Michael F. Insana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michael F. Insana has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Hongmei Zhang
The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Western China Science and Technology Innovation Harbour, Xi'an, 712000, Shaanxi, PR China
5 shared publications - Craig K. Abbey
University of California, Santa Barbara, Department of Psychological and Brain Sciences, Santa Barbara, California, United States
4 shared publications - MinWoo Kim
Pusan National University
4 shared publications - Wawrzyniec Lawrence Dobrucki
University of Illinois at Urbana−Champaign
4 shared publications Craig K. Abbey
Department of Psychological and Brain Sciences, University of California, Santa Barbara, CA, USA
3 shared publicationsJamshid Ghaboussi
Grainger College of Engineering, Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign 3 , Urbana, Illinois 61801
3 shared publications
Latest Publications
- Open Access
- 1 March 2026
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 159 (3) , 2174-2188
Factors determining the quality of learned elastic-modulus images from ultrasonic measurements
The autoprogressive (AutoP) method forms images of the stress and material properties of tissues using surface force and internal displacement measurements from quasi-static compression experiments. The method combines measurements with finite-element analysis to obtain physically constrained stress-strain training data, which are used to train a neural network material model. Internal displacements must be acquired using a medical imaging modality to apply AutoP to medical tasks. Ultrasound (US) linear arrays are well-suited for two-dimensional displacement tracking, however, tissue deformation occurs in three-dimensional displacement tracking, and displacement quality is limited. This report employs gelatin phantoms to examine the key experimental variables that are responsible for determining image contrast, accuracy, and spatial resolution of elastic-modulus images formed using AutoP with measurements from US linear array transducers. The greatest degradation of image quality occurs with displacement errors and when displacement sampling does not extend over the volume of deformed media. Rather than producing the random noise patterns often observed in images, measurement errors reduce image contrast and spatial resolution. Losses are minimized by techniques that increase the information content of the training data at the cost of extending the training time.
- 1 March 2026
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 159 (3) , 2174-2188
Open AccessFactors determining the quality of learned elastic-modulus images from ultrasonic measurements
The autoprogressive (AutoP) method forms images of the stress and material properties of tissues using surface force and internal displacement measurements from quasi-static compression experiments. The method combines measurements with finite-element analysis to obtain physically constrained stress-strain training data, which are used to train a neural network material model. Internal displacements must be acquired using a medical imaging modality to apply AutoP to medical tasks. Ultrasound (US) linear arrays are well-suited for two-dimensional displacement tracking, however, tissue deformation occurs in three-dimensional displacement tracking, and displacement quality is limited. This report employs gelatin phantoms to examine the key experimental variables that are responsible for determining image contrast, accuracy, and spatial resolution of elastic-modulus images formed using AutoP with measurements from US linear array transducers. The greatest degradation of image quality occurs with displacement errors and when displacement sampling does not extend over the volume of deformed media. Rather than producing the random noise patterns often observed in images, measurement errors reduce image contrast and spatial resolution. Losses are minimized by techniques that increase the information content of the training data at the cost of extending the training time.
- Open Access
- 1 September 2024
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 5 (3) , 035066
Regulating the development of accurate data-driven physics-informed deformation models
The challenge posed by the inverse problem associated with ultrasonic elasticity imaging is well matched to the capabilities of data-driven solutions. This report describes how data properties and the time sequence by which the data are introduced during training influence deformation-model accuracy and training times. Our goal is to image the elastic modulus of soft linear-elastic media as accurately as possible within a limited volume. To monitor progress during training, we introduce metrics describing convergence rate and stress entropy to guide data acquisition and other timing features. For example, a regularization term in the loss function may be introduced and later removed to speed and stabilize developing deformation models as well as establishing stopping rules for neural-network convergence. Images of a 14.4 cm3 volume within 3D software phantom visually indicate the quality of modulus images resulting over a range of training variables. The results show that a data-driven method constrained by the physics of a deformed solid will lead to quantitively accurate 3D elastic modulus images with minimum artifacts.
- 1 September 2024
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 5 (3) , 035066
Open AccessRegulating the development of accurate data-driven physics-informed deformation models
The challenge posed by the inverse problem associated with ultrasonic elasticity imaging is well matched to the capabilities of data-driven solutions. This report describes how data properties and the time sequence by which the data are introduced during training influence deformation-model accuracy and training times. Our goal is to image the elastic modulus of soft linear-elastic media as accurately as possible within a limited volume. To monitor progress during training, we introduce metrics describing convergence rate and stress entropy to guide data acquisition and other timing features. For example, a regularization term in the loss function may be introduced and later removed to speed and stabilize developing deformation models as well as establishing stopping rules for neural-network convergence. Images of a 14.4 cm3 volume within 3D software phantom visually indicate the quality of modulus images resulting over a range of training variables. The results show that a data-driven method constrained by the physics of a deformed solid will lead to quantitively accurate 3D elastic modulus images with minimum artifacts.
