental laboratory prototype results.
- 25 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. 60 (6) , 8494-8503
Meta-Heuristic Optimization and Variable Sparsity Combination of Two LMS Framework Based Charging Solutions for Electric Transportation
A grid tied hybrid charging station is developed to provide fast-charging. It is designed with incorporation of two framework adaptive filters, aiming to enhance power quality and detect variable sparsity in a multifunctional charging station. To regulate DC link voltage to desired level, a cascaded proportional-integral controller is utilized in conjunction with a bidirectional converter. Proportional-integral controller's parameters are optimized through a meta-heuristic swarm-based technique, with integral time square error as optimization criterion. This optimization ensures that proportional-integral controller delivers desired response. The efficacy of this proposed control is validated through both simulated and experimental laboratory prototype results.
- 1 February 2023
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (2) , 2166-2177
PV Charging Station with VSS-IMSAF and SOSMCC Disturbance Observer Based Controls to Enhance the Distribution Grid Capability
This paper present a three-phase grid-tied (GT) charging station (CS) based on photovoltaic (PV) arrays. The purpose of the proposed CS is to support the distribution grid under heavy electric vehicles (EVs) loads with improved power quality. The variable step size improved multiband adaptive structured filter (VSS-IMSAF) technique is used to control voltage source converter (VSC). Due to the variable step size, the control regulates the grid currents and subjects to the proper step size selection to improve the performance of CS. Moreover, the charge/discharge operations of the electric vehicle battery (EVB) are also incorporated. For regulation of the DC bus voltage, second-order sliding mode cascaded control (SOSMCC) is used, which also controls the charge/discharge operations. The SOSMCC is equipped with the linear observer (LINO), second-order sliding mode observer (SOSMO), linear extended state observer (LESO), and nonlinear extended state observer (NESO), which reduce the overshoot, undershoot, and uncertainties in the voltage at DC link and EV battery current quickly and accurately. This charging station is also capable to operate under load unbalancing, unavailability and reduced insolation, and sudden change of the mode of operation (charging/discharging). The presented controls improve the performance of the CS and feed the reduced harmonic current to the grid under nonlinear load. The test results are presented using the OPAL-RT real-time simulator under various scenarios.
- 1 February 2023
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (2) , 2166-2177
PV Charging Station with VSS-IMSAF and SOSMCC Disturbance Observer Based Controls to Enhance the Distribution Grid Capability
This paper present a three-phase grid-tied (GT) charging station (CS) based on photovoltaic (PV) arrays. The purpose of the proposed CS is to support the distribution grid under heavy electric vehicles (EVs) loads with improved power quality. The variable step size improved multiband adaptive structured filter (VSS-IMSAF) technique is used to control voltage source converter (VSC). Due to the variable step size, the control regulates the grid currents and subjects to the proper step size selection to improve the performance of CS. Moreover, the charge/discharge operations of the electric vehicle battery (EVB) are also incorporated. For regulation of the DC bus voltage, second-order sliding mode cascaded control (SOSMCC) is used, which also controls the charge/discharge operations. The SOSMCC is equipped with the linear observer (LINO), second-order sliding mode observer (SOSMO), linear extended state observer (LESO), and nonlinear extended state observer (NESO), which reduce the overshoot, undershoot, and uncertainties in the voltage at DC link and EV battery current quickly and accurately. This charging station is also capable to operate under load unbalancing, unavailability and reduced insolation, and sudden change of the mode of operation (charging/discharging). The presented controls improve the performance of the CS and feed the reduced harmonic current to the grid under nonlinear load. The test results are presented using the OPAL-RT real-time simulator under various scenarios.
- 5 October 2022
- Published by Springer Nature
- p. 245-253
Grid Interactive PV System with Advanced Filtering Technique and PV Feed-Forward Loop
- 5 October 2022
- Published by Springer Nature
- p. 245-253
Grid Interactive PV System with Advanced Filtering Technique and PV Feed-Forward Loop
- 24 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Variable Sparsity Affine Combined Adaptive Control Technique for Grid Tied Three Phase Single Stage Charging Station
An affine combination of two adaptive filters (AFs) based control is developed for a three-phase single stage grid tied photo voltaic (PV) array and ultra-capacitor (UC) charging electric vehicle spot (CEVS) of a charging station (CS). This algorithm is a combination of low complexity normalized least mean square (NLMS) and improved sparse channel identification reweighted zero attracting-NLMS (RZA-NLMS) filters. This combination offers the variable sparsity identification and improves the power quality of the CS. This CS is capable of grid to vehicle (G2V), PV source to vehicle (S2V), PV source to grid (S2G) and PV source to home (S2H). This CS also incorporates the vehicle to grid (V2G) and vehicle to home (V2H) functions when solar generation is reduced due to cloud crossing or in night time and state of charge (SOC) of the battery is sufficient to discharge battery. The DC link voltage is regulated through a bidirectional converter (BDC) using a cascaded PI controller. To improve the stability of the BDC, the loop shaping method is used. The loop shaping method is incorporated using k-factor approach. The efficacy of CS is demonstrated through the simulated results using MATLAB Simulink Library.
- 24 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Variable Sparsity Affine Combined Adaptive Control Technique for Grid Tied Three Phase Single Stage Charging Station
An affine combination of two adaptive filters (AFs) based control is developed for a three-phase single stage grid tied photo voltaic (PV) array and ultra-capacitor (UC) charging electric vehicle spot (CEVS) of a charging station (CS). This algorithm is a combination of low complexity normalized least mean square (NLMS) and improved sparse channel identification reweighted zero attracting-NLMS (RZA-NLMS) filters. This combination offers the variable sparsity identification and improves the power quality of the CS. This CS is capable of grid to vehicle (G2V), PV source to vehicle (S2V), PV source to grid (S2G) and PV source to home (S2H). This CS also incorporates the vehicle to grid (V2G) and vehicle to home (V2H) functions when solar generation is reduced due to cloud crossing or in night time and state of charge (SOC) of the battery is sufficient to discharge battery. The DC link voltage is regulated through a bidirectional converter (BDC) using a cascaded PI controller. To improve the stability of the BDC, the loop shaping method is used. The loop shaping method is incorporated using k-factor approach. The efficacy of CS is demonstrated through the simulated results using MATLAB Simulink Library.