SHSimon. R. G. Hall

Simon. R. G. Hall

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Simon. R. G. Hall has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of Nanobridge Lithography Techniques for Nanoscale SQUID Devices

    by Jamie A. Potter, Gemma Chapman, Tom Godfrey, Laith Meti, Parth Bhandari, Olena Shaforost, John Gallop, Gustavo Trindade, Ian Gilmore, Christopher Chunnilall, et al.

    NanoSQUIDS incorporating nanobridges as the Josephson element are desirable since their small dimensions mean they can be situated in close proximity to very small, highly localised magnetic moments for high spin sensitivity. Key to achieving the necessary dimensions are the lithographic technologies used to fabricate the nanobridges. Here we present characterisation of Nb nanoSQUIDs incorporating nanobridges fabricated by three different techniques: neon focused ion beam (FIB) lithography, gallium FIB lithography and e-beam lithography (EBL). We discuss the critical currents and voltage-current characteristics achieved by each technique at various temperatures for a range of nanobridge widths, and discuss the corresponding nanoSQUID voltage modulation and potential applications.


  • Open Access

    Traceable characterisation of fibre-coupled single-photon detectors

    by Luke Arabskyj, Philip R Dolan, Adam L Parke, Ted S Santana, Simon R G Hall, Geiland Porrovecchio, Marek Smid, Marco Lucamarini, Christopher J Chunnilall

    The detection of single photons plays an essential role in advancing single-photon science and technologies. Yet, within the visible/near-infrared spectral region, accurate fibre-based optical power measurements at the few-photon level are not yet well-established. In this study, we report on a fibre-based setup, enabling traceable optical power measurements at the few-photon level in this spectral region. The setup was used to calibrate the detection efficiency (DE) of four single-photon avalanche diode (SPAD) detectors. The relative standard uncertainties on the mean DE values obtained from repeat fibre-to-detector couplings ranged from 0.67% to 0.81% (k = 2). However, the relative standard deviation of DE values, which ranged from 1.38% to 3.20% (k = 2), poses a challenge for the metrology of these devices and applications that require high accuracy and repeatability. We investigated the source of these variations by spatially mapping the response of a detector’s fibre connector port, using a focused free-space beam, allowing us to estimate the detector’s spatial non-uniformity. In addition, we realise a novel calibration approach for fibre-coupled SPADs in a free-space configuration, enabling a direct comparison between the fibre-based setup and the National Physical Laboratory’s established free-space facility using a single SPAD. Finally, we investigated alternative coupling methods, testing the repeatability of different fibre-to-fibre connectors in addition to direct fibre-to-detector couplings: SPADs from three manufacturers were tested, with both single-mode and multi-mode fibre.


  • Open Access

    Compressed Sensing Current Mapping Spatial Characterization of Photovoltaic Devices

    by George Koutsourakis, Matt Cashmore, Simon R. G. Hall, Martin Bliss, Thomas R. Betts, Ralph Gottschalg

    A new photovoltaic (PV) device current mapping method has been developed, combining the recently introduced compressed sensing (CS) sampling theory with light beam induced current (LBIC) measurements. Instead of a raster scan, compressive sampling is applied using a digital micromirror device. The aim is to significantly reduce the time required to produce a current map, compared to conventional LBIC measurements. This is achieved by acquiring fewer measurements than a full raster scan and by utilizing the fast response of the micromirror device to modulate measurement conditions. The method has been implemented on an optical current mapping setup built at the National Physical Laboratory, U.K. Measurements with two different PV cells are presented in this paper and an analytical description for realization of an optimized CS current mapping system is provided. The experimental results illustrate the feasibility of the method and its potential to significantly reduce measurement time of current mapping of PV devices.


  • Open Access

    Compressed sensing current mapping methods for PV characterisation

    by George Koutsourakis, Matt Cashmore, Martin Bliss, Simon R. G. Hall, Thomas R. Betts, Ralph Gottschalg

    The Compressed Sensing (CS) sampling theory has been combined with the Light Beam Induced Current (LBIC) method, to produce an alternative current mapping technique for photovoltaic (PV) devices. Compressive sampling of photocurrent is experimentally implemented using a Digital Micro-mirror Device (DMD). The main advantage of this new method for current mapping is that measurement time can be significantly reduced compared to conventional LBIC measurement systems. This is achieved mainly by acquiring fewer measurements than a raster scan would need and by utilizing the fast response of the micro-mirror array. Two different experimental layouts are considered in this work. The first is a small area optical set-up based on a single wavelength laser source. The second layout utilizes a commercial Digital Light Processing (DlP) projector through which compressive sampling is applied. Experimental results with both experimental schemes demonstrate that current maps can be produced with less than 50% of the measurements a standard LBIC system would need. The ability to acquire current maps of individual cells in encapsulated modules is also highlighted. The advantages and drawbacks of the method are presented and its potential to significantly reduce measurement time of current mapping of PV cells and modules is indicated.