- Open Access
- 21 May 2024
- Published by Elsevier in JVS-Vascular Insights
- Vol. 2
Facing the challenges of peripheral arterial disease in the era of emerging technologies
- 21 May 2024
- Published by Elsevier in JVS-Vascular Insights
- Vol. 2
Open AccessFacing the challenges of peripheral arterial disease in the era of emerging technologies
- Open Access
- 5 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2421-2431
Power-Doppler Ultrasonic Imaging of Peripheral Perfusion in Diabetic Mice
Objective: We explored the capabilities of power-Doppler ultrasonic (PD-US) imaging without contrast enhancement for monitoring changes in muscle perfusion over time. Methods: Ischemic recovery was observed in healthy and type II diabetic male and female mice with and without exercise. In separate studies, perfusion was measured during and after 5-min ischemic periods and during four-week recovery periods following irreversible femoral ligation. A goal was to assess how well PD-US estimates tracked the diabetic-related changes in endothelial function that influenced perfusion. Results: The average perfusion recovery time following femoral ligation increased 47% in diabetic males and 74% in diabetic females compared with non-diabetic mice. Flow-mediated dilation in conduit arteries and the reactive hyperemia index in resistive vessels each declined by one half in sedentary diabetic mice compared with sedentary non-diabetic mice. We found that exercise reduced the loss of endothelial function from diabetes in both sexes. The reproducibility of perfusion measurements was limited primarily by our ability to select the same region in muscle and to effectively filter tissue clutter. Conclusions/Significance: PD-US measurements can precisely follow site-specific changes in skeletal muscle perfusion related to diabetes over time, which fills the need for techniques capable of regularly monitoring atherosclerotic changes leading to ischemic vascular pathologies.
- 5 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2421-2431
Open AccessPower-Doppler Ultrasonic Imaging of Peripheral Perfusion in Diabetic Mice
Objective: We explored the capabilities of power-Doppler ultrasonic (PD-US) imaging without contrast enhancement for monitoring changes in muscle perfusion over time. Methods: Ischemic recovery was observed in healthy and type II diabetic male and female mice with and without exercise. In separate studies, perfusion was measured during and after 5-min ischemic periods and during four-week recovery periods following irreversible femoral ligation. A goal was to assess how well PD-US estimates tracked the diabetic-related changes in endothelial function that influenced perfusion. Results: The average perfusion recovery time following femoral ligation increased 47% in diabetic males and 74% in diabetic females compared with non-diabetic mice. Flow-mediated dilation in conduit arteries and the reactive hyperemia index in resistive vessels each declined by one half in sedentary diabetic mice compared with sedentary non-diabetic mice. We found that exercise reduced the loss of endothelial function from diabetes in both sexes. The reproducibility of perfusion measurements was limited primarily by our ability to select the same region in muscle and to effectively filter tissue clutter. Conclusions/Significance: PD-US measurements can precisely follow site-specific changes in skeletal muscle perfusion related to diabetes over time, which fills the need for techniques capable of regularly monitoring atherosclerotic changes leading to ischemic vascular pathologies.
