Pei-Jan Paul Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pei-Jan Paul Lin has a total of 199 co-authors. Here are the top co-authors by number of shared publications:
Richard A. Mintzer
10 shared publicationsHarvey L. Neiman
Northwestern University Medical School (United States)
5 shared publicationsVassilios Raptopoulos
Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Ave, Boston, MA 02215
5 shared publicationsAtsushi Fukuda
Department of Radiological Sciences, School of Health Sciences Fukushima Medical University Fukushima Fukushima Japan
4 shared publicationsStephen Balter
Departments of Medicine and Radiology Columbia University Medical Center New York New York USA
4 shared publicationsTakeshi Kubo
Department of Diagnostic Imaging, Graduate School of Medicine, Kyoto University, 606‐8507 Kyoto, Japan
4 shared publications
Latest Publications
- Open Access
- 11 November 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
Accuracy of reference air kerma in estimating incident air kerma at skin in interventional neuroradiology: Effect of X‐ray field size and alternative PERP corrections
Background: Kerma‐area product (KAP) meters monitor reference air kerma () and KAP (. While is calculated using and collimator positions, is directly measured via a small central ionization chamber. Although is a common surrogate for incident air kerma at the skin (), its clinical application to interventional neuroradiological procedures carries higher uncertainty than regular interventional radiology, with source‐to‐skin distance being the greatest factor due to the smaller head size. Additionally, may not perfectly represent actual due to variations in beam quality, filtration, and X‐ray field size. Purpose: This study investigated (1) the accuracy of and , and (2) the feasibility of employing them as surrogates for during cerebral angiography and interventional neuroradiological procedures. Methods: A solid‐state dosimeter (AGMS‐DM+) was placed at the patient entrance reference point (PERP) on a polymethyl methacrylate phantom to measure . Accuracies of and were evaluated against in two investigations. First, effects of tube voltage and spectral shaping filters (1.2 mmAl, 0.03 mmTa, and 0.2 mmCu) were evaluated with/without equalization filters inserted symmetrically by 2.5 cm from both sides at a fixed X‐ray field size of 10 × 10 cm 2 . Second, the effect of varying the X‐ray field size was investigated for each filter. Additionally, a fluoroscopic system and a head phantom were modeled using computer‐aided design software. Three fields of view (FOVs) were evaluated to simulate different clinical stages: 30 × 30 cm 2 (for whole angiography), 15 × 15 cm 2 , and 3.8 × 3.8 cm 2 (for targeted interventional neuroradiology). Target centers were aligned with the brain center and precallosal segment of the anterior cerebral artery. Six typical clinical projections were used per FOV to determine source‐to‐skin distance and X‐ray field size at the PERP, allowing calculation of the skin‐level errors for both and . The effects of the corrections were also investigated using the X‐ray field size measured by / and an alternative PERP (aPERP) positioned 11 cm from the isocenter toward the X‐ray focus. Results: Relative errors for both methods as functions of tube voltage across the three filters were within ± 4.0%. With equalization filters, errors ranged from −49.0%–−33.9%, exceeding the acceptable accuracy tolerance (± 35%), whereas errors (−15.8%–−10.8%) remained within the tolerance. The relative errors of and as a function of the X‐ray field size ranged from −9.7%–12.7% and −58.3%–26.1%, respectively. Although most skin‐level errors for both and remained within the ± 35% tolerance in clinical simulation, those for at the 3.8 × 3.8 cm 2 FOV exceeded it. However, with the X‐ray field size and aPERP corrections, the errors for were reduced to within ± 2.7%. Conclusions: and should be strategically selected based on the specific clinical application, such as standard cerebral angiography versus targeted interventional neuroradiology. Particularly, provides superior accuracy when equalization filters are used or when appropriate corrections for X‐ray field size and aPERP are applied in small‐field dosimetry.
