Ashok Thakkar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ashok Thakkar has a total of 182 co-authors. Here are the top co-authors by number of shared publications:
Jayesh Prajapati
Apollo Hospitals, Ahmedabad, Gujarat 382428, India
3 shared publicationsShivani Kothari
Department of Clinical Trials, Sahajanand Medical Technologies Pvt. Ltd., Surat, Gujarat 395004, India
3 shared publicationsAnurag Polavarapu
Lalitha Super Specialty Hospital Pvt. Ltd., Heart and Brain Centre, Kothapet, Guntur, Andhra Pradesh 522001, India
2 shared publicationsArohi Sarang
2 shared publicationsAsif Raheem
Yashfeen Cardiac Hospital, Navsari, Gujarat 396445, India
2 shared publicationsAxel Linke
2 shared publications
Latest Publications
- Open Access
- 24 July 2026
- Published by Elsevier in Structural Heart
- Vol. 10 (9)
Impact of Early Nonfatal Complications After Transcatheter Aortic Valve Implantation on 1-Year Mortality and Quality of Life: Insights From the LANDMARK Trial
- 24 July 2026
- Published by Elsevier in Structural Heart
- Vol. 10 (9)
Open AccessImpact of Early Nonfatal Complications After Transcatheter Aortic Valve Implantation on 1-Year Mortality and Quality of Life: Insights From the LANDMARK Trial
- Open Access
- 28 August 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 27 (2) , 247-260
Comparative 30-day echocardiographic outcomes of Myval vs. Sapien and Evolut THVs: insights from LANDMARK trial
Aims: Several factors, including device design, annulus size, and sizing strategies, influence transcatheter heart valve (THV) haemodynamic outcomes in patients with aortic stenosis (AS). This sub-study evaluates early (30-day) echocardiographic outcomes of the Myval, Sapien, and Evolut THV series, focusing on haemodynamic performance and valve durability. Methods and results: The LANDMARK trial is a prospective, randomised, multicentre, open-label, non-inferiority trial comparing 384 patients implanted with Myval THV series to 384 receiving Sapien and Evolut THV series. Haemodynamic assessments followed Valve Academic Research Consortium-3 recommendations. At 30-day, haemodynamic device success rates were 85.9%, 77.8, and 85.4% for Myval, Sapien, and Evolut THV series, respectively (PMyval-Sapien = 0.03 and PMyval-Evolut = 0.98). Significant improvements in peak aortic flow velocity, pressure gradients, effective orifice area (EOA), Doppler velocity index (DVI), and cardiac indices were observed across all groups, except for unchanged left ventricular ejection fraction. Moderate prosthesis-patient mismatch (PPM) was less frequent with Myval THV series(11.3%) vs. Sapien THV series(21.8%), but higher than Evolut THV series (5.3%) (PMyval-Sapien = 0.0024, PMyval-Evolut = 0.0396), while severe PPM showed no significant differences (4.2% vs. 6.3% vs. 1.8%; PMyval-Sapien = 0.394, PMyval-Evolut = 0.2438). Rates of ≥ moderate paravalvular leak (PVL) were lower in Myval (3.5%), and Sapien (1.7%) compared with Evolut THV series (8.3%) (PMyval-Sapien = 0.3769, PMyval-Evolut = 0.0336). Myval THV series required minimal oversizing compared with Evolut THV series (P < 0.0001). Conclusion: The Myval THV series demonstrates short-term haemodynamic performance comparable to Evolut THV series and superior to Sapien THV series. Including intermediate sizes minimizes oversizing, underscoring its potential as an alternative for TAVI patients. Long-term follow-up is necessary to confirm these findings. Clinical trial registration: ClinicalTrials.gov: NCT04275726, EudraCT number 2020-000,137-40
- 28 August 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 27 (2) , 247-260
Open AccessComparative 30-day echocardiographic outcomes of Myval vs. Sapien and Evolut THVs: insights from LANDMARK trial
Aims: Several factors, including device design, annulus size, and sizing strategies, influence transcatheter heart valve (THV) haemodynamic outcomes in patients with aortic stenosis (AS). This sub-study evaluates early (30-day) echocardiographic outcomes of the Myval, Sapien, and Evolut THV series, focusing on haemodynamic performance and valve durability. Methods and results: The LANDMARK trial is a prospective, randomised, multicentre, open-label, non-inferiority trial comparing 384 patients implanted with Myval THV series to 384 receiving Sapien and Evolut THV series. Haemodynamic assessments followed Valve Academic Research Consortium-3 recommendations. At 30-day, haemodynamic device success rates were 85.9%, 77.8, and 85.4% for Myval, Sapien, and Evolut THV series, respectively (PMyval-Sapien = 0.03 and PMyval-Evolut = 