Christine W. Sindt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christine W. Sindt has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Jami R. Kern
2 shared publicationsAmy Watts
Ocular Surface Imaging Center, Cornea & Refractive Surgery Service, Massachusetts Eye & Ear Infirmary, Department of Ophthalmology, Boston, MA, USA
1 shared publication- Anam Akhlaq
Glaucoma Center of Excellence, Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA
1 shared publication - Andrea Cruzat
Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA
1 shared publication - Bernardo Menelau Cavalcanti
Ocular Surface Imaging Center, Cornea & Refractive Surgery Service, Massachusetts Eye & Ear Infirmary, Department of Ophthalmology, Boston, MA, USA
1 shared publication - Beth Ann Benetz
Department of Ophthalmology and Visual Sciences, Case Western Reserve University and University Hospitals Eye Institute, Cleveland, OH
1 shared publication
Latest Publications
- 20 June 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (6) , e70080
Influence of corneal endothelial cell density after penetrating keratoplasty on contact lens induced corneal swelling
Purpose: Substantial endothelial cell loss (∼80%) occurs after keratoplasty. Corneal rigid and scleral lenses are frequently prescribed to manage irregular astigmatism and high refractive error, but lens wear may contribute to hypoxic stress. The relationship between various lens wear and corneal stress after penetrating keratoplasty remains unclear. This study characterizes cell density distribution in post‐keratoplasty corneas and evaluates its influence on swelling during lens wear. Methods: Participants ≥5 years post‐surgery, with or without habitual lens wear, were enrolled. Specular microscopy measured endothelial cell density in central, superior, inferior, superotemporal, and superonasal corneal quadrants (@3 mm). Baseline corneal thickness maps (>2 h after waking without lens wear) were acquired using Scheimpflug imaging (Pentacam). Wearers applied habitual lenses and all participants returned 6–8 h later for imaging. Nonparametric tests assessed cell density variation by quadrant and lens designs. Linear mixed models evaluated associations between endothelial parameters and corneal swelling while accounting for within‐subject correlation, repeated measures, lens type, location, and interactions. Results: Twenty‐five participants (31 eyes) from three centers were included; 90% had keratoconus preoperatively. Four wore large‐diameter scleral lenses (13%), nine wore small‐diameter scleral lenses (29%), 12 wore corneal rigid lenses (39%), and six did not wear lenses (19%). Cell density across quadrants averaged 780 ± 240 cells/mm 2 . Central thickness decreased slightly in non‐lens‐wearing eyes (−0.3%) but increased in lens‐wearing eyes (1.9% ± 3.1%). Central cell density showed a weak negative correlation with swelling ( r = −0.39, p = 0.03). Compared with non‐lens wearers, corneal rigid ( p = 0.02) and large diameter scleral lenses ( p = 0.05) generated greater swelling; smaller diameter scleral lenses did not. Conclusions: Although all eyes fitted with various lens designs were clear, lower central cell density correlated with increased swelling during lens wear, except when smaller diameter scleral lenses were worn. Clinically, however, cell density does not seem to be a robust predictor of corneal swelling induced by lens wear post‐keratoplasty.
- 20 June 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (6) , e70080
Influence of corneal endothelial cell density after penetrating keratoplasty on contact lens induced corneal swelling
Purpose: Substantial endothelial cell loss (∼80%) occurs after keratoplasty. Corneal rigid and scleral lenses are frequently prescribed to manage irregular astigmatism and high refractive error, but lens wear may contribute to hypoxic stress. The relationship between various lens wear and corneal stress after penetrating keratoplasty remains unclear. This study characterizes cell density distribution in post‐keratoplasty corneas and evaluates its influence on swelling during lens wear. Methods: Participants ≥5 years post‐surgery, with or without habitual lens wear, were enrolled. Specular microscopy measured endothelial cell density in central, superior, inferior, superotemporal, and superonasal corneal quadrants (@3 mm). Baseline corneal thickness maps (>2 h after waking without lens wear) were acquired using Scheimpflug imaging (Pentacam). Wearers applied habitual lenses and all participants returned 6–8 h later for imaging. Nonparametric tests assessed cell density variation by quadrant and lens designs. Linear mixed models evaluated associations between endothelial parameters and corneal swelling while accounting for within‐subject correlation, repeated measures, lens type, location, and interactions. Results: Twenty‐five participants (31 eyes) from three centers were included; 90% had keratoconus preoperatively. Four wore large‐diameter scleral lenses (13%), nine wore small‐diameter scleral lenses (29%), 12 wore corneal rigid lenses (39%), and six did not wear lenses (19%). Cell density across quadrants averaged 780 ± 240 cells/mm 2 . Central thickness decreased slightly in non‐lens‐wearing eyes (−0.3%) but increased in lens‐wearing eyes (1.9% ± 3.1%). Central cell density showed a weak negative correlation with swelling ( r = −0.39, p = 0.03). Compared with non‐lens wearers, corneal rigid ( p = 0.02) and large diameter scleral lenses ( p = 0.05) generated greater swelling; smaller diameter scleral lenses did not. Conclusions: Although all eyes fitted with various lens designs were clear, lower central cell density correlated with increased swelling during lens wear, except when smaller diameter scleral lenses were worn. Clinically, however, cell density does not seem to be a robust predictor of corneal swelling induced by lens wear post‐keratoplasty.
