KSKarim Ghazikhanlou Sani

Karim Ghazikhanlou Sani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Karim Ghazikhanlou Sani has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Radiation-induced Testicular Damage in Mice: Protective Effects of Apigenin Revealed by Histopathological Evaluation

    by Rasool Azmoonfar, Fatemeh Mirzaei, Masoud Najafi, Maryam Varkeshi, Karim Ghazikhanlousani, Sara Momeni, Korosh Saber

    Background: Radiation exposure poses a significant threat to reproductive health, particularly the male reproductive system. The testes, being highly sensitive to radiation, are susceptible to damage that can impair fertility and overall reproductive function. The study aims to investigate the radioprotective effects of apigenin on the testis through histopathological evaluation. Materials and Methods: This research involved utilizing a total of 40 mice, which were randomly divided into eight groups of five mice each. The groups were categorized as follows: A) negative control group, B, C, and D) administration of apigenin at three different doses (0.3 mg/kg, 0.6 mg/kg, and 1.2 mg/kg) respectively, E) irradiation group, and F, H, and I) administration of apigenin at three different doses (0.3 mg/kg, 0.6 mg/kg, and 1.2 mg/kg) in combination with irradiation. The irradiation procedure involved exposing the mice to a 2Gy X-ray throughout their entire bodies. Subsequently, histopathological assessments were conducted seven days after the irradiation process. Results: The findings indicated that radiation exposure significantly impacted the spermatogenesis system. This research provides evidence that administering apigenin to mice before ionizing radiation effectively mitigated the harmful effects on the testes. Apigenin demonstrated radioprotective properties, positively influencing various parameters, including the spermatogenesis process and the presence of inflammatory cells within the tubular spaces. Conclusion: Apigenin can provide effective protection for spermatogenesis, minimize the adverse effects of ionizing radiation, and safeguard normal tissues.


  • Open Access

    Image Findings and Radiation Dose in Lung CT Scan of Patients With COVID-19 in Hamadan

    by Salman Jafari, Faeze Heidari, Mahdi Asgari, Karim Ghazikhanlou Sani, Hossein Khosravi, Reza Afzalipour

    Background: Computed tomography (CT) scan plays an important role in the diagnosis of the COVID-19. Lung involvement appears in different forms on CT images. Absorbed dose to the patients may exceed diagnostic reference levels. This study aimed to investigate clinical symptoms, findings of lung CT scan, and absorbed dose to the patients. Methods: This cross-sectional descriptive study was conducted in two CT scan centers in Hamadan: Besat and Sina. CT images of 163 patients with positive real-time polymerase chain reaction (PCR) tests were interpreted by six experienced radiologists. Volume CT dose index (CTDIvol), dose length product (DLP), and effective dose were calculated in both centers and compared using the Mann-Whitney statistical test. Results: The most common findings in the CT images were ground-glass opacification (GGO), consolidation, and the combination of GGO and consolidation. CTDIvol, DLP, and effective dose to the patients were respectively 1.64±5.24 mGy, 177.12±59.03 mGy.cm, and 3.01±1.00 mSv in Sina hospital and 4.58±1.91 mGy, and 2.60±1.02 mSv in Besat hospital. The difference between quantities in the two centers was statistically significant (P>0.05). Conclusion: The most common findings in lung CT images of patients with positive polymerase chain reaction (PCR) tests were GGO and consolidation. Furthermore, there were differences in radiation dose to patients between hospitals, indicating the need for optimization.

  • Open Access

    The COVID-19 Pandemic's Impact on the Anxiety of Radiographers in Kermanshah, Iran

    by Saleh Salehi-Zahabi, Karim Ghazikhanlou, Kasra Talebi, Zahra Cheraghi, Maryam Veismorady

