Latest Publications
- 1 January 2025
- Published by Manufacturing Technologies and Applications in İmalat Teknolojileri ve Uygulamaları
- Vol. 6 (2) , 184-201
Numerical Investigation of the Effects of Using Nanofluid on Thermal Performance and Flow Properties in a Gyroid Structure Heat Exchanger
Recently, heat exchangers based on triply periodic minimal surface (TPMS) structures have attracted increasing interest in engineering applications due to their high surface-to-volume ratio, compact design, superior thermal performance, and the feasibility of manufacturing these complex geometries using additive manufacturing technologies. This study, the thermal performance and flow characteristics of a gyroid heat exchanger are numerically investigated using air-air and water-water based Al2O3 nanofluids as working fluids. Firstly, the numerical model for the air-air heat exchanger is validated against reference data from the literature for the hot fluid side, then thermal analysis was conducted for at different Recold numbers. As the Re increased, the heat transfer coefficient, heat transfer and Nusselt number increased. Subsequently, Al2O3 nanoparticles were added to the hot-side water base fluid at various volume concentrations (0%, 0.1%, 0.3%, 0.5%), and simulations were conducted under different Rehot-Recold combinations. It was observed that nanofluid concentration and Reynolds number affected the heat transfer coefficient, heat transfer rate, thermal efficiency and Nusselt number. In addition, a decrease in thermal efficiency was observed with the addition of 0-0.3% nanoparticles, followed by a slight increase between 0.3-0.5%. Studies examining the use of nanofluids in TPMS-gyroid structures are generally limited to heat sink applications; this study provides a contribution to the literature by investigating the effect of nanofluids in a compact cross-flow heat exchanger with simultaneous hot and cold fluid provided.
- 1 January 2025
- Published by Manufacturing Technologies and Applications in İmalat Teknolojileri ve Uygulamaları
- Vol. 6 (2) , 184-201
Numerical Investigation of the Effects of Using Nanofluid on Thermal Performance and Flow Properties in a Gyroid Structure Heat Exchanger
Recently, heat exchangers based on triply periodic minimal surface (TPMS) structures have attracted increasing interest in engineering applications due to their high surface-to-volume ratio, compact design, superior thermal performance, and the feasibility of manufacturing these complex geometries using additive manufacturing technologies. This study, the thermal performance and flow characteristics of a gyroid heat exchanger are numerically investigated using air-air and water-water based Al2O3 nanofluids as working fluids. Firstly, the numerical model for the air-air heat exchanger is validated against reference data from the literature for the hot fluid side, then thermal analysis was conducted for at different Recold numbers. As the Re increased, the heat transfer coefficient, heat transfer and Nusselt number increased. Subsequently, Al2O3 nanoparticles were added to the hot-side water base fluid at various volume concentrations (0%, 0.1%, 0.3%, 0.5%), and simulations were conducted under different Rehot-Recold combinations. It was observed that nanofluid concentration and Reynolds number affected the heat transfer coefficient, heat transfer rate, thermal efficiency and Nusselt number. In addition, a decrease in thermal efficiency was observed with the addition of 0-0.3% nanoparticles, followed by a slight increase between 0.3-0.5%. Studies examining the use of nanofluids in TPMS-gyroid structures are generally limited to heat sink applications; this study provides a contribution to the literature by investigating the effect of nanofluids in a compact cross-flow heat exchanger with simultaneous hot and cold fluid provided.
- 30 April 2022
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 42 (1) , 123-140
DESIGN FIRE CURVE SELECTION OF SMALL SCALE POOL FIRES IN A SCALED METRO STATION
N-heptane pool fire was numerically and experimentally investigated in a 1:100 scaled metro station. Fire Dynamics Simulator (FDS v6.7.5) has been applied to investigate smoke and temperature distribution by implementing different design curves in the station. Experimental and numerical studies were performed for 10 ml n-heptane fuel under zero piston effect. To develop performance-based design and to obtain reliable fire simulation results for structures, reasonable input conditions are essential for numerical studies. The aim of the study is to select most suitable fire design curve and make the numerical study independent of the experimental results for small scale hydrocarbon pool fires. In this study, t2, tanh, Eurocode 1 (BS EN 1991-1-2), exponential, and quadratic fire curves were investigated and validated with experimental results. The numerical results obtained using FDS were validated with experimental data and good agreement was observed for all design fire curves except quadratic one. It was observed that the exponential design fire curve predicted more similarly to the experimental data over the fire duration including growth, fully developed and decay phases. Regardless of the experimental results, it was seen that the temperature distribution results obtained from the numerical study using exponential fire design curve and the radiation / turbulence parameters obtained from the literature were found to have an average of 5% difference with the experimental results. It was also seen that the t2 and tanh curves have acceptable differences of 6.92% and 9.02%, respectively, and the Eurocode HC is less suitable than the other curves with a difference of 12.17%. Therefore, it can be said that in small scale hydrocarbon pool fires, fire design can be done using exponential design curve.