- 11 November 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
Open AccessAccuracy of reference air kerma in estimating incident air kerma at skin in interventional neuroradiology: Effect of X‐ray field size and alternative PERP corrections
Background: Kerma‐area product (KAP) meters monitor reference air kerma () and KAP (. While is calculated using and collimator positions, is directly measured via a small central ionization chamber. Although is a common surrogate for incident air kerma at the skin (), its clinical application to interventional neuroradiological procedures carries higher uncertainty than regular interventional radiology, with source‐to‐skin distance being the greatest factor due to the smaller head size. Additionally, may not perfectly represent actual due to variations in beam quality, filtration, and X‐ray field size. Purpose: This study investigated (1) the accuracy of and , and (2) the feasibility of employing them as surrogates for during cerebral angiography and interventional neuroradiological procedures. Methods: A solid‐state dosimeter (AGMS‐DM+) was placed at the patient entrance reference point (PERP) on a polymethyl methacrylate phantom to measure . Accuracies of and were evaluated against in two investigations. First, effects of tube voltage and spectral shaping filters (1.2 mmAl, 0.03 mmTa, and 0.2 mmCu) were evaluated with/without equalization filters inserted symmetrically by 2.5 cm from both sides at a fixed X‐ray field size of 10 × 10 cm 2 . Second, the effect of varying the X‐ray field size was investigated for each filter. Additionally, a fluoroscopic system and a head phantom were modeled using computer‐aided design software. Three fields of view (FOVs) were evaluated to simulate different clinical stages: 30 × 30 cm 2 (for whole angiography), 15 × 15 cm 2 , and 3.8 × 3.8 cm 2 (for targeted interventional neuroradiology). Target centers were aligned with the brain center and precallosal segment of the anterior cerebral artery. Six typical clinical projections were used per FOV to determine source‐to‐skin distance and X‐ray field size at the PERP, allowing calculation of the skin‐level errors for both and . The effects of the corrections were also investigated using the X‐ray field size measured by / and an alternative PERP (aPERP) positioned 11 cm from the isocenter toward the X‐ray focus. Results: Relative errors for both methods as functions of tube voltage across the three filters were within ± 4.0%. With equalization filters, errors ranged from −49.0%–−33.9%, exceeding the acceptable accuracy tolerance (± 35%), whereas errors (−15.8%–−10.8%) remained within the tolerance. The relative errors of and as a function of the X‐ray field size ranged from −9.7%–12.7% and −58.3%–26.1%, respectively. Although most skin‐level errors for both and remained within the ± 35% tolerance in clinical simulation, those for at the 3.8 × 3.8 cm 2 FOV exceeded it. However, with the X‐ray field size and aPERP corrections, the errors for were reduced to within ± 2.7%. Conclusions: and should be strategically selected based on the specific clinical application, such as standard cerebral angiography versus targeted interventional neuroradiology. Particularly, provides superior accuracy when equalization filters are used or when appropriate corrections for X‐ray field size and aPERP are applied in small‐field dosimetry.
- Open Access
- 9 October 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (10) , e70281
Investigating the use of ionization chamber and solid‐state detectors to evaluate kerma‐area product meter accuracy under TG‐125 geometry across variable field of views
Background: A kerma‐area product (KAP) meter has been installed in a fluoroscopic system, and its accuracy has been evaluated in task group (TG)‐190 geometry using an external detector. However, it is unclear that external detectors could evaluate the KAP meter accuracy under the TG‐125 geometry. Purpose: This study investigated whether the reference air kerma rate () values of the KAP meter increase with increasing field of view (FOV) and whether an external ionization chamber and solid‐state detector (SSD) could be used to evaluate KAP meter accuracy in TG‐125 geometry. Methods: An ionization chamber and three different SSDs (Radcal AGMS‐DM+, Raysafe X2 R/F sensor, and RTI Dose Probe) were placed at the patient entrance reference point in a C‐arm fluoroscopic system, and measurements were taken at FOV settings of 18, 25, 34, and 42 cm using both the TG‐190 and TG‐125 geometries. The , incident air kerma rate (, and entrance surface air kerma rate ( values were recorded simultaneously and compared. The measurement data were used to calculate the backscatter factor. Results: The increased linearly with the relative X‐ray output, and their slopes significantly increased with the FOV. The values of the ionization chamber increased with the FOV; however, the values of the ionization chamber, and values of the SSDs were not dependent on the FOV and were nearly identical to each other. Although the backscatter factor for the KAP meter and ionization chamber increased with the FOV, the backscatter for the SSDs were close to unity in all FOVs and no significant difference was observed. Conclusions: The results indicated that the values of KAP meter were increased with the FOV. Furthermore, the SSDs could be utilized to evaluate the KAP meter accuracy in TG‐125 geometry.