    Background: The emerging COVID-19 virus in the world has resulted in psychological concerns and issues, including anxiety, which in turn causes problems in both mental and physical dimensions in people; In the meantime, it is necessary to study the anxiety of health staff, especially radiographers, who are at the forefront of dealing patients with suspected corona disease. Objectives: To evaluate how the COVID-19 epidemic has affected the anxiety levels of radiographers in Kermanshah, Iran, examining the factors contributing to heightened anxiety and proposing potential strategies for mitigation. Methods: In this cross-sectional study, which employed a descriptive-analytical approach and a readily available sampling method, 102 radiographers who worked in various hospital wards in western Iran's educational and medical centers participated. The Corona Disease Anxiety Scale (CDAS) was the instrument used to collect the data. Results: According to the presented scores, 13 participants (12.7%) had no anxiety or mild mental anxiety, 75 participants (73.5%) had moderate mental anxiety, and 13 participants (12.7%) had severe mental anxiety. 87 participants (85.3%) had moderate physical anxiety, and 15 participants (14.7%) had severe physical anxiety. Conclusions: Radiographers' anxiety should be taken into account, as it can have adverse effects on their mental and physical well-being. It is crucial to prioritize the health of hospital staff and prevent any decrease in the efficiency of radiographers.

  • Open Access

    Investigating the Compatibility of Lung CT Scan Findings and Molecular Diagnosis Test of Patients With COVID-19 in Shahid Beheshti Hospital in Hamedan

    by Hossein Khosravi, Karim Qazi Khanlousani, Lavin Khorshidi, Younes Mohammadi

    Background: This study aimed to investigate the diagnostic value of computed tomography (CT) scan based on the results of reverse transcription polymerase chain reaction (RT-PCR) molecular diagnosis test in the diagnosis of COVID-19 diseases. Methods: In this study, 451 files related to hospitalized patients with initial diagnosis of COVID-19 were examined. Demographic information, symptoms, and results of both tests were extracted from the files. After collecting information by sampling method, the data were analyzed by SPSS software. In order to describe the data, mean and standard deviation statistics were used for qualitative data. Moreover, the Kappa test was used to measure the compatibility of the three methods. Results: The concordance rate of PCR and CT scan was calculated at 66%, of which 55.3% were positive, and 10.7% were negative. The results were obtained with an accuracy of 68.9%, a precision of 91.5%, a sensitivity of 69.1%, a specificity of 68%, and an F1-score of 95.10%. In general, based on the statistical criteria, the calculated percentage is an acceptable value. Conclusion: According to the appropriate matching percentage of CT scan and RT-PCR molecular diagnosis test, both techniques can be used as a diagnosis criterion according to the patient’s symptoms.

  • Evaluation of risk management status in selected departments of educational hospitals of Hamadan University of Medical Sciences

    by Ali Mohammadpour, Hamid Bouraghi, Taleb Khodaveisi, Behzad Imani, Karim Ghazikhanlousani, Rasool Azmoonfar, Hossein Khosravi, Hassan Rafieemehr

    BACKGROUND: Healthcare organizations are among high-risk organizations due to the nature of their work as well as structural, physical and technological complexities. Accordingly, it is very important to use risk management and control programs in all departments of these organizations. OBJECTIVE: The present study was conducted for the first time to evaluate the risk management status of the operating room and laboratory departments of Hamadan hospitals in 2022. METHODS: In this descriptive-observational cross-sectional study, laboratory and operating room departments were selected as the research environment. To conduct this research, a valid and reliable questionnaire was used to collect data, and the data were analyzed using the SPSS 22 statistical software. RESULTS: The findings of the present study showed that the overall mean score of risk management status for the laboratory and operating room departments was 2.66 ± 0.15 and 2.89 ± 0.13, respectively. Furthermore, there was no statistically significant difference in the mean scores of the research components based on work experience, education level, and gender. CONCLUSION: It is suggested that the laboratory and operating room departments should focus more on adopting policies and solutions to improve the position of risk management, training and budget allocation for risk management.


  • Open Access

    Comparison of Two Cone-Beam Computed Tomography Systems Regarding Linear Measurement Accuracy for Implant Sites in the Mandible: An In-Vitro Study

    by Amir Eskandarloo, Abbas Shokri, Aydin Salehi Milani, Mohammad Reza Jamalpoor, Karim Ghazikhanlou-Sani


