Manfred Franke
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Manfred Franke has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Andrew J. Shoffstall
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA
3 shared publications - Douglas J. Weber
Carnegie Mellon University
3 shared publications - James K. Trevathan
University of Wisconsin-Madison
3 shared publications - Kip A. Ludwig
Department of Neurological Surgery, University of Wisconsin – Madison
3 shared publications - Stephan Nieuwoudt
Neuronoff Inc, 11000 Cedar Ave, Cleveland, 44106, UNITED STATES
3 shared publications - Ashley N. Dalrymple
University of Utah
2 shared publications
Latest Publications
- Open Access
- 13 June 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (6) , 611
Removal Forces of a Helical Microwire Structure Electrode
(1) Background: Medical devices, especially neuromodulation devices, are often explanted for a variety of reasons. The removal process imparts significant forces on these devices, which may result in device fracture and tissue trauma. We hypothesized that a device’s form factor interfacing with tissue is a major driver of the force required to remove a device, and we isolated helical and linear electrode structures as a means to study atraumatic removal. (2) Methods: Ductile linear and helical microwire structure electrodes were fabricated from either Gold (Au) or Platinum–Iridium (Pt-Ir, 90-10). Removal forces were captured from synthetic gel models and following chronic implantation in rodent and porcine models. Devices were fully implanted in the animal models, requiring a small incision (<10 mm) and removal via tissue forceps. (3) Results: Helical devices were shown to result in significantly lower maximal removal forces in both synthetic gel and rodent studies compared to their linear counterparts. Chronically (1 yr.), the maximal removal force of helical devices remained under 7.30 N, for which the Platinum–Iridium device’s tensile failure force was 32.90 ± 2.09 N, resulting in a safety factor of 4.50. (4) Conclusions: An open-core helical structure that can freely elongate was shown to result in reduced removal forces both acutely and chronically.
- 13 June 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (6) , 611
Open AccessRemoval Forces of a Helical Microwire Structure Electrode
(1) Background: Medical devices, especially neuromodulation devices, are often explanted for a variety of reasons. The removal process imparts significant forces on these devices, which may result in device fracture and tissue trauma. We hypothesized that a device’s form factor interfacing with tissue is a major driver of the force required to remove a device, and we isolated helical and linear electrode structures as a means to study atraumatic removal. (2) Methods: Ductile linear and helical microwire structure electrodes were fabricated from either Gold (Au) or Platinum–Iridium (Pt-Ir, 90-10). Removal forces were captured from synthetic gel models and following chronic implantation in rodent and porcine models. Devices were fully implanted in the animal models, requiring a small incision (<10 mm) and removal via tissue forceps. (3) Results: Helical devices were shown to result in significantly lower maximal removal forces in both synthetic gel and rodent studies compared to their linear counterparts. Chronically (1 yr.), the maximal removal force of helical devices remained under 7.30 N, for which the Platinum–Iridium device’s tensile failure force was 32.90 ± 2.09 N, resulting in a safety factor of 4.50. (4) Conclusions: An open-core helical structure that can freely elongate was shown to result in reduced removal forces both acutely and chronically.