  • Open Access

    Compressive Current Response Mapping of Photovoltaic Devices Using MEMS Mirror Arrays

    by Simon R. G. Hall, Matt Cashmore, John Blackburn, George Koutsourakis, Ralph Gottschalg

    Understanding the performance and aging mechanisms in photovoltaic devices requires a spatial assessment of the device properties. The current dominant technique, electroluminescence, has the disadvantage that it assesses radiative recombination only. A complementary method, laser beam-induced current (LBIC), is too slow for high-throughput measurements. This paper presents the description, design, and proof of concept of a new measurement method to significantly accelerate LBIC measurements. The method allows mapping of the current response map of solar cells and modules at drastically reduced acquisition times. This acceleration is achieved by projecting a number of mathematically derived patterns on the sample by using a digital micromirror device (DMD). The spatially resolved signal is then recovered using compressed sensing techniques. The system has fewer moving parts and is demonstrated to require fewer overall measurements. Compared with conventional LBIC imaging using galvanic mirror arrangements or xy scanners, the use of a DMD allows a significantly faster and more repeatable illumination of the device under test. In this proof-of-concept instrument, sampling patterns are drawn from Walsh-Hadamard matrices, which are one of the many operators that can be used to realize this technique. This has the advantage of the signal-to-noise ratio of the measurement being significantly increased and thus allows elimination of the standard lock-in techniques for signal detection, reducing measurement costs, and increasing measurement speed further. This new method has the potential to substantially decrease the time taken for measurement, which demonstrates a dramatic improvement in the utility of LBIC instrumentation.


  • Open Access

    Optical technique for photovoltaic spatial current response measurements using compressive sensing and random binary projections

    by Matt. T. Cashmore, George Koutsourakis, Ralph Gottschalg, Simon. R. G. Hall

    Compressive sensing has been widely used in image compression and signal recovery techniques in recent years; however, it has received limited attention in the field of optical measurement. This paper describes the use of compressive sensing for measurements of photovoltaic (PV) solar cells, using fully random sensing matrices, rather than mapping an orthogonal basis set directly. Existing compressive sensing systems optically image the surface of the object under test, this contrasts with the method described, where illumination patterns defined by precalculated sensing matrices, probe PV devices. We discuss the use of spatially modulated light fields to probe a PV sample to produce a photocurrent map of the optical response. This allows for faster measurements than would be possible using traditional translational laser beam induced current techniques. Results produced to a 90% correlation to raster scanned measurements, which can be achieved with under 25% of the conventionally required number of data points. In addition, both crack and spot type defects are detected at resolutions comparable to electroluminescence techniques, with 50% of the number of measurements required for a conventional scan.


  • LED-based field radiometer for sensor web in-situ measurements

    by Emanuele Taralli, Roberto Filippo, Giorgio Brida, Mauro Rajteri, Simon R.G. Hall, Agnieszka Bialek, Claire Greenwell, Nigel Fox

    We have developed a multi-band ground viewing radiometer based on light-emitting diodes (LEDs) to create a self-calibrating sensing system for land-based measurements. The system is intended for in-situ data collection needed for vicarious calibration, using the reflectance-based method, for earth observing satellites. An autonomous prototype radiometer, which is part of a sensor web of 5 radiometers which could be geographically distributed over hundreds of meters, has been realized. Temporally continuous in-situ measurement of the land reflectance in 4 spectral bands, from 350 nm to 900 nm, are acquired. The system has the ability to regularly re-calibrate autonomously and in the field, communicating results to a remote home base.


  • Traceable interferometry using binary reconfigurable holograms

    by M. T. Cashmore, S. R. G. Hall, G. D. Love

    We describe the characterization of a ferroelectric-liquid-crystal-on-silicon (FLCOS) spatial light modulator (SLM) in the production of holograms for use in interferometric metrology. It has already been shown that such a device can be used in producing small-amplitude arbitrary reference surfaces with small but appreciable errors due to the contaminating effect of higher-order structures being propagated through the spatial filter. Here we further quantify the size of these residuals for increasingly large aberrations up to nine waves rms Zernike astigmatism, showing a Zernike-corrected rms wavefront error of roughly 0.06 waves with high vibrational stability. We also present measurements of a vacuum window element using the FLCOS device to drastically reduce interferometric fringe density, showing a residual wavefront error of 0.046 waves rms with dominant components originating from test piece structure rather than holographic errors.


  • LED Junction Temperature Measurement Using Generated Photocurrent

    by Daren Alfred Lock, Simon R. G. Hall, A. D. Prins, B. G. Crutchley, S. Kynaston, Stephen John Sweeney

    LED-based lamps that are currently on the market are expensive due to the complex packaging required to dissipate the heat generated. This also limits their performance and lifetime due to the degradation of the phosphor or individual LED chips, in the case of RGB sources. There is a strong commercial imperative to develop in situ technology to measure and ultimately compensate for the thermal environment of a luminaire.


  • Novel software platform for advanced optical radiation safety analysis

    by Simon Hall, Neil Haigh

    This paper describes the development of a versatile software platform for the optical radiation safety based analysis of today’s generation of spectrally broad light sources such as the High Brightness light emitting diode (HB-LED), the intense pulsed lamp (IPL) and the Supercontinuum laser. The software is capable of implementing broadband source hazard analysis using the two main international standards for optical radiation safety, namely the IEC 60825 (‘laser’and IEC 62471 (‘lamp) series of standards, and allows the results of both analysis regimes to be compared with each other. Aside from its use as an investigative tool, the software also functions as a useful tutorial and training aid, allowing, for example, the user to explore the maximum permissible exposure limits in simultaneous dimensions of wavelength and time.