DXDaniel Xie

Daniel Xie

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daniel Xie has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Design of an advanced plasma chamber for third generation ECRIS

    by J. Cruz-Duran, J. Y. Benitez, J. P. Garcia, M. Handemagnon, C. M. Lyneis, L. Phair, D. S. Todd, D. Z. Xie

    Current high performing electron cyclotron resonance ion sources (ECRISs), such as versatile ECR for nuclear science, are limited in the generation of higher beam intensities and higher charge states by the design of the plasma chamber and its cooling capacity. Because of the potential to damage a chamber by losses of energetic electrons from the plasma, an ECRIS must be tuned sub-optimally to prevent the creation of very energetic electrons. As such, the plasma chamber acts as a key limiting factor to the production capabilities of an ECRIS. The effects of parameters such as the location of the “hotspot” in relation to the water-cooling channels, the material of the walls, and the convective factor are analyzed to assess their impact on the thermal performance of the ECRIS plasma chamber.

  • Fabrication of a Nb-Ti Superconducting Closed-Loop Coil for the Next-Generation 45 GHz ECR Ion Source MARS-D

    by Lianrong Xu, Janilee Benitez, Jaime Cruz Duran, Paolo Ferracin, Mariusz Juchno, Larry Phair, Damon Todd, Li Wang, Daniel Xie, Ye Yang

    Electron Cyclotron Resonance Ion Sources (ECRISs) that utilize Nb-Ti superconducting coils for 28 GHz frequencies have been operating effectively for over twenty years. However, transitioning to higher frequencies demands stronger magnetic fields, and the conventional racetrack-and-solenoid ECRIS structures have reached their maximum capability with Nb-Ti. To address this, a Mixed Axial and Radial field System Demonstrator (MARS-D) is being developed at Lawrence Berkeley National Laboratory (LBNL). This system features an innovative Closed-Loop Coil (CLC) design that optimizes the use of the conductor fields, enabling the application of Nb-Ti in the next-generation 45 GHz ECRISs. The fabrication of the hexagonal CLC is particularly challenging due to its complex winding path and shape, the stiffness of the Nb-Ti superconducting wire, and the small bending radius. To address these challenges, a series of unique fixtures and tools, as well as a pre-over-bending method, were developed for winding the CLC. To validate the winding fixtures, tools, procedures, and materials used in the coil assembly, a 4-layer practice CLC was wound, epoxy-impregnated, and then cold-tested using liquid nitrogen. The full-size MARS-D CLC is in the process of winding. This paper presents the structure of the MARS-D CLC, the winding fixtures and tools, the winding procedures, the quality control, the impregnation, the test results, and the potential future improvements.


  • Design Margin Comparison of a Sextupole-in-Solenoid and a Closed-Loop-Coil Type Nb-Ti Superconducting ECR Magnets

    by Ye Yang, Paolo Ferracin, Jose Ferradás Troitiño, Mariusz Juchno, Janilee Benitez, Damon Todd, Lianrong Xu, Jaime Cruz Duran, Diego Arbelaez, Tengming Shen, et al.

    Third-generation electron cyclotron resonance ion sources (ECRISs) have relied on a combination of sextupole and solenoid fields from Nb-Ti superconductors to produce the magnetic fields required for 28 GHz operation. The VENUS ion source at Lawrence Berkeley National Laboratory (LBNL) was the first third-generation ion source optimized for 28 GHz operation, and since that time a similar design has been adopted at other heavy-ion facilities such as RIKEN, GANIL and FRIB. These sources utilize a sextupole-in-solenoid design and represent the high-field limit of this design using Nb-Ti superconductor. To get past this limit without moving to a more difficult-to-use superconductor material, LBNL is developing a fourth-generation, 45 GHz ECRIS, called MARS-D, with a closed-loop coil structure. Since both the sextupole and solenoid fields are efficiently produced by the closed-looped coil, the 45 GHz ECRIS can be realized using the Nb-Ti conductor. In the MARS-D design, the maximum field on the conductor is 8.3 T at 4.2 K, and the operation point is about 90% of the short sample limit. As this tight load line margin may leave the source susceptible to quench, we investigate and compare the design parameters with the most recent VENUS-type superconducting ECRIS which is already under operation at FRIB in this paper. Additionally, we investigate the advantages of the MARS-D-type structure by keeping the coil design constant and only replacing the conductor with the one used in FRIB and VENUS.

