William J. Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
William J. Smith has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
David J. Timoney
University College Dublin
7 shared publications- Chunshui Lin
School of Natural Sciences, Physics, Ryan Institute’s Centre for Climate & Air Pollution Studies, University of Galway, Galway, H91 CF50, Ireland
3 shared publications - Darius Ceburnis
Centre for Climate and Air Pollution Studies, Ryan Institute, School of Natural Sciences, University of Galway, Galway, Ireland
3 shared publications - Jurgita Ovadnevaite
Ollscoil na Gaillimhe – University of Galway (Galway, Ireland)
3 shared publications Rory F. D. Monaghan
3 shared publicationsAlan N. Drew
School of Electrical, Electronic and Mechanical Engineering, University College Dublin, Belfield, Dublin 4, Ireland
2 shared publications
Latest Publications
- 2 March 2026
- Published by Springer Nature in Nature Geoscience
- Vol. 19 (4) , 447-454
Low-smoke fuels for residential heating linked to an increase in ultrafine particle emissions
- 2 March 2026
- Published by Springer Nature in Nature Geoscience
- Vol. 19 (4) , 447-454
Low-smoke fuels for residential heating linked to an increase in ultrafine particle emissions
- Open Access
Enhancing efficiency and reducing emissions in SOFC/RCCI hybrid systems: A novel integration approach
- Open Access
- 25 July 2023
- Published by Springer Nature in npj Climate and Atmospheric Science
- Vol. 6 (1) , 1-8
Air quality—climate forcing double whammy from domestic firelighters
Renewable biomass plays a crucial role in transitioning toward climate-friendly heating sources; however, not without its collateral damage in terms of the disproportionately high effects on local air quality. The associated proliferation of residential heating appliances around the world, including developed regions like Europe, where an estimated 70 million are housed, does not appear to be abating. Here, we identify super self-concentrating ambient pollution events whereby solid-fuel residential heating haze is infused with a hitherto unaccounted for firelighter smoke that contributes additional adsorbing black carbon. This black carbon-organic aerosol combination results in a strong positive radiative forcing (up to 149 W m−2) and alters the boundary layer thermodynamics sufficiently so as to further suppress pollutant dilution and dispersion leading to extraordinary high submicron particulate matter (PM1: 166 µg m−3). Unfortunately, there is no silver lining in this cloud until the promotion of solid biomass fires with firelighters for ignition is replaced by a co-benefit policy.
- 25 July 2023
- Published by Springer Nature in npj Climate and Atmospheric Science
- Vol. 6 (1) , 1-8
Open AccessAir quality—climate forcing double whammy from domestic firelighters
Renewable biomass plays a crucial role in transitioning toward climate-friendly heating sources; however, not without its collateral damage in terms of the disproportionately high effects on local air quality. The associated proliferation of residential heating appliances around the world, including developed regions like Europe, where an estimated 70 million are housed, does not appear to be abating. Here, we identify super self-concentrating ambient pollution events whereby solid-fuel residential heating haze is infused with a hitherto unaccounted for firelighter smoke that contributes additional adsorbing black carbon. This black carbon-organic aerosol combination results in a strong positive radiative forcing (up to 149 W m−2) and alters the boundary layer thermodynamics sufficiently so as to further suppress pollutant dilution and dispersion leading to extraordinary high submicron particulate matter (PM1: 166 µg m−3). Unfortunately, there is no silver lining in this cloud until the promotion of solid biomass fires with firelighters for ignition is replaced by a co-benefit policy.
- Open Access
- 26 February 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (6) , 4966-4978
Study of Emissions from Domestic Solid-Fuel Stove Combustion in Ireland
- 26 February 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (6) , 4966-4978
Open AccessStudy of Emissions from Domestic Solid-Fuel Stove Combustion in Ireland
- 1 December 2014
- Published by Elsevier in Applied Thermal Engineering
- Vol. 73 (1) , 681-690
Can CFD accurately predict the heat-transfer and pressure-drop performance of finned-tube bundles?
- 1 December 2014
- Published by Elsevier in Applied Thermal Engineering
- Vol. 73 (1) , 681-690
Can CFD accurately predict the heat-transfer and pressure-drop performance of finned-tube bundles?
- 1 July 2013
- Published by Elsevier in Energy Policy
- Vol. 58, 163-176
Projecting EU demand for natural gas to 2030: A meta-analysis
- 1 July 2013
- Published by Elsevier in Energy Policy
- Vol. 58, 163-176
Projecting EU demand for natural gas to 2030: A meta-analysis
- 8 April 2013
- Published by SAE International in SAE International Journal of Engines
- Vol. 06 (2) , 1035-1045
The Effect of a Three-Way Catalytic Converter on Particulate Matter from a Gasoline Direct-Injection Engine During Cold-Start
This work investigates the effect of a three-way catalytic converter and sampling dilution ratio on nano-scale exhaust particulate matter emissions from a gasoline direct-injection engine during cold-start and warm-up transients. Experimental results are presented from a four cylinder in-line, four stroke, wall-guided direct-injection, turbo-charged and inter-cooled 1.6 litre gasoline engine. A fast-response particulate spectrometer for exhaust nano-particle measurement up to 1000 nm was utilised. It was observed that the three-way catalytic converter had a significant effect on particle number density, reducing the total particle number by up to 65 % over the duration of the cold-start test. The greatest change in particle number density occurred for particles less than 23 nm diameter, with reductions of up to 95 % being observed, whilst the number density for particles above 50 nm diameter exhibited a significant increase. The exhaust temperature plays a significant role on the influence of the catalytic converter on the nano-scale particulate matter. It is evident that the dilution ratio of the exhaust sample has a distinct effect on the particulate matter number and size distribution, influencing the engine-out PM more significantly than the tailpipe-out PM during cold-start engine operation. The catalytic converter also has a considerable effect on the estimated total particle mass.
