Khan Mohammad Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Khan Mohammad Khan has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Hemant Krishna
Laser Biomedical Applications Division Raja Ramanna Centre for Advanced Technology Indore India
6 shared publications- Shovan Kumar Majumder
Laser Biomedical Applications Division, Raja Ramanna Centre for Advanced Technology, Indore 452013, India; Homi Bhabha National Institute (HBNI), Training School Complex, Anushakti Nagar, Mumbai 400094, India
6 shared publications - Khageswar Sahu
Laser Biomedical Applications Division Raja Ramanna Centre for Advanced Technology Indore India
2 shared publications Nirmalya Ghosh
Indian Institute of Science Education and Research
2 shared publicationsAmrita Srivastava
Laser Biomedical Applications Section, Raja Ramanna Centre for Advanced Technology, Indore, India
1 shared publicationAnita Dalal
Laser Biomedical Applications Section, Raja Ramanna Centre for Advanced Technology, Indore, India
1 shared publication
Latest Publications
- Open Access
- 1 May 2026
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 57 (9) , 1565-1576
Transmission Raman Spectroscopy (TRS) for Accurate Authentication of API in Coated Hydroxychloroquine (HCQ) Tablets
Hydroxychloroquine (HCQ) is widely used as an antimalarial, anti‐inflammatory, and immunomodulatory drug. However, adulteration of the API in HCQ tablets not only adversely affects the efficacy of this common drug but also raises the risk to the recipient significantly, which many a times can lead to life threatening conditions. Hence, authentication of the API of HCQ tablets is an unmet need globally, requiring urgent attention. The current methods of API authentication in a coated tablet are chemical intensive, costly, and time‐consuming and are not specific to the molecules forming the API. Herein, we report, the development and use of a transmission Raman spectroscopy (TRS) system for a more accurate but nonintrusive way of authentication of HCQ tablets in presence of the coating which otherwise is not possible using the conventional chemical methods and the existing configurations of Raman spectroscopy. The outcome of the study conducted on five different commercial brands of HCQ is that while the backscattered Raman signals, because of the large interference arising out of the coating itself, deviated significantly (particularly at ~400, 518, and 642 cm −1 ) from the Raman spectrum of pure API, the interference was almost zero in case of the signals obtained using TRS, and a greater extent of spectral matching ( R 2 > 0.97) could be noted. The higher sensitivity of TRS towards the inner contents (i.e., API) of the tablets and insignificant susceptibility to the coating on the tablet surface reveals its true potential for an accurate authentication of the API.
- 1 May 2026
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 57 (9) , 1565-1576
Open AccessTransmission Raman Spectroscopy (TRS) for Accurate Authentication of API in Coated Hydroxychloroquine (HCQ) Tablets
Hydroxychloroquine (HCQ) is widely used as an antimalarial, anti‐inflammatory, and immunomodulatory drug. However, adulteration of the API in HCQ tablets not only adversely affects the efficacy of this common drug but also raises the risk to the recipient significantly, which many a times can lead to life threatening conditions. Hence, authentication of the API of HCQ tablets is an unmet need globally, requiring urgent attention. The current methods of API authentication in a coated tablet are chemical intensive, costly, and time‐consuming and are not specific to the molecules forming the API. Herein, we report, the development and use of a transmission Raman spectroscopy (TRS) system for a more accurate but nonintrusive way of authentication of HCQ tablets in presence of the coating which otherwise is not possible using the conventional chemical methods and the existing configurations of Raman spectroscopy. The outcome of the study conducted on five different commercial brands of HCQ is that while the backscattered Raman signals, because of the large interference arising out of the coating itself, deviated significantly (particularly at ~400, 518, and 642 cm −1 ) from the Raman spectrum of pure API, the interference was almost zero in case of the signals obtained using TRS, and a greater extent of spectral matching ( R 2 > 0.97) could be noted. The higher sensitivity of TRS towards the inner contents (i.e., API) of the tablets and insignificant susceptibility to the coating on the tablet surface reveals its true potential for an accurate authentication of the API.