- 9 October 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (10) , e70281
Open AccessInvestigating the use of ionization chamber and solid‐state detectors to evaluate kerma‐area product meter accuracy under TG‐125 geometry across variable field of views
Background: A kerma‐area product (KAP) meter has been installed in a fluoroscopic system, and its accuracy has been evaluated in task group (TG)‐190 geometry using an external detector. However, it is unclear that external detectors could evaluate the KAP meter accuracy under the TG‐125 geometry. Purpose: This study investigated whether the reference air kerma rate () values of the KAP meter increase with increasing field of view (FOV) and whether an external ionization chamber and solid‐state detector (SSD) could be used to evaluate KAP meter accuracy in TG‐125 geometry. Methods: An ionization chamber and three different SSDs (Radcal AGMS‐DM+, Raysafe X2 R/F sensor, and RTI Dose Probe) were placed at the patient entrance reference point in a C‐arm fluoroscopic system, and measurements were taken at FOV settings of 18, 25, 34, and 42 cm using both the TG‐190 and TG‐125 geometries. The , incident air kerma rate (, and entrance surface air kerma rate ( values were recorded simultaneously and compared. The measurement data were used to calculate the backscatter factor. Results: The increased linearly with the relative X‐ray output, and their slopes significantly increased with the FOV. The values of the ionization chamber increased with the FOV; however, the values of the ionization chamber, and values of the SSDs were not dependent on the FOV and were nearly identical to each other. Although the backscatter factor for the KAP meter and ionization chamber increased with the FOV, the backscatter for the SSDs were close to unity in all FOVs and no significant difference was observed. Conclusions: The results indicated that the values of KAP meter were increased with the FOV. Furthermore, the SSDs could be utilized to evaluate the KAP meter accuracy in TG‐125 geometry.
- Open Access
- 24 August 2022
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 23 (10) , e13763
Reducing stray radiation with a novel detachable lead arm support in percutaneous coronary intervention
Background: Placing radioprotective devices near patients reduces stray radiation during percutaneous coronary intervention (PCI), a promising technique for treating coronary artery disease. Therefore, lead arm support may effectively reduce occupational radiation dose to cardiologists.Purpose: We aimed to estimate the reduction of stray radiation using a novel detachable lead arm support (DLAS) in PCI.Materials and methods: A dedicated cardiovascular angiography system was equipped with the conventional 0.5‐mm lead curtain suspended from the table side rail. The DLAS was developed using an L‐shaped acrylic board and detachable water‐resistant covers encasing the 0.5‐, 0.75‐, or 1.0‐mm lead. The DLAS was placed adjacent to a female anthropomorphic phantom lying on the examination tabletop at the patient entrance reference point. An ionization chamber survey meter was placed 100 cm away from the isocenter to emulate the cardiologist's position. Dose reduction using the L‐shaped acrylic board, DLAS, lead curtain, and their combination each was measured at five heights (80–160 cm in 20‐cm increments) when acquiring cardiac images of the patient phantom with 10 gantry angulations, typical for PCI.Results: Median dose reductions of stray radiation using the L‐shaped acrylic board were 9.0%, 8.8%, 12.4%, 12.3%, and 6.4% at 80‐, 100‐, 120‐, 140‐, and 160‐cm heights, respectively. Dose reduction using DLAS with a 0.5‐mm lead was almost identical to that using DLAS with 0.75‐ and 1.0‐mm leads; mean dose reductions using these three DLASs increased to 16.2%, 45.1%, 66.0%, 64.2%, and 43.0%, respectively. Similarly, dose reductions using the conventional lead curtain were 95.9%, 95.5%, 83.7%, 26.0%, and 19.6%, respectively. The combination of DLAS with 0.5‐mm lead and lead curtain could increase dose reductions to 96.0%, 95.8%, 93.8%, 71.1%, and 47.1%, respectively.Conclusions: DLAS reduces stray radiation at 120‐, 140‐, and 160‐cm heights, where the conventional lead curtain provides insufficient protection.
