Morteza Alipanah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Morteza Alipanah has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Amber O’COnnor
Department of Environmental and Global Health, College of Public Health and Health Professions, University of Florida
1 shared publication- Amin Shirkhani
Department of Environmental Engineering Sciences, University of Florida
1 shared publication Carlos Manzanas
Department of Mechanical and Aerospace Engineering, University of Florida
1 shared publication- Chang-Yu Wu
Department of Chemical, Environmental, and Materials Engineering, University of Miami, Coral Gables, Florida, USA
1 shared publication - Chih-Hsiang Chien
Center for Research and Technology, Altria Client Services LLC
1 shared publication - Derek Barnes
Department of Mechanical Engineering, University of Kansas, Lawrence, KS 66045
1 shared publication
Latest Publications
- Open Access
- 13 October 2025
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 60 (4) , 340-353
Development of a platform for in-situ airborne virus detection by interfacing RT-LAMP assay with a condensational growth collector
Collection and identification of airborne viruses conventionally involve two separate processes: air sampling in the field and subsequent laboratory-based detection and analyses. They are time-consuming, which delays early warnings and hinders timely implementation of public health countermeasures. In-situ virus detection methods that enable preliminary identification at the sampling site can improve timeliness, eliminating the need for sample transport and allowing rapid decision-making. Herein, we developed and evaluated an integrated system that connects a water condensation-based aerosol collector called VIVAS with an in-situ detection platform known as VLEAD. We designed and fabricated an interface to serve both as the VIVAS’ collection chamber and as a conduit for fluid transfer into the VLEAD. The design achieved over 90% collection efficiency for particles ≥3 μm after computational fluid dynamics simulation optimization, and experimental testing confirmed a physical collection efficiency of approximately 95%. When exposed to lab-generated aerosols containing human coronavirus OC43 (HCoV-OC43), the system achieved a 100% detection rate for samples containing > 103 genome equivalents (GE) of virus per sample (4–5 GE/μL, triplicates), verified by RT-qPCR. The integrated system replaced the standard Petri dish in the commercially available VIVAS and enabled seamless transfer for RT-LAMP-based detection. The limit of detection was comparable to the level at which viruses such as SARS-CoV-2 have been collected using the VIVAS during environmental sampling reported in other studies. That performance demonstrated strong potential for rapid, in-situ detection of airborne coronaviruses and potentially other viruses in field settings or public spaces during respiratory viral disease outbreaks.
- 13 October 2025
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 60 (4) , 340-353
Open AccessDevelopment of a platform for in-situ airborne virus detection by interfacing RT-LAMP assay with a condensational growth collector
Collection and identification of airborne viruses conventionally involve two separate processes: air sampling in the field and subsequent laboratory-based detection and analyses. They are time-consuming, which delays early warnings and hinders timely implementation of public health countermeasures. In-situ virus detection methods that enable preliminary identification at the sampling site can improve timeliness, eliminating the need for sample transport and allowing rapid decision-making. Herein, we developed and evaluated an integrated system that connects a water condensation-based aerosol collector called VIVAS with an in-situ detection platform known as VLEAD. We designed and fabricated an interface to serve both as the VIVAS’ collection chamber and as a conduit for fluid transfer into the VLEAD. The design achieved over 90% collection efficiency for particles ≥3 μm after computational fluid dynamics simulation optimization, and experimental testing confirmed a physical collection efficiency of approximately 95%. When exposed to lab-generated aerosols containing human coronavirus OC43 (HCoV-OC43), the system achieved a 100% detection rate for samples containing > 103 genome equivalents (GE) of virus per sample (4–5 GE/μL, triplicates), verified by RT-qPCR. The integrated system replaced the standard Petri dish in the commercially available VIVAS and enabled seamless transfer for RT-LAMP-based detection. The limit of detection was comparable to the level at which viruses such as SARS-CoV-2 have been collected using the VIVAS during environmental sampling reported in other studies. That performance demonstrated strong potential for rapid, in-situ detection of airborne coronaviruses and potentially other viruses in field settings or public spaces during respiratory viral disease outbreaks.
- Open Access
Heat Generation Characteristics of LiFePO4 Pouch Cells with Passive Thermal Management
This article experimentally investigates the heat generation characteristics and the effectiveness of passive cooling of commercially available LiFePO4 (7.25 mm × 160 mm × 227 mm, 19.5 Ah) cells using different cooling materials. The specific heat capacity and the entropy coefficient of the cell are experimentally measured. The heat generation rate of the cell at 1–4 C current rates are also determined using three different methods: (1) the heat absorption calculated from the temperature increase of cooling water; (2) the energy loss calculated from the difference between the operating voltage and open circuit voltage; and (3) the energy loss during a charge-discharge cycle calculated using the voltage difference between charging and discharging. Results show that the heat generation rate estimated from heat absorbed by the water can be underestimated by up to 47.8% because of the temperature gradient within the cell and on the surface. The effectiveness of different passive cooling materials is compared at discharge current rates of 1–3 C. The average increase of the cell surface temperature is 22.6, 17.1, 7.7, 7.2 and 6.4 °C at 3 C (58.5 A) using air, aluminum foam, octadecane, water with aluminum foam and water, respectively.
Open AccessHeat Generation Characteristics of LiFePO4 Pouch Cells with Passive Thermal Management
This article experimentally investigates the heat generation characteristics and the effectiveness of passive cooling of commercially available LiFePO4 (7.25 mm × 160 mm × 227 mm, 19.5 Ah) cells using different cooling materials. The specific heat capacity and the entropy coefficient of the cell are experimentally measured. The heat generation rate of the cell at 1–4 C current rates are also determined using three different methods: (1) the heat absorption calculated from the temperature increase of cooling water; (2) the energy loss calculated from the difference between the operating voltage and open circuit voltage; and (3) the energy loss during a charge-discharge cycle calculated using the voltage difference between charging and discharging. Results show that the heat generation rate estimated from heat absorbed by the water can be underestimated by up to 47.8% because of the temperature gradient within the cell and on the surface. The effectiveness of different passive cooling materials is compared at discharge current rates of 1–3 C. The average increase of the cell surface temperature is 22.6, 17.1, 7.7, 7.2 and 6.4 °C at 3 C (58.5 A) using air, aluminum foam, octadecane, water with aluminum foam and water, respectively.