Holger Maune
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Holger Maune has a total of 223 co-authors. Here are the top co-authors by number of shared publications:
- Rolf Jakoby
Institute of Microwave Engineering and Photonics, Technical University of Darmstadt, Darmstadt, Germany
25 shared publications Rolf Jakoby
22 shared publications- Ersin Polat
Institute of Microwave Engineering and Photonics, Technische Universitt Darmstadt, Darmstadt, Germany
15 shared publications - Henning Tesmer
Institute of Microwave Engineering and Photonics, Technische Universitt Darmstadt, Darmstadt, Germany
12 shared publications - Roland Reese
Deutsche Telekom Technik GmbH, Darmstadt, Germany
10 shared publications - Dongwei Wang
Institute of Microwave Engineering and Photonics, Technische Universitt Darmstadt, Darmstadt, Germany
9 shared publications
Latest Publications
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 27 (5) , 130-134
IMS Workshop Program
Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 27 (5) , 130-134
IMS Workshop Program
Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Radio Frequency Identification
- Vol. 10, 1
Guest Editorial Special Issue on the 12th Annual IEEE International Conference on Wireless for Space and Extreme Environments (WiSEE 2024)
THE IEEE International Conference on Wireless for Space and Extreme Environments (WiSEE) has established itself as a premier interdisciplinary forum for researchers, engineers, and practitioners addressing the unique challenges of wireless technologies operating in space, aerospace, and other harsh or remote environments. Since its inception in 2013, WiSEE has demonstrated steady growth and increasing technical breadth. After the disruptions caused by the COVID-19 pandemic, the 2024 edition of WiSEE clearly reflected the renewed momentum of the community and the continued relevance of research on wireless systems for extreme environments. WiSEE 2024 was co-located with the IEEE RFID Conference on RFID Technology and Applications (RFID-TA 2024), further strengthening the interaction between the RFID and wireless-for-extreme-environments research communities.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Radio Frequency Identification
- Vol. 10, 1
Guest Editorial Special Issue on the 12th Annual IEEE International Conference on Wireless for Space and Extreme Environments (WiSEE 2024)
THE IEEE International Conference on Wireless for Space and Extreme Environments (WiSEE) has established itself as a premier interdisciplinary forum for researchers, engineers, and practitioners addressing the unique challenges of wireless technologies operating in space, aerospace, and other harsh or remote environments. Since its inception in 2013, WiSEE has demonstrated steady growth and increasing technical breadth. After the disruptions caused by the COVID-19 pandemic, the 2024 edition of WiSEE clearly reflected the renewed momentum of the community and the continued relevance of research on wireless systems for extreme environments. WiSEE 2024 was co-located with the IEEE RFID Conference on RFID Technology and Applications (RFID-TA 2024), further strengthening the interaction between the RFID and wireless-for-extreme-environments research communities.
- 11 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 26 (8) , 114-118
IEEE Radio and Wireless Week 2025 [Conference Report]
Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.
- 11 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 26 (8) , 114-118
IEEE Radio and Wireless Week 2025 [Conference Report]
Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.
- Open Access
- 17 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Materials for Electron Devices
- Vol. 2, 80-85
Transferable Freestanding Varactor Based on a Membrane Stack for Microwave Application
This work demonstrates the fabrication and characterization of a freestanding oxide varactor membrane designed for integration onto silicon substrates. An epitaxial varactor heterostructure composed of a 1% Mn-doped Ba $_{0.5}$ Sr$_{0.5}$TiO $_{3}$ dielectric layer and a SrMoO3 conductive layer was grown using pulsed laser deposition on a water-soluble sacrificial layer Sr3Al2O6. After the lift-off process, the varactor heterostructure was successfully transferred onto a silicon substrate. Structural analysis confirms the high crystallinity and strain relaxation of the heterostructure after transfer. Electrical measurements reveal high tunability (n=1.7) at 120 V/$\mu$ m, a quality factor exceeding 100 at 1 MHz, and a low leakage current density well below 5 A/m2. This approach overcomes the challenges of direct oxide growth of epitaxial varactor heterostructures on silicon, such as lattice mismatch and chemical incompatibility. These results validate the potential of freestanding varactor membranes for agile microwave and RF applications, offering a scalable route for high-performance, multifunctional devices with low energy consumption in next-generation telecommunications and wireless networks.
