TRTimo Rousu

Timo Rousu

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Timo Rousu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Highly variable pH effects on the interaction of diclofenac and indomethacin with human UDP-glucuronosyltransferases

    by Hongbo Zhang, Anne Soikkeli, Ari Tolonen, Timo Rousu, Jouni Hirvonen, Moshe Finel


  • Comparison of Unit Resolution Srm And Tof-Ms At 12,000 Mass Resolution For Quantitative Bioanalysis of 11 Steroids From Human Plasma

    by Timo Rousu, Ari Tolonen

    The use of high-resolution MS systems for quantitative bioanalysis is a growing field, even though a clear majority of bioanalytical methods are still based on MS/MS with triple quadrupole (QqQ) instrumentation. The recent advances in TOF-MS technology have provided increased linear range and a high selectivity of detection by increased mass resolution and mass accuracy, making these instruments attractive for quantitative analysis due to lack of a need for compound-specific detection reaction optimization and their capability to collect data for a high number of compounds by sensitive wide mass range data acquisition. Here, 11 steroids spiked to human plasma were analyzed by LC-MS using both a QqQ MS system and a TOF instrument operating at 12,000 mass resolution. Sample preparation was performed by hybrid SPE technology. The LOD were 0.5-5 and 0.5-20 ng/ml in plasma for all analytes with QqQ and TOF-MS detection, respectively. Although the results show wider linear range and slightly better sensitivity for most of the compounds with QqQ in comparison to TOF, acceptable performance was obtained for most of the compounds within the range of LOD to 2000 ng/ml (in plasma), this was also the case with LC-TOF-MS analysis. The main problem in TOF-MS analysis at 12,000 mass resolution from plasma was selectivity rather than sensitivity or linear range.


  • Use of comprehensive screening methods to detect selective human CAR activators

    by Jenni Küblbeck, Tuomo Laitinen, Johanna Jyrkkärinne, Timo Rousu, Ari Tolonen, Tobias Abel, Tanja Kortelainen, Jouko Uusitalo, Timo Korjamo, Paavo Honkakoski, et al.


  • Characterization of cyanide‐trapped methylated metabonates formed during reactive drug metabolite screening in vitro

    by Timo Rousu, Ari Tolonen

    Reactive metabolites are estimated to be one of the main reasons behind unexpected drug‐induced toxicity, by binding covalently to cell proteins or DNA. Due to their high reactivity and short lifespan, reactive metabolites are analyzed after chemical trapping with nucleophilic agents such as glutathione or cyanide. Recently, unexplained and uncharacterized methylated reaction products were reported in a human liver microsome based reactive metabolite trapping assay utilizing potassium cyanide as a trapping agent. Here, a similar assay was utilized to produce mono‐ or dimethylated and further cyanide‐trapped reaction products from propranolol, amlodipine and ciprofloxacin, followed by ultra‐performance liquid chromatography/time‐of‐flight mass spectrometry (UPLC/TOF‐MS) and ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) experiments for their more detailed structural elucidation. Formation of all observed cyanide‐trapped products was clearly NADPH‐dependent and thus metabolism‐mediated. The suggested reaction pathways included N‐methylation leading to iminium formation in primary and/or secondary amines preceded by cytochrome P450 (CYP)‐mediated reactions. As the methylation reaction was suggested to be involved in formation of the actual reactive iminium ion, the observed cyanide‐trapped products were experimental artifacts rather than trapped reactive metabolites. The results stress that to avoid overestimating the formation of reactive metabolites in vitro , this methylation phenomenon should be taken into account when interpreting the results of cyanide‐utilizing reactive metabolite trapping assays. This in turn emphasizes the importance of identification of the observed cyano conjugates during such studies. Yet, metabolite identification has a high importance to avoid overestimation of in vitro metabolic clearance in the cases where this kind of metabonate formation has a high impact in the disappearance rate of the compound. Copyright © 2011 John Wiley & Sons, Ltd.


  • Effects of Cell Differentiation and Assay Conditions on the UDP-Glucuronosyltransferase Activity in Caco-2 Cells