- 24 August 2022
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 23 (10) , e13763
Open AccessReducing stray radiation with a novel detachable lead arm support in percutaneous coronary intervention
Background: Placing radioprotective devices near patients reduces stray radiation during percutaneous coronary intervention (PCI), a promising technique for treating coronary artery disease. Therefore, lead arm support may effectively reduce occupational radiation dose to cardiologists.Purpose: We aimed to estimate the reduction of stray radiation using a novel detachable lead arm support (DLAS) in PCI.Materials and methods: A dedicated cardiovascular angiography system was equipped with the conventional 0.5‐mm lead curtain suspended from the table side rail. The DLAS was developed using an L‐shaped acrylic board and detachable water‐resistant covers encasing the 0.5‐, 0.75‐, or 1.0‐mm lead. The DLAS was placed adjacent to a female anthropomorphic phantom lying on the examination tabletop at the patient entrance reference point. An ionization chamber survey meter was placed 100 cm away from the isocenter to emulate the cardiologist's position. Dose reduction using the L‐shaped acrylic board, DLAS, lead curtain, and their combination each was measured at five heights (80–160 cm in 20‐cm increments) when acquiring cardiac images of the patient phantom with 10 gantry angulations, typical for PCI.Results: Median dose reductions of stray radiation using the L‐shaped acrylic board were 9.0%, 8.8%, 12.4%, 12.3%, and 6.4% at 80‐, 100‐, 120‐, 140‐, and 160‐cm heights, respectively. Dose reduction using DLAS with a 0.5‐mm lead was almost identical to that using DLAS with 0.75‐ and 1.0‐mm leads; mean dose reductions using these three DLASs increased to 16.2%, 45.1%, 66.0%, 64.2%, and 43.0%, respectively. Similarly, dose reductions using the conventional lead curtain were 95.9%, 95.5%, 83.7%, 26.0%, and 19.6%, respectively. The combination of DLAS with 0.5‐mm lead and lead curtain could increase dose reductions to 96.0%, 95.8%, 93.8%, 71.1%, and 47.1%, respectively.Conclusions: DLAS reduces stray radiation at 120‐, 140‐, and 160‐cm heights, where the conventional lead curtain provides insufficient protection.
- 20 January 2022
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 15 (1) , 6-24
Review and investigation of automatic brightness/dose rate control logic of fluoroscopic imaging systems in cardiovascular interventional angiography
In this article, we review automatic brightness control (ABC) for fluoroscopy imaging systems. Starting from the simple manual control, the discussion is extended to the kV-primary ABC system, and then to the most recent contrast-to-noise ratio optimized (CNR Optimized) automatic dose rate control system (ADRC). The nature of this review article is trifold. First, it describes the ABC/ADRC and associated circuits governing the operation of the fluoroscopy imaging chain. Second, we show the characteristics of a control logic from a radiation physics point of view. Third, we introduce the most recent activities in the evaluation of CNR-optimized fluoroscopy systems and the phantom design that would be compatible with the design concept of the ADRC. Because of these three subject items in the discussion process, this article is also educational in nature written for medical physicists and radiological technologists who might be less familiar with the design concept of fluoroscopy operation, specifically on the ABC and ADRC. We insert a few related matters associated with fluoroscopy automatic control circuits where they seem applicable and appropriate to enhance the understanding of fluoroscopy operation logic.