0.98). Significant improvements in peak aortic flow velocity, pressure gradients, effective orifice area (EOA), Doppler velocity index (DVI), and cardiac indices were observed across all groups, except for unchanged left ventricular ejection fraction. Moderate prosthesis-patient mismatch (PPM) was less frequent with Myval THV series(11.3%) vs. Sapien THV series(21.8%), but higher than Evolut THV series (5.3%) (PMyval-Sapien = 0.0024, PMyval-Evolut = 0.0396), while severe PPM showed no significant differences (4.2% vs. 6.3% vs. 1.8%; PMyval-Sapien = 0.394, PMyval-Evolut = 0.2438). Rates of ≥ moderate paravalvular leak (PVL) were lower in Myval (3.5%), and Sapien (1.7%) compared with Evolut THV series (8.3%) (PMyval-Sapien = 0.3769, PMyval-Evolut = 0.0336). Myval THV series required minimal oversizing compared with Evolut THV series (P < 0.0001). Conclusion: The Myval THV series demonstrates short-term haemodynamic performance comparable to Evolut THV series and superior to Sapien THV series. Including intermediate sizes minimizes oversizing, underscoring its potential as an alternative for TAVI patients. Long-term follow-up is necessary to confirm these findings. Clinical trial registration: ClinicalTrials.gov: NCT04275726, EudraCT number 2020-000,137-40
- Open Access
- 30 October 2024
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 4 (4)
Comparative mid-term evaluation of unilateral and bilateral total knee arthroplasty utilizing metal-backed components: An assessment of functional and clinical outcomes
- 30 October 2024
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 4 (4)
Open AccessComparative mid-term evaluation of unilateral and bilateral total knee arthroplasty utilizing metal-backed components: An assessment of functional and clinical outcomes
- Open Access
- 13 December 2016
- Published by European Medical Group in European Medical Journal
- Vol. 1 (4) , 114-125
Revolution of Drug-Eluting Coronary Stents: An Analysis of Market Leaders
Percutaneous coronary intervention with drug-eluting stents (DES) is a well-established and widely-accepted treatment approach in patients with coronary artery disease. Although the underlying principle of DES remains constant for different stents available on the market, certain factors may offer variations with respect to deliverability (ease of placement), efficacy (preventing restenosis), and safety (thrombosis rates). These factors may include the type of drug (sirolimus, everolimus, biolimus, zotarolimus, novolimus, paclitaxel, docetaxel), type of stent platforms (stainless steel, platinum, cobalt-chromium, cobalt-nickel, platinum-chromium), type of polymers (permanent, biodegradable, polymer-free), thickness of stent struts (thick, thin, ultra-thin), type of coating (abluminal, conformal), and type of stent design (open-cell, closed-cell, combination of open-closed cell). In this context, we present a review on characteristic features of several of the most widely used coronary stents worldwide. Furthermore, the advancements of completely biodegradable stents are discussed. In addition, the future directions for the development of creating an ideal or perfect DES are debated.
- 13 December 2016
- Published by European Medical Group in European Medical Journal
- Vol. 1 (4) , 114-125
Open AccessRevolution of Drug-Eluting Coronary Stents: An Analysis of Market Leaders
Percutaneous coronary intervention with drug-eluting stents (DES) is a well-established and widely-accepted treatment approach in patients with coronary artery disease. Although the underlying principle of DES remains constant for different stents available on the market, certain factors may offer variations with respect to deliverability (ease of placement), efficacy (preventing restenosis), and safety (thrombosis rates). These factors may include the type of drug (sirolimus, everolimus, biolimus, zotarolimus, novolimus, paclitaxel, docetaxel), type of stent platforms (stainless steel, platinum, cobalt-chromium, cobalt-nickel, platinum-chromium), type of polymers (permanent, biodegradable, polymer-free), thickness of stent struts (thick, thin, ultra-thin), type of coating (abluminal, conformal), and type of stent design (open-cell, closed-cell, combination of open-closed cell). In this context, we present a review on characteristic features of several of the most widely used coronary stents worldwide. Furthermore, the advancements of completely biodegradable stents are discussed. In addition, the future directions for the development of creating an ideal or perfect DES are debated.
