Belén García
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Belén García has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Andrés Montero
Lecturer of the Department of Electrical Engineering, Universidad Carlos III de Madrid, Madrid, Spain
9 shared publications - Juan Carlos Burgos
Department of Electrical Engineering, Universidad Carlos III de Madrid, Leganés, Spain
8 shared publications - Diego Fernando Garcia
School of Electrical and Electronic Engineering, Universidad del Valle, Cali 760032, Colombia
7 shared publications - Daniel Pérez-Rosa
Electrical Engineering Department, Universidad Carlos III de Madrid, Leganés, 28911 Madrid, Spain
6 shared publications - Juan Carlos Cabanelas
Universidad Carlos III de Madrid
3 shared publications - Guillermo Robles
Department of Electrical Engineering, University Carlos III of Madrid, 28911 Leganés, Spain
2 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Quantitative determination of residual mineral oil in ester-Retrofilled transformers using Fourier-Transform infrared spectroscopy
- 30 September 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Open AccessQuantitative determination of residual mineral oil in ester-Retrofilled transformers using Fourier-Transform infrared spectroscopy
- Open Access
- 31 July 2026
- Published by Elsevier in SSRN Electronic Journal
Quantitative Determination of Residual Mineral Oil in Ester-Retrofilled Transformers Using Fourier-Transform Infrared Spectroscopy
Power and distribution transformers are essential components in electrical systems. Transformer insulation is made of cellulose-based solid materials and dielectric liquids. Traditionally, mineral oils have served as the transformer liquid insulation, however ester-based liquids have gained attention in the last two decades being more environmentally friendly, safer in case of fire, and extend life of solid insulation. Retrofilling mineral-oil-filled transformers with these alternative liquids is used to incorporate esters to transformers on the middle of their operative life. However, a total removal of mineral oil from the transformer tank is not possible and a certain amount of this liquid always remains adsorbed in the solid insulation which, in the long term, migrates to the new insulating liquid causing contamination levels in the esters of 3 to 10% volume. These levels of mineral oil can cause a decrease in fire point of esters to values below 300C and create operational uncertainty. This paper evaluates the possible use of Attenuated Total Reflection (ATR) linked to Fourier-Transform Infrared (FTIR) spectroscopy as a method to quantify the content of mineral oil in retrofilled transformers. Mixtures of four commercial natural and synthetic esters and mineral oil were processed, and monitored using this technique. Tests were repeated considering liquids with different ageing conditions to evaluate the impact of the ageing byproducts in the possible applicability of the technique at different moments of the transformer life. The paper evaluates the accuracy of the method and provides guidance on its application and the interpretation of the results.
- 31 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessQuantitative Determination of Residual Mineral Oil in Ester-Retrofilled Transformers Using Fourier-Transform Infrared Spectroscopy
Power and distribution transformers are essential components in electrical systems. Transformer insulation is made of cellulose-based solid materials and dielectric liquids. Traditionally, mineral oils have served as the transformer liquid insulation, however ester-based liquids have gained attention in the last two decades being more environmentally friendly, safer in case of fire, and extend life of solid insulation. Retrofilling mineral-oil-filled transformers with these alternative liquids is used to incorporate esters to transformers on the middle of their operative life. However, a total removal of mineral oil from the transformer tank is not possible and a certain amount of this liquid always remains adsorbed in the solid insulation which, in the long term, migrates to the new insulating liquid causing contamination levels in the esters of 3 to 10% volume. These levels of mineral oil can cause a decrease in fire point of esters to values below 300C and create operational uncertainty. This paper evaluates the possible use of Attenuated Total Reflection (ATR) linked to Fourier-Transform Infrared (FTIR) spectroscopy as a method to quantify the content of mineral oil in retrofilled transformers. Mixtures of four commercial natural and synthetic esters and mineral oil were processed, and monitored using this technique. Tests were repeated considering liquids with different ageing conditions to evaluate the impact of the ageing byproducts in the possible applicability of the technique at different moments of the transformer life. The paper evaluates the accuracy of the method and provides guidance on its application and the interpretation of the results.