- 17 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Materials for Electron Devices
- Vol. 2, 80-85
Open AccessTransferable Freestanding Varactor Based on a Membrane Stack for Microwave Application
This work demonstrates the fabrication and characterization of a freestanding oxide varactor membrane designed for integration onto silicon substrates. An epitaxial varactor heterostructure composed of a 1% Mn-doped Ba $_{0.5}$ Sr$_{0.5}$TiO $_{3}$ dielectric layer and a SrMoO3 conductive layer was grown using pulsed laser deposition on a water-soluble sacrificial layer Sr3Al2O6. After the lift-off process, the varactor heterostructure was successfully transferred onto a silicon substrate. Structural analysis confirms the high crystallinity and strain relaxation of the heterostructure after transfer. Electrical measurements reveal high tunability (n=1.7) at 120 V/$\mu$ m, a quality factor exceeding 100 at 1 MHz, and a low leakage current density well below 5 A/m2. This approach overcomes the challenges of direct oxide growth of epitaxial varactor heterostructures on silicon, such as lattice mismatch and chemical incompatibility. These results validate the potential of freestanding varactor membranes for agile microwave and RF applications, offering a scalable route for high-performance, multifunctional devices with low energy consumption in next-generation telecommunications and wireless networks.
- Open Access
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 9 (2) , 126-132
Impact of MRI Field Strengths on Metasurface Enhancement
Metasurfaces have proved valuable in magnetic resonance imaging (MRI) applications through modifying the field profiles of radiofrequency coils to enhance imaging. Using metasurfaces to enhance a conventional coil, such as the table-integrated spine coil, allows imaging with practically no cables inside the bore. This work investigated the fundamental relationship between an MRI system's field strength and the enhancement effect of a metasurface. We simulated and manufactured grid metasurfaces for field strengths of 0.55 Tesla (0.55 T), 1.5 T and 3 T and evaluated them experimentally. We found increased enhancements of the signal-to-noise ratio (SNR) with lower field strengths. At 0.55 T, the enhancement in the vicinity of the metasurface (10.9-fold) was measured 3.8 times higher than at 3 T. Moreover, the SNR decreased less with field strength next to the metasurface compared to the spine coil. Our results indicate the capability of metasurfaces in low field MRI systems and can stimulate further research. This could benefit future applications in MRI-guided interventions through simplified handling, as well as countries currently underserved with MRIs due to low manufacturing costs.
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 9 (2) , 126-132
Open AccessImpact of MRI Field Strengths on Metasurface Enhancement
Metasurfaces have proved valuable in magnetic resonance imaging (MRI) applications through modifying the field profiles of radiofrequency coils to enhance imaging. Using metasurfaces to enhance a conventional coil, such as the table-integrated spine coil, allows imaging with practically no cables inside the bore. This work investigated the fundamental relationship between an MRI system's field strength and the enhancement effect of a metasurface. We simulated and manufactured grid metasurfaces for field strengths of 0.55 Tesla (0.55 T), 1.5 T and 3 T and evaluated them experimentally. We found increased enhancements of the signal-to-noise ratio (SNR) with lower field strengths. At 0.55 T, the enhancement in the vicinity of the metasurface (10.9-fold) was measured 3.8 times higher than at 3 T. Moreover, the SNR decreased less with field strength next to the metasurface compared to the spine coil. Our results indicate the capability of metasurfaces in low field MRI systems and can stimulate further research. This could benefit future applications in MRI-guided interventions through simplified handling, as well as countries currently underserved with MRIs due to low manufacturing costs.
- Open Access
Reproducibility of Electromagnetic Field Simulations of Local Radiofrequency Transmit Elements Tailored for 7 T MRI
The literature reports on radiofrequency (RF) transmit (Tx) elements tailored for ultrahigh-field (UHF) magnetic resonance imaging (MRI) showed confounded reproducibility due to variations in simulation tools, modeling assumptions, and meshing techniques. This study proposes a standardized methodology to improve reproducibility and consistency across research sites (testers) and simulation tools (testing conditions). The methodology includes detailed simulation workflow and performance metrics for RF Tx elements. The impact of the used mesh setting is assessed. Following the methodology, a reproducibility study was conducted using CST Microwave Studio Suite, HFSS, and Sim4Life. The methodology and simulations were ultimately validated through 7 T MRI phantom experiments. The reproducibility study showed consistent performance with less than 6% standard deviation for B1+ fields and 12% for peak SAR averaged over 10 g tissue (pSAR10g). The SAR efficiency metric (|B1+|/√pSAR10g) was particularly robust (B1+| maps showed good qualitative agreement. This study demonstrates the feasibility of a standardized methodology for achieving reproducible RF Tx element electromagnetic field simulations. By following the FAIR principles including making the framework publicly available, we promote transparency and collaboration within the MRI community, supporting the advancement of technological innovation and improving patient safety in UHF-MRI.