- Open Access
- 4 November 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 056068
Stimulation of the dorsal root ganglion using an Injectrode®
Objective. The goal of this work was to compare afferent fiber recruitment by dorsal root ganglion (DRG) stimulation using an injectable polymer electrode (Injectrode®) and a more traditional cylindrical metal electrode. Approach. We exposed the L6 and L7 DRG in four cats via a partial laminectomy or burr hole. We stimulated the DRG using an Injectrode or a stainless steel (SS) electrode using biphasic pulses at three different pulse widths (80, 150, 300 μs) and pulse amplitudes spanning the range used for clinical DRG stimulation. We recorded antidromic evoked compound action potentials (ECAPs) in the sciatic, tibial, and common peroneal nerves using nerve cuffs. We calculated the conduction velocity of the ECAPs and determined the charge-thresholds and recruitment rates for ECAPs from Aα, Aβ, and Aδ fibers. We also performed electrochemical impedance spectroscopy measurements for both electrode types. Main results. The ECAP thresholds for the Injectrode did not differ from the SS electrode across all primary afferents (Aα, Aβ, Aδ) and pulse widths; charge-thresholds increased with wider pulse widths. Thresholds for generating ECAPs from Aβ fibers were 100.0 ± 32.3 nC using the SS electrode, and 90.9 ± 42.9 nC using the Injectrode. The ECAP thresholds from the Injectrode were consistent over several hours of stimulation. The rate of recruitment was similar between the Injectrodes and SS electrode and decreased with wider pulse widths. Significance. The Injectrode can effectively excite primary afferents when used for DRG stimulation within the range of parameters used for clinical DRG stimulation. The Injectrode can be implanted through minimally invasive techniques while achieving similar neural activation to conventional electrodes, making it an excellent candidate for future DRG stimulation and neuroprosthetic applications.
- 4 November 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 056068
Open AccessStimulation of the dorsal root ganglion using an Injectrode®
Objective. The goal of this work was to compare afferent fiber recruitment by dorsal root ganglion (DRG) stimulation using an injectable polymer electrode (Injectrode®) and a more traditional cylindrical metal electrode. Approach. We exposed the L6 and L7 DRG in four cats via a partial laminectomy or burr hole. We stimulated the DRG using an Injectrode or a stainless steel (SS) electrode using biphasic pulses at three different pulse widths (80, 150, 300 μs) and pulse amplitudes spanning the range used for clinical DRG stimulation. We recorded antidromic evoked compound action potentials (ECAPs) in the sciatic, tibial, and common peroneal nerves using nerve cuffs. We calculated the conduction velocity of the ECAPs and determined the charge-thresholds and recruitment rates for ECAPs from Aα, Aβ, and Aδ fibers. We also performed electrochemical impedance spectroscopy measurements for both electrode types. Main results. The ECAP thresholds for the Injectrode did not differ from the SS electrode across all primary afferents (Aα, Aβ, Aδ) and pulse widths; charge-thresholds increased with wider pulse widths. Thresholds for generating ECAPs from Aβ fibers were 100.0 ± 32.3 nC using the SS electrode, and 90.9 ± 42.9 nC using the Injectrode. The ECAP thresholds from the Injectrode were consistent over several hours of stimulation. The rate of recruitment was similar between the Injectrodes and SS electrode and decreased with wider pulse widths. Significance. The Injectrode can effectively excite primary afferents when used for DRG stimulation within the range of parameters used for clinical DRG stimulation. The Injectrode can be implanted through minimally invasive techniques while achieving similar neural activation to conventional electrodes, making it an excellent candidate for future DRG stimulation and neuroprosthetic applications.
- Open Access
Stimulation of the Dorsal Root Ganglion using an Injectrode ®
Objective: The goal of this work was to compare afferent fiber recruitment by dorsal root ganglion (DRG) stimulation using an injectable polymer electrode (Injectrode ® ) and a more traditional cylindrical metal electrode. Approach: We exposed the L6 and L7 DRG in four cats via a partial laminectomy or burr hole. We stimulated the DRG using an Injectrode or a stainless steel electrode using biphasic pulses at three different pulse widths (80, 150, 300 μs) and pulse amplitudes spanning the range used for clinical DRG stimulation. We recorded antidromic evoked compound action potentials (ECAPs) in the sciatic, tibial, and common peroneal nerves using nerve cuffs. We calculated the conduction velocity of the ECAPs and determined the charge-thresholds and recruitment rates for ECAPs from Aα, Aβ, and Aδ fibers. We also performed electrochemical impedance spectroscopy measurements for both electrode types. Main Results: The ECAP thresholds for the Injectrode did not differ from the stainless steel electrode across all primary afferents (Aα, Aβ, Aδ) and pulse widths; charge-thresholds increased with wider pulse widths. Thresholds for generating ECAPs from Aβ fibers were 100.0 ± 32.3 nC using the stainless steel electrode, and 90.9 ± 42.9 nC using the Injectrode. The ECAP thresholds from the Injectrode were consistent over several hours of stimulation. The rate of recruitment was similar between the Injectrodes and stainless steel electrode and decreased with wider pulse widths. Significance: The Injectrode can effectively excite primary afferents when used for DRG stimulation within the range of parameters used for clinical DRG stimulation. The Injectrode can be implanted through minimally invasive techniques while achieving similar neural activation to conventional electrodes, making it an excellent candidate for future DRG stimulation and neuroprosthetic applications.