- Open Access
- 6 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Experimental Assessment of the Dielectric and Physicochemical Performance of Liquid Insulation in Retrofilled Transformers
The retrofilling of transformers with alternative oils is becoming an industrial practice to enhance the system reliability. However, the technical implications of residual mineral oil, particularly when either oil is aged, remain insufficiently explored. This paper presents a comprehensive study on the physicochemical and dielectric characteristics of oil mixtures in proportions typical of retrofilled units. A distinctive feature of this research is the evaluation of mixtures incorporating oils with different levels of degradation, providing a realistic representation of in-service transformers. AC breakdown voltage, partial discharge inception voltage, permittivity, tangent delta, acidity, density and viscosity, were characterized under both fresh and aging conditions. The experimental results reveal that most physicochemical properties change linearly with the MO mixing ratio. Dielectrically, small amounts of MO do not compromise the system’s integrity in fresh conditions; however, aging induces a critical reduction in PDIV, highlighting a potential risk for long-term operation.
- 6 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Open AccessExperimental Assessment of the Dielectric and Physicochemical Performance of Liquid Insulation in Retrofilled Transformers
The retrofilling of transformers with alternative oils is becoming an industrial practice to enhance the system reliability. However, the technical implications of residual mineral oil, particularly when either oil is aged, remain insufficiently explored. This paper presents a comprehensive study on the physicochemical and dielectric characteristics of oil mixtures in proportions typical of retrofilled units. A distinctive feature of this research is the evaluation of mixtures incorporating oils with different levels of degradation, providing a realistic representation of in-service transformers. AC breakdown voltage, partial discharge inception voltage, permittivity, tangent delta, acidity, density and viscosity, were characterized under both fresh and aging conditions. The experimental results reveal that most physicochemical properties change linearly with the MO mixing ratio. Dielectrically, small amounts of MO do not compromise the system’s integrity in fresh conditions; however, aging induces a critical reduction in PDIV, highlighting a potential risk for long-term operation.
- Open Access
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (1) , 435-443
Partial Discharge Patterns in Natural Esters From Different Vegetable Bases
Transformer insulation system is composed of solid and liquid insulation, working in conjunction for the safe, efficient and optimal performance of the equipment. The condition of these two insulation components is closely related to the life expectancy of a transformer. Mineral oil has been widely used as transformer liquid insulation, although alternative liquids of vegetable base have begun to emerge. These alternative liquids offer advantageous physic-chemical properties, including dielectric performance evaluated through high-voltage tests. This paper focuses on evaluating the partial discharge performance of four vegetable oils, comparing their properties with those of a transformer mineral oil. The study was repeated for fresh samples and for samples with different ageing degrees. Partial discharge tests were carried out in the lab using a needle-to-plane electrode system and two different test methods for applying the testing voltage. Four different interpretation criteria were used for determining the Partial Discharge Inception Voltage (PDIV) value. Electrical parameters such as PDIV, pulse repetition rate and Phase-Resolved Partial Discharge (PRPD) were measured for each oil sample. Additionally, other physic-chemical properties of the samples were measured. The results show that all the tested liquids presented a fair performance under partial discharge, although significant differences were found between them. In some cases, as for the high-oleic sunflower based natural ester, the PDIV was found to be significantly larger than that of mineral oil.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (1) , 435-443
Open AccessPartial Discharge Patterns in Natural Esters From Different Vegetable Bases
Transformer insulation system is composed of solid and liquid insulation, working in conjunction for the safe, efficient and optimal performance of the equipment. The condition of these two insulation components is closely related to the life expectancy of a transformer. Mineral oil has been widely used as transformer liquid insulation, although alternative liquids of vegetable base have begun to emerge. These alternative liquids offer advantageous physic-chemical properties, including dielectric performance evaluated through high-voltage tests. This paper focuses on evaluating the partial discharge performance of four vegetable oils, comparing their properties with those of a transformer mineral oil. The study was repeated for fresh samples and for samples with different ageing degrees. Partial discharge tests were carried out in the lab using a needle-to-plane electrode system and two different test methods for applying the testing voltage. Four different interpretation criteria were used for determining the Partial Discharge Inception Voltage (PDIV) value. Electrical parameters such as PDIV, pulse repetition rate and Phase-Resolved Partial Discharge (PRPD) were measured for each oil sample. Additionally, other physic-chemical properties of the samples were measured. The results show that all the tested liquids presented a fair performance under partial discharge, although significant differences were found between them. In some cases, as for the high-oleic sunflower based natural ester, the PDIV was found to be significantly larger than that of mineral oil.