- Open Access
- 1 August 2023
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 13 (8) , 4879-4896
Deep Q-learning to globally optimize a k-D parameter search for medical imaging
Background: Estimation of the global optima of multiple model parameters is valuable for precisely extracting parameters that characterize a physical environment. This is especially useful for imaging purposes, to form reliable, meaningful physical images with good reproducibility. However, it is challenging to avoid different local minima when the objective function is nonconvex. The problem of global searching of multiple parameters was formulated to be a k-D move in the parameter space and the parameter updating scheme was converted to be a state-action decision-making problem. Methods: We proposed a novel Deep Q-learning of Model Parameters (DQMP) method for global optimization which updated the parameter configurations through actions that maximized the Q-value and employed a Deep Reward Network (DRN) designed to learn global reward values from both visible fitting errors and hidden parameter errors. The DRN was constructed with Long Short-Term Memory (LSTM) layers followed by fully connected layers and a rectified linear unit (ReLU) nonlinearity. The depth of the DRN depended on the number of parameters. Through DQMP, the k-D parameter search in each step resembled the decision-making of action selections from 3k configurations in a k-D board game. Results: The DQMP method was evaluated by widely used general functions that can express a variety of experimental data and further validated on imaging applications. The convergence of the proposed DRN was evaluated, which showed that the loss values of six general functions all converged after 12 epochs. The parameters estimated by the DQMP method had relative errors of less than 4% for all cases, whereas the relative errors achieved by Q-learning (QL) and the Least Squares Method (LSM) were 17% and 21%, respectively. Furthermore, the imaging experiments demonstrated that the imaging of the parameters estimated by the proposed DQMP method were the closest to the ground truth simulation images when compared to other methods. Conclusions: The proposed DQMP method was able to achieve global optima, thus yielding accurate model parameter estimates. DQMP is promising for estimating multiple high-dimensional parameters and can be generalized to global optimization for many other complex nonconvex functions and imaging of physical parameters.
- 1 August 2023
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 13 (8) , 4879-4896
Open AccessDeep Q-learning to globally optimize a k-D parameter search for medical imaging
Background: Estimation of the global optima of multiple model parameters is valuable for precisely extracting parameters that characterize a physical environment. This is especially useful for imaging purposes, to form reliable, meaningful physical images with good reproducibility. However, it is challenging to avoid different local minima when the objective function is nonconvex. The problem of global searching of multiple parameters was formulated to be a k-D move in the parameter space and the parameter updating scheme was converted to be a state-action decision-making problem. Methods: We proposed a novel Deep Q-learning of Model Parameters (DQMP) method for global optimization which updated the parameter configurations through actions that maximized the Q-value and employed a Deep Reward Network (DRN) designed to learn global reward values from both visible fitting errors and hidden parameter errors. The DRN was constructed with Long Short-Term Memory (LSTM) layers followed by fully connected layers and a rectified linear unit (ReLU) nonlinearity. The depth of the DRN depended on the number of parameters. Through DQMP, the k-D parameter search in each step resembled the decision-making of action selections from 3k configurations in a k-D board game. Results: The DQMP method was evaluated by widely used general functions that can express a variety of experimental data and further validated on imaging applications. The convergence of the proposed DRN was evaluated, which showed that the loss values of six general functions all converged after 12 epochs. The parameters estimated by the DQMP method had relative errors of less than 4% for all cases, whereas the relative errors achieved by Q-learning (QL) and the Least Squares Method (LSM) were 17% and 21%, respectively. Furthermore, the imaging experiments demonstrated that the imaging of the parameters estimated by the proposed DQMP method were the closest to the ground truth simulation images when compared to other methods. Conclusions: The proposed DQMP method was able to achieve global optima, thus yielding accurate model parameter estimates. DQMP is promising for estimating multiple high-dimensional parameters and can be generalized to global optimization for many other complex nonconvex functions and imaging of physical parameters.
- 24 March 2023
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (6) , 1465-1475
Monitoring Muscle Perfusion in Rodents During Short-Term Ischemia Using Power Doppler Ultrasound
- 24 March 2023
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (6) , 1465-1475
Monitoring Muscle Perfusion in Rodents During Short-Term Ischemia Using Power Doppler Ultrasound
- Open Access
- 24 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (12) , 3243-3254
Combining Spatial Registration With Clutter Filtering for Power-Doppler Imaging in Peripheral Perfusion Applications
Power-Doppler ultrasonic (PD-US) imaging is sensitive to echoes from blood cell motion in the microvasculature but generally nonspecific because of difficulties with filtering nonblood-echo sources. We are studying the potential for using PD-US imaging for routine assessments of peripheral blood perfusion without contrast media. The strategy developed is based on an experimentally verified computational model of tissue perfusion that simulates typical in vivo conditions. The model considers directed and diffuse blood perfusion states in a field of moving clutter and noise. A spatial registration method is applied to minimize tissue motion prior to clutter and noise filtering. The results show that in-plane clutter motion is effectively minimized. While out-of-plane motion remains a strong source of clutter-filter leakage, those registration errors are readily minimized by straightforward modification of scanning techniques and spatial averaging.
