SMShovan Kumar Majumder

Shovan Kumar Majumder

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shovan Kumar Majumder has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Hemant Krishna

    Laser Biomedical Applications Division, Raja Ramanna Centre for Advanced Technology, Indore 452013, India; Homi Bhabha National Institute (HBNI), Training School Complex, Anushakti Nagar, Mumbai 400094, India

    13 shared publications
  • Khan Mohammad Khan

    Laser Biomedical Applications Division Raja Ramanna Centre for Advanced Technology Indore India

    6 shared publications
  • Surjendu Bikash Dutta

    Discipline of Physics, Indian Institute of Technology Indore, Khandwa Road, Simrol, Indore 453552, India; Laser Biomedical Applications Division, Raja Ramanna Centre for Advanced Technology, Indore 452013, India

    4 shared publications
  • Khan Mohammad Khan

    Laser Biomedical Applications Division, Raja Ramanna Centre for Advanced Technology, Indore 452013, India; Homi Bhabha National Institute (HBNI), Training School Complex, Anushakti Nagar, Mumbai 400094, India

    3 shared publications
  • Pradeep Kumar Gupta

    Indian Institute of Technology Delhi

    3 shared publications
  • Sharad Gupta

    Discipline of Biosciences and Biomedical Engineering & Discipline of Metallurgy Engineering and Materials Science, Indian Institute of Technology Indore, Khandwa Road, Simrol, Indore 453552, India

    3 shared publications

Latest Publications

  • Open Access

    Reverse confocal polarized Raman spectroscopy (RCPRS) for tissue analysis

    by Khan Mohammad Khan, Amrita Srivastava, Surjendu Bikash Dutta, Nitin Kumar, Shovan Kumar Majumder

    Confocal Raman spectroscopy (CRS) being one of the most widely used depth-sensitive techniques for measuring layer wise Raman characteristics of layered biological tissues faces two practical problems. First, the overall probing depth is limited in a given optical design of the CRS system and second, the objective lens used for focusing touches to surface of the target sample during probing of deeper sub-surface layers. To facilitate deeper probing in a given CRS system and to avoid lens-sample touching issue, an alternate scheme of depth-sensitive Raman measurement is presented. The scheme, named reverse confocal polarized Raman spectroscopy (RCPRS), uses an experimental arrangement of plane polarized illumination and orthogonal polarized detection in which depth-sensitive measurements are performed by moving the focal plane of the illumination beam away from the tissue surface unlike to CRS which obtains depth-separation by traversing across different depths of the target tissue. The performance of the RCPRS is evaluated using a non-biological phantom and a biological tissue. It is found that the introduction of polarization reduces the interference of the signals originating from the layers surrounding the target layer and thereby improving the depth-selectivity.


  • Insight into Optogenetics for Diabetes Management

    by Nidhi Maharwal, Rashmi Shrivastava, Shovan Kumar Majumder

    Optogenetics is an interdisciplinary field wherein optical and genetic engineering methods are employed together to impart photounresponsive cells (usually of higher animals) the ability to respond to light through expression of light-sensitive proteins sourced generally from algae or bacteria. It enables precise spatiotemporal control of various cellular activities through light stimulation. Recently, emerging as a synthetic biology-based approach for diabetes management, optogenetics can provide user-control of hormonal secretion by photoactivation of a suitably modified cell. For around a decade, studies have been performed on the applicability of various light-sensitive proteins and their incorporation into pancreatic and nonpancreatic cells for photoinduced insulin secretion. Further, in vivo studies demonstrated amelioration of diabetes in mouse models through photoactivation of the implanted engineered cells. Here, we attempt to highlight the various optogenetic approaches explored in terms of influencing the insulin secretion pathway at different points in light of the natural insulin secretion pathway in pancreatic β cells. We also discuss how transgenic cells of both pancreatic as well as nonpancreatic origin are exploited for photoinduced secretion of insulin. Recent advances on integration of “smart” technologies for remote control of light irradiation and thereby insulin secretion from implanted engineered cells in preclinical models are also described. Additionally, the need for further comprehensive studies on irradiation parameters, red-shifted opsins, and host–cell interaction is stressed to realize the full potential of optogenetics as a clinically applicable modality providing user-controlled “on demand” hormonal secretion for better management of diabetes.


