Hong-Hsi Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hong-Hsi Lee has a total of 207 co-authors. Here are the top co-authors by number of shared publications:
- Susie Y. Huang
Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States
20 shared publications - Dmitry Anatolievich Novikov
Faculty of Mathematics and Computer Science, Weizmann Institute of Science, Rehovot, Israel
16 shared publications - Els Fieremans
Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology New York University School of Medicine New York New York USA
16 shared publications - Hansol Lee
Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology Massachusetts General Hospital Charlestown Massachusetts USA
11 shared publications Els Fieremans
Center for Advanced Imaging Innovation and Research, New York, NY, USA
10 shared publications- Qiyuan Tian
School of Biomedical Engineering, Tsinghua University, Beijing, China
10 shared publications
Latest Publications
- Open Access
- 9 October 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Reduced NEXI protocol for the quantification of human gray matter microstructure on the Connectome 2.0 scanner
Biophysical diffusion MRI models such as Neurite Exchange Imaging (NEXI) are essential for probing gray matter microstructure, estimating compartment diffusivities (Di, De), neurite fraction (f), and exchange time (tex). However, NEXI multi-shell, multi-diffusion-time requirements lead to prohibitively long acquisitions. Leveraging the Connectome 2.0 ultra-high gradient scanner, we developed a time-efficient protocol using an Explainable AI (XAI) framework. Combining XGBoost, SHAP, and Recursive Feature Elimination trained on synthetic signals, XAI identified an optimal 8-feature subset, halving scan time from 27 to 14 minutes. Validated in vivo in 7 healthy participants, the XAI protocol was benchmarked against the full 15-feature acquisition, a Cramér-Rao Lower Bound (CRLB) theoretical optimum, and 2 expert-designed heuristics (“Mid-Range” and “Corner”). The XAI protocol robustly reproduced parameter estimates and maintained full protocol test–retest reproducibility. Remarkably, the data-driven XAI selection converged to the theoretical CRLB optimum. This validates XAI mathematical optimality while highlighting its primary advantage: achieving gold-standard optimization without requiring complex analytical Jacobians, making it effortlessly adaptable to numerically defined models or complex noise distributions where CRLB becomes intractable. Furthermore, XAI demonstrated superior in vivo robustness compared with heuristics: “Mid-Range” sampling yielded biased tex estimates due to insufficient temporal diversity, while “Corner” sampling yielded unstable Di estimates (fivefold higher coefficient of variation) due to noise sensitivity. Ultimately, this robust 14-minute NEXI protocol accelerates exchange-sensitive microstructural mapping, establishing a generalizable, model-agnostic optimization framework adaptable to future ultra-high gradient systems (e.g., Siemens Cima.X or GE MAGNUS) and existing clinical scanners.
- 9 October 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Open AccessReduced NEXI protocol for the quantification of human gray matter microstructure on the Connectome 2.0 scanner
Biophysical diffusion MRI models such as Neurite Exchange Imaging (NEXI) are essential for probing gray matter microstructure, estimating compartment diffusivities (Di, De), neurite fraction (f), and exchange time (tex). However, NEXI multi-shell, multi-diffusion-time requirements lead to prohibitively long acquisitions. Leveraging the Connectome 2.0 ultra-high gradient scanner, we developed a time-efficient protocol using an Explainable AI (XAI) framework. Combining XGBoost, SHAP, and Recursive Feature Elimination trained on synthetic signals, XAI identified an optimal 8-feature subset, halving scan time from 27 to 14 minutes. Validated in vivo in 7 healthy participants, the XAI protocol was benchmarked against the full 15-feature acquisition, a Cramér-Rao Lower Bound (CRLB) theoretical optimum, and 2 expert-designed heuristics (“Mid-Range” and “Corner”). The XAI protocol robustly reproduced parameter estimates and maintained full protocol test–retest reproducibility. Remarkably, the data-driven XAI selection converged to the theoretical CRLB optimum. This validates XAI mathematical optimality while highlighting its primary advantage: achieving gold-standard optimization without requiring complex analytical Jacobians, making it effortlessly adaptable to numerically defined models or complex noise distributions where CRLB becomes intractable. Furthermore, XAI demonstrated superior in vivo robustness compared with heuristics: “Mid-Range” sampling yielded biased tex estimates due to insufficient temporal diversity, while “Corner” sampling yielded unstable Di estimates (fivefold higher coefficient of variation) due to noise sensitivity. Ultimately, this robust 14-minute NEXI protocol accelerates exchange-sensitive microstructural mapping, establishing a generalizable, model-agnostic optimization framework adaptable to future ultra-high gradient systems (e.g., Siemens Cima.X or GE MAGNUS) and existing clinical scanners.
