Mustafa Umit Arabul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mustafa Umit Arabul has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Frans N. van de Vosse
Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
3 shared publications Marcel C. M. Rutten
Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, 5612 AJ and Netherlands
3 shared publicationsRichard G. P. Lopata
Eindhoven University of Technology, Cardiovascular Biomechanics Group, Department of Biomedical Engineering, The Netherlands
2 shared publications- Richard G. P. Lopata
Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
2 shared publications H. Maarten Heres
Eindhoven University of Technology, Cardiovascular Biomechanics Group, Department of Biomedical Engineering, The Netherlands
1 shared publication- H. Maarten Heres
Cardiovascular Biomechanics Group, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
1 shared publication
Latest Publications
- Open Access
- 14 September 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (09) , 096005-17
Modeling toolchain for realistic simulation of photoacoustic data acquisition
Photoacoustic (PA) imaging is a relatively new biomedical imaging modality that employs the wide variety of optical properties found in tissue to generate contrast with ultrasound (US) resolution. Increasingly sophisticated PA setups and signal processing methods are being developed to enhance the capabilities of PA imaging. Phantom experiments are often performed to validate new methods, to characterize PA setups, and to generate training datasets for machine learning. However, the scarcity of high-quality phantoms and the absence of a ground truth in in vitro experiments impedes research. Numerical modeling approaches can provide an in silico research environment, in which all relevant physical parameters are known and controllable. Therefore, an accurate and validated PA imaging toolchain that can generate realistic PA images may accelerate the general development of PA imaging. However, generating realistic PA image data with simulations remains a great challenge. In this research, we propose a thoroughly validated, quantitative, and flexible PA imaging modeling toolchain and demonstrate its capability to simulate the acquisition of PA signals of a physical PA system in both phantoms and complex tissues.
- 14 September 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (09) , 096005-17
Open AccessModeling toolchain for realistic simulation of photoacoustic data acquisition
Photoacoustic (PA) imaging is a relatively new biomedical imaging modality that employs the wide variety of optical properties found in tissue to generate contrast with ultrasound (US) resolution. Increasingly sophisticated PA setups and signal processing methods are being developed to enhance the capabilities of PA imaging. Phantom experiments are often performed to validate new methods, to characterize PA setups, and to generate training datasets for machine learning. However, the scarcity of high-quality phantoms and the absence of a ground truth in in vitro experiments impedes research. Numerical modeling approaches can provide an in silico research environment, in which all relevant physical parameters are known and controllable. Therefore, an accurate and validated PA imaging toolchain that can generate realistic PA images may accelerate the general development of PA imaging. However, generating realistic PA image data with simulations remains a great challenge. In this research, we propose a thoroughly validated, quantitative, and flexible PA imaging modeling toolchain and demonstrate its capability to simulate the acquisition of PA signals of a physical PA system in both phantoms and complex tissues.
- 12 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (3) , 440-447
Investigation on the Effect of Spatial Compounding on Photoacoustic Images of Carotid Plaques in the In Vivo Available Rotational Range
Photoacoustic imaging (PA) is a promising imaging modality due to its high optical specificity. However, the low signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of in vivo PA images are major challenges that prevent PA imaging from finding its place in clinics. This study investigates the merit of spatial compounding of PA images in arterial phantoms and the achievable improvements of SNR when in vivo conditions are mimicked. The analysis of the compounding technique was performed on a polyvinyl alcohol vessel phantom with black threads embedded in its wall. The in vivo conditions were mimicked by limiting the rotation range in ± 30°, adding turbid surrounding medium, and filling the lumen with porcine blood. Finally, the performance of the technique was evaluated in ex vivo human carotid plaque samples. Results showed that spatial compounding elevates the SNR by 5 to 10 dB and CNR by 1 to 5, depending on the location of the absorbers. This study elucidates prospective in vivo PA characterization of carotid plaques by proposing a method to enhance PA image quality.
- 12 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (3) , 440-447
Investigation on the Effect of Spatial Compounding on Photoacoustic Images of Carotid Plaques in the In Vivo Available Rotational Range
Photoacoustic imaging (PA) is a promising imaging modality due to its high optical specificity. However, the low signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of in vivo PA images are major challenges that prevent PA imaging from finding its place in clinics. This study investigates the merit of spatial compounding of PA images in arterial phantoms and the achievable improvements of SNR when in vivo conditions are mimicked. The analysis of the compounding technique was performed on a polyvinyl alcohol vessel phantom with black threads embedded in its wall. The in vivo conditions were mimicked by limiting the rotation range in ± 30°, adding turbid surrounding medium, and filling the lumen with porcine blood. Finally, the performance of the technique was evaluated in ex vivo human carotid plaque samples. Results showed that spatial compounding elevates the SNR by 5 to 10 dB and CNR by 1 to 5, depending on the location of the absorbers. This study elucidates prospective in vivo PA characterization of carotid plaques by proposing a method to enhance PA image quality.
