RMRalph Michael

Ralph Michael

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ralph Michael has a total of 81 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Feasibility and repeatability of ocular biometry measured with IOLMaster 700 in a large population‐based study

    by Ralph Michael, Kerstin Wirkner, Christoph Engel, Markus Loeffler, Toralf Kirsten, Franziska G. Rauscher

    Purpose: To evaluate the feasibility and repeatability of IOLMaster 700 biometry measurements in an adult population. Furthermore, to assess the value of the Quality Indicators (QIs) provided by the device. Method: As part of the large population‐based Leipzig Research Centre for Civilization Diseases (LIFE) Adult‐Study, randomly selected participants from Leipzig, Germany were evaluated with the ZEISS IOLMaster 700. Age range was 26–85 years, with 53% of participants above 70 years of age. Axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT) and keratometry (K) were assessed in 1767 right eyes. Measurements were repeated twice and in a subset of 1331 eyes, three times. Measurement feasibility was evaluated for three levels; successful, with warnings and failed, using the inbuilt QIs. Repeatability was assessed as within‐subject standard deviation (SD) and repeatability limits were calculated. Results: First measurement success rate for phakic eyes was over 99% for AL, CCT, ACD, over 98% for LT and over 97% for K. K had 16% eyes with warnings and the recommendation to repeat the measurement. Excluding the measurements with warnings resulted in a reduction of mean SD for AL from 48 to 4 μm and for mean K from 0.08 to 0.04 D. Repeatability for phakic eyes was 8 μm for AL, CCT, ACD and LT and 2.3 μm for CCT; 0.07 D and 0.12 D for mean K and delta K, respectively, for phakic cases without warnings (two measurements). Conclusions: In our population‐based sample, the IOLMaster 700 collected data for AL, CCT, ACD, LT and K from the vast majority of eyes. Considering the built‐in QIs improved the measurement variability substantially. Repeatability measurements indicate that clinically meaningful changes can be detected reliably with this instrument.


  • Commercial affinity

    by Michael Ralph

    The resurgence of interest in the role chattel slavery has played in US capital growth has been marked by an abiding emphasis on the Cotton Kingdom. Highlighting the 19th-century sector that arguably generated more wealth than any other—with enduring implications for governance and the management of difference—scholars have trained their emphasis on the Mississippi River Valley. One implication of this approach is that scholars have focused on the role between coercion and productivity, generally arguing for a direct correlation. That is, from Edward Baptist to Walter Johnson 1 and many others, the argument is that capitalist societies rely on violence and that increasing violence enhances productivity. The consequence is an emphasis on capitalism as a violent system and capital growth as a brutal process. The fact that social historians interested in capital and slavery in the emergence of capitalist societies have generally eschewed defining any of these key terms has only exacerbated the problem.

  • Open Access

    Soemmerring’s Rings Developed around IOLs, in Human Donor Eyes, Can Present Internal Transparent Areas

    by Justin Christopher D’antin, Francesc Tresserra, Rafael I. Barraquer, Ralph Michael

    Soemmerring’s rings consist of a ring of lens epithelial derived cells that grow along the periphery of an aphakic lens capsule, or around an intraocular lens. These rings when visualized frontally, appear opaque, however, in some cases the cells that compose these rings are organized in the same fashion as those in normal transparent adult lenses. Thus, our purpose was to test whether any part of the adult Soemmerring’s ring could be transparent and how this related to morphological factors. To study this, 16 Soemmerring’s rings were extracted from donor eye globes. After imaging, they were thickly sectioned sagittally in order to analyze the degrees of transparency of different areas. All samples were also histologically analyzed using alpha smooth muscle actin, Vimentin, wheat germ agglutinin and DAPI. Our results showed that many samples had some transparent areas, mostly towards the center of their cross-section. Of the factors that we analyzed, only lens fiber organization at the bow region and an increased area of mature lens fiber cells had a significant relation to the degree of transparency at the center. Thus, we can conclude that as Soemmerring’s rings mature, they can develop organized and transparent areas of lens cells.