Open AccessStimulation of the Dorsal Root Ganglion using an Injectrode ®
Objective: The goal of this work was to compare afferent fiber recruitment by dorsal root ganglion (DRG) stimulation using an injectable polymer electrode (Injectrode ® ) and a more traditional cylindrical metal electrode. Approach: We exposed the L6 and L7 DRG in four cats via a partial laminectomy or burr hole. We stimulated the DRG using an Injectrode or a stainless steel electrode using biphasic pulses at three different pulse widths (80, 150, 300 μs) and pulse amplitudes spanning the range used for clinical DRG stimulation. We recorded antidromic evoked compound action potentials (ECAPs) in the sciatic, tibial, and common peroneal nerves using nerve cuffs. We calculated the conduction velocity of the ECAPs and determined the charge-thresholds and recruitment rates for ECAPs from Aα, Aβ, and Aδ fibers. We also performed electrochemical impedance spectroscopy measurements for both electrode types. Main Results: The ECAP thresholds for the Injectrode did not differ from the stainless steel electrode across all primary afferents (Aα, Aβ, Aδ) and pulse widths; charge-thresholds increased with wider pulse widths. Thresholds for generating ECAPs from Aβ fibers were 100.0 ± 32.3 nC using the stainless steel electrode, and 90.9 ± 42.9 nC using the Injectrode. The ECAP thresholds from the Injectrode were consistent over several hours of stimulation. The rate of recruitment was similar between the Injectrodes and stainless steel electrode and decreased with wider pulse widths. Significance: The Injectrode can effectively excite primary afferents when used for DRG stimulation within the range of parameters used for clinical DRG stimulation. The Injectrode can be implanted through minimally invasive techniques while achieving similar neural activation to conventional electrodes, making it an excellent candidate for future DRG stimulation and neuroprosthetic applications.
- Open Access
A Truly Injectable Neural Stimulation Electrode Made from an In-Body Curing Polymer/Metal Composite
Implanted neural stimulation and recording devices hold vast potential to treat a variety of neurological conditions, but the invasiveness, complexity, and cost of the implantation procedure greatly reduce access to an otherwise promising therapeutic approach. To address this need, we have developed a novel electrode that begins as an uncured, flowable pre-polymer that can be injected around a neuroanatomical target to minimize surgical manipulation. Referred to as the Injectrode, the electrode conforms to target structures forming an electrically conductive interface which is orders of magnitude less stiff than conventional neuromodulation electrodes. To validate the Injectrode, we performed detailed electrochemical and microscopy characterization of its material properties and validated the feasibility of using it to electrically stimulate the nervous system in rats and swine. The silicone-metal-particle composite performed very similarly to pure wire of the same metal (silver) in all measures, including exhibiting a favorable cathodic charge storage capacity (CSC C ) and charge injection limits compared to the clinical LivaNova stimulation electrode and silver wire electrodes. By virtue of being simpler than traditional electrode designs, less invasive, and more cost-effective, the Injectrode has the potential to increase the adoption of neuromodulation therapies for existing and new indications.