- Open Access
- 9 September 2026
- Published by Elsevier in NeuroImage
- Vol. 341
Improving the accessibility of deep learning-based denoising for accelerated brain MRI using self-supervised learning and/or transfer learning
- 9 September 2026
- Published by Elsevier in NeuroImage
- Vol. 341
Open AccessImproving the accessibility of deep learning-based denoising for accelerated brain MRI using self-supervised learning and/or transfer learning
- Open Access
- 27 August 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (6) , 2780-2794
Clinical Soma and Neurite Density Imaging ( SANDI ): Translational Microstructure Mapping on Clinical 3T MRI Scanners
Purpose: The Soma and Neurite Density Imaging (SANDI) model enables characterization of gray matter (GM) microstructure by estimating soma and neurite signal fractions, but its clinical applicability is limited by the need for multi‐shell acquisitions (at least five b ‐values up to 6000 s/mm 2 ), requiring high‐gradient MRI systems. We developed a clinically feasible SANDI model that reduces data requirements and model complexity while preserving sensitivity to cellular‐level microstructural features. Methods: Clinical SANDI incorporates biophysical constraints via fixed intra‐neurite diffusivity and a tortuosity relation from effective medium theory to estimate extracellular diffusivity from intracellular volume fractions, reducing the number of free parameters and data requirements. The model was validated using Monte Carlo diffusion simulations in GM‐like microenvironments and evaluated in vivo on the ultra‐high‐gradient 3 T Connectome 2.0 scanner ( G max = 500 mT/m, five‐shell, ∼19 min) and a clinical 3 T system ( G max = 80 mT/m, two‐shell, ∼7 min). Additional experiments across multiple gradient strengths, diffusion times, and sites assessed model robustness. Results: Diffusion simulations showed close agreement (Pearson r = 0.99) between simulated and theoretical extracellular diffusivity across varying intracellular volume fractions. With 500 mT/m gradients, clinical SANDI using two shells demonstrated strong correspondence with five‐shell standard SANDI ( r = 0.97, intraclass correlation coefficient = 0.94). Across reduced gradient strengths, clinical SANDI preserved cortical intra‐soma signal fraction values, whereas standard SANDI exhibited underestimation at gradient strengths below 80 mT/m. Conclusion: Clinical SANDI enables reliable cortical GM microstructure estimation on widely available clinical 3T scanners within feasible scan times, facilitating broader translation of advanced diffusion MRI methods for studying aging, neurodegeneration, and neurological disorders.
- 27 August 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (6) , 2780-2794
Open AccessClinical Soma and Neurite Density Imaging ( SANDI ): Translational Microstructure Mapping on Clinical 3T MRI Scanners
Purpose: The Soma and Neurite Density Imaging (SANDI) model enables characterization of gray matter (GM) microstructure by estimating soma and neurite signal fractions, but its clinical applicability is limited by the need for multi‐shell acquisitions (at least five b ‐values up to 6000 s/mm 2 ), requiring high‐gradient MRI systems. We developed a clinically feasible SANDI model that reduces data requirements and model complexity while preserving sensitivity to cellular‐level microstructural features. Methods: Clinical SANDI incorporates biophysical constraints via fixed intra‐neurite diffusivity and a tortuosity relation from effective medium theory to estimate extracellular diffusivity from intracellular volume fractions, reducing the number of free parameters and data requirements. The model was validated using Monte Carlo diffusion simulations in GM‐like microenvironments and evaluated in vivo on the ultra‐high‐gradient 3 T Connectome 2.0 scanner ( G max = 500 mT/m, five‐shell, ∼19 min) and a clinical 3 T system ( G max = 80 mT/m, two‐shell, ∼7 min). Additional experiments across multiple gradient strengths, diffusion times, and sites assessed model robustness. Results: Diffusion simulations showed close agreement (Pearson r = 0.99) between simulated and theoretical extracellular diffusivity across varying intracellular volume fractions. With 500 mT/m gradients, clinical SANDI using two shells demonstrated strong correspondence with five‐shell standard SANDI ( r = 0.97, intraclass correlation coefficient = 0.94). Across reduced gradient strengths, clinical SANDI preserved cortical intra‐soma signal fraction values, whereas standard SANDI exhibited underestimation at gradient strengths below 80 mT/m. Conclusion: Clinical SANDI enables reliable cortical GM microstructure estimation on widely available clinical 3T scanners within feasible scan times, facilitating broader translation of advanced diffusion MRI methods for studying aging, neurodegeneration, and neurological disorders.
