CCChristopher J. Chunnilall

Christopher J. Chunnilall

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christopher J. Chunnilall has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Cost-effective, rack-mountable energy-time/time-bin entangled biphoton source for quantum networks

    by Rong Xue, Christopher J. Chunnilall

    A quantum entanglement source distributing entangled photons to multiple users is an indispensable component of a quantum network. Furthermore, the development of affordable and easy-to-use entanglement sources can pave the way for widespread deployment of quantum networks. Here, a cost-effective, rack-mountable, fiber-based entanglement source in the telecom band has been developed. Based on second-order nonlinear optical processes in one periodically poled lithium niobate waveguide utilizing a reflection scheme, the source exhibited good signal-to-noise characteristics at high photon pair generation rates with a broadband spectrum covering the entire C-band and parts of the S-band and L-band. Three different wavelength-correlated energy-time and time-bin entangled photon pairs were demonstrated, whose entanglement properties were verified by measuring interference fringes with visibilities exceeding 96.5% for energy-time entanglement and 91.1% for time-bin entanglement. This source has great potential for implementing practical quantum networks and other scenarios.

  • Open Access

    Characterisation of a Low-Noise Tuneable Silicon Single-Photon Avalanche Diode

    by Luke Arabskyj, Liang Qiao, Dmitri Permogorov, Marco Lucamarini, Christopher Chunnilall

    Silicon single-photon avalanche diodes (Si-SPADs) are widely used in lightwave applications such as quantum communication, medical imaging, time-of-flight systems and quantum optical metrology, due to their sensitivity, accuracy, compactness and cost-effectiveness. The most important performance metric depends on its intended application. Each metric has a dependence on operating parameters such as bias voltage and operating temperature. Some metrics, e.g. detection efficiency and timing precision, exhibit performance trade-offs with noise. However, plug-and-play Si-SPADs typically have fixed bias voltage and operating temperature, which significantly limits user control, adaptability, and performance. In this study, a recently developed commercially available free-space Si-SPAD with adjustable bias voltage, temperature control, an integrated frequency counter and a large sensing area was evaluated. Key performance metrics were traceably measured as functions of bias voltage and temperature, including dark count rate, dead time, timing precision, afterpulse probability and photon detection efficiency at 852 nm. Results are benchmarked against existing reports of other commercially available Si-SPAD detectors. Notable strengths include low dark count rates (4 to 10 s-1), a large sensing area (diameter = 500 μm), and high timing precision (163 to 212ps), whilst maintaining a detection efficiency greater than 40%. These characteristics make the detector a strong candidate for deployment across a range of applications, particularly those operating outside of lab conditions where operational flexibility is essential.

  • Comparison of Nanobridge Lithography Techniques for Nanoscale SQUID Devices

    by Jamie A. Potter, Gemma Chapman, Tom Godfrey, Laith Meti, Parth Bhandari, Olena Shaforost, John Gallop, Gustavo Trindade, Ian Gilmore, Christopher Chunnilall, et al.

    NanoSQUIDS incorporating nanobridges as the Josephson element are desirable since their small dimensions mean they can be situated in close proximity to very small, highly localised magnetic moments for high spin sensitivity. Key to achieving the necessary dimensions are the lithographic technologies used to fabricate the nanobridges. Here we present characterisation of Nb nanoSQUIDs incorporating nanobridges fabricated by three different techniques: neon focused ion beam (FIB) lithography, gallium FIB lithography and e-beam lithography (EBL). We discuss the critical currents and voltage-current characteristics achieved by each technique at various temperatures for a range of nanobridge widths, and discuss the corresponding nanoSQUID voltage modulation and potential applications.


  • Open Access

    Interference effects in commercially available free-space silicon single-photon avalanche diodes

    by L. Arabskyj, B. Dejen, T. S. Santana, M. Lucamarini, C. J. Chunnilall, P. R. Dolan

    Single-photon avalanche diodes (SPADs) are essential for photon-based measurements and metrology, enabling measurement comparisons at the few-photon level and facilitating global traceability to the SI. A spatially uniform detector response is crucial for these applications. Here, we report on interference effects in commercially available silicon SPADs that are detrimental to their spatial uniformity. Contrasts as high as 18% are observed, posing problems for metrology and general applications that utilize coherent light and require stable detection efficiencies. We eliminate the device optical window as a contributing interface, isolating likely causes to anti-reflective coatings, the semiconductor surface, and the SPAD's internal structure. We also present results where we leverage this sub-optimal behavior by aligning an incident beam with the position of maximum constructive interference, yielding an effective detection efficiency of 51.1(1.7)% compared to the normal value of 44.3(1)% obtained with the interference suppressed. We anticipate that this work will significantly impact the continuing development of these devices, the methods for characterizing them, and their use in accurate measurements.


