Takurou Daimaru
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takurou Daimaru has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Hiroki Nagai
Institute of Fluid Science, Tohoku University 1 , 2-1-1 Katahira, Aoba, Sendai, Miyagi 980-8577
6 shared publications Hiroki Nagai
3 shared publicationsHiroyuki Sugita
2 shared publicationsAkiko Kawachi
Tokai University
1 shared publicationAtsushi Okamoto
1 shared publication- Atsushi Okamoto
Japan Aerospace Exploration Agency , 2-1-1 Sengen, Tsukuba, Ibaraki 305-8505, Japan
1 shared publication
Latest Publications
- 1 June 2017
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 109, 791-806
Comparison between numerical simulation and on-orbit experiment of oscillating heat pipes
- 1 June 2017
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 109, 791-806
Comparison between numerical simulation and on-orbit experiment of oscillating heat pipes
- 1 February 2017
- Published by Elsevier in Applied Thermal Engineering
- Vol. 113, 1219-1227
Study on thermal cycle in oscillating heat pipes by numerical analysis
- 1 February 2017
- Published by Elsevier in Applied Thermal Engineering
- Vol. 113, 1219-1227
Study on thermal cycle in oscillating heat pipes by numerical analysis
- 1 January 2016
- Published by Japan Society for Aeronautical and Space Sciences in TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, AEROSPACE TECHNOLOGY JAPAN
- Vol. 14 (ists30) , Pi_7-Pi_15
Experimental Study of Effects of Secondary Wick Configuration on Thermal Performance of Loop Heat Pipe
In this study, we experimentally investigated the effects of the secondary wick configuration on the thermal performance of a loop heat pipe (LHP). The results indicated that two important factors affect the heat transfer characteristics: (1) contact area between the secondary wick and the reservoir, and (2) cross-sectional area of evaporator core. We then propose a desirable secondary wick configuration by considering these two factors.
- 1 January 2016
- Published by Japan Society for Aeronautical and Space Sciences in TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, AEROSPACE TECHNOLOGY JAPAN
- Vol. 14 (ists30) , Pi_7-Pi_15
Experimental Study of Effects of Secondary Wick Configuration on Thermal Performance of Loop Heat Pipe
In this study, we experimentally investigated the effects of the secondary wick configuration on the thermal performance of a loop heat pipe (LHP). The results indicated that two important factors affect the heat transfer characteristics: (1) contact area between the secondary wick and the reservoir, and (2) cross-sectional area of evaporator core. We then propose a desirable secondary wick configuration by considering these two factors.
- 1 January 2016
- Published by Japan Society for Aeronautical and Space Sciences in TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, AEROSPACE TECHNOLOGY JAPAN
- Vol. 14 (ists30) , Pi_17-Pi_26
Development of a Cooling System for GAPS using Oscillating Heat Pipe
A cooling system using oscillating heat pipe (OHP) has been developed for a balloon-borne astrophysics project GAPS (General Anti-Particle Spectrometer). Taking advantages of OHP, such as high conductivity, low-power, and suitability for spread heat source, OHP is planned to be used to cool the GAPS core detectors. OHP is a novel technique and it has never been utilized in practical use neither for a spacecraft nor for a balloon-craft, regardless of its many advantages. In these several years, we have investigated OHP's suitability for GAPS step by step. At first, we have succeeded in developing a scaleddown OHP model with a three-dimensional routing, which can operate in a wide temperature range around between 230 K and 300 K. We also succeeded in the first OHP flight demonstration with a prototype GAPS balloon experiment. Subsequently, we developed actual-sized OHP models with various routings. Numerical simulation models have been developed in parallel to further optimize the OHP design by understanding the OHP performance both macroscopically and microscopically. The design of the OHP check valve has been improved as well. This paper discusses the latest status of the GAPS-OHP development.
- 1 January 2016
- Published by Japan Society for Aeronautical and Space Sciences in TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, AEROSPACE TECHNOLOGY JAPAN
- Vol. 14 (ists30) , Pi_17-Pi_26
Development of a Cooling System for GAPS using Oscillating Heat Pipe
A cooling system using oscillating heat pipe (OHP) has been developed for a balloon-borne astrophysics project GAPS (General Anti-Particle Spectrometer). Taking advantages of OHP, such as high conductivity, low-power, and suitability for spread heat source, OHP is planned to be used to cool the GAPS core detectors. OHP is a novel technique and it has never been utilized in practical use neither for a spacecraft nor for a balloon-craft, regardless of its many advantages. In these several years, we have investigated OHP's suitability for GAPS step by step. At first, we have succeeded in developing a scaleddown OHP model with a three-dimensional routing, which can operate in a wide temperature range around between 230 K and 300 K. We also succeeded in the first OHP flight demonstration with a prototype GAPS balloon experiment. Subsequently, we developed actual-sized OHP models with various routings. Numerical simulation models have been developed in parallel to further optimize the OHP design by understanding the OHP performance both macroscopically and microscopically. The design of the OHP check valve has been improved as well. This paper discusses the latest status of the GAPS-OHP development.