- 20 January 2022
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 15 (1) , 6-24
Review and investigation of automatic brightness/dose rate control logic of fluoroscopic imaging systems in cardiovascular interventional angiography
In this article, we review automatic brightness control (ABC) for fluoroscopy imaging systems. Starting from the simple manual control, the discussion is extended to the kV-primary ABC system, and then to the most recent contrast-to-noise ratio optimized (CNR Optimized) automatic dose rate control system (ADRC). The nature of this review article is trifold. First, it describes the ABC/ADRC and associated circuits governing the operation of the fluoroscopy imaging chain. Second, we show the characteristics of a control logic from a radiation physics point of view. Third, we introduce the most recent activities in the evaluation of CNR-optimized fluoroscopy systems and the phantom design that would be compatible with the design concept of the ADRC. Because of these three subject items in the discussion process, this article is also educational in nature written for medical physicists and radiological technologists who might be less familiar with the design concept of fluoroscopy operation, specifically on the ABC and ADRC. We insert a few related matters associated with fluoroscopy automatic control circuits where they seem applicable and appropriate to enhance the understanding of fluoroscopy operation logic.
- 15 January 2022
- Published by Wiley in Medical Physics
- Vol. 49 (4) , E1-E49
AAPM Task Group Report 272: Comprehensive acceptance testing and evaluation of fluoroscopy imaging systems
Modern fluoroscopes used for image guidance have become quite complex. Adding to this complexity are the many regulatory and accreditation requirements that must be fulfilled during acceptance testing of a new unit. Further, some of these acceptance tests have pass/fail criteria, whereas others do not, making acceptance testing a subjective and time‐consuming task. The AAPM Task Group 272 Report spells out the details of tests that are required and gives visibility to some of the tests that while not yet required are recommended as good practice. The organization of the report begins with the most complicated fluoroscopes used in interventional radiology or cardiology and continues with general fluoroscopy and mobile C‐arms. Finally, the appendices of the report provide useful information, an example report form and topics that needed their own section due to the level of detail.
- 15 January 2022
- Published by Wiley in Medical Physics
- Vol. 49 (4) , E1-E49
AAPM Task Group Report 272: Comprehensive acceptance testing and evaluation of fluoroscopy imaging systems
Modern fluoroscopes used for image guidance have become quite complex. Adding to this complexity are the many regulatory and accreditation requirements that must be fulfilled during acceptance testing of a new unit. Further, some of these acceptance tests have pass/fail criteria, whereas others do not, making acceptance testing a subjective and time‐consuming task. The AAPM Task Group 272 Report spells out the details of tests that are required and gives visibility to some of the tests that while not yet required are recommended as good practice. The organization of the report begins with the most complicated fluoroscopes used in interventional radiology or cardiology and continues with general fluoroscopy and mobile C‐arms. Finally, the appendices of the report provide useful information, an example report form and topics that needed their own section due to the level of detail.
- Open Access
- 10 August 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (9) , 339-344
Accuracy of HVL measurements utilizing solid state detectors for radiography and fluoroscopy X‐ray systems
The half‐value layer (HVL) is one of the regulatory required radiation safety parameters that needs to be measured annually. With the advent of solid state detectors and their associated electrometer assembly, the HVL measurement can be conducted with relative ease. In fact, various radiological technique parameters such as tube potential (kV), exposure time in millisecond (msec), air kerma (mGy), and air kerma rate (mGy/sec) can be obtained along with the HVL with just one exposure. The measured (or, calculated) HVL is based on radiation detection systems calibrated for conventional x‐ray systems equipped with tungsten anode and added aluminum filters (molybdenum anode and filter in the case of mammography systems). However, a new generation of radiography and fluoroscopy (R/F) systems, inclusive of interventional angiography equipment, is equipped with varying thicknesses and materials of spectral shaping filters (SSF) to minimize the radiation exposure to the patients while image quality is maintained and optimized. The accuracy of HVL obtained with new generation of R/F systems has not been investigated in depth due to the addition of spectral filters yielding a harder beam quality with a higher HVL than the regulatory required value of 2.9 mm Al HVL at 80 kV. It would be of great interest to determine the accuracy of HVL as measured (or, calculated) by the solid state detector systems (SSDS), especially when accurate radiation dose delivered to the patient is required. In this investigation, the subject is limited to the accuracy of HVL measurement for conventional R/F systems.
