Beth Ann Benetz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Beth Ann Benetz has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Abdus Sattar
Department of Population and Quantitative Health Sciences, School of Medicine, Case Western Reserve University, Cleveland, OH
1 shared publication Ariana Austin
Univ Calif San Francisco, Francis I Proctor Fdn, San Francisco, CA 94143 USA
1 shared publicationCharles C. Lin
Stanford Univ, Byers Eye Inst, Palo Alto, CA 94305 USA
1 shared publication- Christine W. Sindt
Department of Ophthalmology University of Iowa Iowa City Iowa USA
1 shared publication - Edward C. Parsons
CXL Ophthalmics, LLC, Encinitas, CA, USA
1 shared publication - Holly E. Hartman
CWRU Department of Population and Quantitative Health Sciences Cleveland Ohio USA
1 shared publication
Latest Publications
- 17 November 2026
- Published by Wolters Kluwer Health in Cornea
Keratoconus Severity and Relationship With Corneal Endothelial Morphology in a Multicenter, Randomized, Double-Masked, Sham-Controlled Phase 3 Study to Evaluate the Efficacy and Safety of Epithelium-On Corneal Crosslinking
Purpose: The aim of this study was to determine the correlation between corneal endothelial morphology and keratoconus tomographic disease severity. Methods: Two hundred fifty-four patients with keratoconus (477 eyes) in a phase 3 study of epithelium-on crosslinking underwent central endothelial specular microscopic imaging OU before treatment. Coefficient of variation (CV) and % of hexagonal cells (HEX) were determined by an image analysis reading center performing dual grading and adjudication. Associations of CV and HEX with Pentacam BAD display final “D,” anterior radius of curvature, minimal corneal thickness (MinCT), and posterior elevation at the thinnest point (PETP) were examined. Results: 66.9% were male and 33.1% were female. Final D and MinCT ranges were 0.17 to 30.58 and 354 to 585 μm, respectively. The mean (±SD) CV was 29.33 ± 4.05 and moderately positively correlated with age (r = 0.34, P < 0.01). CV showed statistically significant correlations with final D (r = −0.11, P = 0.02), ARC (r = 0.10, P = 0.03), and MinCT (r = 0.16, P < 0.01), while PETP was insignificant (r = −0.06, P = 0.19). CV improved (lower values) with increasing disease severity. The mean HEX ±SD was 63.05 ± 7.70 and negatively correlated with age (r = −0.35, P < 0.01) and MinCT (r = −0.09, P = 0.04). In contact lens–adjusted median regression models, CV remained significantly associated with age and tomographic severity measures, whereas age was the only factor associated with HEX. Conclusions: Age demonstrated the strongest and most consistent association with endothelial morphology, suggesting that morphologic changes are influenced more by aging than by keratoconus severity.
- 17 November 2026
- Published by Wolters Kluwer Health in Cornea
Keratoconus Severity and Relationship With Corneal Endothelial Morphology in a Multicenter, Randomized, Double-Masked, Sham-Controlled Phase 3 Study to Evaluate the Efficacy and Safety of Epithelium-On Corneal Crosslinking
Purpose: The aim of this study was to determine the correlation between corneal endothelial morphology and keratoconus tomographic disease severity. Methods: Two hundred fifty-four patients with keratoconus (477 eyes) in a phase 3 study of epithelium-on crosslinking underwent central endothelial specular microscopic imaging OU before treatment. Coefficient of variation (CV) and % of hexagonal cells (HEX) were determined by an image analysis reading center performing dual grading and adjudication. Associations of CV and HEX with Pentacam BAD display final “D,” anterior radius of curvature, minimal corneal thickness (MinCT), and posterior elevation at the thinnest point (PETP) were examined. Results: 66.9% were male and 33.1% were female. Final D and MinCT ranges were 0.17 to 30.58 and 354 to 585 μm, respectively. The mean (±SD) CV was 29.33 ± 4.05 and moderately positively correlated with age (r = 0.34, P < 0.01). CV showed statistically significant correlations with final D (r = −0.11, P = 0.02), ARC (r = 0.10, P = 0.03), and MinCT (r = 0.16, P < 0.01), while PETP was insignificant (r = −0.06, P = 0.19). CV improved (lower values) with increasing disease severity. The mean HEX ±SD was 63.05 ± 7.70 and negatively correlated with age (r = −0.35, P < 0.01) and MinCT (r = −0.09, P = 0.04). In contact lens–adjusted median regression models, CV remained significantly associated with age and tomographic severity measures, whereas age was the only factor associated with HEX. Conclusions: Age demonstrated the strongest and most consistent association with endothelial morphology, suggesting that morphologic changes are influenced more by aging than by keratoconus severity.