  • Shell-Based Support Structure for the 45 GHz ECR Ion Source MARS-D

    by M. Juchno, J. Y. Benitez, J. Doyle, A. Hodgkinson, T. Leow, L. W. Phair, D. S. Todd, L. Wang, D. Vv Z. Xie

    Superconducting electron cyclotron resonance ion sources (ECRISs) using NbTi coils and optimized for 28 GHz resonant heating have been successfully operated for almost two decades. Moving to higher heating frequencies requires increased magnetic fields, but traditional racetrack-and-solenoid ECRIS structures are at their limit using NbTi. Rather than moving to a superconductor untested in this field, the Mixed Axial and Radial field System (MARS) being developed at Lawrence Berkeley National Laboratory employs a novel closed-loop-coil design that more efficiently utilizes conductor fields and will allow the use of NbTi in a next-generation, 45 GHz ECRIS. This article presents the design of the shell-based support structure central to the MARS-D magnet design, as well as structural analysis of its components and optimization of pre-load parameters that will guarantee its successful operation.


  • Open Access

    Development of a new high temperature oven for the production of intense metal ion beams with ECR ion sources

    by W. Huang, D. Z. Xie, L. T. Sun

    High Temperature Ovens (HTOs) have widely been used to evaporate refractory materials in electron cyclotron resonance ion sources to produce hundreds of microamperes of multiply and highly charged metal ion beams. To meet the demands of milliamperes of multiply charged uranium and other heavy metal ion beams for future accelerators, a new and low-cost HTO is under development at Lawrence Berkeley National Laboratory for better long-term stability at high evaporation rates. ANSYS simulations have been carried out to optimize the new HTO with low heating current to reduce the electromagnetic forces as an HTO is immersed in the strong ECRIS magnetic fields. A larger loading volume is employed to deal with higher material consumption. Off-line tests have shown that the unloaded new HTO operates stably up to 1800–1900 °C with low temperature gradients and good repeatability. This paper presents and discusses the conceptual design features of the new HTO and off-line tests.


  • Superconducting ECR ion source: From 24-28 GHz SECRAL to 45 GHz fourth generation ECR

    by H. W. Zhao, L. T. Sun, J. W. Guo, W. H. Zhang, W. Lu, W. Wu, B. M. Wu, G. Sabbi, M. Juchno, A. Hafalia, et al.

    The development of superconducting ECR source with higher magnetic fields and higher microwave frequency is the most straight forward path to achieve higher beam intensity and higher charge state performance. SECRAL, a superconducting third generation ECR ion source, is designed for 24-28 GHz microwave frequency operation with an innovative magnet configuration of sextupole coils located outside the three solenoids. SECRAL at 24 GHz has already produced a number of record beam intensities, such as 40Ar12+ 1.4 emA, 129Xe26+ 1.1 emA, 129Xe30+ 0.36 emA, and 209Bi31+ 0.68 emA. SECRAL-II, an upgraded version of SECRAL, was built successfully in less than 3 years and has recently been commissioned at full power of a 28 GHz gyrotron and three-frequency heating (28 + 45 + 18 GHz). New record beam intensities for highly charged ion production have been achieved, such as 620 eμA 40Ar16+, 15 eμA 40Ar18+, 146 eμA 86Kr28+, 0.5 eμA 86Kr33+, 53 eμA 129Xe38+, and 17 eμA 129Xe42+. Recent beam test results at SECRAL and SECRAL II have demonstrated that the production of more intense highly charged heavy ion beams needs higher microwave power and higher frequency, as the scaling law predicted. A 45 GHz superconducting ECR ion source FECR (a first fourth generation ECR ion source) is being built at IMP. FECR will be the world’s first Nb3Sn superconducting-magnet-based ECR ion source with 6.5 T axial mirror field, 3.5 T sextupole field on the plasma chamber inner wall, and 20 kW at a 45 GHz microwave coupling system. This paper will focus on SECRAL performance studies at 24-28 GHz and technical design of 45 GHz FECR, which demonstrates a technical path for highly charged ion beam production from 24 to 28 GHz SECRAL to 45 GHz FECR.