  • Open Access

    Ocular biometry in children and adolescents from 4 to 17 years: a cross‐sectional study in central Germany

    by Franziska G Rauscher, Mike Francke, Andreas Hiemisch, Wieland Kiess, Ralph Michael

    Purpose: To evaluate ocular biometry in a large paediatric population as a function of age and sex in children of European descent. Methods: Children were examined as part of the LIFE Child Study (Leipzig Research Centre for Civilization Disease), a population‐based study in Leipzig, Germany. Altogether, 1907 children, aged from 4 to 17 years, were examined with the Lenstar LS 900. Data from the right eye was analysed for axial length, central corneal thickness, flat and steep corneal radii, aqueous depth, lens thickness and vitreous depth. Wavefront‐based autorefraction was employed for analysis. Results: Axial length increased in girls from 21.6 mm (4 years) up to 23.4 mm (17 years); this increase (0.174 mm per year) was statistically significant up to age 14 (23.3 mm). Axial length increased in boys from 22.2 mm (4 years) up to 23.9 mm (17 years); this increase (0.178 mm per year) was statistically significant up to age 10 (23.3 mm). No change was observed for central corneal thickness (average: girls 550 µm; boys 554 µm). Corneal curvature in girls was somewhat flatter at age 4 (7.70 mm) compared to age 10 (7.78 mm), whereas it was constant in boys (7.89 mm). Aqueous depth at age 4 was 2.73 mm for girls and 2.86 mm for boys, with the same rate of increase per year (girls: 0.046 mm; boys: 0.047 mm) from age 4 to 10. At age 17, aqueous depth was 3.06 mm in girls and 3.20 mm in boys. Lens thickness was reduced from age 4 (3.75 mm) to age 10 (3.47 mm) in girls and from age 4 (3.73 mm) to age 10 (3.44 mm) in boys, with the same rate of decrease per year of 0.046 and 0.047 mm, respectively. At age 17, lens thickness was 3.52 mm in girls and 3.50 mm in boys. Vitreous depth at age 4 was 14.51 mm for girls and 15.08 mm for boys; with 0.156 mm (girls) or 0.140 mm (boys) increase per year until age 14 (girls: 16.08 mm; boys: 16.48 mm). At age 17, vitreous depth was 16.29 mm in girls and 16.62 mm in boys. Conclusions: Eye growth (axial length) in girls showed a lag of about four years compared to boys. Aqueous depth increase matches the lens thickness decrease from ages 4 to 10 years in girls and boys. Lens thickness minimum is reached at 11 years in girls and at 12 years in boys. All dimensions of the optical ocular components are closely correlated with axial length. These data may serve as normative values for the assessment of eye growth in central European children and will provide a basis for monitoring refractive error development.


  • Causes of corneal transplant failure: a multicentric study

    by Alba Gómez‐Benlloch, Andrea Montesel, Luis Pareja‐Aricò, David Mingo‐Botín, Ralph Michael, Rafael I. Barraquer, Jorge Alió

    Purpose: To identify the causes of failure of the different surgical corneal graft techniques: penetrating keratoplasty (PK), deep anterior lamellar keratoplasty (DALK), Descemet stripping automated endothelial keratoplasty (DSAEK) and Descemet membrane endothelial keratoplasty (DMEK).Methods: This multicentric retrospective study enrolled a consecutive cohort of patients who had undergone any type of keratoplasty between 2001 and 2016. The clinical data were obtained from the patient's medical records, following ethical guidelines, permissions and data protection. The main outcome measured in the study was the cause of graft failure, defined as any irreversible loss of graft transparency capable of compromising vision. The main causes of graft failure were classified as follows: (A) primary graft failure (PGF), (B) immunological rejection, (C) non‐rejection (which includes endothelial decompensation without rejection, IOP elevation/glaucoma, diseases of the ocular surface, recurrence of the primary disease, wound dehiscence/hypotonia and trauma, among others) and (D) specific causes of lamellar keratoplasty failure. A descriptive study of the obtained data was carried out. The distribution of the causes of failure was evaluated according to the type of corneal transplant.Results: Our research included a cohort of 571 keratoplasty failures, of which 509 met the inclusion criteria. The analysis of the causes of the PK failure showed that immunological allograft rejection represented the main cause, with 28.2% of the failures, followed by surface diseases (17.8%) and endothelial decompensation without rejection (17.3%). For the PK re‐grafts group, the main cause of failure was immunological allograft rejection (34.0%), followed by diseases of the ocular surface (18.5%). For the DALK group, the failures mainly occurred due to surface diseases such as limbal stem cell insufficiency, infectious keratitis, keratolysis or persistent epithelial defect (37.8%). However, the main reason for failure in the DSAEK group was endothelial decompensation without rejection (31.9%) while primary graft failure was the main cause of failure in the DMEK group (64.1%).Conclusion: The main reason for failure in PK was immunological allograft rejection, both in primary and secondary transplants. The leading causes for failure were diseases of the ocular surface in the DALK population, endothelial decompensation without rejection in DSAEK and primary graft failure in DMEK.