Open AccessReproducibility of Electromagnetic Field Simulations of Local Radiofrequency Transmit Elements Tailored for 7 T MRI
The literature reports on radiofrequency (RF) transmit (Tx) elements tailored for ultrahigh-field (UHF) magnetic resonance imaging (MRI) showed confounded reproducibility due to variations in simulation tools, modeling assumptions, and meshing techniques. This study proposes a standardized methodology to improve reproducibility and consistency across research sites (testers) and simulation tools (testing conditions). The methodology includes detailed simulation workflow and performance metrics for RF Tx elements. The impact of the used mesh setting is assessed. Following the methodology, a reproducibility study was conducted using CST Microwave Studio Suite, HFSS, and Sim4Life. The methodology and simulations were ultimately validated through 7 T MRI phantom experiments. The reproducibility study showed consistent performance with less than 6% standard deviation for B1+ fields and 12% for peak SAR averaged over 10 g tissue (pSAR10g). The SAR efficiency metric (|B1+|/√pSAR10g) was particularly robust (B1+| maps showed good qualitative agreement. This study demonstrates the feasibility of a standardized methodology for achieving reproducible RF Tx element electromagnetic field simulations. By following the FAIR principles including making the framework publicly available, we promote transparency and collaboration within the MRI community, supporting the advancement of technological innovation and improving patient safety in UHF-MRI.
- 5 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 25 (12) , 21-23
Welcome to Radio & Wireless Week 2025 [IEEE Radio & Wireless Week 2025]
Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.
- 5 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 25 (12) , 21-23
Welcome to Radio & Wireless Week 2025 [IEEE Radio & Wireless Week 2025]
Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.
- Open Access
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 9 (2) , 198-205
Impact of Unit Cell Density on Grid and Stripe Metasurfaces for MRI Receive Enhancement
Metasurfaces enable magnetic resonance imaging (MRI) without cables inside the bore by locally improving the sensitivity of scanner-integrated receive coils. This study systematically evaluates a novel grid design to provide signal enhancement for patient imaging. The potential of the proposed metasurface grid design was analyzed regarding its unit cell density and compared with stripe type metasurfaces. The effects were examined in-depth by numerical simulation, workbench measurements, and MRI experiments at 3 Tesla. Differences in the signal-to-noise ratio (SNR) using either the integrated body or spine coils were evaluated, as well as the influence of the metasurface orientation. The grid design provided a favorable eigenmode usable for MR imaging, where it has shown significantly less dependence on orientation, compared to stripe metasurfaces. With the densest grid, more than 26% higher SNR than its most spaced design was achieved. Combining the metasurface for imaging with the spine coil proved to be superior to the body coil. Applying the metasurface for knee imaging, the SNR was locally enhanced by more than 10-fold compared to the scan with only the spine coil. The high-density grid metasurfaces provided benefits compared to the multitude of designs evaluated. This work provides a comprehensive foundation for future developments of metasurfaces for MRI, whose advantages may be exploited e.g. in the domain of interventional radiology.
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 9 (2) , 198-205
Open AccessImpact of Unit Cell Density on Grid and Stripe Metasurfaces for MRI Receive Enhancement
Metasurfaces enable magnetic resonance imaging (MRI) without cables inside the bore by locally improving the sensitivity of scanner-integrated receive coils. This study systematically evaluates a novel grid design to provide signal enhancement for patient imaging. The potential of the proposed metasurface grid design was analyzed regarding its unit cell density and compared with stripe type metasurfaces. The effects were examined in-depth by numerical simulation, workbench measurements, and MRI experiments at 3 Tesla. Differences in the signal-to-noise ratio (SNR) using either the integrated body or spine coils were evaluated, as well as the influence of the metasurface orientation. The grid design provided a favorable eigenmode usable for MR imaging, where it has shown significantly less dependence on orientation, compared to stripe metasurfaces. With the densest grid, more than 26% higher SNR than its most spaced design was achieved. Combining the metasurface for imaging with the spine coil proved to be superior to the body coil. Applying the metasurface for knee imaging, the SNR was locally enhanced by more than 10-fold compared to the scan with only the spine coil. The high-density grid metasurfaces provided benefits compared to the multitude of designs evaluated. This work provides a comprehensive foundation for future developments of metasurfaces for MRI, whose advantages may be exploited e.g. in the domain of interventional radiology.