- 1 July 2015
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 29 (3) , 563-571
Operational Characteristics of the Oscillating Heat Pipe with Noncondensable Gas
In this study, the effects of noncondensable gas on the behavior of oscillating heat pipes were investigated. The oscillating heat pipe was made of capillary copper tube, and its turn number was 16. The working fluid used was ethanol, and argon gas was used as noncondensable gas. Experiments were conducted using four different noncondensable gas volume ratios. The temperature and inner pressure of the oscillating heat pipe were measured over a heat input range from 40 to 180 W. The results of this study suggest that the operating characteristics of the oscillating heat pipe were affected by noncondensable gas. In particular, the thermal resistance of the oscillating heat pipe increased with lower heat input as the amount of noncondensable gas increased. In addition, the thermal performance rapidly deteriorated with a large amount of noncondensable gas after local dryout. With higher heat input, the thermal resistance increased even with small noncondensable gas amounts.
- 1 July 2015
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 29 (3) , 563-571
Operational Characteristics of the Oscillating Heat Pipe with Noncondensable Gas
In this study, the effects of noncondensable gas on the behavior of oscillating heat pipes were investigated. The oscillating heat pipe was made of capillary copper tube, and its turn number was 16. The working fluid used was ethanol, and argon gas was used as noncondensable gas. Experiments were conducted using four different noncondensable gas volume ratios. The temperature and inner pressure of the oscillating heat pipe were measured over a heat input range from 40 to 180 W. The results of this study suggest that the operating characteristics of the oscillating heat pipe were affected by noncondensable gas. In particular, the thermal resistance of the oscillating heat pipe increased with lower heat input as the amount of noncondensable gas increased. In addition, the thermal performance rapidly deteriorated with a large amount of noncondensable gas after local dryout. With higher heat input, the thermal resistance increased even with small noncondensable gas amounts.
- Open Access
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Thermal Engineering Conference
- Vol. 2014, _F224-1_
F224 Mathematical Modeling of Oscillating Heat Pipes with Check Valves
A mathematical model of Oscillating Heat Pipes (OHPs) with check valves has been constructed. The mathematical model was a one-dimensional slug flow model. Movement of liquid slugs was governed by pressure differences among vapor plugs and by pressure drops in the tubes. Check valves were reproduced by change of liquid slug's momentum. As a result, check valves caused the circulation flow in OHP.
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Thermal Engineering Conference
- Vol. 2014, _F224-1_
Open AccessF224 Mathematical Modeling of Oscillating Heat Pipes with Check Valves
A mathematical model of Oscillating Heat Pipes (OHPs) with check valves has been constructed. The mathematical model was a one-dimensional slug flow model. Movement of liquid slugs was governed by pressure differences among vapor plugs and by pressure drops in the tubes. Check valves were reproduced by change of liquid slug's momentum. As a result, check valves caused the circulation flow in OHP.
- 1 January 2014
- Published by Japan Society for Aeronautical and Space Sciences in Aerospace Technology Japan, the Japan Society for Aeronautical and Space Sciences
- Vol. 13, 17-24
Non-Condensable Gas Effect in the Oscillating Heat Pipe
In this study, the effect of Non-Condensable Gas (NCG) in Oscillating Heat Pipe (OHP) was evaluated by using Closed Loop OHP (CLOHP) made of copper capillary tube. The working fluid was ethanol and the NCG was argon. Temperature and pressure were measured over the heat input range from 40 W to 180 W. The temperature amplitude, the thermal resistance, the pressure amplitude and frequency were calculated. From the results, the NCG affects the thermal performance of OHP.
- 1 January 2014
- Published by Japan Society for Aeronautical and Space Sciences in Aerospace Technology Japan, the Japan Society for Aeronautical and Space Sciences
- Vol. 13, 17-24
Non-Condensable Gas Effect in the Oscillating Heat Pipe
In this study, the effect of Non-Condensable Gas (NCG) in Oscillating Heat Pipe (OHP) was evaluated by using Closed Loop OHP (CLOHP) made of copper capillary tube. The working fluid was ethanol and the NCG was argon. Temperature and pressure were measured over the heat input range from 40 W to 180 W. The temperature amplitude, the thermal resistance, the pressure amplitude and frequency were calculated. From the results, the NCG affects the thermal performance of OHP.