- 20 June 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (6) , e70080
Influence of corneal endothelial cell density after penetrating keratoplasty on contact lens induced corneal swelling
Purpose: Substantial endothelial cell loss (∼80%) occurs after keratoplasty. Corneal rigid and scleral lenses are frequently prescribed to manage irregular astigmatism and high refractive error, but lens wear may contribute to hypoxic stress. The relationship between various lens wear and corneal stress after penetrating keratoplasty remains unclear. This study characterizes cell density distribution in post‐keratoplasty corneas and evaluates its influence on swelling during lens wear. Methods: Participants ≥5 years post‐surgery, with or without habitual lens wear, were enrolled. Specular microscopy measured endothelial cell density in central, superior, inferior, superotemporal, and superonasal corneal quadrants (@3 mm). Baseline corneal thickness maps (>2 h after waking without lens wear) were acquired using Scheimpflug imaging (Pentacam). Wearers applied habitual lenses and all participants returned 6–8 h later for imaging. Nonparametric tests assessed cell density variation by quadrant and lens designs. Linear mixed models evaluated associations between endothelial parameters and corneal swelling while accounting for within‐subject correlation, repeated measures, lens type, location, and interactions. Results: Twenty‐five participants (31 eyes) from three centers were included; 90% had keratoconus preoperatively. Four wore large‐diameter scleral lenses (13%), nine wore small‐diameter scleral lenses (29%), 12 wore corneal rigid lenses (39%), and six did not wear lenses (19%). Cell density across quadrants averaged 780 ± 240 cells/mm 2 . Central thickness decreased slightly in non‐lens‐wearing eyes (−0.3%) but increased in lens‐wearing eyes (1.9% ± 3.1%). Central cell density showed a weak negative correlation with swelling ( r = −0.39, p = 0.03). Compared with non‐lens wearers, corneal rigid ( p = 0.02) and large diameter scleral lenses ( p = 0.05) generated greater swelling; smaller diameter scleral lenses did not. Conclusions: Although all eyes fitted with various lens designs were clear, lower central cell density correlated with increased swelling during lens wear, except when smaller diameter scleral lenses were worn. Clinically, however, cell density does not seem to be a robust predictor of corneal swelling induced by lens wear post‐keratoplasty.
- 20 June 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (6) , e70080
Influence of corneal endothelial cell density after penetrating keratoplasty on contact lens induced corneal swelling
Purpose: Substantial endothelial cell loss (∼80%) occurs after keratoplasty. Corneal rigid and scleral lenses are frequently prescribed to manage irregular astigmatism and high refractive error, but lens wear may contribute to hypoxic stress. The relationship between various lens wear and corneal stress after penetrating keratoplasty remains unclear. This study characterizes cell density distribution in post‐keratoplasty corneas and evaluates its influence on swelling during lens wear. Methods: Participants ≥5 years post‐surgery, with or without habitual lens wear, were enrolled. Specular microscopy measured endothelial cell density in central, superior, inferior, superotemporal, and superonasal corneal quadrants (@3 mm). Baseline corneal thickness maps (>2 h after waking without lens wear) were acquired using Scheimpflug imaging (Pentacam). Wearers applied habitual lenses and all participants returned 6–8 h later for imaging. Nonparametric tests assessed cell density variation by quadrant and lens designs. Linear mixed models evaluated associations between endothelial parameters and corneal swelling while accounting for within‐subject correlation, repeated measures, lens type, location, and interactions. Results: Twenty‐five participants (31 eyes) from three centers were included; 90% had keratoconus preoperatively. Four wore large‐diameter scleral lenses (13%), nine wore small‐diameter scleral lenses (29%), 12 wore corneal rigid lenses (39%), and six did not wear lenses (19%). Cell density across quadrants averaged 780 ± 240 cells/mm 2 . Central thickness decreased slightly in non‐lens‐wearing eyes (−0.3%) but increased in lens‐wearing eyes (1.9% ± 3.1%). Central cell density showed a weak negative correlation with swelling ( r = −0.39, p = 0.03). Compared with non‐lens wearers, corneal rigid ( p = 0.02) and large diameter scleral lenses ( p = 0.05) generated greater swelling; smaller diameter scleral lenses did not. Conclusions: Although all eyes fitted with various lens designs were clear, lower central cell density correlated with increased swelling during lens wear, except when smaller diameter scleral lenses were worn. Clinically, however, cell density does not seem to be a robust predictor of corneal swelling induced by lens wear post‐keratoplasty.
- 25 December 2020
- Published by Elsevier in Ophthalmology
- Vol. 128 (8) , 1238-1240
Descemet Endothelial Thickness Comparison Trial: Two-Year Results from a Randomized Trial Comparing Ultrathin Descemet Stripping Automated Endothelial Keratoplasty with Descemet Membrane Endothelial Keratoplasty
- 25 December 2020
- Published by Elsevier in Ophthalmology
- Vol. 128 (8) , 1238-1240
Descemet Endothelial Thickness Comparison Trial: Two-Year Results from a Randomized Trial Comparing Ultrathin Descemet Stripping Automated Endothelial Keratoplasty with Descemet Membrane Endothelial Keratoplasty