  • Open Access

    Deformations and Ruptures in Human Lenses With Cortical Cataract Subjected to Ex Vivo Simulated Accommodation

    by Ralph Michael, Justin Christopher D'ANtin, Laura Pinilla Cortés, Harvey John Burd, Brian Sheil, Rafael I. Barraquer

    Purpose: Human cortical opacities are most commonly accompanied by changes in lens fiber structure in the equatorial region at the lens nucleus–cortex interface. Cortex and nucleus have different elastic properties, which change with age. We therefore subjected ex vivo lenses to simulated accommodation and studied the internal deformations to better understand the mechanism of cortical cataract formation. Methods: Nine human donor lenses (33–88 years old) were tested using a bespoke radial stretching device for anterior eye segments. Seven of the lenses exhibited cortical cataracts. The other two lenses, without cataract, were used as controls. Frontal and cross-sectional images of the lens obtained during stretching facilitated measurements on equatorial lens diameter and central lens thickness in the stretched and unstretched states. Results: Stretching caused the lens equatorial diameter to increase in all cases. Conversely, the lens central thickness showed no systematic variation during stretching. For four of the lenses with cortical cataract, ruptures were observed during stretching at the nucleus–cortex boundary adjacent to the cortical cataracts. Ruptures were not observed in the control lenses or in the three other lenses with cortical cataract. Conclusions: Internal ruptures can occur in aged ex vivo lenses subjected to simulated disaccommodation. These ruptures occur at the nucleus–cortex interface; at this location, a significant stiffness discontinuity is expected to develop with age. It is hypothesized that ruptures occur in in vivo lenses during accommodation—or attempted accommodation.


  • Open Access

    Bacterial nanocellulose as a corneal bandage material: a comparison with amniotic membrane

    by Irene Anton-Sales, Justin Christopher D'ANtin, Jorge Fernández-Engroba, Victor Charoenrook, Anna Laromaine, Anna Roig, Ralph Michael

    Bacterial nanocellulose exhibits valuable properties to act as a corneal bandage material in terms of conformability, suturability, durability and ease of manipulation in ophthalmological environments.


  • Osteo-odonto-, Tibial bone and Boston keratoprosthesis in clinically comparable cases of chemical injury and autoimmune disease

    by Maria Fideliz de la Paz, Borja Salvador-Culla, Victor Charoenrook, José Temprano, Juan Álvarez de Toledo, Günther Grabner, Ralph Michael, Rafael I. Barraquer


  • Cortical Cataract and Refractive Error

    by Ralph Michael, Luis Pareja-Aricò, Franziska G. Rauscher, Rafael I. Barraquer

    Purpose: To evaluate the relationship between the presence of cortical cataract and accommodation effort, using refractive error as a proxy. Methods: Patients between 50 and 90 years, scheduled for cataract surgery, were selected with the help of a photographic database. Nuclear and cortical cataract were graded and patients grouped having no cataract, pure cortical, mixed or pure nuclear cataract. Refraction data at the time of the photograph was converted to estimated spherical equivalent refractive error each patient would have had at the age of 45 years. Results: From the initial 239 eyes from 239 patients, cases with myopia below –6.5 dpt and hyperopia above 6.5 dpt were excluded, resulting in 199 cases for final analysis. Eyes with no cataract showed the lowest median refractive error (–3.65 dpt), followed by the pure nuclear group (–2.69 dpt). The median refractive error for pure cortical (–0.23 dpt) and mixed cataracts (–0.87 dpt) were close to emmetropia. Cortical cataracts were found in 37% of myopes, 82% of emmetropes, and 85% of hyperopes. Conclusion: Emmetropes and hyperopes tend to develop more cortical cataract than myopes. These cortical cataracts might be caused by shear stress inside the crystalline lens due to accommodation efforts at the time of onset of presbyopia.


  • Open Access

    Prevention of posterior capsule opacification through intracapsular hydrogen peroxide or distilled water treatment in human donor tissue

    by Justin Christopher D’antin, Rafael I. Barraquer, Francisco Tresserra, Ralph Michael

    In order to determine whether posterior capsule opacification after cataract surgery, could be delayed or inhibited through the application of hydrogen peroxide (H2O2) or distilled water (H2Od),we extracted lens capsules from 25 human donor eye globes. Samples were treated for 5 min with either 30 mM H2O2 or H2Od or used as controls, and cultured for one month, during which dark field and tilt illumination photos were taken. These were used to observe and quantify, time until cellular growth and confluence on the posterior capsule. After culture, histological sections were stained for H&E, α-SMA, Ki-67 and vimentin and evaluated. We prevented cellular growth in 50% of H2Od and 58% H2O2 of treated samples. The overall prevention of cell growth compared to cultured controls was significant for both treatments while there was no significant difference between them. In the cases where cellular growth was not prevented, both treatments significantly delay cellular growth. Until day 28 none of the treated samples of either type that had shown growth reached total confluence. All cultured controls reached total confluence before treated samples (median = day 11.5). Also, histologically, there was a clear morphological difference between cultured controls and treated samples.