Open AccessA Truly Injectable Neural Stimulation Electrode Made from an In-Body Curing Polymer/Metal Composite
Implanted neural stimulation and recording devices hold vast potential to treat a variety of neurological conditions, but the invasiveness, complexity, and cost of the implantation procedure greatly reduce access to an otherwise promising therapeutic approach. To address this need, we have developed a novel electrode that begins as an uncured, flowable pre-polymer that can be injected around a neuroanatomical target to minimize surgical manipulation. Referred to as the Injectrode, the electrode conforms to target structures forming an electrically conductive interface which is orders of magnitude less stiff than conventional neuromodulation electrodes. To validate the Injectrode, we performed detailed electrochemical and microscopy characterization of its material properties and validated the feasibility of using it to electrically stimulate the nervous system in rats and swine. The silicone-metal-particle composite performed very similarly to pure wire of the same metal (silver) in all measures, including exhibiting a favorable cathodic charge storage capacity (CSC C ) and charge injection limits compared to the clinical LivaNova stimulation electrode and silver wire electrodes. By virtue of being simpler than traditional electrode designs, less invasive, and more cost-effective, the Injectrode has the potential to increase the adoption of neuromodulation therapies for existing and new indications.
- 11 September 2015
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 54 (1) , 191-203
Characterization of high capacitance electrodes for the application of direct current electrical nerve block
Direct current (DC) can briefly produce a reversible nerve conduction block in acute experiments. However, irreversible reactions at the electrode–tissue interface have prevented its use in both acute and chronic settings. A high capacitance material (platinum black) using a charge-balanced waveform was evaluated to determine whether brief DC block (13 s) could be achieved repeatedly (>100 cycles) without causing acute irreversible reduction in nerve conduction. Electrochemical techniques were used to characterize the electrodes to determine appropriate waveform parameters. In vivo experiments on DC motor conduction block of the rat sciatic nerve were performed to characterize the acute neural response to this novel nerve block system. Complete nerve motor conduction block of the rat sciatic nerve was possible in all experiments, with the block threshold ranging from −0.15 to −3.0 mA. DC pulses were applied for 100 cycles with no nerve conduction reduction in four of the six platinum black electrodes tested. However, two of the six electrodes exhibited irreversible conduction degradation despite charge delivery that was within the initial Q (capacitance) value of the electrode. Degradation of material properties occurred in all experiments, pointing to a possible cause of the reduction in nerve conduction in some platinum black experiments .
- 11 September 2015
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 54 (1) , 191-203
Characterization of high capacitance electrodes for the application of direct current electrical nerve block
Direct current (DC) can briefly produce a reversible nerve conduction block in acute experiments. However, irreversible reactions at the electrode–tissue interface have prevented its use in both acute and chronic settings. A high capacitance material (platinum black) using a charge-balanced waveform was evaluated to determine whether brief DC block (13 s) could be achieved repeatedly (>100 cycles) without causing acute irreversible reduction in nerve conduction. Electrochemical techniques were used to characterize the electrodes to determine appropriate waveform parameters. In vivo experiments on DC motor conduction block of the rat sciatic nerve were performed to characterize the acute neural response to this novel nerve block system. Complete nerve motor conduction block of the rat sciatic nerve was possible in all experiments, with the block threshold ranging from −0.15 to −3.0 mA. DC pulses were applied for 100 cycles with no nerve conduction reduction in four of the six platinum black electrodes tested. However, two of the six electrodes exhibited irreversible conduction degradation despite charge delivery that was within the initial Q (capacitance) value of the electrode. Degradation of material properties occurred in all experiments, pointing to a possible cause of the reduction in nerve conduction in some platinum black experiments .