- 20 August 2022
- Published by Elsevier in The Ocular Surface
- Vol. 26, 157-165
Density and distribution of dendritiform cells in the peripheral cornea of healthy subjects using in vivo confocal microscopy
- 20 August 2022
- Published by Elsevier in The Ocular Surface
- Vol. 26, 157-165
Density and distribution of dendritiform cells in the peripheral cornea of healthy subjects using in vivo confocal microscopy
- 1 May 2018
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 34 (3) , 231-236
Scleral Contact Lenses in an Academic Oculoplastics Clinic: Epidemiology and Emerging Considerations
Purpose: To describe the role and efficacy of scleral contact lenses (SCLs) in the treatment of progressive keratopathy in patients who have undergone periocular surgical procedures, to investigate the financial impact of these surgical interventions, and to demonstrate the role of oculoplastic surgery in improving scleral contact lens fit. Methods: A retrospective medical record review was performed to identify patients who both received SCLs and were examined by the oculoplastics service at the University of Iowa between January 1990 and December 2015. Inclusion criteria also required a minimum of 12 months of patient follow up after being fit with a SCL. The indication for SCL use, as well as clinical outcomes and cumulative relative value units (RVUs) of prior oculoplastic treatments and SCL therapy were recorded for each patient. Results: Six hundred and fifty-nine patients were fitted with SCLs at the authors’ institution during the 25-year study period, 43 of whom were examined by the oculoplastics service for reasons related to their SCL. Patients who were fitted for SCLs before (27 patients) or after (16 patients) evaluation in the oculoplastics clinic presented with a variety of corneal and periocular pathology. Corneal indications for SCLs in patients seen secondarily in the oculoplastics clinic included decreased corneal sensation (from CN V palsy or neurotrophic keratopathy), decreased corneal healing from limbal stem cell deficiency, exposure keratopathy, and keratoconjunctivitis sicca secondary to Sjogren’s syndrome or orbital radiation. Indications for oculoplastic clinic evaluation in current scleral lens patients included lagophthalmos, trichiasis, epiphora, cicatricial changes in the eyelids or fornices, and eyelid or eyebrow malposition affecting SCL centration. In all 27 patients, surgical intervention resulted in improved SCL centration. Sixteen patients (5 with CN VII palsy, 4 with CN V and CN VII palsy, 4 with neurotrophic keratitis, and 3 with cicatricial entropion) had progressive corneal decompensation despite primary oculoplastics procedures to protect the cornea and ultimately benefitted from SCL treatment secondarily. Fourteen of these 16 patients demonstrated an improved visual acuity of 1 line or more using SCLs. Procedures performed before referral for SCLs included tarsorrhaphies, gold weights, ectropion repair with lateral tarsal strip, retraction repair with spacer grafts, full-thickness skin grafts, cheek lifts, and punctal occlusion. The total RVUs of these procedures performed per patient were tabulated. The RVU range was 10.47–33.96 with an average of 19.5 RVUs (standard deviation = 9.4 RVUs) per patient. Conclusions: Scleral contact lenses may offer a useful alternative to stabilize the ocular surface, improve vision, and minimize the financial impact and morbidity of multiple periocular procedures in select patients with progressive keratopathy of varying etiologies. The therapeutic indications and utilization of SCLs are likely to increase in oculoplastic practices with optometric support, particularly in academic settings. Surgical correction of eyelid and eyebrow malposition, as well as epiphora, may also be useful adjunctive procedures to optimize SCL fit.