- 8 April 2013
- Published by SAE International in SAE International Journal of Engines
- Vol. 06 (2) , 1035-1045
The Effect of a Three-Way Catalytic Converter on Particulate Matter from a Gasoline Direct-Injection Engine During Cold-Start
This work investigates the effect of a three-way catalytic converter and sampling dilution ratio on nano-scale exhaust particulate matter emissions from a gasoline direct-injection engine during cold-start and warm-up transients. Experimental results are presented from a four cylinder in-line, four stroke, wall-guided direct-injection, turbo-charged and inter-cooled 1.6 litre gasoline engine. A fast-response particulate spectrometer for exhaust nano-particle measurement up to 1000 nm was utilised. It was observed that the three-way catalytic converter had a significant effect on particle number density, reducing the total particle number by up to 65 % over the duration of the cold-start test. The greatest change in particle number density occurred for particles less than 23 nm diameter, with reductions of up to 95 % being observed, whilst the number density for particles above 50 nm diameter exhibited a significant increase. The exhaust temperature plays a significant role on the influence of the catalytic converter on the nano-scale particulate matter. It is evident that the dilution ratio of the exhaust sample has a distinct effect on the particulate matter number and size distribution, influencing the engine-out PM more significantly than the tailpipe-out PM during cold-start engine operation. The catalytic converter also has a considerable effect on the estimated total particle mass.
- 10 September 2012
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
The Effect of Engine Operating Conditions on Engine-out Particulate Matter from a Gasoline Direct-injection Engine during Cold-start.
This work investigates the effect of engine operating conditions and exhaust sampling conditions (i.e. dilution ratio) on engine-out, nano-scale, particulate matter emissions from a gasoline direct-injection engine during cold-start and warm-up transients. The engine used for this research was an in-line four cylinder, four stroke, wall-guided direct-injection, turbo-charged and inter-cooled 1.6 l gasoline engine. A fast-response particulate spectrometer for exhaust nano-particle measurement up to 1000 nm was utilized, along with a spark-plug mounted pressure transducer for combustion analysis. It was observed that the total particle count decreases during the cold-start transient, and has a distinct relationship with the engine body temperature. Tests have shown that the engine body temperature may be used as a control strategy for engine-out particulate emissions. This work has identified that up to 95 % of particles emitted during the cold-start transient are in the 5-23 nm size range. It is also evident that the dilution ratio of the exhaust sample has a significant effect on the particulate matter number and size distribution.
- 10 September 2012
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
The Effect of Engine Operating Conditions on Engine-out Particulate Matter from a Gasoline Direct-injection Engine during Cold-start.
This work investigates the effect of engine operating conditions and exhaust sampling conditions (i.e. dilution ratio) on engine-out, nano-scale, particulate matter emissions from a gasoline direct-injection engine during cold-start and warm-up transients. The engine used for this research was an in-line four cylinder, four stroke, wall-guided direct-injection, turbo-charged and inter-cooled 1.6 l gasoline engine. A fast-response particulate spectrometer for exhaust nano-particle measurement up to 1000 nm was utilized, along with a spark-plug mounted pressure transducer for combustion analysis. It was observed that the total particle count decreases during the cold-start transient, and has a distinct relationship with the engine body temperature. Tests have shown that the engine body temperature may be used as a control strategy for engine-out particulate emissions. This work has identified that up to 95 % of particles emitted during the cold-start transient are in the 5-23 nm size range. It is also evident that the dilution ratio of the exhaust sample has a significant effect on the particulate matter number and size distribution.
- 1 August 2012
- Published by Elsevier in Energy Conversion and Management
- Vol. 60, 226-232
Optimal concentration and temperatures of solar thermal power plants
- 1 August 2012
- Published by Elsevier in Energy Conversion and Management
- Vol. 60, 226-232
Optimal concentration and temperatures of solar thermal power plants
- 27 June 2011
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
- Vol. 225 (5) , 614-618
Effect of operating condition on the particulate matter emission factor for a domestic biomass boiler
The effect of operating condition on the particulate matter emission factor for a domestic biomass boiler has been examined, with a view to improving emission inventories compiled under the Convention on Long-Range Transboundary Air Pollution (CLRTAP). It was found that the emission factor depended strongly on the boiler load, and that there were significant differences between the value used in current emission inventories and actual values found in a combustion installation from a typical domestic dwelling.
- 27 June 2011
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
- Vol. 225 (5) , 614-618
Effect of operating condition on the particulate matter emission factor for a domestic biomass boiler
The effect of operating condition on the particulate matter emission factor for a domestic biomass boiler has been examined, with a view to improving emission inventories compiled under the Convention on Long-Range Transboundary Air Pollution (CLRTAP). It was found that the emission factor depended strongly on the boiler load, and that there were significant differences between the value used in current emission inventories and actual values found in a combustion installation from a typical domestic dwelling.