- 30 April 2022
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 42 (1) , 123-140
DESIGN FIRE CURVE SELECTION OF SMALL SCALE POOL FIRES IN A SCALED METRO STATION
N-heptane pool fire was numerically and experimentally investigated in a 1:100 scaled metro station. Fire Dynamics Simulator (FDS v6.7.5) has been applied to investigate smoke and temperature distribution by implementing different design curves in the station. Experimental and numerical studies were performed for 10 ml n-heptane fuel under zero piston effect. To develop performance-based design and to obtain reliable fire simulation results for structures, reasonable input conditions are essential for numerical studies. The aim of the study is to select most suitable fire design curve and make the numerical study independent of the experimental results for small scale hydrocarbon pool fires. In this study, t2, tanh, Eurocode 1 (BS EN 1991-1-2), exponential, and quadratic fire curves were investigated and validated with experimental results. The numerical results obtained using FDS were validated with experimental data and good agreement was observed for all design fire curves except quadratic one. It was observed that the exponential design fire curve predicted more similarly to the experimental data over the fire duration including growth, fully developed and decay phases. Regardless of the experimental results, it was seen that the temperature distribution results obtained from the numerical study using exponential fire design curve and the radiation / turbulence parameters obtained from the literature were found to have an average of 5% difference with the experimental results. It was also seen that the t2 and tanh curves have acceptable differences of 6.92% and 9.02%, respectively, and the Eurocode HC is less suitable than the other curves with a difference of 12.17%. Therefore, it can be said that in small scale hydrocarbon pool fires, fire design can be done using exponential design curve.
- 30 April 2022
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 42 (1) , 37-48
MEME VE KARACİĞER DOKULARINDA TEK VE ÇİFT YUVALI ANTEN KULLANILARAK YAPILAN MİKRODALGA KANSER TEDAVİSİNİN NÜMERİK ANALİZİ
Mikrodalga tedavisi, meme ve karaciğer kanseri gibi hastalıklarda, kanserli hücreleri yok etmek için cerrahi müdahale ihtiyacını ortadan kaldırabilen etkili bir yöntemdir. Mevcut çalışma, malign hücrelerin daha geniş bir çevrede, daha kısa sürede yakılırken çevre dokulara en az hasara sebep olmayı amaçlayan bir metodoloji sunmaı hedeflemektedir. Bu çalışma, 2.45 GHz frekans ve 10 W güç değeri kullanılarak sonlu eleman metoduyla gerçekleştirilmiştir. Meme ve karaciğer dokularında, eş eksenli tek yuvalı ve çift yuvalı antenler için bir kıyaslama sunulmuştur. Araştırılan parametreler yuva sayısı, doku tipi ve mikrodalga kanser tedavisinin süresi iken sonuçta incelenen parametreler özgül soğrulma oranı ve sıcaklık dağılımıdır. Çalışmanın sonucunda, hem en yüksek özgül soğrulma oranı hem de en yüksek sıcaklık değeri, karaciğerde tek yuvalı antenle elde edilmiştir ve elde edilen sıcaklık dağılımının zamana bağlı olduğu görülmüştür. Karaciğerde elde edilen en yüksek sıcaklık değeri, tek yuvalı antende 93.9oC ve çift yuvalı antende 82.8 oC olmuştur. Aynı değerler meme dokusunda, tek yuvalı antende 93.0 oC ve çift yuvalı antende 69.8 oC olarak kaydedilmiştir. Tek yuvalı anten için, karaciğer ve meme dokularının tedavisinde kullanılmak üzere yeni korelasyonlar sunulmuştur. Yapılan çalışmanın, tıp alanında katkı sağlaması beklenmektedir.