- Open Access
- 27 June 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (5) , 2426-2439
Dependence of the Extra‐Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter
Purpose: The dependence of the long‐time (tortuosity) limit of the extra‐cellular diffusivity on the intra‐cellular volume fraction is of fundamental importance for microstructure modeling. While such dependencies have been explored for the white matter, the tortuosity limit in gray matter is unknown due to complex cell composition and geometry. Here we rationalize and validate numerically the analytical relation between the extra‐cellular diffusivity and intra‐cellular fractions of cell bodies (somas) and neurites. Methods: The tortuosity relation for extra‐cellular diffusivity qualitatively follows from effective medium theory, coarse‐grained by diffusion outside somas (spheres) and neurites (cylinders), respectively. This problem is equivalent to finding the overall conductivity in a medium of grains in a matrix, with methodology dating back to the 19th century. We extend the effective medium methodology to populations of impermeable spheres and randomly oriented cylinders with various volume fractions, yielding closed‐form expressions corroborated by Monte Carlo simulations. Results: We establish the power‐law scaling of the extra‐cellular diffusivity with the volume fractions of the extra‐soma and extra‐neurite spaces. We further evaluate the proposed framework using simulations in realistic tissue geometries, and by applying it to in vivo MRI data. Conclusion: Theory and simulations relate extra‐cellular tortuosity to soma and neurite fractions, thereby offering a diffusion MRI protocol design optimized for in vivo assessment of soma size and soma/neurite fractions within clinical scan times. Such in vivo measurements can be used to study development, aging, and neurodegenerative disorders.
- 27 June 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (5) , 2426-2439
Open AccessDependence of the Extra‐Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter
Purpose: The dependence of the long‐time (tortuosity) limit of the extra‐cellular diffusivity on the intra‐cellular volume fraction is of fundamental importance for microstructure modeling. While such dependencies have been explored for the white matter, the tortuosity limit in gray matter is unknown due to complex cell composition and geometry. Here we rationalize and validate numerically the analytical relation between the extra‐cellular diffusivity and intra‐cellular fractions of cell bodies (somas) and neurites. Methods: The tortuosity relation for extra‐cellular diffusivity qualitatively follows from effective medium theory, coarse‐grained by diffusion outside somas (spheres) and neurites (cylinders), respectively. This problem is equivalent to finding the overall conductivity in a medium of grains in a matrix, with methodology dating back to the 19th century. We extend the effective medium methodology to populations of impermeable spheres and randomly oriented cylinders with various volume fractions, yielding closed‐form expressions corroborated by Monte Carlo simulations. Results: We establish the power‐law scaling of the extra‐cellular diffusivity with the volume fractions of the extra‐soma and extra‐neurite spaces. We further evaluate the proposed framework using simulations in realistic tissue geometries, and by applying it to in vivo MRI data. Conclusion: Theory and simulations relate extra‐cellular tortuosity to soma and neurite fractions, thereby offering a diffusion MRI protocol design optimized for in vivo assessment of soma size and soma/neurite fractions within clinical scan times. Such in vivo measurements can be used to study development, aging, and neurodegenerative disorders.
- Open Access
- 23 March 2026
- Published by Springer Nature in Communications Biology
- Vol. 9 (1)
Visualizing cortical laminar architecture in the living human brain using next-generation ultra-high-gradient diffusion MRI
Characterizing cortical laminar microstructure is essential for understanding the organization of the human brain. Leveraging the next-generation Connectome MRI scanner (maximum gradient strength=500mT/m, slew rate=600 T/m/s), we characterized in vivo cortical laminar cytoarchitecture and myeloarchitecture through cortical depth-dependent analyses of soma and neurite density imaging (SANDI) metrics derived from 1 mm diffusion MRI generated using a super-resolution technique. SANDI revealed distinct laminar profiles: intra-soma signal fraction peaked at ~55% cortical depth, while the intra-neurite signal fraction increased toward deeper cortical layers, consistent with known histological patterns. The visual cortex showed higher intra-soma signal fraction than the motor cortex, particularly in deeper layers. Intra-soma signal fraction correlated positively with cortical curvature in superficial layers and negatively in deeper layers, indicating layer-specific relationships between cortical microstructure and geometry. These findings demonstrate the feasibility of noninvasive mapping of laminar architecture, offering a potential in vivo surrogate for histology and enabling future studies of cortical laminar organization using high-performance gradient MRI.
