Felix Pierre Kuhn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Felix Pierre Kuhn has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
Antoine Feydy
Service de radiologie B, AP-HP, centre hospitalier universitaire Cochin, faculté de médecine, université Paris Descartes, 75679 Paris, France; Inserm, U1153 Epidemiology and Biostatistics Sorbonne Paris Cité Center (CRESS), épidémiologie clinique appliquées aux maladies ostéo-articulaires (Ecamo), université Paris Descartes, 75679 Paris, France
2 shared publicationsDaniel T. Schmid
University Hospital Zürich
2 shared publicationsDavid W. Crook
University Hospital Zürich
2 shared publicationsJelena R. Ghadri
2 shared publications- Marie-Martine Lefèvre-Colau
Department of Physical Medicine and Rehabilitation, Corentin-Celton Hospital (AP-HP), Paris Descartes University, Issy-les-Moulineaux, France
2 shared publications Michael Fiechter
2 shared publications
Latest Publications
- Open Access
- 26 November 2025
- Published by Springer Nature in Periodontal and Implant Research
- Vol. 9 (1) , 19
Close-meshed MRIs follow-ups for dynamic healing evaluation after tooth extraction: a proof-of-concept case
To apply a close-meshed magnetic resonance imaging (MRI) protocol for socket healing — with or without alveolar ridge preservation — and discuss the advantages and disadvantages as compared to computed tomography (CT). A molar (tooth 36) was atraumatically extracted and the mesial socket was filled with a xenograft, while the distal was left for spontaneous healing; the socket orifice was covered with a collagen membrane. MRIs were taken preoperatively (t0) and 1 (t1), 2 (t2), 4 (t3), 8 (t4), and 16 (t5) weeks after tooth extraction, respectively. At t0 and t5, the patient received CT scans for comparison. MRI and CT images were used for the analysis and comparison of extraction socket healing at different time points. Image data were processed with 3D segmentation software. Socket healing was uneventful and could be tracked within MRI. Bone volume (cm 3 ) constantly reduced from 4.83 (t0) to 4.15 (t16) for MRI over time. MRI may be suitable for imaging in different dental applications. Using this radiation-free technology might allow a more stringent and frequent follow-up in practice and, especially, in clinical trials. Technique-inherent limitations need to be considered.
- 26 November 2025
- Published by Springer Nature in Periodontal and Implant Research
- Vol. 9 (1) , 19
Open AccessClose-meshed MRIs follow-ups for dynamic healing evaluation after tooth extraction: a proof-of-concept case
To apply a close-meshed magnetic resonance imaging (MRI) protocol for socket healing — with or without alveolar ridge preservation — and discuss the advantages and disadvantages as compared to computed tomography (CT). A molar (tooth 36) was atraumatically extracted and the mesial socket was filled with a xenograft, while the distal was left for spontaneous healing; the socket orifice was covered with a collagen membrane. MRIs were taken preoperatively (t0) and 1 (t1), 2 (t2), 4 (t3), 8 (t4), and 16 (t5) weeks after tooth extraction, respectively. At t0 and t5, the patient received CT scans for comparison. MRI and CT images were used for the analysis and comparison of extraction socket healing at different time points. Image data were processed with 3D segmentation software. Socket healing was uneventful and could be tracked within MRI. Bone volume (cm 3 ) constantly reduced from 4.83 (t0) to 4.15 (t16) for MRI over time. MRI may be suitable for imaging in different dental applications. Using this radiation-free technology might allow a more stringent and frequent follow-up in practice and, especially, in clinical trials. Technique-inherent limitations need to be considered.
- 1 February 2017
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 44 (1) , 38-43
Prevalence of simple and complex sacral perineural Tarlov cysts in a French cohort of adults and children
- 1 February 2017
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 44 (1) , 38-43
Prevalence of simple and complex sacral perineural Tarlov cysts in a French cohort of adults and children
- 1 January 2017
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (1) , 20160280
MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T
Objectives:To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol.Methods:Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively.Results:TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed si...
- 1 January 2017
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (1) , 20160280
MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T
Objectives:To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol.Methods:Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively.Results:TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed si...
- 8 June 2016
- Published by Springer Nature in Neuroradiology
- Vol. 58 (9) , 929-935
Kinetic DTI of the cervical spine: diffusivity changes in healthy subjects
The study aims to assess the influence of neck extension on water diffusivity within the cervical spinal cord.
- 8 June 2016
- Published by Springer Nature in Neuroradiology
- Vol. 58 (9) , 929-935
Kinetic DTI of the cervical spine: diffusivity changes in healthy subjects
The study aims to assess the influence of neck extension on water diffusivity within the cervical spinal cord.