    by Hongbo Zhang, Ari Tolonen, Timo Rousu, Jouni Hirvonen, Moshe Finel

    Cell differentiation increases UDP-glucuronosyltransferase (UGT) gene expression in Caco-2 cells. Glucuronidation of 13 UGT substrates, 1-naphthol, diclofenac, epitestosterone, estradiol, ethinylestradiol, indomethacin, oxazepam, R- and S-propranolol, propofol, testosterone, trifluoperazine, and zidovudine, were studied to derive a broad view on the effect of cell differentiation on the glucuronidation activities of different human UGTs. In parallel, the glucuronidation of these compounds in human liver microsomes (HLM) and human intestinal microsomes (HIM) was analyzed. Because many of the substrates are highly lipophilic, the effects of dimethyl sulfoxide (DMSO) concentrations in the reaction mixture on glucuronidation rates were tested, as well as the effect of alamethicin, a pore-forming peptide. Large differences were observed in the effects of DMSO and alamethicin between recombinant UGTs and Caco-2 cells and HLM and HIM, and, therefore, the activity assays were performed under multiple conditions. Regardless of the assay conditions, however, the results clearly indicated that although differentiation increases glucuronidation activity, the rates in Caco-2 cells are mostly very low, much lower than those in either HLM or HIM. One clear exception was observed: substrates of UGT1A6, such as 1-naphthol, were glucuronidated at very high rates in both undifferentiated and differentiated Caco-2 cells. It may thus be concluded that Caco-2 cells, even differentiated ones, do not provide a good model system to assess first-pass drug glucuronidation in the intestine.


  • Comparison of triple quadrupole, hybrid linear ion trap triple quadrupole, time‐of‐flight and LTQ‐Orbitrap mass spectrometers in drug discovery phase metabolite screening and identification in vitro – amitriptyline and verapamil as model compounds

    by Timo Rousu, Jukka Herttuainen, Ari Tolonen

    Liquid chromatography in combination with mass spectrometry (LC/MS) is a superior analytical technique for metabolite profiling and identification studies performed in drug discovery and development laboratories. In the early phase of drug discovery the analytical approach should be both time‐ and cost‐effective, thus providing as much data as possible with only one visit to the laboratory, without the need for further experiments. Recent developments in mass spectrometers have created a situation where many different mass spectrometers are available for the task, each with their specific strengths and drawbacks. We compared the metabolite screening properties of four main types of mass spectrometers used in analytical laboratories, considering both the ability to detect the metabolites and provide structural information, as well as the issues related to time consumption in laboratory and thereafter in data processing. Human liver microsomal incubations with amitriptyline and verapamil were used as test samples, and early‐phase ‘one lab visit only’ approaches were used with all instruments. In total, 28 amitriptyline and 69 verapamil metabolites were found and tentatively identified. Time‐of‐flight mass spectrometry (TOFMS) was the only approach detecting all of them, shown to be the most suitable instrument for elucidating as comprehensive metabolite profile as possible leading also to lowest overall time consumption together with the LTQ‐Orbitrap approach. The latter however suffered from lower detection sensitivity and false negatives, and due to slow data acquisition rate required slower chromatography. Approaches with triple quadrupole mass spectrometry (QqQ) and hybrid linear ion trap triple quadrupole mass spectrometry (Q‐Trap) provided the highest amount of fragment ion data for structural elucidation, but, in addition to being unable to produce very high‐important accurate mass data, they suffered from many false negatives, and especially with the QqQ, from very high overall time consumption. Copyright © 2010 John Wiley & Sons, Ltd.


  • Rapid detection and characterization of reactive drug metabolites in vitro using several isotope‐labeled trapping agents and ultra‐performance liquid chromatography/time‐of‐flight mass spectrometry

    by Timo Rousu, Olavi Pelkonen, Ari Tolonen

    Reactive metabolites are believed to be one of the main reasons for unexpected drug‐induced toxicity issues, by forming covalent adducts with cell proteins or DNA. Due to their high reactivity and short lifespan they are not directly detected by traditional analytical methods, but are most traditionally analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS) after chemical trapping with nucleophilic agents such as glutathione. Here, a simple but very efficient assay was built up for screening reactive drug metabolites, utilizing stable isotope labeled glutathione, potassium cyanide and semicarbazide as trapping agents and highly sensitive ultra‐performance liquid chromatography/time‐of‐flight mass spectrometry (UPLC/TOFMS) as an analytical tool. A group of twelve structurally different compounds was used as a test set, and a large number of trapped metabolites were detected for most of them, including many conjugates not reported previously. Glutathione‐trapped metabolites were detected for nine of the twelve test compounds, whereas cyanide‐trapped metabolites were found for eight and semicarbazide‐trapped for three test compounds. The high mass accuracy of TOFMS provided unambiguous identification of change in molecular formula by formation of a reactive metabolite. In addition, use of a mass defect filter was found to be a usable tool when mining the trapped conjugates from the acquired data. The approach was shown to provide superior detection sensitivity in comparison to traditional methods based on neutral loss or precursor ion scanning with a triple quadrupole mass spectrometer, and clearly more efficient detection and characterization of reactive drug metabolites with a simpler test setup. Copyright © 2009 John Wiley & Sons, Ltd.