- Open Access
- 11 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Education
- Vol. 68 (1) , 67-78
Learning Through Explanation: Producing and Peer-Reviewing Videos on Electric Circuits Problem Solving
Contributions: This article presents the results from a teaching innovation project based on the creation of educational videos by students and their assessment through blind peer review in the context of an electric circuit course. This article also analyses the activity’s impact on learning outcomes by comparing the results of participating students with nonparticipants, as well as with results from the previous years. The study includes surveys completed by students. Background: Electric circuit courses involve a cumulative learning process that advances throughout the course. Students who do not adhere to a regular study-homework routine often struggle to maximize the benefits of their class time and are more prone to test failures. Research Questions (RQs): RQ1) Can peer assessment be relied upon as a grading method in an electrical engineering course? RQ2) Is it possible to enhance students’ study routines and improve their results by incorporating assessment activities different from partial exams, such as creating educational videos and peer review assessments? Methodology: Students create videos, which are then submitted to the designated task through the Moodle workshop tool. Subsequently, peer reviews are conducted using a rubric form. The reliability of peer review is analysed by comparing the grades assigned by students with those assigned by teachers who are introduced as incognito reviewers. Findings: The evaluation system, relying on peer assessments, demonstrated fair reliability. Participants have substantially improved their academic performance while dedicating less time to preparing for the different evaluation tests.
- 11 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Education
- Vol. 68 (1) , 67-78
Open AccessLearning Through Explanation: Producing and Peer-Reviewing Videos on Electric Circuits Problem Solving
Contributions: This article presents the results from a teaching innovation project based on the creation of educational videos by students and their assessment through blind peer review in the context of an electric circuit course. This article also analyses the activity’s impact on learning outcomes by comparing the results of participating students with nonparticipants, as well as with results from the previous years. The study includes surveys completed by students. Background: Electric circuit courses involve a cumulative learning process that advances throughout the course. Students who do not adhere to a regular study-homework routine often struggle to maximize the benefits of their class time and are more prone to test failures. Research Questions (RQs): RQ1) Can peer assessment be relied upon as a grading method in an electrical engineering course? RQ2) Is it possible to enhance students’ study routines and improve their results by incorporating assessment activities different from partial exams, such as creating educational videos and peer review assessments? Methodology: Students create videos, which are then submitted to the designated task through the Moodle workshop tool. Subsequently, peer reviews are conducted using a rubric form. The reliability of peer review is analysed by comparing the grades assigned by students with those assigned by teachers who are introduced as incognito reviewers. Findings: The evaluation system, relying on peer assessments, demonstrated fair reliability. Participants have substantially improved their academic performance while dedicating less time to preparing for the different evaluation tests.
- Open Access
Life Expectancy of Transformer Paper Insulation Retrofilled with Natural Ester in the Laboratory
The use of alternative insulating liquids instead of mineral oil in transformers is spreading around the world due to their superior fire resistance. Furthermore, researchers have demonstrated that these oils increase the lifespan of the solid insulation of the transformers and, thus, the life expectancy of the equipment. Retrofilling of transformers with natural and synthetic esters allows companies to benefit from the properties of using these liquids without making an investment into new machinery. This paper investigated the ageing process of Kraft paper that was retrofilled with a natural ester in the laboratory. The Kraft paper samples were subjected to accelerated thermal ageing in an oven at 130 °C, and markers such as the degree of polymerisation and tensile strength were measured. The ageing tests comprised a first period, where the samples were immersed in mineral oil, followed by a replacement of the oil with a natural ester. As moisture is a determinant factor for paper ageing, two sets of samples with different moisture contents were tested. The results showed that the retrofilling of the transformers may slow down the degradation rate of the solid insulation despite the presence of remaining mineral oil adsorbed in the paper.