- Open Access
- 22 October 2015
- Published by Hindawi Limited in Scientifica
- Vol. 2015, 1-6
Clinical Outcomes from Unselected “Real-World” Patients with Long Coronary Lesion Receiving 40 mm Biodegradable Polymer Coated Sirolimus-Eluting Stent
Background. Long lesions being implanted with drug-eluting stents (DES) are associated with relatively high restenosis rates and higher incidences of adverse events. Objectives. We aimed to examine the safety and efficacy of the long (40mm) biodegradable polymer coated Indolimus sirolimus-eluting stent (SES) in real-world patients with long coronary lesions. Methods. This study was observational, nonrandomized, retrospective, and carried out in real-world patients. A total of 258 patients were enrolled for the treatment of long coronary lesions, with 40mm Indolimus. The primary endpoints in the study were incidence of major adverse cardiac events (MACE), a miscellany of cardiac death, myocardial infarction (MI), target lesion revascularization (TLR) or target vessel revascularization (TVR), and stent thrombosis (ST) up to 6-month follow-up. Results. The study population included higher proportion of males (74.4%) and average age was 53.2 ± 11.0 years. A total of 278 lesions were intervened successfully with 280 stents. The observed MACE at 6-month follow-up was 2.0%, which included 0.8% cardiac death and 1.2% MI. There were no TLR or TVR and ST observed during 6-month follow-up. Conclusions. The long (40mm) Indolimus stent demonstrated low MACE rate and was proven to be safe and effective treatment for long lesions in real-world patients. Background. Long lesions being implanted with drug-eluting stents (DES) are associated with relatively high restenosis rates and higher incidences of adverse events. Objectives. We aimed to examine the safety and efficacy of the long (40mm) biodegradable polymer coated Indolimus sirolimus-eluting stent (SES) in real-world patients with long coronary lesions. Methods. This study was observational, nonrandomized, retrospective, and carried out in real-world patients. A total of 258 patients were enrolled for the treatment of long coronary lesions, with 40mm Indolimus. The primary endpoints in the study were incidence of major adverse cardiac events (MACE), a miscellany of cardiac death, myocardial infarction (MI), target lesion revascularization (TLR) or target vessel revascularization (TVR), and stent thrombosis (ST) up to 6-month follow-up. Results. The study population included higher proportion of males (74.4%) and average age was 53.2 ± 11.0 years. A total of 278 lesions were intervened successfully with 280 stents. The observed MACE at 6-month follow-up was 2.0%, which included 0.8% cardiac death and 1.2% MI. There were no TLR or TVR and ST observed during 6-month follow-up. Conclusions. The long (40mm) Indolimus stent demonstrated low MACE rate and was proven to be safe and effective treatment for long lesions in real-world patients.