- 30 April 2022
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 42 (1) , 37-48
MEME VE KARACİĞER DOKULARINDA TEK VE ÇİFT YUVALI ANTEN KULLANILARAK YAPILAN MİKRODALGA KANSER TEDAVİSİNİN NÜMERİK ANALİZİ
Mikrodalga tedavisi, meme ve karaciğer kanseri gibi hastalıklarda, kanserli hücreleri yok etmek için cerrahi müdahale ihtiyacını ortadan kaldırabilen etkili bir yöntemdir. Mevcut çalışma, malign hücrelerin daha geniş bir çevrede, daha kısa sürede yakılırken çevre dokulara en az hasara sebep olmayı amaçlayan bir metodoloji sunmaı hedeflemektedir. Bu çalışma, 2.45 GHz frekans ve 10 W güç değeri kullanılarak sonlu eleman metoduyla gerçekleştirilmiştir. Meme ve karaciğer dokularında, eş eksenli tek yuvalı ve çift yuvalı antenler için bir kıyaslama sunulmuştur. Araştırılan parametreler yuva sayısı, doku tipi ve mikrodalga kanser tedavisinin süresi iken sonuçta incelenen parametreler özgül soğrulma oranı ve sıcaklık dağılımıdır. Çalışmanın sonucunda, hem en yüksek özgül soğrulma oranı hem de en yüksek sıcaklık değeri, karaciğerde tek yuvalı antenle elde edilmiştir ve elde edilen sıcaklık dağılımının zamana bağlı olduğu görülmüştür. Karaciğerde elde edilen en yüksek sıcaklık değeri, tek yuvalı antende 93.9oC ve çift yuvalı antende 82.8 oC olmuştur. Aynı değerler meme dokusunda, tek yuvalı antende 93.0 oC ve çift yuvalı antende 69.8 oC olarak kaydedilmiştir. Tek yuvalı anten için, karaciğer ve meme dokularının tedavisinde kullanılmak üzere yeni korelasyonlar sunulmuştur. Yapılan çalışmanın, tıp alanında katkı sağlaması beklenmektedir.
- 30 December 2021
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 7 (Supp 14) , 1885-1897
Bio-heat transfer in cancer treatment using cryo-freezing method
The objective of this study is to investigate the effect of bio-heat transfer from large blood vessels on freezing region size of tumorous liver tissue using cryo-freezing method. Bio-heat transfer, one of the cancer treatment method, in tumorous tissue has been investigated experimentally using cryo-freezing method for vessels. Investigated parameters are the blood mass flow rate, the diameter of vessel, the number of vessel, and the location of tumorous tissue. Study is carried out for nine different blood mass flow rates varying from 10 g/min to 1200 g/min. Tissues without blood vessel, with single, double and branched vessels are used for the experimental study. Vessels with inner diameter of 2.4, 3.2 and 4.0 mm are used. Liver of beef is employed as a tissue. Refrigerant is the nitrogen protoxide gas. Results show that the number of vessel, the diameter of vessel, the location of tumorous tissue, and the blood mass flow rate affect the freezing region size. Freezing region size decreases with increasing in diameter of vessel, number of vessel and blood mass flow rate. The large blood vessel located near the tumorous tissue affects the freezing time to destroy the tumor. The desired freezing region obtained in tumorous tissue with vessel develops later than the tumorous tissue without vessel. Results indicate that a tumorous tissue about 23 mm may be destroyed in a short time using cryo-freezing method when nitrogen protoxide gas is used as refrigerant gas.
- 30 December 2021
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 7 (Supp 14) , 1885-1897
Bio-heat transfer in cancer treatment using cryo-freezing method
The objective of this study is to investigate the effect of bio-heat transfer from large blood vessels on freezing region size of tumorous liver tissue using cryo-freezing method. Bio-heat transfer, one of the cancer treatment method, in tumorous tissue has been investigated experimentally using cryo-freezing method for vessels. Investigated parameters are the blood mass flow rate, the diameter of vessel, the number of vessel, and the location of tumorous tissue. Study is carried out for nine different blood mass flow rates varying from 10 g/min to 1200 g/min. Tissues without blood vessel, with single, double and branched vessels are used for the experimental study. Vessels with inner diameter of 2.4, 3.2 and 4.0 mm are used. Liver of beef is employed as a tissue. Refrigerant is the nitrogen protoxide gas. Results show that the number of vessel, the diameter of vessel, the location of tumorous tissue, and the blood mass flow rate affect the freezing region size. Freezing region size decreases with increasing in diameter of vessel, number of vessel and blood mass flow rate. The large blood vessel located near the tumorous tissue affects the freezing time to destroy the tumor. The desired freezing region obtained in tumorous tissue with vessel develops later than the tumorous tissue without vessel. Results indicate that a tumorous tissue about 23 mm may be destroyed in a short time using cryo-freezing method when nitrogen protoxide gas is used as refrigerant gas.