- 23 March 2026
- Published by Springer Nature in Communications Biology
- Vol. 9 (1)
Open AccessVisualizing cortical laminar architecture in the living human brain using next-generation ultra-high-gradient diffusion MRI
Characterizing cortical laminar microstructure is essential for understanding the organization of the human brain. Leveraging the next-generation Connectome MRI scanner (maximum gradient strength=500mT/m, slew rate=600 T/m/s), we characterized in vivo cortical laminar cytoarchitecture and myeloarchitecture through cortical depth-dependent analyses of soma and neurite density imaging (SANDI) metrics derived from 1 mm diffusion MRI generated using a super-resolution technique. SANDI revealed distinct laminar profiles: intra-soma signal fraction peaked at ~55% cortical depth, while the intra-neurite signal fraction increased toward deeper cortical layers, consistent with known histological patterns. The visual cortex showed higher intra-soma signal fraction than the motor cortex, particularly in deeper layers. Intra-soma signal fraction correlated positively with cortical curvature in superficial layers and negatively in deeper layers, indicating layer-specific relationships between cortical microstructure and geometry. These findings demonstrate the feasibility of noninvasive mapping of laminar architecture, offering a potential in vivo surrogate for histology and enabling future studies of cortical laminar organization using high-performance gradient MRI.
- Open Access
- 15 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3429-3444
Complementary Sensitivity of Fixed‐Time and Fixed‐Oscillation Regimes to Exchange and Structural Disorder in the Human Brain Revealed Using Oscillating‐Gradient Diffusion MRI With Ultra‐Strong Gradients
Purpose: Oscillating‐gradient spin‐echo (OGSE) diffusion MRI probes cell geometry and membrane integrity through the frequency‐dependence of kurtosis, but prior studies have reported inconsistent findings depending on how frequency is varied. We compared frequency‐dependent kurtosis in the human brain under two regimes: varying frequency with fixed total waveform duration (fixed‐) or number of oscillations (fixed‐). Methods: Eleven healthy volunteers were scanned on the 3 T Connectome 2.0 system with OGSE using 500 mT/m gradients. Mean kurtosis (MK) was measured using three fixed‐ waveforms ( ≈ 80 ms) and four fixed‐ waveforms ( = 1). The adiabatic Kärger exchange model was fit to MK in 48 white matter (WM) and 70 gray matter (GM) regions, yielding estimates of water exchange time (), intracellular fraction (), extracellular tortuosity (), and asymptotic kurtosis (). Results: Distinct frequency‐dependence was observed between regimes. In fixed‐, MK decreased with frequency in both WM and GM, reflecting diffusion coarse‐graining from structural disorder. In fixed‐, MK increased with frequency in GM but was relatively flat in WM, indicating greater sensitivity to exchange. Parameter estimates showed biologically meaningful contrasts: WM exhibited longer , higher , and greater , consistent with tightly packed, myelinated axons and anisotropic extracellular space. GM showed shorter and higher , reflecting greater heterogeneity and CSF partial volume. Conclusion: Fixed‐ and fixed‐ OGSE provide complementary sensitivity to microstructural features. Fixed‐ emphasizes structural disorder, while fixed‐ highlights membrane permeability and exchange. The extended frequency regimes enabled by ultra‐strong gradients advance OGSE as a powerful tool for probing human brain tissue microstructure.