- Open Access
- 8 February 2016
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (2) , 393-400
MR neurographic orthopantomogram: Ultrashort echo‐time imaging of mandibular bone and teeth complemented with high‐resolution morphological and functional MR neurography
Purpose: Panoramical radiographs or cone‐beam computed tomography (CT) are the standard‐of‐care in dental imaging to assess teeth, mandible, and mandibular canal pathologies, but do not allow assessment of the inferior alveolar nerve itself nor of its branches. We propose a new technique for “MR neurographic orthopantomograms” exploiting ultrashort echo‐time (UTE) imaging of bone and teeth complemented with high‐resolution morphological and functional MR neurography.Materials and Methods: The Institutional Review Board approved the study in 10 healthy volunteers. Imaging of the subjects mandibles at 3.0T (Magnetom Skyra, Siemens‐Healthcare) using a 64‐channel head coil with isotropic spatial resolution for subsequent multiplanar reformatting, was performed. Bone images were acquired using a 3D PETRA sequence (TE, 0.07 msec). Morphological nerve imaging was performed using a dedicated 3D PSIF and 3D SPACE STIR sequence. Functional MR neurography was accomplished using a new accelerated diffusion‐tensor‐imaging (DTI) prototype sequence (2D SMS‐accelerated RESOLVE). Qualitative and quantitative image analysis was performed and descriptive statistics are provided.Results: Image acquisition and subsequent postprocessing into the MR neurographic orthopantomogram by overlay of morphological and functional images were feasible in all 10 volunteers without artifacts. All mandibular bones and mandibular nerves were assessable and considered normal. Fiber tractography with quantitative evaluation of physiological diffusion properties of mandibular nerves yielded the following mean ± SD values: fractional anisotropy, 0.43 ± 0.07; mean diffusivity (mm2/s), 0.0014 ± 0.0002; axial diffusivity, 0.0020 ± 0.0002, and radial diffusivity, 0.0011 ± 0.0001.Conclusion: The proposed technique of MR neurographic orthopantomogram exploiting UTE imaging complemented with high‐resolution morphological and functional MR neurography was feasible and allowed comprehensive assessment of osseous texture and neural microarchitecture in a single examination. J. Magn. Reson. Imaging 2016;44:393–400.
- 8 February 2016
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (2) , 393-400
Open AccessMR neurographic orthopantomogram: Ultrashort echo‐time imaging of mandibular bone and teeth complemented with high‐resolution morphological and functional MR neurography
Purpose: Panoramical radiographs or cone‐beam computed tomography (CT) are the standard‐of‐care in dental imaging to assess teeth, mandible, and mandibular canal pathologies, but do not allow assessment of the inferior alveolar nerve itself nor of its branches. We propose a new technique for “MR neurographic orthopantomograms” exploiting ultrashort echo‐time (UTE) imaging of bone and teeth complemented with high‐resolution morphological and functional MR neurography.Materials and Methods: The Institutional Review Board approved the study in 10 healthy volunteers. Imaging of the subjects mandibles at 3.0T (Magnetom Skyra, Siemens‐Healthcare) using a 64‐channel head coil with isotropic spatial resolution for subsequent multiplanar reformatting, was performed. Bone images were acquired using a 3D PETRA sequence (TE, 0.07 msec). Morphological nerve imaging was performed using a dedicated 3D PSIF and 3D SPACE STIR sequence. Functional MR neurography was accomplished using a new accelerated diffusion‐tensor‐imaging (DTI) prototype sequence (2D SMS‐accelerated RESOLVE). Qualitative and quantitative image analysis was performed and descriptive statistics are provided.Results: Image acquisition and subsequent postprocessing into the MR neurographic orthopantomogram by overlay of morphological and functional images were feasible in all 10 volunteers without artifacts. All mandibular bones and mandibular nerves were assessable and considered normal. Fiber tractography with quantitative evaluation of physiological diffusion properties of mandibular nerves yielded the following mean ± SD values: fractional anisotropy, 0.43 ± 0.07; mean diffusivity (mm2/s), 0.0014 ± 0.0002; axial diffusivity, 0.0020 ± 0.0002, and radial diffusivity, 0.0011 ± 0.0001.Conclusion: The proposed technique of MR neurographic orthopantomogram exploiting UTE imaging complemented with high‐resolution morphological and functional MR neurography was feasible and allowed comprehensive assessment of osseous texture and neural microarchitecture in a single examination. J. Magn. Reson. Imaging 2016;44:393–400.