- Open Access
- 1 December 2021
- Published by Gazi University Journal of Science in Gazi University Journal of Science
- Vol. 34 (4) , 1107-1126
Flow and Heat Transfer in a Trapezoidal Cross-Sectional Microchannel Heat Sink Using Nanofluid
In this study, the effects of microchannel number, volume concentration, Reynolds number, and nanofluid type on heat transfer and flow characteristics in the heat sink consisting of trapezoidal microchannels are investigated numerically. Governing equations are solved by assuming three-dimensional, incompressible, steady and laminar flow. The channel material is chosen as copper, and a constant heat flux boundary condition is defined on the upper wall of heat sink. For two different nanofluids, CuO-water and Al2O3-water, investigated parameters are the number of trapezoidal channels (n=3-5) in the heat sink, Reynolds number (Re=200-1500), and volume concentration (=0-4%). Results show that using nanoparticles in base fluid causes to increase both heat transfer coefficient and pressure drop. Heat transfer coefficient increases with increasing number of trapezoidal cross-sectional channel in the heat sink, nanofluid volume concentration and Reynolds number. Pressure drop enhances with enhancing Reynolds number and microchannel number in the heat sink. The nanofluid type and volume concentration do not importantly affect the friction factor. According to the performance index, it is seen that adding CuO nanoparticles in water is convenient, but Al2O3 nanoparticles in water is not appropriate. It is observed that volume concentration for CuO-water nanofluid affects the thermal performance, but volume concentration for Al2O3-water nanofluid does not affect.
- 1 December 2021
- Published by Gazi University Journal of Science in Gazi University Journal of Science
- Vol. 34 (4) , 1107-1126
Open AccessFlow and Heat Transfer in a Trapezoidal Cross-Sectional Microchannel Heat Sink Using Nanofluid
In this study, the effects of microchannel number, volume concentration, Reynolds number, and nanofluid type on heat transfer and flow characteristics in the heat sink consisting of trapezoidal microchannels are investigated numerically. Governing equations are solved by assuming three-dimensional, incompressible, steady and laminar flow. The channel material is chosen as copper, and a constant heat flux boundary condition is defined on the upper wall of heat sink. For two different nanofluids, CuO-water and Al2O3-water, investigated parameters are the number of trapezoidal channels (n=3-5) in the heat sink, Reynolds number (Re=200-1500), and volume concentration (=0-4%). Results show that using nanoparticles in base fluid causes to increase both heat transfer coefficient and pressure drop. Heat transfer coefficient increases with increasing number of trapezoidal cross-sectional channel in the heat sink, nanofluid volume concentration and Reynolds number. Pressure drop enhances with enhancing Reynolds number and microchannel number in the heat sink. The nanofluid type and volume concentration do not importantly affect the friction factor. According to the performance index, it is seen that adding CuO nanoparticles in water is convenient, but Al2O3 nanoparticles in water is not appropriate. It is observed that volume concentration for CuO-water nanofluid affects the thermal performance, but volume concentration for Al2O3-water nanofluid does not affect.
- 1 December 2021
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 24 (4) , 1593-1604
A Comparison of Circular Duct and Real Hexagonal Duct Results Using Hydraulic Diameter
To see whether the turbulent flow correlations derived for circular ducts can be used for hexagonal cross-sectional ducts using hydraulic diameter, turbulent flow in hexagonal ducts is numerically investigated under constant wall temperature boundary condition using ANSYS Fluent 17.0 software. Investigated parameters are the Reynolds number between 10x10(3)<= Re <= 50x10(3) and side angle of the duct varying between 30 degrees and 90 degrees. Standard k-epsilon model is used as turbulence model. General expressions are proposed for fully developed dimensionless heat transfer coefficient Nusselt number and fully developed Darcy friction factor in terms of Reynolds number and side angle for hexagonal-shaped cross-sectional duct. Results show that side angle of hexagonal duct affects the pressure drop along duct and heat transfer coefficient in duct. Results point out that regular hexagonal duct, theta=60 degrees, gives minimum pressure drop and maximum Nusselt number. It is concluded that correlations given in the literature for circular ducts in turbulent flow can give 14% higher dimensionless heat transfer coefficient, Nusselt number, than that of actual hexagonal duct flow.