- 1 July 2014
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 232, 74-83
Direct current contamination of kilohertz frequency alternating current waveforms
- 1 July 2014
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 232, 74-83
Direct current contamination of kilohertz frequency alternating current waveforms
- 1 February 2009
- Published by Georg Thieme Verlag KG in Klinische Padiatrie
- Vol. 221 (02) , A84
Neue Therapiemöglichkeit problematischer Hämangiome – Propranolol: erste klinische Erfahrungen
Hintergrund: Große Hämangiome im Gesichtsbereich und an ähnlichen kritischen Stellen stellen häufig ein therapeutisches Dilemma dar. Interstitielle Lasertherapie, eventuell Exzision oder Kortison waren bisher die bestmöglichen Therapieoptionen, welche häufig zu unbefriedigenden Ergebnissen führten. Im Juni 2008 wurde in Frankreich durch Zufall entdeckt, dass der Betablocker Propranolol Hämangiome zur Rückbildung bringen kann (New Engl. J Med, 338; 24; 2008). Seit November 2008 wendet die Kinderchirurgie des Olgahospitals diese Therapiemöglichkeit in ausgewählten Fällen an. Methodik: Anwendung der Propranololtherapie bei Kindern mit großflächigen Hämangiomen im Gesichtsbereich sowie großflächigen Hämangiomen an den Extremitäten und am Rumpf. Nach erfolgter kardiologischer Abklärung mittels EKG, Langezeit-EKG sowie Echo und Abdomensonografie (zum Ausschluss intraabdomineller Hämangiome) erfolgt der Beginn der Propranololtherapie mit 1mg/kgKG unter Überwachung der Vitalparameter. Am zweiten Tag Steigerung auf 2mg/kgKG. Anschließend Fortführen der Therapie mit 2mg/kgKG für vier bis sechs Monate. Dabei regelmäßige Verlaufskontrollen mit Fotodokumentation. Ergebnisse: Die Wirkung der Therapie wird anhand von Fotodokumentation, Vermessung und Duplexsonografie dargestellt. Bei den bisherigen Fällen decken sich die guten Ergebnisse mit denen der Literatur; Nebenwirkungen sind bislang nicht aufgetreten. Schlussfolgerung: Propranololtherapie bei Hämangiomen scheint ein vielversprechender Therapieansatz zu sein; Verträglichkeit und Wirksamkeit sollen im Rahmen einer großen Multicenter-Studie in Süddeutschland gründlich untersucht werden.
- 1 February 2009
- Published by Georg Thieme Verlag KG in Klinische Padiatrie
- Vol. 221 (02) , A84
Neue Therapiemöglichkeit problematischer Hämangiome – Propranolol: erste klinische Erfahrungen
Hintergrund: Große Hämangiome im Gesichtsbereich und an ähnlichen kritischen Stellen stellen häufig ein therapeutisches Dilemma dar. Interstitielle Lasertherapie, eventuell Exzision oder Kortison waren bisher die bestmöglichen Therapieoptionen, welche häufig zu unbefriedigenden Ergebnissen führten. Im Juni 2008 wurde in Frankreich durch Zufall entdeckt, dass der Betablocker Propranolol Hämangiome zur Rückbildung bringen kann (New Engl. J Med, 338; 24; 2008). Seit November 2008 wendet die Kinderchirurgie des Olgahospitals diese Therapiemöglichkeit in ausgewählten Fällen an. Methodik: Anwendung der Propranololtherapie bei Kindern mit großflächigen Hämangiomen im Gesichtsbereich sowie großflächigen Hämangiomen an den Extremitäten und am Rumpf. Nach erfolgter kardiologischer Abklärung mittels EKG, Langezeit-EKG sowie Echo und Abdomensonografie (zum Ausschluss intraabdomineller Hämangiome) erfolgt der Beginn der Propranololtherapie mit 1mg/kgKG unter Überwachung der Vitalparameter. Am zweiten Tag Steigerung auf 2mg/kgKG. Anschließend Fortführen der Therapie mit 2mg/kgKG für vier bis sechs Monate. Dabei regelmäßige Verlaufskontrollen mit Fotodokumentation. Ergebnisse: Die Wirkung der Therapie wird anhand von Fotodokumentation, Vermessung und Duplexsonografie dargestellt. Bei den bisherigen Fällen decken sich die guten Ergebnisse mit denen der Literatur; Nebenwirkungen sind bislang nicht aufgetreten. Schlussfolgerung: Propranololtherapie bei Hämangiomen scheint ein vielversprechender Therapieansatz zu sein; Verträglichkeit und Wirksamkeit sollen im Rahmen einer großen Multicenter-Studie in Süddeutschland gründlich untersucht werden.