Open AccessLife Expectancy of Transformer Paper Insulation Retrofilled with Natural Ester in the Laboratory
The use of alternative insulating liquids instead of mineral oil in transformers is spreading around the world due to their superior fire resistance. Furthermore, researchers have demonstrated that these oils increase the lifespan of the solid insulation of the transformers and, thus, the life expectancy of the equipment. Retrofilling of transformers with natural and synthetic esters allows companies to benefit from the properties of using these liquids without making an investment into new machinery. This paper investigated the ageing process of Kraft paper that was retrofilled with a natural ester in the laboratory. The Kraft paper samples were subjected to accelerated thermal ageing in an oven at 130 °C, and markers such as the degree of polymerisation and tensile strength were measured. The ageing tests comprised a first period, where the samples were immersed in mineral oil, followed by a replacement of the oil with a natural ester. As moisture is a determinant factor for paper ageing, two sets of samples with different moisture contents were tested. The results showed that the retrofilling of the transformers may slow down the degradation rate of the solid insulation despite the presence of remaining mineral oil adsorbed in the paper.
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (4) , 1641-1648
Study on the Contamination Rate of Mineral Oil in Natural-Ester Retrofilled Transformers
The replacement of mineral oil by ester (retrofilling) is a practice used in power transformers to reduce fire and environmental risk. Although measures are taken to remove traces of oil on the paper, a certain amount of mineral oil remains, which migrates over time. This article presents a study to evaluate the migration of mineral oil from paper to ester using techniques such as the iodine value or the measurement of permittivity and dielectric losses.
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (4) , 1641-1648
Study on the Contamination Rate of Mineral Oil in Natural-Ester Retrofilled Transformers
The replacement of mineral oil by ester (retrofilling) is a practice used in power transformers to reduce fire and environmental risk. Although measures are taken to remove traces of oil on the paper, a certain amount of mineral oil remains, which migrates over time. This article presents a study to evaluate the migration of mineral oil from paper to ester using techniques such as the iodine value or the measurement of permittivity and dielectric losses.
- 8 December 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 105 (2) , 761-773
Power transformer temperature–moisture dynamics modeling: an experimental validation
- 8 December 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 105 (2) , 761-773
Power transformer temperature–moisture dynamics modeling: an experimental validation
- Open Access
- 22 November 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (23) , 4128
Dielectric Strength of Nanofluid-Impregnated Transformer Solid Insulation
The interest in developing new fluids that can be used as dielectric liquids for transformers has driven the research on dielectric nanofluids in the last years. A number of authors have reported promising results on the electrical and thermal properties of dielectric nanofluids. Less attention has been paid to the interaction of these fluids with the cellulose materials that constitute the solid insulation of the transformers. In the present study, the dielectric strength of cellulose insulation is investigated, comparing its behavior when it is impregnated with transformer mineral oil and when it is impregnated with a dielectric nanofluid. The study includes the analysis of the AC breakdown voltage and the impulse breakdown voltage of the samples. Large improvements were observed on the AC breakdown voltages of the specimens impregnated with nanofluids, while the enhancements were lower in the case of the impulse tests. The reasons for the increase in AC breakdown voltage were investigated, considering the dielectric properties of the nanofluids used to impregnate the samples of cellulose. The analysis was completed with a finite element study that revealed the effect of the nanoparticles on the electric field distribution within the test cell, and its role in the observed enhancement.
- 22 November 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (23) , 4128
Open AccessDielectric Strength of Nanofluid-Impregnated Transformer Solid Insulation
The interest in developing new fluids that can be used as dielectric liquids for transformers has driven the research on dielectric nanofluids in the last years. A number of authors have reported promising results on the electrical and thermal properties of dielectric nanofluids. Less attention has been paid to the interaction of these fluids with the cellulose materials that constitute the solid insulation of the transformers. In the present study, the dielectric strength of cellulose insulation is investigated, comparing its behavior when it is impregnated with transformer mineral oil and when it is impregnated with a dielectric nanofluid. The study includes the analysis of the AC breakdown voltage and the impulse breakdown voltage of the samples. Large improvements were observed on the AC breakdown voltages of the specimens impregnated with nanofluids, while the enhancements were lower in the case of the impulse tests. The reasons for the increase in AC breakdown voltage were investigated, considering the dielectric properties of the nanofluids used to impregnate the samples of cellulose. The analysis was completed with a finite element study that revealed the effect of the nanoparticles on the electric field distribution within the test cell, and its role in the observed enhancement.