- 24 January 2017
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (4) , 041013
Visualization of vasculature using a hand-held photoacoustic probe: phantom and in vivo validation
Assessment of microvasculature and tissue perfusion can provide diagnostic information on local or systemic diseases. Photoacoustic (PA) imaging has strong clinical potential because of its sensitivity to hemoglobin. We used a hand-held PA probe with integrated diode lasers and examined its feasibility and validity in the detection of increasing blood volume and (sub) dermal vascularization. Blood volume detection was tested in custom-made perfusion phantoms. Results showed that an increase of blood volume in a physiological range of 1.3% to 5.4% could be detected. The results were validated with power Doppler sonography. Using a motorized scanning setup, areas of the skin were imaged at relatively short scanning times () with PA. Three-dimensional visualization of these structures was achieved by combining the consecutively acquired cross-sectional images. Images revealed the epidermis and submillimeter vasculature up to depth of 5 mm. The geometries of imaged vasculature were validated with segmentation of the vasculature in high-frequency ultrasound imaging. This study proves the feasibility of PA imaging in its current implementation for the detection of perfusion-related parameters in skin and subdermal tissue and underlines its potential as a diagnostic tool in vascular or dermal pathologies.- 24 January 2017
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (4) , 041013
Visualization of vasculature using a hand-held photoacoustic probe: phantom and in vivo validation
Assessment of microvasculature and tissue perfusion can provide diagnostic information on local or systemic diseases. Photoacoustic (PA) imaging has strong clinical potential because of its sensitivity to hemoglobin. We used a hand-held PA probe with integrated diode lasers and examined its feasibility and validity in the detection of increasing blood volume and (sub) dermal vascularization. Blood volume detection was tested in custom-made perfusion phantoms. Results showed that an increase of blood volume in a physiological range of 1.3% to 5.4% could be detected. The results were validated with power Doppler sonography. Using a motorized scanning setup, areas of the skin were imaged at relatively short scanning times () with PA. Three-dimensional visualization of these structures was achieved by combining the consecutively acquired cross-sectional images. Images revealed the epidermis and submillimeter vasculature up to depth of 5 mm. The geometries of imaged vasculature were validated with segmentation of the vasculature in high-frequency ultrasound imaging. This study proves the feasibility of PA imaging in its current implementation for the detection of perfusion-related parameters in skin and subdermal tissue and underlines its potential as a diagnostic tool in vascular or dermal pathologies.- 23 December 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (4) , 041010
Toward the detection of intraplaque hemorrhage in carotid artery lesions using photoacoustic imaging
Photoacoustic imaging (PAI) may have the ability to reveal the composition and the anatomical structure of carotid plaques, which determines its mechanical properties and vulnerability. We used PAI and plane wave ultrasound (PUS) imaging to obtain three-dimensional (3-D) images of endarterectomy samples ex vivo and compared the results with histology to investigate the potential of PAI-based identification of intraplaque hemorrhage. Seven carotid plaque samples were obtained from patients undergoing carotid endarterectomy and imaged with a fully integrated hand-held photoacoustic (PA) probe, consisting of a pulsed diode laser (, , ) and a linear array transducer (). The samples were rotated 360 deg with 10 deg steps, and data were spatially compounded to obtain complete 3-D images of the plaques. Areas of high absorption in the 3-D datasets were identified and compared to histological data of the plaques. Data in six out of seven endarterectomy samples revealed the presence of intraplaque hemorrhages that were not visible in the PUS images. Due to the noninvasive nature of PAI, this ex vivo study may elucidate preclinical studies toward the in vivo, noninvasive, vulnerability assessment of the atherosclerotic carotid plaque.- 23 December 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (4) , 041010
Toward the detection of intraplaque hemorrhage in carotid artery lesions using photoacoustic imaging
Photoacoustic imaging (PAI) may have the ability to reveal the composition and the anatomical structure of carotid plaques, which determines its mechanical properties and vulnerability. We used PAI and plane wave ultrasound (PUS) imaging to obtain three-dimensional (3-D) images of endarterectomy samples ex vivo and compared the results with histology to investigate the potential of PAI-based identification of intraplaque hemorrhage. Seven carotid plaque samples were obtained from patients undergoing carotid endarterectomy and imaged with a fully integrated hand-held photoacoustic (PA) probe, consisting of a pulsed diode laser (, , ) and a linear array transducer (). The samples were rotated 360 deg with 10 deg steps, and data were spatially compounded to obtain complete 3-D images of the plaques. Areas of high absorption in the 3-D datasets were identified and compared to histological data of the plaques. Data in six out of seven endarterectomy samples revealed the presence of intraplaque hemorrhages that were not visible in the PUS images. Due to the noninvasive nature of PAI, this ex vivo study may elucidate preclinical studies toward the in vivo, noninvasive, vulnerability assessment of the atherosclerotic carotid plaque.