- 1 May 2015
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 24 (5) , 965-971
Quantitative H2[15O]-PET in Pediatric Moyamoya Disease: Evaluating Perfusion before and after Cerebral Revascularization
- 1 May 2015
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 24 (5) , 965-971
Quantitative H2[15O]-PET in Pediatric Moyamoya Disease: Evaluating Perfusion before and after Cerebral Revascularization
- Open Access
- 1 January 2014
- Published by Springer Nature in EJNMMI Research
- Vol. 4 (1) , 7
Comparison of PET template-based and MRI-based image processing in the quantitative analysis of C11-raclopride PET
Quantitative measures of 11C-raclopride receptor binding can be used as a correlate of postsynaptic D2 receptor density in the striatum, allowing 11C-raclopride positron emission tomography (PET) to be used for the differentiation of Parkinson’s disease from atypical parkinsonian syndromes. Comparison with reference values is recommended to establish a reliable diagnosis. A PET template specific to raclopride may facilitate direct computation of parametric maps without the need for an additional MR scan, aiding automated image analysis.
- 1 January 2014
- Published by Springer Nature in EJNMMI Research
- Vol. 4 (1) , 7
Open AccessComparison of PET template-based and MRI-based image processing in the quantitative analysis of C11-raclopride PET
Quantitative measures of 11C-raclopride receptor binding can be used as a correlate of postsynaptic D2 receptor density in the striatum, allowing 11C-raclopride positron emission tomography (PET) to be used for the differentiation of Parkinson’s disease from atypical parkinsonian syndromes. Comparison with reference values is recommended to establish a reliable diagnosis. A PET template specific to raclopride may facilitate direct computation of parametric maps without the need for an additional MR scan, aiding automated image analysis.
- 1 September 2013
- Published by Elsevier in International Journal of Cardiology
- Vol. 167 (6) , 2932-2937
Coronary artery calcium scoring: Influence of adaptive statistical iterative reconstruction using 64-MDCT
- 1 September 2013
- Published by Elsevier in International Journal of Cardiology
- Vol. 167 (6) , 2932-2937
Coronary artery calcium scoring: Influence of adaptive statistical iterative reconstruction using 64-MDCT
- 20 February 2013
- Published by Wiley in The Laryngoscope
- Vol. 123 (5) , 1210-1215
18F‐FDG‐PET/CT for the Assessment of the Contralateral Neck in Patients with Head and Neck Squamous Cell Carcinoma
Objectives/Hypothesis The aim was to compare the value of 18‐Fluoro‐Deoxyglucose (18F‐FDG) positron emission tomography (PET)/computed tomography (CT) regarding contralateral lymph node (LN) metastasis in the neck. Study Design Retrospective analysis of 61 patients staged by 18F‐FDG‐PET/CT. Methods Cytology/histology served as a reference standard. Further, metabolic midline invasion (MI) of the primary tumor and the presence of bilateral LN metastases were assessed. Results A true positive rate in the ipsilateral neck of 80% versus 65% in the contralateral neck was found (P = 0.067). Median‐standardized uptake value (SUV)‐max for suspicious LN ipsilaterally was 7.6 versus 5.8 contralaterally (P = 0.038). There was no positive correlation between metabolic MI and bilateral metastasis (P = 0.82). Conclusions The rate of true positive detected LN by 18F‐FDG‐PET/CT is less on the contralateral neck side; therefore, all suspicious LNs should be verified by cytology. A high SUV in the contralateral neck suggests metastatic disease regardless of nodal size. Metabolic MI needs to be addressed carefully as it was not predictive for bilateral LN involvement. Level of Evidence 4.
- 20 February 2013
- Published by Wiley in The Laryngoscope
- Vol. 123 (5) , 1210-1215
18F‐FDG‐PET/CT for the Assessment of the Contralateral Neck in Patients with Head and Neck Squamous Cell Carcinoma
Objectives/Hypothesis The aim was to compare the value of 18‐Fluoro‐Deoxyglucose (18F‐FDG) positron emission tomography (PET)/computed tomography (CT) regarding contralateral lymph node (LN) metastasis in the neck. Study Design Retrospective analysis of 61 patients staged by 18F‐FDG‐PET/CT. Methods Cytology/histology served as a reference standard. Further, metabolic midline invasion (MI) of the primary tumor and the presence of bilateral LN metastases were assessed. Results A true positive rate in the ipsilateral neck of 80% versus 65% in the contralateral neck was found (P = 0.067). Median‐standardized uptake value (SUV)‐max for suspicious LN ipsilaterally was 7.6 versus 5.8 contralaterally (P = 0.038). There was no positive correlation between metabolic MI and bilateral metastasis (P = 0.82). Conclusions The rate of true positive detected LN by 18F‐FDG‐PET/CT is less on the contralateral neck side; therefore, all suspicious LNs should be verified by cytology. A high SUV in the contralateral neck suggests metastatic disease regardless of nodal size. Metabolic MI needs to be addressed carefully as it was not predictive for bilateral LN involvement. Level of Evidence 4.
- 1 January 2013
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 43 (1) , 3-10
Clinical Positron Emission Tomography/Magnetic Resonance Imaging Applications
- 1 January 2013
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 43 (1) , 3-10
Clinical Positron Emission Tomography/Magnetic Resonance Imaging Applications