- 17 January 2025
- Published by Wiley in Journal of Biophotonics
- Vol. 18 (3) , e202400374
An Artefact‐Minimized Raman Probe for Analyzing Biological Tissues
Availability of a suitable tool for carrying out non‐invasive measurement of Raman signatures in situ, from biological tissues having low Raman cross section is a clinically unmet need faced with manifold challenges. A Raman probe can prove to be an invaluable component of clinical Raman diagnostic systems. We present development of a Raman probe capable of measuring artefact free Raman spectra of biological tissues in situ. The developed probe uses a single lens for simultaneous illumination and collection of the Raman signal backscattered from the sample surface. This configuration ensures not only maximum overlapping of the illumination and collection volumes, ultimately leading to optimal throughput but also reduces the fiber‐induced artefacts. The results show a superior performance of the developed Raman probe in measuring the Raman signatures from biological samples having lower Raman cross‐sections, compared to that of the two commercially available Raman probes.
- 17 January 2025
- Published by Wiley in Journal of Biophotonics
- Vol. 18 (3) , e202400374
An Artefact‐Minimized Raman Probe for Analyzing Biological Tissues
Availability of a suitable tool for carrying out non‐invasive measurement of Raman signatures in situ, from biological tissues having low Raman cross section is a clinically unmet need faced with manifold challenges. A Raman probe can prove to be an invaluable component of clinical Raman diagnostic systems. We present development of a Raman probe capable of measuring artefact free Raman spectra of biological tissues in situ. The developed probe uses a single lens for simultaneous illumination and collection of the Raman signal backscattered from the sample surface. This configuration ensures not only maximum overlapping of the illumination and collection volumes, ultimately leading to optimal throughput but also reduces the fiber‐induced artefacts. The results show a superior performance of the developed Raman probe in measuring the Raman signatures from biological samples having lower Raman cross‐sections, compared to that of the two commercially available Raman probes.
- 19 June 2019
- Published by Wiley in Journal of Biophotonics
- Vol. 12 (11) , e201900140
Inverse spatially‐offset Raman spectroscopy using optical fibers: An axicon lens‐free approach
Inverse spatially offset Raman spectroscopy (I‐SORS) seeks to interrogate deep inside a Raman‐active, layered, diffusely scattering sample. It makes a collimated laser beam incident onto the sample surface in the form of concentric illumination rings (of varying radii) from whose center the back‐scattered Raman signal is collected for detection. Since formation of illumination rings of different sizes requires an axicon to be moved along the axis of the collimated laser beam and axicons below a certain minimum size (~1 inch) are not readily available, this classical configuration incorporating an axicon cannot be used for designing a compact I‐SORS probe of narrower diameter. We report a novel scheme of implementing I‐SORS which overcomes this limitation by implementing ring illumination and point collection using two multi‐mode optical fibers. An important advantage of the proposed scheme is that unlike the previously reported inverse SORS configurations, it does not require physical movement of any of the optical components for generating spatial offsets needed for probing sub‐surface depths. Another advantage is its fiber‐optic configuration which is ideally suited for designing a compact and pencil‐sized I‐SORS probe, often desired in many practical situations for carrying out depth‐sensitive Raman measurements in situ from a layered turbid sample.
- 19 June 2019
- Published by Wiley in Journal of Biophotonics
- Vol. 12 (11) , e201900140
Inverse spatially‐offset Raman spectroscopy using optical fibers: An axicon lens‐free approach
Inverse spatially offset Raman spectroscopy (I‐SORS) seeks to interrogate deep inside a Raman‐active, layered, diffusely scattering sample. It makes a collimated laser beam incident onto the sample surface in the form of concentric illumination rings (of varying radii) from whose center the back‐scattered Raman signal is collected for detection. Since formation of illumination rings of different sizes requires an axicon to be moved along the axis of the collimated laser beam and axicons below a certain minimum size (~1 inch) are not readily available, this classical configuration incorporating an axicon cannot be used for designing a compact I‐SORS probe of narrower diameter. We report a novel scheme of implementing I‐SORS which overcomes this limitation by implementing ring illumination and point collection using two multi‐mode optical fibers. An important advantage of the proposed scheme is that unlike the previously reported inverse SORS configurations, it does not require physical movement of any of the optical components for generating spatial offsets needed for probing sub‐surface depths. Another advantage is its fiber‐optic configuration which is ideally suited for designing a compact and pencil‐sized I‐SORS probe, often desired in many practical situations for carrying out depth‐sensitive Raman measurements in situ from a layered turbid sample.
