KQKamala Qalandar

Kamala Qalandar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kamala Qalandar has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • A. Ma

    University of California at Santa Barbara 1 Department of Mechanical Engineering Santa Barbara, California 93106, USA

    1 shared publication
  • B. S. Strachan

    Michigan State University 2 Department of Mechanical Engineering East Lansing, Michigan 48823, USA

    1 shared publication
  • Brian Gibson

    Department of Mechanical Engineering, University of California, Santa Barbara, USA

    1 shared publication
  • Brian Gibson

    Department of Mechanical Engineering, University of California Santa Barbara, Santa Barbara, CA, USA

    1 shared publication
  • Cristian Cassella

    Department of Electrical and Computer Engineering, Carnegie Melon University, Pittsburgh, USA

    1 shared publication
  • Gianluca Piazza

    Department of Electrical and Computer Engineering, Carnegie Melon University, Pittsburgh, USA

    1 shared publication

Latest Publications

  • Analysis of the impact of release area on the quality factor of contour-mode resonators by laser Doppler vibrometry

    by Brian Gibson, Kamala Qalandar, Kimberly Turner, Cristian Cassella, Gianluca Piazza

    Energy dissipation through the anchors of an aluminum nitride (AlN) MEMS contour-mode resonator (CMR) plays an important role in setting the device quality factor at frequencies under 500MHz [1]. The acoustic energy leaving the resonator is effected, not only by the anchor, but also the portion of the surrounding device layer that has been released from the substrate during fabrication. Typical device simulations used for design do not take into account the motion of this additional area. Using laser Doppler vibrometery and COMSOL simulations we show a variation in device Q by 28% as a result of the motion of this released region.


  • Frequency division using a micromechanical resonance cascade

    by K. R. Qalandar, B. S. Strachan, B. Gibson, M. Sharma, A. Ma, S. W. Shaw, K. L. Turner

    A coupled micromechanical resonator array demonstrates a mechanical realization of multi-stage frequency division. The mechanical structure consists of a set of N sequentially perpendicular microbeams that are connected by relatively weak elastic elements such that the system vibration modes are localized to individual microbeams and have natural frequencies with ratios close to 1:2:⋯:2N. Conservative (passive) nonlinear inter-modal coupling provides the required energy transfer between modes and is achieved by finite deformation kinematics. When the highest frequency beam is excited, this arrangement promotes a cascade of subharmonic resonances that achieve frequency division of 2j at microbeam j for j = 1, …, N. Results are shown for a capacitively driven three-stage divider in which an input signal of 824 kHz is passively divided through three modal stages, producing signals at 412 kHz, 206 kHz, and 103 kHz. The system modes are characterized and used to delineate the range of AC input voltages and frequencies over which the cascade occurs. This narrow band frequency divider has simple design rules that are scalable to higher frequencies and can be extended to a larger number of modal stages.