- 15 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3429-3444
Open AccessComplementary Sensitivity of Fixed‐Time and Fixed‐Oscillation Regimes to Exchange and Structural Disorder in the Human Brain Revealed Using Oscillating‐Gradient Diffusion MRI With Ultra‐Strong Gradients
Purpose: Oscillating‐gradient spin‐echo (OGSE) diffusion MRI probes cell geometry and membrane integrity through the frequency‐dependence of kurtosis, but prior studies have reported inconsistent findings depending on how frequency is varied. We compared frequency‐dependent kurtosis in the human brain under two regimes: varying frequency with fixed total waveform duration (fixed‐) or number of oscillations (fixed‐). Methods: Eleven healthy volunteers were scanned on the 3 T Connectome 2.0 system with OGSE using 500 mT/m gradients. Mean kurtosis (MK) was measured using three fixed‐ waveforms ( ≈ 80 ms) and four fixed‐ waveforms ( = 1). The adiabatic Kärger exchange model was fit to MK in 48 white matter (WM) and 70 gray matter (GM) regions, yielding estimates of water exchange time (), intracellular fraction (), extracellular tortuosity (), and asymptotic kurtosis (). Results: Distinct frequency‐dependence was observed between regimes. In fixed‐, MK decreased with frequency in both WM and GM, reflecting diffusion coarse‐graining from structural disorder. In fixed‐, MK increased with frequency in GM but was relatively flat in WM, indicating greater sensitivity to exchange. Parameter estimates showed biologically meaningful contrasts: WM exhibited longer , higher , and greater , consistent with tightly packed, myelinated axons and anisotropic extracellular space. GM showed shorter and higher , reflecting greater heterogeneity and CSF partial volume. Conclusion: Fixed‐ and fixed‐ OGSE provide complementary sensitivity to microstructural features. Fixed‐ emphasizes structural disorder, while fixed‐ highlights membrane permeability and exchange. The extended frequency regimes enabled by ultra‐strong gradients advance OGSE as a powerful tool for probing human brain tissue microstructure.
- Open Access
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (6) , 2883-2896
Axon Diameter Mapping From Myelin Water Diffusion MRI
Probing diffusion in myelin water using diffusion-weighted T1-/T2-selective MRI acquisitions enables noninvasive measurement of myelinated axon diameter. Its application for in vivo measurements requires numerical verification through diffusion simulations. Here, we propose the theory of myelin water diffusion as measured with a diffusion MRI pulse sequence with wide gradient pulses using the Gaussian phase approximation. We establish its applicability to axonal diameter mapping via Monte Carlo simulations in either infinitely thin cylindrical surfaces or concentric cylindrical shells of finite thickness, mimicking the micro-geometry of myelin sheaths. The estimated diameters are shown to be weighted more toward outer than inner calibers. Simulation results evaluate the theory of myelin water diffusion and axon diameter estimation using spherical mean diffusion signals, demonstrating its applicability at signal-to-noise ratio above 20 on the Connectome 2.0 MRI scanner equipped with maximum gradient strength of 500 mT/m and slew rate of 600 T/m/s. Measuring restricted diffusion of myelin water in-between myelin sheaths using diffusion MRI allows one to measure myelinated axon diameters in vivo. The protocol can potentially be adapted for clinically available high-gradient performance scanners.
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (6) , 2883-2896
Open AccessAxon Diameter Mapping From Myelin Water Diffusion MRI
Probing diffusion in myelin water using diffusion-weighted T1-/T2-selective MRI acquisitions enables noninvasive measurement of myelinated axon diameter. Its application for in vivo measurements requires numerical verification through diffusion simulations. Here, we propose the theory of myelin water diffusion as measured with a diffusion MRI pulse sequence with wide gradient pulses using the Gaussian phase approximation. We establish its applicability to axonal diameter mapping via Monte Carlo simulations in either infinitely thin cylindrical surfaces or concentric cylindrical shells of finite thickness, mimicking the micro-geometry of myelin sheaths. The estimated diameters are shown to be weighted more toward outer than inner calibers. Simulation results evaluate the theory of myelin water diffusion and axon diameter estimation using spherical mean diffusion signals, demonstrating its applicability at signal-to-noise ratio above 20 on the Connectome 2.0 MRI scanner equipped with maximum gradient strength of 500 mT/m and slew rate of 600 T/m/s. Measuring restricted diffusion of myelin water in-between myelin sheaths using diffusion MRI allows one to measure myelinated axon diameters in vivo. The protocol can potentially be adapted for clinically available high-gradient performance scanners.
- Open Access
- 12 December 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (4) , 2277-2290
What If Each Voxel Were Measured With a Different Diffusion Protocol?
