MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T
Authors:
- Felix P KuhnFKFelix P Kuhn
- Georg SpinnerGSGeorg Spinner
- Filippo Del GrandeFGFilippo Del Grande
- Michael WyssMWMichael Wyss
- Marco PiccirelliMPMarco Piccirelli
- Stefan ErniSEStefan Erni
- Pascal PfisterPPPascal Pfister
- Michael HoMHMichael Ho
- Bert-Ram SahBSBert-Ram Sah
- Lukas FilliLFLukas Filli
- Dominik A EttlinDEDominik A Ettlin
- Luigi M GalloLGLuigi M Gallo
- 1 January 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (1) , 20160280
Abstract
Objectives:To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol.Methods:Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively.Results:TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed si...Keywords
This publication has 42 references indexed in Scilit:
- Dynamically applied B1+ shimming solutions for non‐contrast enhanced renal angiography at 7.0 teslaMagnetic Resonance in Medicine, 2012
- Correlating cone beam CT results with temporomandibular joint pain of osteoarthritic originDentomaxillofacial Radiology, 2012
- In vitro and in vivo comparison of wrist MR imaging at 3.0 and 7.0 tesla using a gradient echo sequence and identical eight‐channel coil array designsJournal of Magnetic Resonance Imaging, 2011
- Research diagnostic criteria for temporomandibular disorders (RDC/TMD): development of image analysis criteria and examiner reliability for image analysisOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2009
- Mechanically adjustable coil array for wrist MRIMagnetic Resonance in Medicine, 2009
- Slice‐selective RF pulses for in vivo B inhomogeneity mitigation at 7 tesla using parallel RF excitation with a 16‐element coilMagnetic Resonance in Medicine, 2008
- Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channelsMagnetic Resonance in Medicine, 2008
- Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject‐dependent transmit phase measurementsMagnetic Resonance in Medicine, 2008
- Small tip angle three‐dimensional tailored radiofrequency slab‐select pulse for reduced B1 inhomogeneity at 3 TMagnetic Resonance in Medicine, 2005
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999