  • Open Access

    Quench Protection of a Nb$_3$Sn Superconducting Magnet System for a 45-GHz ECR Ion Source

    by E. Ravaioli, S. J. Zheng, A. Ray Hafalia, M. Juchno, W. Lu, Gl Sabbi, L. Sun, W. Wu, D. Xie, H. W. Zhao

    Lawrence Berkeley National Laboratory in collaboration with the Institute of Modern Physics has developed a Nb 3 Sn-based superconducting magnet system for a fourthgeneration electron cyclotron resonance source, with a goal of achieving the magnetic field required for operating at the microwave frequency of 45 GHz. The magnet system is composed of one sextupole magnet inside three solenoids of different sizes manufactured from Nb 3 Sn round wire. Given the high stored energy density and relatively low wire copper fraction, the coils are not self-protected in the case of a quench. The study of the transient following a quench is carried out by means of the lumped-element dynamic electro-thermal program, which includes a detailed simulation of the interfilament coupling losses developing in the wire. Nonlinear effects occurring in the magnet, such as coupling loss and differential inductance reduction, have a significant impact on protecting these magnets. The resulting baseline quench protection strategy based on four independent energy extraction systems protecting the four magnets meets the quench protection requirements. Furthermore, in order to enhance the redundancy of the quench protection system and reduce the peak voltages to ground, the implementation of a coupling-loss induced quench (CLIQ) system is considered.


  • Superconducting Magnets for High Performance ECR Ion Sources

    by Liangting Sun, Wang Lu, Enming Mei, GianLuca Sabbi, Wei Wu, Daniel Xie, Hongwei Zhao

    Modern heavy ion accelerators require intense heavy ion beams with high charge state. Electron cyclotron resonance (ECR) sources are the primary tool for generating such beams, making them indispensable devices for heavy ion physics research. Remarkable performance advancements were obtained during the last decades. At present, state of the art “third generation” ECR ion sources are based on magnets built with NbTi conductor. However, future nuclear physics facilities will require significant improvement in beam intensity and quality, which can only be met by ECR sources operating at higher frequency and field. These fourth generation machines will need to incorporate a sophisticated sextupole magnet built with high performance Nb 3 Sn or NbTi conductor. In this paper, we review the technical challenges and worldwide progress in developing high performance superconducting ECR ion sources, and discuss the development of both third and fourth generation ECR ion source magnets at IMP.


  • Development status of a next generation ECRIS: MARS-D at LBNL

    by D. Z. Xie, J. Y. Benitez, A. Hodgkinson, T. Loew, C. M. Lyneis, L. Phair, P. Pipersky, B. Reynolds, D. S. Todd

    To demonstrate a Mixed Axial and Radial field System (MARS) as the best magnet scheme for future ECRISs, MARS-D, a demonstrative ECRIS using a NbTi MARS magnet is progressing at Lawrence Berkeley National Laboratory. An optimized MARS design can use either NbTi or Nb3Sn coils with reduced engineering complexities to construct the needed high-field magnets. The optimized magnet design could enhance MARS-D to a next generation ECRIS by producing minimum-B field maxima of 5.6 T axially and 3.2 T radially for operating frequencies up to 45 GHz. In-progress test winding has achieved a milestone demonstrating the fabrication feasibility of a MARS closed-loop coil.


  • A low energy beam transport system for proton beam

    by Y. Yang, Z. M. Zhang, Q. Wu, W. H. Zhang, H. Y. Ma, L. T. Sun, X. Z. Zhang, Z. W. Liu, Y. He, H. W. Zhao, et al.

    A low energy beam transport (LEBT) system has been built for a compact pulsed hadron source (CPHS) at Tsinghua University in China. The LEBT, consisting of two solenoids and three short-drift sections, transports a pulsed proton beam of 60 mA of energy of 50 keV to the entrance of a radio frequency quadrupole (RFQ). Measurement has shown a normalized RMS beam emittance less than 0.2 π mm mrad at the end of the LEBT. Beam simulations were carried out to compare with the measurement and are in good agreement. Based on the successful CPHS LEBT development, a new LEBT for a China ADS projector has been designed. The features of the new design, including a beam chopper and beam simulations of the LEBT are presented and discussed along with CPHS LEBT development in this article.