Purpose: Expansion of diffusion MRI (dMRI) both into the realm of strong gradients and into accessible imaging with portable low‐field devices brings about the challenge of gradient nonlinearities. Spatial variations of the diffusion gradients make diffusion weightings and directions non‐uniform across the field of view, and deform perfect shells in the ‐space designed for isotropic directional coverage. Such imperfections hinder parameter estimation: Anisotropic shells hamper the deconvolution of the fiber orientation distribution function (fODF), while brute‐force retraining of a nonlinear regressor for each unique set of directions and diffusion weightings is computationally inefficient. Methods: Here, we propose a protocol‐independent parameter estimation (PIPE) method that enables fast parameter estimation for the most general case where each voxel is measured with a different protocol in ‐space. PIPE applies to any spherical convolution‐based dMRI model, irrespective of its complexity, which makes it suitable both for white and gray matter in the brain or spinal cord, and for other tissues where fiber bundles have the same properties (fiber response) within a voxel, but are distributed with an arbitrary fODF. We also derive a parsimonious representation that isolates isotropic and anisotropic effects of gradient nonlinearities on multidimensional diffusion encodings. Results: Applied to in vivo human MRI with linear tensor encoding on a high‐performance gradient system, PIPE evaluates fiber response and fODF parameters for the whole brain in the presence of significant gradient nonlinearities in under 3 min. Conclusions: PIPE enables fast parameter estimation in the presence of arbitrary gradient nonlinearities, eliminating the need to arrange dMRI in shells or to retrain the estimator for different protocols in each voxel. PIPE applies to any model based on a convolution of a voxel‐wise fiber response and fODF, and data from varying ‐values, diffusion/echo times, and other scan parameters.
- 12 December 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (4) , 2277-2290
Open AccessWhat If Each Voxel Were Measured With a Different Diffusion Protocol?
Purpose: Expansion of diffusion MRI (dMRI) both into the realm of strong gradients and into accessible imaging with portable low‐field devices brings about the challenge of gradient nonlinearities. Spatial variations of the diffusion gradients make diffusion weightings and directions non‐uniform across the field of view, and deform perfect shells in the ‐space designed for isotropic directional coverage. Such imperfections hinder parameter estimation: Anisotropic shells hamper the deconvolution of the fiber orientation distribution function (fODF), while brute‐force retraining of a nonlinear regressor for each unique set of directions and diffusion weightings is computationally inefficient. Methods: Here, we propose a protocol‐independent parameter estimation (PIPE) method that enables fast parameter estimation for the most general case where each voxel is measured with a different protocol in ‐space. PIPE applies to any spherical convolution‐based dMRI model, irrespective of its complexity, which makes it suitable both for white and gray matter in the brain or spinal cord, and for other tissues where fiber bundles have the same properties (fiber response) within a voxel, but are distributed with an arbitrary fODF. We also derive a parsimonious representation that isolates isotropic and anisotropic effects of gradient nonlinearities on multidimensional diffusion encodings. Results: Applied to in vivo human MRI with linear tensor encoding on a high‐performance gradient system, PIPE evaluates fiber response and fODF parameters for the whole brain in the presence of significant gradient nonlinearities in under 3 min. Conclusions: PIPE enables fast parameter estimation in the presence of arbitrary gradient nonlinearities, eliminating the need to arrange dMRI in shells or to retrain the estimator for different protocols in each voxel. PIPE applies to any model based on a convolution of a voxel‐wise fiber response and fODF, and data from varying ‐values, diffusion/echo times, and other scan parameters.
- Open Access
- 6 November 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-16
Scattering approach to diffusion quantifies axonal damage in brain injury
Early diagnosis and noninvasive monitoring of neurological disorders require sensitivity to elusive cellular-level alterations that occur much earlier than volumetric changes observable with the millimeter-resolution of medical imaging modalities. Morphological changes in axons, such as axonal varicosities or beadings, are observed in neurological disorders, as well as in development and aging. Here, we reveal the sensitivity of time-dependent diffusion MRI (dMRI) to the structurally disordered axonal morphology at the micrometer scale. Scattering theory uncovers the two parameters that determine the diffusive dynamics of water along axons: the average reciprocal cross-section and the variance of long-range cross-sectional fluctuations. This theoretical development allows us to predict dMRI metrics sensitive to axonal alterations over tens of thousands of axons in seconds rather than months of simulations in a male rat model of traumatic brain injury, and is corroborated with ex vivo dMRI. Our approach bridges the gap between micrometers and millimeters in resolution, offering quantitative and objective biomarkers applicable to a broad spectrum of neurological disorders.