- 10 August 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (9) , 339-344
Open AccessAccuracy of HVL measurements utilizing solid state detectors for radiography and fluoroscopy X‐ray systems
The half‐value layer (HVL) is one of the regulatory required radiation safety parameters that needs to be measured annually. With the advent of solid state detectors and their associated electrometer assembly, the HVL measurement can be conducted with relative ease. In fact, various radiological technique parameters such as tube potential (kV), exposure time in millisecond (msec), air kerma (mGy), and air kerma rate (mGy/sec) can be obtained along with the HVL with just one exposure. The measured (or, calculated) HVL is based on radiation detection systems calibrated for conventional x‐ray systems equipped with tungsten anode and added aluminum filters (molybdenum anode and filter in the case of mammography systems). However, a new generation of radiography and fluoroscopy (R/F) systems, inclusive of interventional angiography equipment, is equipped with varying thicknesses and materials of spectral shaping filters (SSF) to minimize the radiation exposure to the patients while image quality is maintained and optimized. The accuracy of HVL obtained with new generation of R/F systems has not been investigated in depth due to the addition of spectral filters yielding a harder beam quality with a higher HVL than the regulatory required value of 2.9 mm Al HVL at 80 kV. It would be of great interest to determine the accuracy of HVL as measured (or, calculated) by the solid state detector systems (SSDS), especially when accurate radiation dose delivered to the patient is required. In this investigation, the subject is limited to the accuracy of HVL measurement for conventional R/F systems.
- Open Access
- 18 June 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (7) , 216-220
Characterization and verification of lead thickness of commercially available lead foil tape for the measurements of lead equivalency of radio‐protective shields
Purpose Radiation protective apparatus is normally specified in "millimeter" of lead equivalence. Typically, it is less than 0.5 mmPb with the exception of lead eyeglasses, which may be 0.75 mmPb equivalent. Upon discovery of commercially available lead foil tape, manufactured by 3M™ "Lead Foil Tape 421" (LFT) which is designed for industrial utility applications. We set out to determine if this LFT can, indeed, be employed as the reference lead in the evaluation of lead equivalency of various protective apparatus. Method The LFT is cut to appropriate size (50 mm × 50 mm) and stacked for varying the total lead thickness for the transmission measurements. The transmission curves are obtained following the geometry spelled out in ASTM Designation F3094‐14 standards. The radiation beam qualities corresponding to modern cardiovascular angiography equipment in the range of 60~120 kVp, in increments of 10 kVp, and in combination with the spectral shaping filters of 0, 0.1, 0.2, 0.3, 0.6 and 0.9 mmCu were employed for characterization of the lead foil tape. The transmission data of lead pieces with known thicknesses (1/64", 1/32" and 3/64") are superimposed on the lead foil tape transmission curves to validate that the 3M™ LFT is indeed usable as 0.1 mm lead. Results The transmission ratio (data points) of lead pieces with known thicknesses at various radiation beam qualities mentioned above, fall right onto the transmission curves of 3M™ LFT with better than 2% accuracy. Therefore, it is indeed behaving like 0.1 mm thick lead sheet, based on the superimposed transmission curves. The 3M™ "Lead Foil Tape 421" is employed as the reference lead for evaluation of radiation protective apparatus at this institution. Verification of lead protective apparatus with unknown lead equivalence can now be determined with a high accuracy and certainty.