- 1 December 2021
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 24 (4) , 1593-1604
A Comparison of Circular Duct and Real Hexagonal Duct Results Using Hydraulic Diameter
To see whether the turbulent flow correlations derived for circular ducts can be used for hexagonal cross-sectional ducts using hydraulic diameter, turbulent flow in hexagonal ducts is numerically investigated under constant wall temperature boundary condition using ANSYS Fluent 17.0 software. Investigated parameters are the Reynolds number between 10x10(3)<= Re <= 50x10(3) and side angle of the duct varying between 30 degrees and 90 degrees. Standard k-epsilon model is used as turbulence model. General expressions are proposed for fully developed dimensionless heat transfer coefficient Nusselt number and fully developed Darcy friction factor in terms of Reynolds number and side angle for hexagonal-shaped cross-sectional duct. Results show that side angle of hexagonal duct affects the pressure drop along duct and heat transfer coefficient in duct. Results point out that regular hexagonal duct, theta=60 degrees, gives minimum pressure drop and maximum Nusselt number. It is concluded that correlations given in the literature for circular ducts in turbulent flow can give 14% higher dimensionless heat transfer coefficient, Nusselt number, than that of actual hexagonal duct flow.
- 1 January 2021
- Published by Begell House Inc. Publishers in Heat Transfer Research
- Vol. 52 (9) , 17-33
WIND-RELATED HEAT TRANSFER FROM TRIANGULAR AND TRAPEZOIDAL FLAT-PLATE COLLECTORS FLUSH MOUNTED ON THE ROOF OF A HOUSE
Forced convection heat transfer over surfaces of triangular and trapezoidal flat-plate collectors flush mounted on the roof of a residential house is investigated both experimentally and numerically for full-scale and 1:200 scale model collectors. Mass transfer experiments are performed by employing the naphthalene sublimation technique while numerical study is carried out using the ANSYS Fluent 17.0 software. The examined parameters are the roof tilt angle and the yaw angle of the house, Reynolds number, and the type of the collector. The results are given in terms of heat transfer parameters by employing the analogy between heat and mass transfer. It is seen that experimental and numerical results are in good agreement with each other in the Reynolds number range of the wind tunnel. The obtained results show that the heat transfer coefficient depends on the roof tilt angle and the yaw angle of the house, Reynolds number, and the type of the collector. It is seen that the heat transfer coefficient increases by changing the roof tilt angle from 25° to 45° and it also increases with increasing Reynolds number. In addition, the results exhibit that maximum heat loss occurs when the collector is in windward orientation. General expressions are given for windward and leeward orientations in the full-scale Reynolds number range. All the experimental and numerical results are correlated within an accuracy of ± 10% and ± 15%, respectively. It is seen that extrapolation of the results of 1:200 scale model to full scale gives incorrect results for full scale.
- 1 January 2021
- Published by Begell House Inc. Publishers in Heat Transfer Research
- Vol. 52 (9) , 17-33
WIND-RELATED HEAT TRANSFER FROM TRIANGULAR AND TRAPEZOIDAL FLAT-PLATE COLLECTORS FLUSH MOUNTED ON THE ROOF OF A HOUSE
Forced convection heat transfer over surfaces of triangular and trapezoidal flat-plate collectors flush mounted on the roof of a residential house is investigated both experimentally and numerically for full-scale and 1:200 scale model collectors. Mass transfer experiments are performed by employing the naphthalene sublimation technique while numerical study is carried out using the ANSYS Fluent 17.0 software. The examined parameters are the roof tilt angle and the yaw angle of the house, Reynolds number, and the type of the collector. The results are given in terms of heat transfer parameters by employing the analogy between heat and mass transfer. It is seen that experimental and numerical results are in good agreement with each other in the Reynolds number range of the wind tunnel. The obtained results show that the heat transfer coefficient depends on the roof tilt angle and the yaw angle of the house, Reynolds number, and the type of the collector. It is seen that the heat transfer coefficient increases by changing the roof tilt angle from 25° to 45° and it also increases with increasing Reynolds number. In addition, the results exhibit that maximum heat loss occurs when the collector is in windward orientation. General expressions are given for windward and leeward orientations in the full-scale Reynolds number range. All the experimental and numerical results are correlated within an accuracy of ± 10% and ± 15%, respectively. It is seen that extrapolation of the results of 1:200 scale model to full scale gives incorrect results for full scale.
