Umut Barış YILMAZ
Research Subjects
Umut Barış YILMAZ has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Oğuz Turgut
Gazi Üniversitesi
2 shared publications - Muhammed İlter Berberoğlu
Turkish Aerospace Industry
1 shared publication - Nuri Yucel
Gazi Üniversitesi
1 shared publication
Latest Publications
- 30 April 2022
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 42 (1) , 123-140
DESIGN FIRE CURVE SELECTION OF SMALL SCALE POOL FIRES IN A SCALED METRO STATION
N-heptane pool fire was numerically and experimentally investigated in a 1:100 scaled metro station. Fire Dynamics Simulator (FDS v6.7.5) has been applied to investigate smoke and temperature distribution by implementing different design curves in the station. Experimental and numerical studies were performed for 10 ml n-heptane fuel under zero piston effect. To develop performance-based design and to obtain reliable fire simulation results for structures, reasonable input conditions are essential for numerical studies. The aim of the study is to select most suitable fire design curve and make the numerical study independent of the experimental results for small scale hydrocarbon pool fires. In this study, t2, tanh, Eurocode 1 (BS EN 1991-1-2), exponential, and quadratic fire curves were investigated and validated with experimental results. The numerical results obtained using FDS were validated with experimental data and good agreement was observed for all design fire curves except quadratic one. It was observed that the exponential design fire curve predicted more similarly to the experimental data over the fire duration including growth, fully developed and decay phases. Regardless of the experimental results, it was seen that the temperature distribution results obtained from the numerical study using exponential fire design curve and the radiation / turbulence parameters obtained from the literature were found to have an average of 5% difference with the experimental results. It was also seen that the t2 and tanh curves have acceptable differences of 6.92% and 9.02%, respectively, and the Eurocode HC is less suitable than the other curves with a difference of 12.17%. Therefore, it can be said that in small scale hydrocarbon pool fires, fire design can be done using exponential design curve.
- 30 April 2022
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 42 (1) , 123-140
DESIGN FIRE CURVE SELECTION OF SMALL SCALE POOL FIRES IN A SCALED METRO STATION
N-heptane pool fire was numerically and experimentally investigated in a 1:100 scaled metro station. Fire Dynamics Simulator (FDS v6.7.5) has been applied to investigate smoke and temperature distribution by implementing different design curves in the station. Experimental and numerical studies were performed for 10 ml n-heptane fuel under zero piston effect. To develop performance-based design and to obtain reliable fire simulation results for structures, reasonable input conditions are essential for numerical studies. The aim of the study is to select most suitable fire design curve and make the numerical study independent of the experimental results for small scale hydrocarbon pool fires. In this study, t2, tanh, Eurocode 1 (BS EN 1991-1-2), exponential, and quadratic fire curves were investigated and validated with experimental results. The numerical results obtained using FDS were validated with experimental data and good agreement was observed for all design fire curves except quadratic one. It was observed that the exponential design fire curve predicted more similarly to the experimental data over the fire duration including growth, fully developed and decay phases. Regardless of the experimental results, it was seen that the temperature distribution results obtained from the numerical study using exponential fire design curve and the radiation / turbulence parameters obtained from the literature were found to have an average of 5% difference with the experimental results. It was also seen that the t2 and tanh curves have acceptable differences of 6.92% and 9.02%, respectively, and the Eurocode HC is less suitable than the other curves with a difference of 12.17%. Therefore, it can be said that in small scale hydrocarbon pool fires, fire design can be done using exponential design curve.
- 1 December 2021
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 24 (4) , 1593-1604
A Comparison of Circular Duct and Real Hexagonal Duct Results Using Hydraulic Diameter
To see whether the turbulent flow correlations derived for circular ducts can be used for hexagonal cross-sectional ducts using hydraulic diameter, turbulent flow in hexagonal ducts is numerically investigated under constant wall temperature boundary condition using ANSYS Fluent 17.0 software. Investigated parameters are the Reynolds number between 10x10(3)<= Re <= 50x10(3) and side angle of the duct varying between 30 degrees and 90 degrees. Standard k-epsilon model is used as turbulence model. General expressions are proposed for fully developed dimensionless heat transfer coefficient Nusselt number and fully developed Darcy friction factor in terms of Reynolds number and side angle for hexagonal-shaped cross-sectional duct. Results show that side angle of hexagonal duct affects the pressure drop along duct and heat transfer coefficient in duct. Results point out that regular hexagonal duct, theta=60 degrees, gives minimum pressure drop and maximum Nusselt number. It is concluded that correlations given in the literature for circular ducts in turbulent flow can give 14% higher dimensionless heat transfer coefficient, Nusselt number, than that of actual hexagonal duct flow.
- 1 December 2021
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 24 (4) , 1593-1604
A Comparison of Circular Duct and Real Hexagonal Duct Results Using Hydraulic Diameter
To see whether the turbulent flow correlations derived for circular ducts can be used for hexagonal cross-sectional ducts using hydraulic diameter, turbulent flow in hexagonal ducts is numerically investigated under constant wall temperature boundary condition using ANSYS Fluent 17.0 software. Investigated parameters are the Reynolds number between 10x10(3)<= Re <= 50x10(3) and side angle of the duct varying between 30 degrees and 90 degrees. Standard k-epsilon model is used as turbulence model. General expressions are proposed for fully developed dimensionless heat transfer coefficient Nusselt number and fully developed Darcy friction factor in terms of Reynolds number and side angle for hexagonal-shaped cross-sectional duct. Results show that side angle of hexagonal duct affects the pressure drop along duct and heat transfer coefficient in duct. Results point out that regular hexagonal duct, theta=60 degrees, gives minimum pressure drop and maximum Nusselt number. It is concluded that correlations given in the literature for circular ducts in turbulent flow can give 14% higher dimensionless heat transfer coefficient, Nusselt number, than that of actual hexagonal duct flow.