- 18 June 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (7) , 216-220
Open AccessCharacterization and verification of lead thickness of commercially available lead foil tape for the measurements of lead equivalency of radio‐protective shields
Purpose Radiation protective apparatus is normally specified in "millimeter" of lead equivalence. Typically, it is less than 0.5 mmPb with the exception of lead eyeglasses, which may be 0.75 mmPb equivalent. Upon discovery of commercially available lead foil tape, manufactured by 3M™ "Lead Foil Tape 421" (LFT) which is designed for industrial utility applications. We set out to determine if this LFT can, indeed, be employed as the reference lead in the evaluation of lead equivalency of various protective apparatus. Method The LFT is cut to appropriate size (50 mm × 50 mm) and stacked for varying the total lead thickness for the transmission measurements. The transmission curves are obtained following the geometry spelled out in ASTM Designation F3094‐14 standards. The radiation beam qualities corresponding to modern cardiovascular angiography equipment in the range of 60~120 kVp, in increments of 10 kVp, and in combination with the spectral shaping filters of 0, 0.1, 0.2, 0.3, 0.6 and 0.9 mmCu were employed for characterization of the lead foil tape. The transmission data of lead pieces with known thicknesses (1/64", 1/32" and 3/64") are superimposed on the lead foil tape transmission curves to validate that the 3M™ LFT is indeed usable as 0.1 mm lead. Results The transmission ratio (data points) of lead pieces with known thicknesses at various radiation beam qualities mentioned above, fall right onto the transmission curves of 3M™ LFT with better than 2% accuracy. Therefore, it is indeed behaving like 0.1 mm thick lead sheet, based on the superimposed transmission curves. The 3M™ "Lead Foil Tape 421" is employed as the reference lead for evaluation of radiation protective apparatus at this institution. Verification of lead protective apparatus with unknown lead equivalence can now be determined with a high accuracy and certainty.
- 1 December 2015
- Published by Wiley in Medical Physics
- Vol. 42 (12) , 6815-6829
Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190
Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, “dose‐area‐product” (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG‐190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term “DAP‐meter” has been revised to air kerma‐area product (KAP) meter. The charge of TG 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the “Accuracy and Calibration of Integrated Radiation Output Indicators” which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical “meter.” To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.
- 1 December 2015
- Published by Wiley in Medical Physics
- Vol. 42 (12) , 6815-6829
Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190
Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, “dose‐area‐product” (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG‐190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term “DAP‐meter” has been revised to air kerma‐area product (KAP) meter. The charge of TG 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the “Accuracy and Calibration of Integrated Radiation Output Indicators” which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical “meter.” To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.
- 28 July 2015
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 67 (1) , 82-88
Operating characteristics of tube-current-modulation techniques when scanning simple-shaped phantoms
Our objective was to investigate the operating characteristics of tube current modulation (TCM) in computed tomography (CT) when scanning two types of simple-shaped phantoms. A tissueequivalent elliptical phantom and a homogeneous cylindrical step phantom comprising 16-, 24-, and 32-cm-diameter polymethyl methacrylate (PMMA) phantoms were scanned by using an automatic exposure control system with longitudinal (z-) and angular-longitudinal (xyz-) TCM and with a fixed tube current. The axial dose distribution throughout the elliptical phantom and the longitudinal dose distribution at the center of the cylindrical step phantom were measured by using a solid-state detector. Image noise was quantitatively measured at eight regions in the elliptical phantom and at 90 central regions in contiguous images over the full z extent of the cylindrical step phantom. The mean absorbed doses and the standard deviations in the elliptical phantom with z- and xyz-TCM were 12.3’ 3.7 and 11.3’ 3.5 mGy, respectively. When TCM was activated, some differences were observed in the absorbed doses of the left and the right measurement points. The average image noises in Hounsfield units (HU) and the standard deviations were 15.2’ 2.4 and 15.9’ 2.4 HU when using z- and xyz-TCM, respectively. With respect to the cylindrical step phantom under z-TCM, there were sudden decreases followed by increases in image noise at the interfaces with the 24- and 16-cm-diameter phantoms. The image noise of the 24-cm-diameter phantom was, relatively speaking, higher than those of the 16- and 32-cm-diameter phantoms. The simple-shaped phantoms used in this study can be employed to investigate the operating characteristics of automatic exposure control systems when specialized phantoms designed for that purpose are not available.