- 1 June 2020
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 23 (2) , 567-579
The Effect of Turbulence Model and Nanofluid on Fluid Flow and Heat Transfer in a Narrow Rectangular Duct
The effect of turbulence model and nanofluid on the heat transfer and fluid flow in a horizontal narrow rectangular duct is numerically studied under constant wall heat flux boundary condition. Numerical study is carried out using ANSYS Fluent 17.0 software. Examined parameters are the type of turbulence model, the type of nanofluid, the volume fraction of nanofluid, and the Reynolds number. Three different k-e and four different k-w turbulence models are employed. Aluminum oxide Al2O3-water and copper oxide CuO-water are used as nanofluids. Volume fractions of nanoparticles used are 0%, 0.1%, 0.5%, 1%, 2% and 4%. Reynolds number changes from 3×103 to 50×103. Results showed that k-ω standard turbulence model with low Reynolds number correction gives better result. It is seen that both the type and volume fraction of nanofluid affect heat transfer and pressure drop. Using Al2O3 and CuO nanoparticles in water increases thermal performance. It is found that the performance of CuO-water nanofluid is better than that of Al2O3-water nanofluid. It is seen that using turbulent fully developed correlations derived for circular ducts may end up with incorrect results for the flow in a two dimensional rectangular duct.
- 1 June 2020
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 23 (2) , 567-579
The Effect of Turbulence Model and Nanofluid on Fluid Flow and Heat Transfer in a Narrow Rectangular Duct
The effect of turbulence model and nanofluid on the heat transfer and fluid flow in a horizontal narrow rectangular duct is numerically studied under constant wall heat flux boundary condition. Numerical study is carried out using ANSYS Fluent 17.0 software. Examined parameters are the type of turbulence model, the type of nanofluid, the volume fraction of nanofluid, and the Reynolds number. Three different k-e and four different k-w turbulence models are employed. Aluminum oxide Al2O3-water and copper oxide CuO-water are used as nanofluids. Volume fractions of nanoparticles used are 0%, 0.1%, 0.5%, 1%, 2% and 4%. Reynolds number changes from 3×103 to 50×103. Results showed that k-ω standard turbulence model with low Reynolds number correction gives better result. It is seen that both the type and volume fraction of nanofluid affect heat transfer and pressure drop. Using Al2O3 and CuO nanoparticles in water increases thermal performance. It is found that the performance of CuO-water nanofluid is better than that of Al2O3-water nanofluid. It is seen that using turbulent fully developed correlations derived for circular ducts may end up with incorrect results for the flow in a two dimensional rectangular duct.
- 1 January 2020
- Published by Begell House Inc. Publishers in Heat Transfer Research
- Vol. 51 (10) , 909-923
RADIANT CEILING COOLING CHARACTERISTICS AND THERMAL COMFORT FOR OFFICE ROOMS
Radiant ceiling cooling systems are used for both thermal comfort condition and energy saving due to the higher supply temperatures with respect to the classical air ventilation systems. In this paper, the characteristics of radiant ceiling cooling system and thermal comfort conditions have been investigated numerically. A three-dimensional mathematical model is simulated using ANSYS Fluent 17.0. Heat transfer in the concrete panel and typical office room is studied. The examined parameters are the pipe configuration type, supply velocity, and supply temperature. Thermal comfort conditions are examined for an office room with one person and two persons. Numerical results are validated with the literature results, and the results are found to be consistent with each other. The results show that a labyrinth pipe configuration gives better comfort conditions than a spiral pipe configuration. Proper values of supply velocity and temperature for the labyrinth pipe configuration are found as 0.49 m/s and 14°C, respectively.
- 1 January 2020
- Published by Begell House Inc. Publishers in Heat Transfer Research
- Vol. 51 (10) , 909-923
RADIANT CEILING COOLING CHARACTERISTICS AND THERMAL COMFORT FOR OFFICE ROOMS
Radiant ceiling cooling systems are used for both thermal comfort condition and energy saving due to the higher supply temperatures with respect to the classical air ventilation systems. In this paper, the characteristics of radiant ceiling cooling system and thermal comfort conditions have been investigated numerically. A three-dimensional mathematical model is simulated using ANSYS Fluent 17.0. Heat transfer in the concrete panel and typical office room is studied. The examined parameters are the pipe configuration type, supply velocity, and supply temperature. Thermal comfort conditions are examined for an office room with one person and two persons. Numerical results are validated with the literature results, and the results are found to be consistent with each other. The results show that a labyrinth pipe configuration gives better comfort conditions than a spiral pipe configuration. Proper values of supply velocity and temperature for the labyrinth pipe configuration are found as 0.49 m/s and 14°C, respectively.