- 22 October 2015
- Published by Hindawi Limited in Scientifica
- Vol. 2015, 1-6
Open AccessClinical Outcomes from Unselected “Real-World” Patients with Long Coronary Lesion Receiving 40 mm Biodegradable Polymer Coated Sirolimus-Eluting Stent
Background. Long lesions being implanted with drug-eluting stents (DES) are associated with relatively high restenosis rates and higher incidences of adverse events. Objectives. We aimed to examine the safety and efficacy of the long (40mm) biodegradable polymer coated Indolimus sirolimus-eluting stent (SES) in real-world patients with long coronary lesions. Methods. This study was observational, nonrandomized, retrospective, and carried out in real-world patients. A total of 258 patients were enrolled for the treatment of long coronary lesions, with 40mm Indolimus. The primary endpoints in the study were incidence of major adverse cardiac events (MACE), a miscellany of cardiac death, myocardial infarction (MI), target lesion revascularization (TLR) or target vessel revascularization (TVR), and stent thrombosis (ST) up to 6-month follow-up. Results. The study population included higher proportion of males (74.4%) and average age was 53.2 ± 11.0 years. A total of 278 lesions were intervened successfully with 280 stents. The observed MACE at 6-month follow-up was 2.0%, which included 0.8% cardiac death and 1.2% MI. There were no TLR or TVR and ST observed during 6-month follow-up. Conclusions. The long (40mm) Indolimus stent demonstrated low MACE rate and was proven to be safe and effective treatment for long lesions in real-world patients. Background. Long lesions being implanted with drug-eluting stents (DES) are associated with relatively high restenosis rates and higher incidences of adverse events. Objectives. We aimed to examine the safety and efficacy of the long (40mm) biodegradable polymer coated Indolimus sirolimus-eluting stent (SES) in real-world patients with long coronary lesions. Methods. This study was observational, nonrandomized, retrospective, and carried out in real-world patients. A total of 258 patients were enrolled for the treatment of long coronary lesions, with 40mm Indolimus. The primary endpoints in the study were incidence of major adverse cardiac events (MACE), a miscellany of cardiac death, myocardial infarction (MI), target lesion revascularization (TLR) or target vessel revascularization (TVR), and stent thrombosis (ST) up to 6-month follow-up. Results. The study population included higher proportion of males (74.4%) and average age was 53.2 ± 11.0 years. A total of 278 lesions were intervened successfully with 280 stents. The observed MACE at 6-month follow-up was 2.0%, which included 0.8% cardiac death and 1.2% MI. There were no TLR or TVR and ST observed during 6-month follow-up. Conclusions. The long (40mm) Indolimus stent demonstrated low MACE rate and was proven to be safe and effective treatment for long lesions in real-world patients.
- Open Access
- 2 September 2015
- Published by Hindawi Limited in International Journal of Vascular Medicine
- Vol. 2015, 1-5
Favorable Outcomes after Implantation of Biodegradable Polymer Coated Sirolimus-Eluting Stents in Diabetic Population: Results from INDOLIMUS-G Diabetic Registry
Objective. The main aim is to evaluate safety, efficacy, and clinical performance of the Indolimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) sirolimus-eluting stent in high-risk diabetic population with complex lesions. Methods. It was a multicentre, retrospective, non-randomized, single-arm study, which enrolled 372 diabetic patients treated with Indolimus. The primary endpoint of the study was major adverse cardiac events (MACE), which is a composite of cardiac death, target lesion revascularization (TLR), target vessel revascularization (TVR), myocardial infarction (MI), and stent thrombosis (ST). The clinical follow-ups were scheduled at 30 days, 6 months, and 9 months. Results. The mean age of the enrolled patients was 53.4 ± 10.2 years. A total of 437 lesions were intervened successfully with 483 stents (1.1 ± 0.3 per lesion). There were 256 (68.8%) male patients. Hypertension and totally occluded lesions were found in 202 (54.3%) and 45 (10.3%) patients, respectively. The incidence of MACE at 30 days, 6 months and 9 months was 0 (0%), 6 (1.6%), and 8 (2.2%), respectively. The event-free survival at 9-month follow-up by Kaplan Meier method was found to be 97.8%. Conclusion. The use of biodegradable polymer coated sirolimus-eluting stent is associated with favorable outcomes. The results demonstrated in our study depict its safety and efficacy in diabetic population. Objective. The main aim is to evaluate safety, efficacy, and clinical performance of the Indolimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) sirolimus-eluting stent in high-risk diabetic population with complex lesions. Methods. It was a multicentre, retrospective, non-randomized, single-arm study, which enrolled 372 diabetic patients treated with Indolimus. The primary endpoint of the study was major adverse cardiac events (MACE), which is a composite of cardiac death, target lesion revascularization (TLR), target vessel revascularization (TVR), myocardial infarction (MI), and stent thrombosis (ST). The clinical follow-ups were scheduled at 30 days, 6 months, and 9 months. Results. The mean age of the enrolled patients was 53.4 ± 10.2 years. A total of 437 lesions were intervened successfully with 483 stents (1.1 ± 0.3 per lesion). There were 256 (68.8%) male patients. Hypertension and totally occluded lesions were found in 202 (54.3%) and 45 (10.3%) patients, respectively. The incidence of MACE at 30 days, 6 months and 9 months was 0 (0%), 6 (1.6%), and 8 (2.2%), respectively. The event-free survival at 9-month follow-up by Kaplan Meier method was found to be 97.8%. Conclusion. The use of biodegradable polymer coated sirolimus-eluting stent is associated with favorable outcomes. The results demonstrated in our study depict its safety and efficacy in diabetic population.