- 24 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (12) , 3243-3254
Open AccessCombining Spatial Registration With Clutter Filtering for Power-Doppler Imaging in Peripheral Perfusion Applications
Power-Doppler ultrasonic (PD-US) imaging is sensitive to echoes from blood cell motion in the microvasculature but generally nonspecific because of difficulties with filtering nonblood-echo sources. We are studying the potential for using PD-US imaging for routine assessments of peripheral blood perfusion without contrast media. The strategy developed is based on an experimentally verified computational model of tissue perfusion that simulates typical in vivo conditions. The model considers directed and diffuse blood perfusion states in a field of moving clutter and noise. A spatial registration method is applied to minimize tissue motion prior to clutter and noise filtering. The results show that in-plane clutter motion is effectively minimized. While out-of-plane motion remains a strong source of clutter-filter leakage, those registration errors are readily minimized by straightforward modification of scanning techniques and spatial averaging.
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
A Data-Driven Approach to Characterizing Nonlinear Elastic Behavior of Soft Materials
The Autopregressive (AutoP) method is a data-driven inverse method that leverages finite element analysis (FEA) and machine learning (ML) techniques to build constitutive relationships from measured force and displacement data. Previous applications of AutoP in tissue-like media have focused on linear elastic mechanical behavior as the target object is infinitesimally compressed. In this study, we extended the application of AutoP in characterizing nonlinear elastic mechanical behavior as the target object undergoes finite compressive deformation. Guided by the prior of nonlinear media, we modified the training data generated by AutoP to speed its ability to learn to model deformations. AutoP training was validated using both synthetic and experimental data recorded from 3D objects. Force-displacement measurements were obtained using ultrasonic imaging from heterogeneous agar-gelatin phantoms. Measurement on samples of phantom components were analyzed to obtain independent measurements of material properties. Comparisons validated the material properties found from neural network constitutive models (NNCMs) trained using AutoP. Results were found to be robust to measurement errors and spatial variations in material properties.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Data-Driven Approach to Characterizing Nonlinear Elastic Behavior of Soft Materials
The Autopregressive (AutoP) method is a data-driven inverse method that leverages finite element analysis (FEA) and machine learning (ML) techniques to build constitutive relationships from measured force and displacement data. Previous applications of AutoP in tissue-like media have focused on linear elastic mechanical behavior as the target object is infinitesimally compressed. In this study, we extended the application of AutoP in characterizing nonlinear elastic mechanical behavior as the target object undergoes finite compressive deformation. Guided by the prior of nonlinear media, we modified the training data generated by AutoP to speed its ability to learn to model deformations. AutoP training was validated using both synthetic and experimental data recorded from 3D objects. Force-displacement measurements were obtained using ultrasonic imaging from heterogeneous agar-gelatin phantoms. Measurement on samples of phantom components were analyzed to obtain independent measurements of material properties. Comparisons validated the material properties found from neural network constitutive models (NNCMs) trained using AutoP. Results were found to be robust to measurement errors and spatial variations in material properties.
- 25 April 2020
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 19 (6) , 2163-2177
Fluidity and elasticity form a concise set of viscoelastic biomarkers for breast cancer diagnosis based on Kelvin–Voigt fractional derivative modeling
Cancer progression involves biomechanical changes within transformed cells and the surrounding extracellular matrix (ECM). The viscoelastic features of fluidity and elasticity that are based on a novel Kelvin–Voigt fractional derivative (KVFD) model were found capable of discriminating normal, benign and malignant breast biopsy tissues on the cellular scale. The improved specificity of KVFD model parameters derives from greater accuracy of fitting the entire approaching force-indentation measurement curve (\(R^{2}\) > 0.99) compared with traditional elastic models (\(R^{2}\) < 0.86). Moreover, model parameters can be interpreted in terms of histopathological features. First, statistical comparisons reveal there are significant differences (p < 0.001) in elasticity E0, fluidity \(\alpha\), and viscosity \(\tau\) among healthy, benign, and malignant groups. Malignant breast tissues show low-value, broad-distributions in E0 and with high fluidity \(\alpha\) as compared with healthy and benign tissues. Second, histograms of E0 and \(\alpha\) provide distinctive features by fitting to Gaussian mixture (GM) models. The histograms of E0 and \(\alpha\) are best fit by two kernels GM for malignant tissues, indicating that the cells are soft but with high fluidity and the ECM is stiff but with low fluidity. However, the data suggest one-kernel GM model for benign tissue and a patched uniform distribution for healthy tissue. Third, using fluidity \(\alpha\) as the test statistic, the area under the receiver operator characteristic curve (AUC) is 0.701 ± 0.012 (p < 0.0001) for control versus malignant and 0.706 ± 0.013 (p < 0.0001) for benign versus malignant group. Variations in tissue fluidity and elasticity offer a concise set of viscoelastic biomarkers that correlate well with histopathological features. Graphic abstract- 25 April 2020