- 1 November 2016
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 6 (4) , 265-270
Spatially-offset fluorescence spectroscopy (SOFS) using ring illumination and point collection for sub-surface measurements in layered tissue
- 1 November 2016
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 6 (4) , 265-270
Spatially-offset fluorescence spectroscopy (SOFS) using ring illumination and point collection for sub-surface measurements in layered tissue
- 19 August 2016
- Published by IOP Publishing in Journal of Optics
- Vol. 18 (9) , 095301
Off-confocal Raman spectroscopy (OCRS) for subsurface measurements in layered turbid samples
We report, for the first time, the development of a depth-sensitive Raman spectroscopy system for investigating subsurface depths in a layered turbid sample using the concept of varying Raman collection zones, while keeping the point of illumination fixed on the surface of the target sample. The system makes use of a conventional confocal Raman configuration and realizes the variation in Raman collection zones employing off-confocal detection. This is effected by moving the tip of the Raman detection fiber (acting as the pinhole aperture) from the focus of the Raman collection objective either by taking the point of detection away from the objective (along its axis) or bringing it closer to the objective (along the same axis), thereby essentially offering two ways of enabling subsurface interrogation at a given time. Another important attraction of the approach is that it can be used for analyzing layered turbid samples at depths beyond the reach of the conventional confocal Raman, though not at the cost of any further modifications in its instrumentation. Furthermore, the illumination point remains fixed on the sample surface and no adjustment is required in the sample arm, which indeed are significant advantages for depth-sensitive measurements in situ from layered turbid samples, particularly those having irregular surfaces (like biological tissues). The ability of the system to recover Raman spectra of the subsurface layer was demonstrated using a layered non-biological phantom and a biological tissue sample.
- 19 August 2016
- Published by IOP Publishing in Journal of Optics
- Vol. 18 (9) , 095301
Off-confocal Raman spectroscopy (OCRS) for subsurface measurements in layered turbid samples
We report, for the first time, the development of a depth-sensitive Raman spectroscopy system for investigating subsurface depths in a layered turbid sample using the concept of varying Raman collection zones, while keeping the point of illumination fixed on the surface of the target sample. The system makes use of a conventional confocal Raman configuration and realizes the variation in Raman collection zones employing off-confocal detection. This is effected by moving the tip of the Raman detection fiber (acting as the pinhole aperture) from the focus of the Raman collection objective either by taking the point of detection away from the objective (along its axis) or bringing it closer to the objective (along the same axis), thereby essentially offering two ways of enabling subsurface interrogation at a given time. Another important attraction of the approach is that it can be used for analyzing layered turbid samples at depths beyond the reach of the conventional confocal Raman, though not at the cost of any further modifications in its instrumentation. Furthermore, the illumination point remains fixed on the sample surface and no adjustment is required in the sample arm, which indeed are significant advantages for depth-sensitive measurements in situ from layered turbid samples, particularly those having irregular surfaces (like biological tissues). The ability of the system to recover Raman spectra of the subsurface layer was demonstrated using a layered non-biological phantom and a biological tissue sample.