- 1 May 2018
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 34 (3) , 231-236
Scleral Contact Lenses in an Academic Oculoplastics Clinic: Epidemiology and Emerging Considerations
Purpose: To describe the role and efficacy of scleral contact lenses (SCLs) in the treatment of progressive keratopathy in patients who have undergone periocular surgical procedures, to investigate the financial impact of these surgical interventions, and to demonstrate the role of oculoplastic surgery in improving scleral contact lens fit. Methods: A retrospective medical record review was performed to identify patients who both received SCLs and were examined by the oculoplastics service at the University of Iowa between January 1990 and December 2015. Inclusion criteria also required a minimum of 12 months of patient follow up after being fit with a SCL. The indication for SCL use, as well as clinical outcomes and cumulative relative value units (RVUs) of prior oculoplastic treatments and SCL therapy were recorded for each patient. Results: Six hundred and fifty-nine patients were fitted with SCLs at the authors’ institution during the 25-year study period, 43 of whom were examined by the oculoplastics service for reasons related to their SCL. Patients who were fitted for SCLs before (27 patients) or after (16 patients) evaluation in the oculoplastics clinic presented with a variety of corneal and periocular pathology. Corneal indications for SCLs in patients seen secondarily in the oculoplastics clinic included decreased corneal sensation (from CN V palsy or neurotrophic keratopathy), decreased corneal healing from limbal stem cell deficiency, exposure keratopathy, and keratoconjunctivitis sicca secondary to Sjogren’s syndrome or orbital radiation. Indications for oculoplastic clinic evaluation in current scleral lens patients included lagophthalmos, trichiasis, epiphora, cicatricial changes in the eyelids or fornices, and eyelid or eyebrow malposition affecting SCL centration. In all 27 patients, surgical intervention resulted in improved SCL centration. Sixteen patients (5 with CN VII palsy, 4 with CN V and CN VII palsy, 4 with neurotrophic keratitis, and 3 with cicatricial entropion) had progressive corneal decompensation despite primary oculoplastics procedures to protect the cornea and ultimately benefitted from SCL treatment secondarily. Fourteen of these 16 patients demonstrated an improved visual acuity of 1 line or more using SCLs. Procedures performed before referral for SCLs included tarsorrhaphies, gold weights, ectropion repair with lateral tarsal strip, retraction repair with spacer grafts, full-thickness skin grafts, cheek lifts, and punctal occlusion. The total RVUs of these procedures performed per patient were tabulated. The RVU range was 10.47–33.96 with an average of 19.5 RVUs (standard deviation = 9.4 RVUs) per patient. Conclusions: Scleral contact lenses may offer a useful alternative to stabilize the ocular surface, improve vision, and minimize the financial impact and morbidity of multiple periocular procedures in select patients with progressive keratopathy of varying etiologies. The therapeutic indications and utilization of SCLs are likely to increase in oculoplastic practices with optometric support, particularly in academic settings. Surgical correction of eyelid and eyebrow malposition, as well as epiphora, may also be useful adjunctive procedures to optimize SCL fit.
- 1 August 2015
- Published by Elsevier in Journal of American Association for Pediatric Ophthalmology and Strabismus
- Vol. 19 (4) , e38
Correction of binocular diplopia with novel contact lens technology
- 1 August 2015
- Published by Elsevier in Journal of American Association for Pediatric Ophthalmology and Strabismus
- Vol. 19 (4) , e38
Correction of binocular diplopia with novel contact lens technology
- Open Access
- 1 August 2013
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 7, 1713-22
Efficacy of an artificial tear emulsion in patients with dry eye associated with meibomian gland dysfunction
Peer reviewed article authored by (Sindt CW, Foulks GN). Read article or submit your manuscript for publishing.
- 1 August 2013
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 7, 1713-22
Open AccessEfficacy of an artificial tear emulsion in patients with dry eye associated with meibomian gland dysfunction
Peer reviewed article authored by (Sindt CW, Foulks GN). Read article or submit your manuscript for publishing.
- 1 April 2013
- Published by Wolters Kluwer Health in Cornea
- Vol. 32 (4) , 460-465
Rapid Image Evaluation System for Corneal In Vivo Confocal Microscopy
To develop rapid image processing techniques for the objective analysis of corneal in vivo confocal micrographs. Perpendicular central corneal volume scans from healthy volunteers were obtained via laser in vivo confocal microscopy. The layer in each volume scan that contained the nerve plexus was detected by applying software operators to analyze image features on the basis of their size, shape, and contrast. Dendritic immune cells were detected in the nerve image on the basis of cellular size, lack of elongation, and brightness relative to the nerves. Images that were 20 μm anterior to the best nerve layer images were used for the analysis of epithelial wing cells; wing cell detection was based on extended regional minima and a watershed transformation. The software successfully detected the best nerve layer images in 15 scans from 15 eyes. Manual and automatic analyses were 81.8% in agreement for dendritic immune cells (for 11 cells in a representative image) and 94.4% in agreement for wing cells (for 466 cells in the image). Within 10 seconds per scan, the software calculated the number, mean length, and mean density of immune cells; the number, mean size, and mean density of wing cells; and the number and mean length of nerves. Factors defining the shape and position of cells and nerves also were available. The software rapidly and accurately analyzed the in vivo confocal micrographs of the healthy central corneas, yielding quantitative results to describe the nerves, dendritic immune cells, and wing cells.