  • Open Access

    A refined method for characterizing afterpulse probability in single-photon avalanche diodes

    by B. Dejen, A. Vaquero-Stainer, T. S. Santana, L. Arabskyj, P. R. Dolan, C. J. Chunnilall

    Single-photon avalanche diodes (SPADs) are critical components in low-light-level sensing and photonic quantum information applications. For these, it is often necessary that a full characterization of the SPAD is performed, for which a key metric is the afterpulse probability. This study provides a detailed comparison of the common synchronized and non-synchronized methods used to measure afterpulse probability. Measurements on a single SPAD reveal inconsistencies between the afterpulse probabilities obtained by the two methods. By re-deriving the equations from first principles, the discrepancy is traced to the analysis approach for the non-synchronized experiment. An improved analysis approach is presented, leading to better agreement between the non-synchronized and synchronized methods. The study also provides guidance on the experimental conditions required for the valid application of both methods, along with a detailed analysis of the limitations of the non-synchronized method under high photon flux. These findings offer a more accurate approach for characterizing afterpulse probability and for reconciling the results of two methods, which enables better quantification of SPAD performance.


  • Open Access

    Traceable characterisation of fibre-coupled single-photon detectors

    by Luke Arabskyj, Philip R Dolan, Adam L Parke, Ted S Santana, Simon R G Hall, Geiland Porrovecchio, Marek Smid, Marco Lucamarini, Christopher J Chunnilall

    The detection of single photons plays an essential role in advancing single-photon science and technologies. Yet, within the visible/near-infrared spectral region, accurate fibre-based optical power measurements at the few-photon level are not yet well-established. In this study, we report on a fibre-based setup, enabling traceable optical power measurements at the few-photon level in this spectral region. The setup was used to calibrate the detection efficiency (DE) of four single-photon avalanche diode (SPAD) detectors. The relative standard uncertainties on the mean DE values obtained from repeat fibre-to-detector couplings ranged from 0.67% to 0.81% (k = 2). However, the relative standard deviation of DE values, which ranged from 1.38% to 3.20% (k = 2), poses a challenge for the metrology of these devices and applications that require high accuracy and repeatability. We investigated the source of these variations by spatially mapping the response of a detector’s fibre connector port, using a focused free-space beam, allowing us to estimate the detector’s spatial non-uniformity. In addition, we realise a novel calibration approach for fibre-coupled SPADs in a free-space configuration, enabling a direct comparison between the fibre-based setup and the National Physical Laboratory’s established free-space facility using a single SPAD. Finally, we investigated alternative coupling methods, testing the repeatability of different fibre-to-fibre connectors in addition to direct fibre-to-detector couplings: SPADs from three manufacturers were tested, with both single-mode and multi-mode fibre.


  • Extending the quantum tomography of a quasi-photon-number-resolving detector

    by Ted S. Santana, Christian Daniel Muñoz, Robert A. Starkwood, Christopher J. Chunnilall

    The ability to discriminate the number of photons in a radiation field has a critical role in the implementation of quantum optical technologies. True photon-number-resolving detectors are rare and complex devices, while a quasi-photon-number-resolving detector (qPNRD) is a practical alternative for real-world applications. Our qPNRD is composed of a fiber demultiplexer and individual non-photon-number-resolving detectors. We perform quantum tomography on our qPNRD based on the positive operator-valued measure and extend the analysis using the Bayesian formalism to uncover how the measurement influences knowledge of the measured photon probability distribution.


  • International standards development for quantum technologies (NPL representation and provision of technical expertise)

    by C Chunnilall, T Lindstrom, I Rungger, R Godun, O Kazakova, H Margolis, S Bhandari, I May, R Lewis

  • Traceable metrology for characterizing quantum optical communication devices

    by C J Chunnilall, G Lepert, J J Allerton, C J Hart, A G Sinclair