  • Open Access

    Effect of nano-size on magnetostriction of BiFeO3 and exceptional magnetoelectric coupling properties of BiFeO3_P(VDF-TrFE) polymer composite films for magnetic field sensor application

    by Sonali Pradhan, Pratik P. Deshmukh, Rahul C. Kambale, Tulshidas C. Darvade, Shovan Kumar Majumder, S. Satapathy

    The existence of magnetostriction in bulk BiFeO3 is still a matter of investigation and it is also an issue to investigate the magnetostriction effect in nano BiFeO3. Present work demonstrates the existence of magnetostrictive strain in superparamagnetic BiFeO3 nanoparticles at room temperature and the magnetoelectric coupling properties in composite form with P(VDFTrFE). Despite few reports on the magnetostriction effect in bulk BiFeO3 evidenced by the indirect method, the direct method (strain gauge) was employed in this work to examine the magnetostriction of superparamagnetic BiFeO3. In addition, a high magnetoelectric coupling coefficient was observed by the lock-in technique for optimized BiFeO3_P(VDF-TrFE) nanocomposite film. These nanocomposite films also exhibit room-temperature multiferroic properties. These results provide aspects of material with immense potential for practical applications in spintronics and magneto-electronics applications. We report a magnetoelectric sensor using superparamagnetic BiFeO3_P(VDF-TrFE) nanocomposite film for detection of ac magnetic field.

  • Drop-coating deposition Raman spectroscopy for quantitative detection of urinary creatinine: a feasibility study

    by Surjendu Bikash Dutta, Hemant Krishna, Khan Mohammad Khan, Rashmi Shrivastava, Khageswar Sahu, Sharad Gupta, Shovan K Majumder

    We present the results of an exploratory study carried out to evaluate the applicability of drop coating deposition Raman spectroscopy (DCDRS) for quantitative determination of creatinine present in urine. A comparison of the conventional Raman and the DCDRS spectra measured from aqueous solutions of physiological concentration of creatinine showed significantly higher intensity for DCDRS. Although as compared to surface enhanced Raman spectroscopy (SERS) this intensity was considerably lower, the reproducibility of DCDRS was found to be significantly better (⩾92%) than that of SERS (∼75%). A multivariate chemometric algorithm based on partial least square regression was developed to predict the concentrations of creatinine on the basis of the measured set of DCDRS spectra of the aqueous creatinine solutions as well as artificial urine samples and the reference (known) concentrations of creatinine used for preparing the solutions. The algorithm, applied via leave-one-spectrum-out cross-validation, could detect creatinine present in the artificial urine samples with an accuracy of over 94% in the physiological concentration range. Further, the lower limit of detection was also found to be sufficient for determining the presence of the urinary creatinine levels lower than the physiological reference range. Overall, the findings of the study demonstrate a promising potential of DCDRS for quantitative analysis of creatinine present in urine.


  • Fluorescence photo-bleaching of urine and its applicability in oral cancer diagnosis

    by Surjendu Bikash Dutta, Hemant Krishna, Sharad Gupta, Shovan K. Majumder


  • Inverse spatially‐offset Raman spectroscopy using optical fibers: An axicon lens‐free approach

    by Khan Mohd. Khan, Surjendu B. Dutta, Nitin Kumar, Anita Dalal, Amrita Srivastava, Hemant Krishna, Shovan K. Majumder