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 19 (6) , 2163-2177
Fluidity and elasticity form a concise set of viscoelastic biomarkers for breast cancer diagnosis based on Kelvin–Voigt fractional derivative modeling
Cancer progression involves biomechanical changes within transformed cells and the surrounding extracellular matrix (ECM). The viscoelastic features of fluidity and elasticity that are based on a novel Kelvin–Voigt fractional derivative (KVFD) model were found capable of discriminating normal, benign and malignant breast biopsy tissues on the cellular scale. The improved specificity of KVFD model parameters derives from greater accuracy of fitting the entire approaching force-indentation measurement curve (\(R^{2}\) > 0.99) compared with traditional elastic models (\(R^{2}\) < 0.86). Moreover, model parameters can be interpreted in terms of histopathological features. First, statistical comparisons reveal there are significant differences (p < 0.001) in elasticity E0, fluidity \(\alpha\), and viscosity \(\tau\) among healthy, benign, and malignant groups. Malignant breast tissues show low-value, broad-distributions in E0 and with high fluidity \(\alpha\) as compared with healthy and benign tissues. Second, histograms of E0 and \(\alpha\) provide distinctive features by fitting to Gaussian mixture (GM) models. The histograms of E0 and \(\alpha\) are best fit by two kernels GM for malignant tissues, indicating that the cells are soft but with high fluidity and the ECM is stiff but with low fluidity. However, the data suggest one-kernel GM model for benign tissue and a patched uniform distribution for healthy tissue. Third, using fluidity \(\alpha\) as the test statistic, the area under the receiver operator characteristic curve (AUC) is 0.701 ± 0.012 (p < 0.0001) for control versus malignant and 0.706 ± 0.013 (p < 0.0001) for benign versus malignant group. Variations in tissue fluidity and elasticity offer a concise set of viscoelastic biomarkers that correlate well with histopathological features. Graphic abstract- 21 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (9) , 1830-1838
Experimental Validation of Perfusion Imaging With HOSVD Clutter Filters
Novel pulsed-Doppler methods for perfusion imaging are validated using dialysis cartridges as perfusion phantoms. Techniques that were demonstrated qualitatively at 24 MHz, in vivo, are here examined quantitatively at 5 and 12.5 MHz using phantoms with the blood-mimicking fluid flow within cellulose microfibers. One goal is to explore a variety of flow states to optimize measurement sensitivity and flow accuracy. The results show that 2-3-s echo acquisitions at roughly 10 frames/s yield the highest sensitivity to flows of 1-4 mL/min. A second goal is to examine methods for setting the parameters of higher order singular value decomposition (HOSVD) clutter filters. For stationary or moving clutter, the velocity of the blood-mimicking fluid in the microfibers is consistently estimated within measurement uncertainty (mean coefficient of variation = 0.26). Power Doppler signals were equivalent for stationary and moving clutter after clutter filtering, increasing approximately 3 dB/mL/min of blood-mimicking fluid flow for $0\leq {q}\leq 4$ mL/min. Comparisons between phantom and preclinical images show that peripheral perfusion imaging can be reliably achieved without contrast enhancement.- 21 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (9) , 1830-1838
Experimental Validation of Perfusion Imaging With HOSVD Clutter Filters
Novel pulsed-Doppler methods for perfusion imaging are validated using dialysis cartridges as perfusion phantoms. Techniques that were demonstrated qualitatively at 24 MHz, in vivo, are here examined quantitatively at 5 and 12.5 MHz using phantoms with the blood-mimicking fluid flow within cellulose microfibers. One goal is to explore a variety of flow states to optimize measurement sensitivity and flow accuracy. The results show that 2-3-s echo acquisitions at roughly 10 frames/s yield the highest sensitivity to flows of 1-4 mL/min. A second goal is to examine methods for setting the parameters of higher order singular value decomposition (HOSVD) clutter filters. For stationary or moving clutter, the velocity of the blood-mimicking fluid in the microfibers is consistently estimated within measurement uncertainty (mean coefficient of variation = 0.26). Power Doppler signals were equivalent for stationary and moving clutter after clutter filtering, increasing approximately 3 dB/mL/min of blood-mimicking fluid flow for $0\leq {q}\leq 4$ mL/min. Comparisons between phantom and preclinical images show that peripheral perfusion imaging can be reliably achieved without contrast enhancement.