- 2 September 2015
- Published by Hindawi Limited in International Journal of Vascular Medicine
- Vol. 2015, 1-5
Open AccessFavorable Outcomes after Implantation of Biodegradable Polymer Coated Sirolimus-Eluting Stents in Diabetic Population: Results from INDOLIMUS-G Diabetic Registry
Objective. The main aim is to evaluate safety, efficacy, and clinical performance of the Indolimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) sirolimus-eluting stent in high-risk diabetic population with complex lesions. Methods. It was a multicentre, retrospective, non-randomized, single-arm study, which enrolled 372 diabetic patients treated with Indolimus. The primary endpoint of the study was major adverse cardiac events (MACE), which is a composite of cardiac death, target lesion revascularization (TLR), target vessel revascularization (TVR), myocardial infarction (MI), and stent thrombosis (ST). The clinical follow-ups were scheduled at 30 days, 6 months, and 9 months. Results. The mean age of the enrolled patients was 53.4 ± 10.2 years. A total of 437 lesions were intervened successfully with 483 stents (1.1 ± 0.3 per lesion). There were 256 (68.8%) male patients. Hypertension and totally occluded lesions were found in 202 (54.3%) and 45 (10.3%) patients, respectively. The incidence of MACE at 30 days, 6 months and 9 months was 0 (0%), 6 (1.6%), and 8 (2.2%), respectively. The event-free survival at 9-month follow-up by Kaplan Meier method was found to be 97.8%. Conclusion. The use of biodegradable polymer coated sirolimus-eluting stent is associated with favorable outcomes. The results demonstrated in our study depict its safety and efficacy in diabetic population. Objective. The main aim is to evaluate safety, efficacy, and clinical performance of the Indolimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) sirolimus-eluting stent in high-risk diabetic population with complex lesions. Methods. It was a multicentre, retrospective, non-randomized, single-arm study, which enrolled 372 diabetic patients treated with Indolimus. The primary endpoint of the study was major adverse cardiac events (MACE), which is a composite of cardiac death, target lesion revascularization (TLR), target vessel revascularization (TVR), myocardial infarction (MI), and stent thrombosis (ST). The clinical follow-ups were scheduled at 30 days, 6 months, and 9 months. Results. The mean age of the enrolled patients was 53.4 ± 10.2 years. A total of 437 lesions were intervened successfully with 483 stents (1.1 ± 0.3 per lesion). There were 256 (68.8%) male patients. Hypertension and totally occluded lesions were found in 202 (54.3%) and 45 (10.3%) patients, respectively. The incidence of MACE at 30 days, 6 months and 9 months was 0 (0%), 6 (1.6%), and 8 (2.2%), respectively. The event-free survival at 9-month follow-up by Kaplan Meier method was found to be 97.8%. Conclusion. The use of biodegradable polymer coated sirolimus-eluting stent is associated with favorable outcomes. The results demonstrated in our study depict its safety and efficacy in diabetic population.
- 24 April 2015
- Vol. 64 (1) , 9-14
Clinical performance of biodegradable polymer-coated sirolimus-eluting stents in unselected real-world population with coronary artery disease: results from the multicenter CORE Registry.
The main aim of the CORE Registry was to evaluate clinical performance of the Supralimus-Core® biodegradable polymer-coated sirolimus-eluting cobalt-chromium stent (Sahajanand Medical technologies Pvt. Ltd., Surat, India) in unselected real-world patients. This was a multicenter, retrospective, non-randomized, single-arm study. A total of 376 consecutive patients treated with the Supralimus-Core® between April 2010 and June 2014 were enrolled. The primary-end point of the registry was major adverse cardiac events (MACE), which is a composite of cardiac death, target lesion revascularization (TLR), target vessel revascularization (TVR), myocardial infarction (MI) and stent thrombosis (ST). Clinical follow-up were scheduled at 30-day and 6-month. The mean age of enrolled patients was 54.6±10.3 years. A total of 444 lesions were treated successfully with 457 stents (1.0±0.2 per lesion). The average stent length and diameter was 24.0±8.0 mm and 3.0±0.33 mm, respectively. Out of total patients, 300 (79.8%) were male. Diabetes, hypertension and chronic totally occluded lesions were found in 95 (25.3%), 102 (27.1%) and 125 (28.2%) patients, respectively, reflecting high-risk patients involvement. The incidence of MACE at 30-day and 6-month was found to be in 4 (1.1 %) and 4 (1.1%) patients, respectively. The TLR and ST was found in 1 (0.3 %) and 1 (0.3 %) patient respectively at 6-month follow-up. The lower incidence of MACE, TLR and ST clearly delineates safety and efficacy of Supralimus-Core sirolimus-eluting stent in "real-world" patients with complex coronary lesions.