- 28 July 2015
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 67 (1) , 82-88
Operating characteristics of tube-current-modulation techniques when scanning simple-shaped phantoms
Our objective was to investigate the operating characteristics of tube current modulation (TCM) in computed tomography (CT) when scanning two types of simple-shaped phantoms. A tissueequivalent elliptical phantom and a homogeneous cylindrical step phantom comprising 16-, 24-, and 32-cm-diameter polymethyl methacrylate (PMMA) phantoms were scanned by using an automatic exposure control system with longitudinal (z-) and angular-longitudinal (xyz-) TCM and with a fixed tube current. The axial dose distribution throughout the elliptical phantom and the longitudinal dose distribution at the center of the cylindrical step phantom were measured by using a solid-state detector. Image noise was quantitatively measured at eight regions in the elliptical phantom and at 90 central regions in contiguous images over the full z extent of the cylindrical step phantom. The mean absorbed doses and the standard deviations in the elliptical phantom with z- and xyz-TCM were 12.3’ 3.7 and 11.3’ 3.5 mGy, respectively. When TCM was activated, some differences were observed in the absorbed doses of the left and the right measurement points. The average image noises in Hounsfield units (HU) and the standard deviations were 15.2’ 2.4 and 15.9’ 2.4 HU when using z- and xyz-TCM, respectively. With respect to the cylindrical step phantom under z-TCM, there were sudden decreases followed by increases in image noise at the interfaces with the 24- and 16-cm-diameter phantoms. The image noise of the 24-cm-diameter phantom was, relatively speaking, higher than those of the 16- and 32-cm-diameter phantoms. The simple-shaped phantoms used in this study can be employed to investigate the operating characteristics of automatic exposure control systems when specialized phantoms designed for that purpose are not available.
- 22 November 2014
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 8 (1) , 141-145
Accuracy of gantry rotation time of less than 300 ms for modern MDCT systems
The accuracy of gantry rotation times of less than 300 ms has been assessed for two "state-of-the art" MDCT systems. The rotation time was measured at selected nominal rotation times (275 and 280 ms) with a solid-state detector; Unfors Xi probe. The detector was positioned on the inner bottom of the gantry bore. Because a pair of two successive radiation peaks is necessary for determination of the rotation time, the radiation detection was performed with the helical scan mode of operation. Upon completion of the data acquisition, we determined the peak times with the Unfors Xi View software program to obtain the rotation time. The means and standard deviations of the measured rotation times were 275.3 ± 0.5 and 285.1 ± 0.4 ms, respectively. The inaccuracy of the rotation time was approximately 5 ms at most, which was comparable to that previously reported for slower rotation times.
- 22 November 2014
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 8 (1) , 141-145
Accuracy of gantry rotation time of less than 300 ms for modern MDCT systems
The accuracy of gantry rotation times of less than 300 ms has been assessed for two "state-of-the art" MDCT systems. The rotation time was measured at selected nominal rotation times (275 and 280 ms) with a solid-state detector; Unfors Xi probe. The detector was positioned on the inner bottom of the gantry bore. Because a pair of two successive radiation peaks is necessary for determination of the rotation time, the radiation detection was performed with the helical scan mode of operation. Upon completion of the data acquisition, we determined the peak times with the Unfors Xi View software program to obtain the rotation time. The means and standard deviations of the measured rotation times were 275.3 ± 0.5 and 285.1 ± 0.4 ms, respectively. The inaccuracy of the rotation time was approximately 5 ms at most, which was comparable to that previously reported for slower rotation times.