- 1 April 2013
- Published by Wolters Kluwer Health in Cornea
- Vol. 32 (4) , 460-465
Rapid Image Evaluation System for Corneal In Vivo Confocal Microscopy
To develop rapid image processing techniques for the objective analysis of corneal in vivo confocal micrographs. Perpendicular central corneal volume scans from healthy volunteers were obtained via laser in vivo confocal microscopy. The layer in each volume scan that contained the nerve plexus was detected by applying software operators to analyze image features on the basis of their size, shape, and contrast. Dendritic immune cells were detected in the nerve image on the basis of cellular size, lack of elongation, and brightness relative to the nerves. Images that were 20 μm anterior to the best nerve layer images were used for the analysis of epithelial wing cells; wing cell detection was based on extended regional minima and a watershed transformation. The software successfully detected the best nerve layer images in 15 scans from 15 eyes. Manual and automatic analyses were 81.8% in agreement for dendritic immune cells (for 11 cells in a representative image) and 94.4% in agreement for wing cells (for 466 cells in the image). Within 10 seconds per scan, the software calculated the number, mean length, and mean density of immune cells; the number, mean size, and mean density of wing cells; and the number and mean length of nerves. Factors defining the shape and position of cells and nerves also were available. The software rapidly and accurately analyzed the in vivo confocal micrographs of the healthy central corneas, yielding quantitative results to describe the nerves, dendritic immune cells, and wing cells.
- Open Access
- 1 March 2012
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 6, 511-9
Dendritic immune cell densities in the central cornea associated with soft contact lens types and lens care solution types: a pilot study
Peer reviewed article authored by (Sindt CW, Grout TK, Critser DB, Kern JR, Meadows DL). Read article or submit your manuscript for publishing.
- 1 March 2012
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 6, 511-9
Open AccessDendritic immune cell densities in the central cornea associated with soft contact lens types and lens care solution types: a pilot study
Peer reviewed article authored by (Sindt CW, Grout TK, Critser DB, Kern JR, Meadows DL). Read article or submit your manuscript for publishing.
- Open Access
- 1 January 2012
- Published by Wiley in Journal of Ophthalmology
- Vol. 2012, 1-4
Effects of Fluorescein Staining on Laser In Vivo Confocal Microscopy Images of the Cornea
This study was designed to identify whether topical fluorescein, a common ophthalmic tool, affects laser in vivo confocal microscopy of the cornea, a tool with growing applications. Twenty-five eye care specialists were asked to identify presence or absence of fluorescein in 99 confocal micrographs of healthy corneas. Responses were statistically similar to guessing for the epithelium (48% ± 14% of respondents correct per image) and the subbasal nerve plexus (49% ± 11% correct), but results were less clear for the stroma. Dendritic immune cells were quantified in bilateral images from subjects who had been unilaterally stained with fluorescein. Density of dendritic immune cells was statistically similar between the unstained and contralateral stained eyes of 24 contact lens wearers () and of 10 nonwearers (). Overall, the results indicated that fluorescein staining did not interfere with laser confocal microscopy of corneal epithelium, subbasal nerves, or dendritic immune cells.- 1 January 2012
- Published by Wiley in Journal of Ophthalmology
- Vol. 2012, 1-4
Open AccessEffects of Fluorescein Staining on Laser In Vivo Confocal Microscopy Images of the Cornea
This study was designed to identify whether topical fluorescein, a common ophthalmic tool, affects laser in vivo confocal microscopy of the cornea, a tool with growing applications. Twenty-five eye care specialists were asked to identify presence or absence of fluorescein in 99 confocal micrographs of healthy corneas. Responses were statistically similar to guessing for the epithelium (48% ± 14% of respondents correct per image) and the subbasal nerve plexus (49% ± 11% correct), but results were less clear for the stroma. Dendritic immune cells were quantified in bilateral images from subjects who had been unilaterally stained with fluorescein. Density of dendritic immune cells was statistically similar between the unstained and contralateral stained eyes of 24 contact lens wearers () and of 10 nonwearers (). Overall, the results indicated that fluorescein staining did not interfere with laser confocal microscopy of corneal epithelium, subbasal nerves, or dendritic immune cells. - 1 January 2011
- Published by Elsevier in Optometry - Journal of the American Optometric Association
- Vol. 82 (1) , 44-45
Practitioner attitudes on children and contact lenses
- 1 January 2011
- Published by Elsevier in Optometry - Journal of the American Optometric Association
- Vol. 82 (1) , 44-45
Practitioner attitudes on children and contact lenses
- 30 June 2009
- Published by Elsevier in Optometry - Journal of the American Optometric Association
- Vol. 80 (6) , 287
Impact of Contact Lens Wear and Sodium Fluorescein Instillation on HRT Confocal Microscopy
- 30 June 2009
- Published by Elsevier in Optometry - Journal of the American Optometric Association
- Vol. 80 (6) , 287
Impact of Contact Lens Wear and Sodium Fluorescein Instillation on HRT Confocal Microscopy