- 24 April 2015
- Vol. 64 (1) , 9-14
Clinical performance of biodegradable polymer-coated sirolimus-eluting stents in unselected real-world population with coronary artery disease: results from the multicenter CORE Registry.
The main aim of the CORE Registry was to evaluate clinical performance of the Supralimus-Core® biodegradable polymer-coated sirolimus-eluting cobalt-chromium stent (Sahajanand Medical technologies Pvt. Ltd., Surat, India) in unselected real-world patients. This was a multicenter, retrospective, non-randomized, single-arm study. A total of 376 consecutive patients treated with the Supralimus-Core® between April 2010 and June 2014 were enrolled. The primary-end point of the registry was major adverse cardiac events (MACE), which is a composite of cardiac death, target lesion revascularization (TLR), target vessel revascularization (TVR), myocardial infarction (MI) and stent thrombosis (ST). Clinical follow-up were scheduled at 30-day and 6-month. The mean age of enrolled patients was 54.6±10.3 years. A total of 444 lesions were treated successfully with 457 stents (1.0±0.2 per lesion). The average stent length and diameter was 24.0±8.0 mm and 3.0±0.33 mm, respectively. Out of total patients, 300 (79.8%) were male. Diabetes, hypertension and chronic totally occluded lesions were found in 95 (25.3%), 102 (27.1%) and 125 (28.2%) patients, respectively, reflecting high-risk patients involvement. The incidence of MACE at 30-day and 6-month was found to be in 4 (1.1 %) and 4 (1.1%) patients, respectively. The TLR and ST was found in 1 (0.3 %) and 1 (0.3 %) patient respectively at 6-month follow-up. The lower incidence of MACE, TLR and ST clearly delineates safety and efficacy of Supralimus-Core sirolimus-eluting stent in "real-world" patients with complex coronary lesions.
- Open Access
- 1 April 2015
- Vol. 5 (2) , 145-149-149
Non-identical yet similar: presentation of coronary artery disease in dizygotic twins
Non-identical yet similar: presentation of coronary artery disease in dizygotic twins
- 1 April 2015
- Vol. 5 (2) , 145-149-149
Open AccessNon-identical yet similar: presentation of coronary artery disease in dizygotic twins
Non-identical yet similar: presentation of coronary artery disease in dizygotic twins
- 12 March 2015
- Published by BMJ in BMJ Case Reports
- Vol. 2015
Accessory pancreatic lobe with gastric duplication cyst: diagnostic challenges of a rare congenital anomaly
Reports of combined congenital abnormalities of gastric duplication cysts and accessory pancreatic lobes are rarely reported. Patients with such anomalies may require appropriate surgical intervention tailored to the individual patient for complete cure. A multimodality diagnostic approach using ultrasonography, CT and MRI is useful for appreciation of the relevant anatomy of the congenital abnormality and for proper surgical planning. We present a case of a gastric duplication cyst with accessory pancreatic lobe and ectopic pancreatic rest in a 5-year-old child presenting with symptoms of recurrent pancreatitis.
- 12 March 2015
- Published by BMJ in BMJ Case Reports
- Vol. 2015
Accessory pancreatic lobe with gastric duplication cyst: diagnostic challenges of a rare congenital anomaly
Reports of combined congenital abnormalities of gastric duplication cysts and accessory pancreatic lobes are rarely reported. Patients with such anomalies may require appropriate surgical intervention tailored to the individual patient for complete cure. A multimodality diagnostic approach using ultrasonography, CT and MRI is useful for appreciation of the relevant anatomy of the congenital abnormality and for proper surgical planning. We present a case of a gastric duplication cyst with accessory pancreatic lobe and ectopic pancreatic rest in a 5-year-old child presenting with symptoms of recurrent pancreatitis.