  • Exposure of rats to extremely low-frequency electromagnetic fields (ELF-EMF) alters cytokines production

    by Iraj Salehi, Karim Ghazikhanlou Sani, Alireza Zamani

    Investigations indicate a potential link between exposure to extremely low-frequency electromagnetic field (ELF-EMF) and some cancers. Carcinogenesis of ELF-EMF may be mediated by effect on the immune system. During an immune response, naïve T cells differentiate to effector type 1 helper T cells (TH1), TH2, or TH17 subsets according to existence of different cytokines and TH1 is important in defense against tumors. Therefore, it will be reasonable to test whether ELF-EMF can change cytokines like interferon gamma (IFN-γ), interleukin-4 (IL-4), IL-6, and IL-12 that regulate TH1/TH2/TH17 balance. Forty adult male rats were randomly separated into ELF-EMF-exposed and sham-exposed control groups. The ELF-EMF group was exposed to a flux density of 100 μT, frequency 50 Hz, 2 h/day for 3 months. The controls were placed in identical chamber without ELF-EMF. The results showed there were no significant differences between the mean mass of rats, thymuses, and spleens in ELF-EMF exposed group compared with controls. Serum IL-12 level was decreased from 418 ± 47 pg/ml in controls to 300 ± 23 pg/ml (p < 0.05) in ELF-EMF-exposed group. Phytohemagglutinin activated of in vitro production of IL-6 by the whole spleen culture (1356 ± 92 pg/ml) and total blood culture (418 ± 40 pg/ml) of ELF-EMF-exposed rats were higher (p < 0.001) comparing with controls (905 ± 74 pg/ml), (182 ± 26 pg/ml), respectively. However, the levels of IFN-γ, IL-4, and IL-6 of serum and IFN-γ, IL-4, and IL-12 in spleen culture and total blood culture of two groups were not significantly different. It seems that ELF-EMF may change TH1/TH2/TH17 balance toward down regulation of TH1 and upregulation TH17 type responses.


  • An investigation of gamma background radiation in Hamadan province, Iran

    by Nima Rostampour, Tinoosh Almasi, Masoumeh Rostampour, Mohammad Mohammadi, Karim Ghazikhanlou Sani, Hamid R. Khosravi, S. Mehdi Hosseini Pooya, Bahman Golzar, Naghi Jabari Vesal

    The general population, everywhere in the world is exposed to a small dose of ionising radiation from natural sources. Stochastic effects such as cancer and genetic disorders are caused when living creatures are exposed to low doses. In Iran, it is measured in some cities, especially in high-background areas such as Ramsar, but so far there is no measurement in the Hamadan province. Hamadan is located in the west of Iran. Measurements were performed using a RDS-110 survey meter, CaSO4:Dy thermoluminecense dosimetries (TLDs) and a Harshaw 4000 TLD reader. To estimate the dose rate outdoors, four stations along the main directions (north, south, west and east) and one in the town centre were selected. Mean annual X and gamma equivalent dose in Hamadan province are 1.12±0.22 and 1.66±0.07 mSv, which related to RDS-110 survey meter and TLDs measurements, respectively. The TLDs and RDS-110 results are representative of the external photon radiation doses for the selected monitoring locations and for those locations for the hours during which the measurements were taken, respectively. Maximum and minimum of external photon radiation doses are related to Hamadan and Kaboudar-Ahang towns, respectively. According to the results of the study, it seems that the annual X and gamma equivalent dose in Hamadan province exceeded the global mean external exposure amounts by the UNSCEAR, and further studies are needed to measure internal exposures to determine the total environmental radiation level in Hamadan province.


    • 1 December 2011
      • Vol. 36  (4) , 306-310

    A Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures

    by Karim Ghazikhanlou Sani, Mahmoodreza Jafari, Nima Rostampoor

    The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were taken from other views (predominantly oblique views), making a total number of 128 radiographs. Paired radiographs, taken from the same areas, were compared by two radiologists in terms of image visual sharpness, presence of bony fractures, and soft tissue injuries. The surface dose received by patients in the two systems was also compared. The radiographs taken by mammography film-screen had a statistically better visual sharpness compared to those taken by the standard film-screen system. However, there was no statistically significant difference between the diagnostic accuracy of the two systems. Mammography film-screen was able to detect only one out of 57 lesions, whereas standard film-screen system did not detec any lesion. The surface dose received by patients in mammography film-screen was higher than that in standard film-screen system. The findings of the present study suggest that mammography film-screen may be recommended as a diagnostic tool for the detection of small fractures of tinny parts of body such as fingers, hand or foot. They also suggest that mammography film-screen has no advantage over standard film-screen for radiography of thick body parts such as neck and knee.

    • 1 September 2010
      • Vol. 15  (5) , 292-293
    Open Access

    Observance of radiation protection principles in Iranian dental schools

    by Amir Eskandarlou, Karim Ghazi-Khanlou Sani, Nima Rostampour