    Inverse spatially offset Raman spectroscopy (I‐SORS) seeks to interrogate deep inside a Raman‐active, layered, diffusely scattering sample. It makes a collimated laser beam incident onto the sample surface in the form of concentric illumination rings (of varying radii) from whose center the back‐scattered Raman signal is collected for detection. Since formation of illumination rings of different sizes requires an axicon to be moved along the axis of the collimated laser beam and axicons below a certain minimum size (~1 inch) are not readily available, this classical configuration incorporating an axicon cannot be used for designing a compact I‐SORS probe of narrower diameter. We report a novel scheme of implementing I‐SORS which overcomes this limitation by implementing ring illumination and point collection using two multi‐mode optical fibers. An important advantage of the proposed scheme is that unlike the previously reported inverse SORS configurations, it does not require physical movement of any of the optical components for generating spatial offsets needed for probing sub‐surface depths. Another advantage is its fiber‐optic configuration which is ideally suited for designing a compact and pencil‐sized I‐SORS probe, often desired in many practical situations for carrying out depth‐sensitive Raman measurements in situ from a layered turbid sample.


  • Nanotrap-Enhanced Raman Spectroscopy: An Efficient Technique for Trace Detection of Bioanalytes

    by Surjendu Bikash Dutta, Rashmi Shrivastava, Hemant Krishna, Khan Mohammad Khan, Sharad Gupta, Shovan Kumar Majumder

    Reliable diagnosis of disease using body fluids requires sensitive and accurate detection of disease-specific analytes present in the fluid. In recent years, there has been increasing interest in using surface-enhanced Raman spectroscopy (SERS) for this purpose. The demonstrable signal enhancement and sensitivity of SERS makes it ideally suited for detection of trace quantity of any analyte. However, lack of reproducibility along with large spatial variability in the measured Raman intensities due to differential (and often random) distribution of surface ‘hotspots’ limits its routine clinical use. We propose here a novel technique, nano-trap enhanced Raman spectroscopy (NTERS) for overcoming these long-standing limitations and challenges of SERS. In this technique, “hotspots” are formed by drying up a micro volume drop of the liquid, containing the mixture of nanoparticles and analytes in the focal volume of the Raman excitation laser, and the Raman signal is detected from these spots containing the analytes localized within the nanoparticle aggregates. The performance of the technique was evaluated in detecting trace quantities of two Raman active analytes, Rhodamine 6G (R6G) and urea. It was found that R6G and urea could be detected down to a concentration of 50 nM with signal to noise ratio (SNR) value of ~75 and 4 mM with SNR value of ~500, respectively. A comparison with SERS revealed that NTERS not only had significantly superior (around two orders of magnitude) signal enhancement but also had high reproducibility because of its intrinsic ability to form nanoparticle aggregates with high repetitiveness. Another advantage of NTERS is its simplicity and cost effectiveness as it does not require any specialized substrate.


  • Off-confocal Raman spectroscopy (OCRS) for subsurface measurements in layered turbid samples

    by Khan Mohammad Khan, Nirmalya Ghosh, Shovan Kumar Majumder

    We report, for the first time, the development of a depth-sensitive Raman spectroscopy system for investigating subsurface depths in a layered turbid sample using the concept of varying Raman collection zones, while keeping the point of illumination fixed on the surface of the target sample. The system makes use of a conventional confocal Raman configuration and realizes the variation in Raman collection zones employing off-confocal detection. This is effected by moving the tip of the Raman detection fiber (acting as the pinhole aperture) from the focus of the Raman collection objective either by taking the point of detection away from the objective (along its axis) or bringing it closer to the objective (along the same axis), thereby essentially offering two ways of enabling subsurface interrogation at a given time. Another important attraction of the approach is that it can be used for analyzing layered turbid samples at depths beyond the reach of the conventional confocal Raman, though not at the cost of any further modifications in its instrumentation. Furthermore, the illumination point remains fixed on the sample surface and no adjustment is required in the sample arm, which indeed are significant advantages for depth-sensitive measurements in situ from layered turbid samples, particularly those having irregular surfaces (like biological tissues). The ability of the system to recover Raman spectra of the subsurface layer was demonstrated using a layered non-biological phantom and a biological tissue sample.