- 7 August 2015
- Published by Wiley in Journal of Biophotonics
- Vol. 8 (11-12) , 889-896
Cone–shell Raman spectroscopy (CSRS) for depth‐sensitive measurements in layered tissue
We report the development of a depth‐sensitive Raman spectroscopy system using the configuration of cone–shell excitation and cone detection. The system uses a 785 nm diode laser and three identical axicons for Raman excitation of the target sample in the form of a hollow conic section. The Raman scattered light from the sample, passed through the same (but solid) conic section, is collected for detection. Apart from its ability of probing larger depths (˜ few mm), an important attraction of the system is that the probing depths can be varied by simply varying the separation between axicons in the excitation arm. Furthermore, no adjustment is required in the sample arm, which is a significant advantage for noncontact, depth‐sensitive measurement. Evaluation of the performance of the developed setup on nonbiological phantom and biological tissue sample demonstrated its ability to recover Raman spectra of layers located at depths of ˜2–3 mm beneath the surface. magnified image
- 7 August 2015
- Published by Wiley in Journal of Biophotonics
- Vol. 8 (11-12) , 889-896
Cone–shell Raman spectroscopy (CSRS) for depth‐sensitive measurements in layered tissue
We report the development of a depth‐sensitive Raman spectroscopy system using the configuration of cone–shell excitation and cone detection. The system uses a 785 nm diode laser and three identical axicons for Raman excitation of the target sample in the form of a hollow conic section. The Raman scattered light from the sample, passed through the same (but solid) conic section, is collected for detection. Apart from its ability of probing larger depths (˜ few mm), an important attraction of the system is that the probing depths can be varied by simply varying the separation between axicons in the excitation arm. Furthermore, no adjustment is required in the sample arm, which is a significant advantage for noncontact, depth‐sensitive measurement. Evaluation of the performance of the developed setup on nonbiological phantom and biological tissue sample demonstrated its ability to recover Raman spectra of layers located at depths of ˜2–3 mm beneath the surface. magnified image
- 3 May 2014
- Published by Springer Nature in Food Analytical Methods
- Vol. 8 (1) , 93-102
Detection of Urea Adulteration in Milk Using Near-Infrared Raman Spectroscopy
- 3 May 2014
- Published by Springer Nature in Food Analytical Methods
- Vol. 8 (1) , 93-102
Detection of Urea Adulteration in Milk Using Near-Infrared Raman Spectroscopy
- 29 January 2013
- Published by Wiley in Journal of Biophotonics
- Vol. 7 (1-2) , 77-85
Depth‐sensitive Raman spectroscopy combined with optical coherence tomography for layered tissue analysis
Complete characterization of a layered tissue requires probing both the biochemical and the morphological information from its different layers at various depths. We report the development of a combined Raman spectroscopy (RS) and optical coherence tomography (OCT) system that is capable of measuring depth‐sensitive Raman signal from the tissue layers imaged by the OCT. The sample arm of a real‐time time‐domain OCT system was modified to allow for co‐alignment of the OCT with the Raman probe beam. The depth sensitivity of Raman was obtained by incorporating confocal Raman configuration that minimized out‐of‐focus Raman scattered light. The system was first validated using a layered phantom prepared by depositing a thin layer of paraffin over acetaminophen. A good correlation was observed between the OCT images and the Raman signal. The system was also used to record OCT and Raman images of a resected mucosal tissue sample. While OCT image showed the presence of epithelial and stromal layers, Raman spectra measured from these layers confirmed the biochemical difference between the two.
- 29 January 2013
- Published by Wiley in Journal of Biophotonics
- Vol. 7 (1-2) , 77-85
Depth‐sensitive Raman spectroscopy combined with optical coherence tomography for layered tissue analysis
Complete characterization of a layered tissue requires probing both the biochemical and the morphological information from its different layers at various depths. We report the development of a combined Raman spectroscopy (RS) and optical coherence tomography (OCT) system that is capable of measuring depth‐sensitive Raman signal from the tissue layers imaged by the OCT. The sample arm of a real‐time time‐domain OCT system was modified to allow for co‐alignment of the OCT with the Raman probe beam. The depth sensitivity of Raman was obtained by incorporating confocal Raman configuration that minimized out‐of‐focus Raman scattered light. The system was first validated using a layered phantom prepared by depositing a thin layer of paraffin over acetaminophen. A good correlation was observed between the OCT images and the Raman signal. The system was also used to record OCT and Raman images of a resected mucosal tissue sample. While OCT image showed the presence of epithelial and stromal layers, Raman spectra measured from these layers confirmed the biochemical difference between the two.