- 6 November 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-16
Open AccessScattering approach to diffusion quantifies axonal damage in brain injury
Early diagnosis and noninvasive monitoring of neurological disorders require sensitivity to elusive cellular-level alterations that occur much earlier than volumetric changes observable with the millimeter-resolution of medical imaging modalities. Morphological changes in axons, such as axonal varicosities or beadings, are observed in neurological disorders, as well as in development and aging. Here, we reveal the sensitivity of time-dependent diffusion MRI (dMRI) to the structurally disordered axonal morphology at the micrometer scale. Scattering theory uncovers the two parameters that determine the diffusive dynamics of water along axons: the average reciprocal cross-section and the variance of long-range cross-sectional fluctuations. This theoretical development allows us to predict dMRI metrics sensitive to axonal alterations over tens of thousands of axons in seconds rather than months of simulations in a male rat model of traumatic brain injury, and is corroborated with ex vivo dMRI. Our approach bridges the gap between micrometers and millimeters in resolution, offering quantitative and objective biomarkers applicable to a broad spectrum of neurological disorders.
- Open Access
- 5 November 2025
- Published by Wiley in Aging Cell
- Vol. 25 (1) , e70274
Age‐Related Alterations in Hippocampal Microstructure Quantified Using High‐Gradient Diffusion MRI ( dMRI ) in an Unfolded Hippocampal Space
The hippocampus, a brain region critical for memory, undergoes significant age‐related changes at both the macroscopic and microstructural levels. This study investigates these changes using high‐gradient diffusion MRI (dMRI) data analyzed in an unfolded hippocampal space. We applied the Soma and Neurite Density Imaging (SANDI) model to quantify microstructural alterations in 72 cognitively healthy participants aged 19–85 years, scanned on a 3 T Connectome MRI scanner with a maximum gradient strength of 300 mT/m. By combining SANDI with a super‐resolution algorithm and the HippUnfold toolbox, we achieved high spatial fidelity in our analysis. We observed significant age‐related reductions in soma fraction and soma radius, particularly in the subiculum and dentate gyrus, alongside increases in extracellular diffusivity and extracellular fraction, indicating a decline in cellular density and structural integrity. These microstructural changes occur alongside macroscopic alterations such as reduced hippocampal volume and cortical thickness, decreased gyrification, and increased curvature in specific subfields. The spatial correlations between microstructural and macroscopic metrics across the unfolded hippocampal space are weak, both in their mean values and in how they change with age. Our findings suggest that SANDI metrics provide sensitive and complementary information to traditional structural measures, offering new insights into the microstructural underpinnings of hippocampal aging. This study highlights the potential of advanced dMRI techniques to detect subtle age‐related changes in hippocampal microstructure, which may contribute to our understanding of aging and its impact on memory and cognition.
- 5 November 2025
- Published by Wiley in Aging Cell
- Vol. 25 (1) , e70274
Open AccessAge‐Related Alterations in Hippocampal Microstructure Quantified Using High‐Gradient Diffusion MRI ( dMRI ) in an Unfolded Hippocampal Space
The hippocampus, a brain region critical for memory, undergoes significant age‐related changes at both the macroscopic and microstructural levels. This study investigates these changes using high‐gradient diffusion MRI (dMRI) data analyzed in an unfolded hippocampal space. We applied the Soma and Neurite Density Imaging (SANDI) model to quantify microstructural alterations in 72 cognitively healthy participants aged 19–85 years, scanned on a 3 T Connectome MRI scanner with a maximum gradient strength of 300 mT/m. By combining SANDI with a super‐resolution algorithm and the HippUnfold toolbox, we achieved high spatial fidelity in our analysis. We observed significant age‐related reductions in soma fraction and soma radius, particularly in the subiculum and dentate gyrus, alongside increases in extracellular diffusivity and extracellular fraction, indicating a decline in cellular density and structural integrity. These microstructural changes occur alongside macroscopic alterations such as reduced hippocampal volume and cortical thickness, decreased gyrification, and increased curvature in specific subfields. The spatial correlations between microstructural and macroscopic metrics across the unfolded hippocampal space are weak, both in their mean values and in how they change with age. Our findings suggest that SANDI metrics provide sensitive and complementary information to traditional structural measures, offering new insights into the microstructural underpinnings of hippocampal aging. This study highlights the potential of advanced dMRI techniques to detect subtle age‐related changes in hippocampal microstructure, which may contribute to our understanding of aging and its impact on memory and cognition.